Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹16.8 LAccepted-AOC 51 212D 3E K V NAGAR NEAR ADARSH NAGAR KHERIA MOD AGRA UP 282001 | AGRA | UTTAR PRADESH | 282001 | L-1 | Accepted-AOC FOUND LOWEST AND REASONABLE | |
| 2 | L-2₹18.4 L+₹1.4 L (8.22%)Rejected-Finance VILL NANDA KA NAGLA DHAOLI AGRA 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L-2 | Rejected-Finance Being other than lowest | |
| 3 | Not Admitted-Fee/PreQual/Technical 59 100 AJIT NAGAR GATE KHERIA AGRA 282008 | AGRA | AGRA | UTTAR PRADESH | 282008 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 4 | Not Admitted-Fee/PreQual/Technical FLAT NO 404 BLOCK II NIRMAL HEIGHT SECTOR 12A OLD MATHURA ROAD AGRA 282007 UP | AGRA | AGRA | UTTAR PRADESH | 282007 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
28 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) TECH AREA AGRA
GE (AF) TECH AREA AGRA
WORK SERVICES FOR IMPROVEMENT TO GCA BLDG IMPROVEMENT TO OVER HEAD FILLING POINTS AND ALLIED WORKS AT FIRE SECTION AND PROVN OF CERTAIN REVENUE WORKS AT AF STATION AGRA UNDER GE (AF) TECH AREA AGRA
2020_MES_354301_1
8200-1224/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) TECH AREA AGRA
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) TECH AREA AGRA
₹44,000
Yes
19 Dec 2020
20 Jun 2020
1 Aug 2020
20 Jun 2020
28 Jul 2020
4 Jul 2020
20 Jun 2020 - 27 Jun 2020
60 days
Amount
Cutting of Roofs, floors (other than ground floors), beams staircases, landing, chajjas, and similar suspended work n.exc 250mm thick with Electric/Machanic opreated machine including cutting of reinforcement carefully without causing damage to adjoining areas complete all as specified and as directed.
Dismantling of existing roof treatment consisting of screed, tar felts etc and removal of dismantled materials/debries outside MD land complete all as specified and as directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards any thickness and in any position including cover fillets complete all as specified and as directed
Taking down cement plaster in cement or cement lime mortar on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc, Including removal of debries out side MD land complete all as specified and as directed
Dismantling floor hearth or wall tiling incl cement mortar bedding and removing rubbish off the premises complete all as specified and as directed
Taking up or down steel tubing and connections for 15mm bore pipe complete all as specified and as directed
Taking up or down steel tubing and connections for 20mm bore pipe complete all as specified and as directed
Taking out old serviceable glass of any description from old wooden or metal frames, or stone, concrete or brick surrounds, any thickness or size; hacking out old putty or removing beads etc. including making good breakages in taking out and handing removing to store or stacking for reuse complete all as specified and as directed.
Hacking out old broken glass any thickness size quality or description from wooden/ metal frame glazed with oil putty or fixed with beads complete all as specified and as directed
Demolition of cement concrete unreinforced in ground floors and paving n.exc 15cm thick complete all as specified and as directed.
Dismantling of AC sheets/Galvalume sheet and the likes; (corrugated /semi corrugated/plain) in roof covering including ridge complete all as specified and as directed
M&L for roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and as directed
M & L for brushing neat cement slurry with 3 kg of cement per sq. metre complete all as specified and as directed
M&L15mm thick screed in cement mortar 1:4 on concrete surfaces mixed with water proofing compound @ 3% by weight of cement content, finished even and smooth without using extra cement as in roof complete all as specified and as directed. Note:- Water proofing compound shall be measured and paid seperately here-in-after
Supply only Integral water proofing compound complete all as specified and as directed
M&L water proofing treatment to RCC Roof slab including parapet comprising with the following course of treatement complete all as specified and as directed from bottom to top :- (a) Applying Bituminous primer @ 0.40 Ltr per Sqm over plastered surfaces of Roof including parapet surfaces. (b) Over the priming coat laying one layer APP based polymeric membranes of approved manufacturer, 3mm thick weight not less 3.50 Kgs/Sqm reinforced with non woven polyester fabric weight not less than 160 gms per Sqm. Polymeric membrane shall be taken to a height of 60cm (minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flushing in a coat of aluminium paint over roof surfaces. (i) Laying APP based polymeric membranes shall be done by torch on method as per manufacturer's instructions. (ii) A minimum overlap of 100mm shall be made and at the end 75mm shall be made at the sides of the polymeric membranes respectively and sealed all overlaps and joints as per Manufacturer's instructions. (c) Applying two coats of aluminium paint over top of APP membrane @ 0.10Kg/Sqm
Disconnecting existing tanks, set aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and refixing in position of capacity exc 250 Ltrs but n.exc 500 Ltrs (cleaning, repairing etc shall be measured and paid separately) complete all as specified and as directed.
Cleaning and removing all scale and dirt etc. from tanks and from mouth of circulating pipes etc of capacity exc 250 Ltrs but n. exc 500 Ltrs complete all as specified and as directed.
S&F ball valves 20 mm dia high pressure of PTMT with expxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (minimum weight 210 gms) complete all as specified and as directed
M&L brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM (1:6) complete all as specified and as directed
M&L for rendering 5 mm thick in CM (1:3) on fair faces of ceiling and concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed
M&L for rendering 10mm thick in CM (1:6) on fair faces of brick works or concrete surface finished even & smooth without using extra cement complete all as specified and as directed
M&L for 15mm thick rendering on fair faces of brick work/concrete surfaces in CM 1:4 finishing the surface fair & even, mixed with water proofing compound @ 3% by weight of cement content complete all as specified and directed. Note:- Water proofing compound shall be measured and paid separately here-in-before
M&L for preparation of old plastered or unplastered surface of ceiling including cornices etc. by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots and removal of vegetation and applying one coat of white wash on old surface of ceiling complete all as specified and as directed
M&L for preparation of newly plastered surfaces of wall and ceiling and applying three coats of white wash complete all as specified and as directed.
M&L for two coats of oil bound distember on the new plastered surfaces of wall including the preparation of the surfaces over a coat of primer
M&L for preparation of new or old surfaces of wall (Plastered or unplastered) and applying two coats of exterior emulsion paint of approved make over a coat of primer complete all as specified and as directed
M&L for preparation of old decorated plastered or un-plastered surfaces of walls and applying one coat of cement base paint complete all as specified and as directed
M&L for preparation of new/old plastered or un-plastered surfaces of walls and applying two coats of cement base paint complete all as specified and as directed
M&L for preparation of old distempered surface of wall including cornices etc. by washing, rubbing down and stopping of distempered and painting surfaces, and applying one coat of oil emulsion distemper of approved shade complete all as specified and as directed
M&L for anti-termite treatment of soil under existing floors and junctions of wall & floor, using chemical emulsion @ one ltr per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 including white cementing and finishing the disturbed surfaces to match the existing finishes of wall and floor complete all as specified and as directed
M&L for Providing and injecting chemical emulsion for Post Constructional Anti-termite Treatment along external wall where the apron is nor provided using chemical emulsion at the rate of 7.5 litres per Sqm of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc. complete all as specified and as directed
S&F steel water tubing medium grade galvanized with and including all fittings and fixed complete to walls, ceilings or laid on floors, bore of tube 15mm complete all as specified and as directed
S&F steel water tubing medium grade galvanized with and including all fittings and fixed complete to walls, ceilings or laid on floors, bore of tube 20mm complete all as specified and as directed
S&F in repair, bib taps fancy type, chromium plated, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule of 15mm bore complete all as specified and as directed
S&F in repair, stop valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipes or for unions of 15mm bore complete all as specified and as directed
S&F in repair PVC (SWR) floor trap, with chromium plated grating including jointing with solvent cement, dia of outlet 75mm complete all as specified and directed
S&F in repairs white vitreous china squatting pan ‘ORISSA’ pattern of size 630mm x 450 mm white with integral foot rests with ‘P’ or ‘S’ trap, front or back inlet including all connection and provision of lime concrete base complete all as specified and as directed
S&F in repairs vitreous China wash down water closet pan (pedestal pattern), white (excluding flushing cistern and flush pipe) complete all as specified and as directed.
Supply only PVC water closet seat cover, black/ white closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinges device for EWC complete all as specified and directed
S&F in repair, vitreous china wash basin, white, flat back of size 550mm x 400mm including brackets grouted in cement mortar 1:2 in wall complete all as specified and as directed. Note :- Supply only pillar taps, waste fittings, PVC connection, PVC waste pipe shall be measured and paid separately
Supply only pillar taps, cast copper alloy with capstan head, chromium plated, fancy type, screwed down high pressure, with or without lettered ‘hot’ or ‘cold’ with long screwed shanks and fly nuts, screwed for iron pipes 15mm bore complete all as specified and as directed
Supply only 32mm dia waste coupling of CP brass for wash hand basin complete all as specified and as directed.
Supply only PVC waste pipe, flexible 40mm bore 60cm long for Wash Hand Basin complete all as specified and as directed
Supply only PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and as directed.
S&F in repairs or PVC valveless, syphonic action type, flushing cistern, 10 litres capacity low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and as directed
S & F Toilet paper holder , vitrous china , box type fix to wall with chromium plated brass screw complete all as specified and as directed.
S&F Chromium plated jet sprey (Health faucet) for pedestal pan including all necessary fitting etc complete all as specified and as directed
S&F in repair vitreous china Urinal half stall type complete including providing and fixing plugs,chromium plated urinal spreader, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement complete all as specified and as directed
M&L for 10 mm thick Vitrified ceramic tiles, light shade (square/recangular) area of each tile not exceeding 0.36 Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, with and including screed bed or bedding layer with and including 15 mm thick in CM (1:6) for laying floor finishes complete all as specified and as directed
M&L for glazed ceramic coloured tiles in vertical surface of size 450X 300X 7 to 8mm thick as on walls with and including 10mm thick rendering in CM (1:4) and jointing in neat cement slurry and pointing in coloured cement to match the inside of tiles complete all as specified and as directed
M&L for non skid ceramic joint less coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. , laid over with and including 15mm thick screed bed in cement mortar 1:6 incl jointing in neat cement slurry and pointed in coloured cement to match with shade of tiles complete all as specified and as directed
S&F Anodised aluminium snap grid frame work for false ceiling and Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified and as directed
S&F 12mm thick Perforated particle board/tiles for insulation and acoustic purposes, 60x60 cm in size, fixed with nails to timber frame work or with staples on snap grid complete all as specified and as directed.
S&F 12mm thick Perforated particle board/tiles for insulation and acoustic purposes, 60x60 cm in size, fixed with nails to timber frame work or with staples on snap grid in ceiling complete all as specified and as directed.
S&F for suspended false ceiling grid system 600x600mm with main runner 39x29x0.80 mm, cross tee 39x27.70x0.80mm and wall angle 22.2x22.2x0.65 mm in ceiling suspended @ 1.20m C/C both way with 4mm dia GI wire hanger fixed with steel dash fasteners or from purlin of roof with butterfly clips hold down etc, complete (main runner/cross tee / wall angle of galvanised iron powder coated) complete all as specified and as directed
S&F HPSC pre-prime non asbestos fiber cement building board (E-classic) decorative finish fixed to aluminium or MS galvanised snap grid fram work with hold downclips in ceiling complete all as specified and as directed. Make : Everest/Ramco/Charminar
Fixing only tinted sheet glass of any thickness ordinary quality and glazing with oil putty or beads in square not exceeding 0.50 sqm in each pane, complete all as specified and as directed
Supply and fixing 5.5mm thick tinted sheet glass ordinary quality and glazing with oil putty or beads in square not exc 0.50 sqm in each pane, complete all as specified and as directed
S&F in repair 12mm thick prelaminated particle board Exterior grade prelaminated both sides with decorative choice lamination and fixing in same position from aluminium partition carefully including replacement of defective aluminium beading cleat if required complete all as specified and as directed
Resecuring or easing and adjusting wooden, aluminium, PVC door/window, without taking down shutters of any description exc 1 sqm but not exc. 4 sqm each complete all as specified and as directed
S&F in repair aluminium (Die cast) body, door closer hydraulically regulated designation No-1, universal type, suitable for door shutters of weight not more than 35 kg complete all as specified and as directed
S&F looking mirror of size 600X500mm, made of plastic body, decorative type complete all as specified and as directed.
M&L for 75mm thick cement concrete (1:3:6), type C-2 (using 40mm graded stone aggregate) as in plinth protection and the likes; finishing surfaces even & smooth without using extra cement complete all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strenght of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed
S&F MS rolled section such as angle iron/flat iron and the likes; fixed independently without connecting plate complete drilled for fixing of steel sheeting conforming to Fe 410-W (Gde E-250) quality 'A' complete all as specified and as directed
S&F mild steel works as in wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0 upto any height of bldg complete all as specified and as directed
Preparing new steel surfaces of any description exc 10cm width or grith and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed
M&L for cement concrete (1:2:4), type B-1 (using 20mm graded stone aggregate) as in coping, holdfasts, kerbs, plinth course cills and the likes; including weathering, slightly rounded or chamfered angles and throating, including necessary form work complete all as specified and as directed
M&L for cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed
S&F powder coated aluminium grills, size cx. 4mmx4mm, 8mm thick and aperture n.exc. 80 mm width including fixing with aluminium channel 10-12mm wide, 1 mm thick with steel screw and tint to match with existing finishes complete all as specified and as directed
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc, and making good disturbed surfaces of walls, ceilings etc complete all as specified and as directed.
Taking down main switches/DB's (alongwith existing board, MCBs & isolators) and making good disturbed surfaces complete all as specified and as directed.
Taking down existing old unserviceable sub main wiring of any type and description, removal of teak wood batten/ PVC pipe/ PVC casing & caping and making good disturbed surfaces of walls, ceilings etc as per existing finishes complete all as specified and as directed
M&L for point wiring complete with standard copper conductor 1.5 sqmm size (Nominal area) 1100 volts grade PVC insulated unsheathed multi stranded copper conductor cable in and including concealed PVC conduit ISI marked not less than 20mm dia with concealed sunk in pressed steel terminal boxes of reqd size of thickness 1.6mm factory made and painted with stove enameled black paint with top cover 3mm thick plastic laminated sheet of required colour fixed with brass screws and cup washer including 1.5sqmm standard copper conductor PVC insulated unsheathed cable of green green colour as earth continuity connected to common earth dolly and all sunk/terminal boxes and each fitting/fixture, complete with all acessories and including cutting and chasing complete all as specified and as directed
S&F one light point controlled by one no. piano type switch 5 Amp, single pole, one way complete all as specified and as directed
All as per srl item no. 75.00 above but for 3/5 pin socket outlet for 15 Amps on independent board with 2.5 sqmm PVC insulated, unsheathed single core multistranded copper conductor cable 1100 volts grade including 2.50 sqmm PVC insulated unsheathed multi stranded copper conductor cable as earth continuity conductor complete all as specified and as directed
S&F of socket outlet 2 in 1, 3 pin 5 Amps flush universal type ISI marked with valid CML No complete all as specified and as directed
S&F of socket outlet 2 in 1, 3 pin 15 Amps flush universal type ISI marked with valid CML No complete all as specified and as directed
S& F lamp holder insulated body any type with back plate suitable for batten/angle fittings complete all as specified and as directed
S&F of ceiling rose, surface bakelite 32mm x 25mm, 2 to 3 terminals suitable for batten fittings ISI marked with valid CML No complete all as specified and as directed.
S&F of LED Adore Lamp 18W B22 CDL type of Havells make or equivalent of Philips/Crompton Greaves/Surya completes all as specified and as directed.
S&F surface/wall mounting LED batten extruded aluminium housing provided for efficient heat dissipation with poly carbonate diffuser & integrated electronic driver including 20 W LED lamp complete all as specified and as directed. Make- Havells/Bajaj/CG
S&F of recessed mounting 2X2 square slim and elegant downlight / panel 36Watt LED luminaires suitable for direct ceiling mounting, with its super bright LED, is delight in modern office environment this panel gives a soft soothing light for super bright efficient and high aesthetic appeal LED's complete fixed to ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified and as directed. Make:- Crompton Greaves Cat No LCTLRN-36-FO-CDL or equivalent in Philips/ Bajaj/ Havells
S&F of surface and wall mounting LED mini mirror light fitting with decorative plastic housing and robust construction with reflector cover and decorative end plate complete varied application fixed to wall with fixing accessories and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified and as directed. Make:- Crompton Greaves Cat No LCL-14-CDL or equivalent of Philips/Bajaj / Havells
S&F of MCCB VTPN DB 4 way with protection IP 43 and provn for DPX160 MCCB and ELM as incomer and SP/TP MCB as outgoing, made out of 1.6mm thick CRCA sheet factory made and painted suitable for universal mounting with 200 amps bus bar neutral earth with and cable ties for cable management top and bottom removable gland plate suitable for three phase incoming /outgoings complete all as specified and as directed. Make : Legrand cat No- 6077 50 or equivalent make of Siemens/ L&T/Havells
S&F of MCCB DPX160, 4 pole 415 volts, 100 Amps with breaking capacity 16kA complete all as specified and as directed
S&F of MCB SP 6 to 32 Amps, 240 V 'C' series 10 KA complete all as specified and as directed.
S&F of MCB DP 40 to 63 Amps, 240 V 'C' series 10 KA complete all as specified and as directed.
M&L for factory made sheet metal enclosure 240 volts, 4 ways with 200A rated bus bar, SPN, double door type suitable for housing MCBs/Isolators and fixed the same on & including mild steel hold fasts of suitable size & shape after grouting the hold fasts in the wall with and including PCC (1:2:4) type B1 using 20mm graded stone aggregate complete all as specified and as directed
M&L for provision of sub main wiring with approved colour coding as per IS (Red, Black and green for single phase circuits) with two runs of single core FR PVC insulated, unsheathed, multi stranded copper conductor cable (Red&Black colour) of size 6.0 sqmm drawn in and including PVC casing & caping ISI marked not less than 32mm width with its accessories or drawn in and including PVC rigid conduit not less than 32mm dia with its accessories, surface type, including one run of single core FR PVC insulated, unsheathed, multi stranded copper conductor cable (Green colour) of size 6.0 sqmm as earth continuity and connected of common earth dolly complete all as specified and as directed. Note:- Two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable alongwith PVC casing & caping or PVC conduit including its accessories shall be measured and paid one unit length
Supply, laying commissioning, testing of XLPE , armoured heavy duty electric under ground LT cable 1100 volts grade of size 35 Sqmm, 1/2 core with aluminium conductor conforming to IS 1554, laid in trenches, fixing on wall, under road crossing, etc complete all as specified and as directed
Supply and laying or fixing or passing in well/ borewell 1100 volts grade heavy duty, PVC insulated and PVC sheathed mutistranded copper conductor submersible cable of size 6.0sqmm 3 core flat including connection to submersible motor/ starter panel with & including necessary jointing materials if required and testing on completion complete all as specified and as direced. Make :- Havells/ Plaza or equivalent
Supply,laying and fixing galvanized steel tubing medium grade with fitting of size 100 mm dia laid in trenches complete all as specified and as directed
Supply,laying and fixing galvanized steel tubing medium grade of size 100 mm dia with all fitting fixed complete to walls and ceilings or laid in floors complete all as specified and as directed
S&F cast iron body sluice valve ISI marked PN 1.0 and conforming to IS 14846 with stainless steel spindle of 100 mm bore complete all as specified and as directed
S&F in replacement of non return valve of size 100 mm bore, ISI marked including fixing accessory complete all as specified and as directed.
M & L earthing complete with Gl electrode 600x600x6.00mm thick buried directly in ground vertically in pit of depth not less than 3.75 mtr below normal ground level with top edge of the earth plate not less than 3.00 mtr below normal ground level connected to Gl strip 30x5 mm as earthing lead by means of bolts, nuts, check nuts and washers of brass connected all as specified including excavation and earth work and disposal of surplus soil incl 40 mm Gl tubing light grade and necessary fitting for protection of Gl strip incl laying of charcoal, dust and common salt PCC (1:2:4) type Cl using 20mm graded stone aggregate earth pit with 40x40x6mm MS angle iron frame RCC cover 40mm thick (1:2:4) type B0 using 12.5mm graded stone aggregate reinforced with 8mm dia round bar @ 75mm C/C both way with MS handle 12mm dia, plastering 15mm thick CM (1:6:) internally and upto 150mm below ground level externally. Funnel with wire mesh 20mm dia Gl pipe for watering complete all as shown on electrical plate No.3 of SSR Part -1 2009 and connected to earth test point including testing complete all as specified and as directed Note :- Cost of GI strip upto distance of 7.5 mtr shall deemded to be included in quoted rate by contractor
M& L for valve chamber, 900x900x900mm (internal dimensions) with 230mm brick masonry in CM 1:6, PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation, PCC 1:2:4 typeB0 using 12.5mm graded stone aggregate as in coping 50mm thick, rendering 15mm thick in CM 1:4 to all internal and exposed surface including necessary excavation and earth work in hard/dense soil, MS sheet cover 3.15mm thickness alongwith angle iron frame of size 40x40x6mm with locking arrangement with necessary fixing materials like hinges, but bolts etc (Valve chamber cover shall be opended in two halves) and painting to MS cover with two coats of synthetic enamel paint over one coat of red oxide primer etc complete all as specified and as directed
Supply,installing,connecting,commissioning of open well submersible pump set water cooled of capacity 7.5 HP,3 phase,415 V,50HZ,Suction delivery 100mmx100mm,Head range 14-22 Mtr, discharge 1515-960LPM, 2920RPM complete with auto cut float valve including all cable of required size upto 30 RM complete all as directed. Make- Kirloskar model KOS-822+ or equivlent in Crompton/KSB
Fabricate Supply, install, test commissioning LT panel board suitable to operate 3ph, 50Hz, AC submersible motor pump fabricated with MS CR sheet 3.15 mm thick sheet Encls out door type with dust, vermin and water tight / weather proof including IP - 55 protection class including complete Internal wiring with copper flexible strainded PVC sheathed wire not less than 10 sq mm installation with necessary PCC foundation, MS angle with power coated paint. Including self locking arrangement comprising the following: - (a) Star Delta starter suitable to submersible motor pump set, 03 phase 7.5/10 HP motor, 415 V, AC, 50 HZ complete with all accessories and safety features - 02 Nos (b) MCCB –100 Amp, 4 Pole, 25KA 415 V, 50 HZ AC- 01 Nos (c) MCCB –63 Amp, 4 Pole, 25KA 415 V, 50 HZ AC- 02 Nos (d)Single Phase Preventer - 02 Nos (e) Dual meter combination to read voltage 0 – 500V and current 0 – 50 A in three phase system (f)Toggle switch for manual /auto operation - 02 Nos (g)Indication lamp for RYB LED type (h)Bakelite fuse with HRC fuses 2 Amp on three phases (j)Indication Lamp for power ON. (k)Terminal block 60A for incoming supply for RYBN (l)Terminal block 60A to out going supply for RYBN (m) LT Panel with busbar & inter connection-1 Job (n) Cable Glands-05 Nos (o) PCC and Angle iron frame (p)One light point with spiral LED Lamp 5 W
S&F MCCB four pole AC 415 volts, 50 Hz, fixed thermal & fixed magnetic setting type of capacity 100 Amps having breaking capacity25 kA complete all as specified and as directed. Make:- Legrand/ L&T/ Havells or equivalent make
Demolition of PCC/Black bitumin road of any description and in any position not otherwise specially provided for complete all as specified and as directed
M&L PCC (1:2:4) type B2 (using 40mm graded aggregate) as in surface,chanells and drains complete all as specified and as directed
M&L for GI tubing light grade 40 mm bore and laying in trenches/floor etc for protection of cable complete all as specified and as directed
Excavation in trenches in soft/loose soil n. exc 1.5M wide and n. exc 1.5 in depth for foundation, laying cables/pipe/pole etc and getting out complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n. exc 25 cm thick after the cables etc. are laid, jointed and tested complete all as specified and as directed
Removing surplus excavated material (soil) to a distance n.exc 50 Mtr and depositing where directed at a level n.exc 1.5 Mtr above the starting point complete all as specified and as directed
Supply and laying sand cushioning with dray fine sand including filling, spreading, levelling in layers for cable protection in trenches 8cm before laying cable and 15cm thick over the cable complete all as specified and as directed Note : Punned thickness only shall be measured and paid
Supply & lay brick well burnt bricks sub-class 'B' locally available old size laid flat across the length of trench for protection of cable complete all as specified and as directed
GIRENDRA SINGH AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .