| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.1 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹44.3 L+₹27,543 (0.63%)Rejected-Finance FLAT NO 201 GREEN VALLEY CHS PLOT NO 26 SECTOR 19 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L2 | Rejected-Finance NOT ADMITTED BEING L2 | |
| 3 | L3₹45.7 L+₹1.8 L (3.99%)Rejected-Finance 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | L3 | Rejected-Finance NOT ADMITTED BEING L3 | |
| 4 | L4₹46.9 L+₹2.9 L (6.61%)Rejected-Finance SHOP NO 12 KHOPKAR APARTMENT KUMBHARAWADA URAN DISTT RAIGAD 400 702 | URAN | RAIGAD | MAHARASHTRA | 400702 | L4 | Rejected-Finance NOT ADMITTED BEING L4 | |
| 5 | L5₹47.9 L+₹3.9 L (8.96%)Rejected-Finance | L5 | Rejected-Finance NOT ADMITTED BEING L5 |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
5 Oct 2024, 6:00 pmClosed
GE NW KARANJA
NAVAL STATION KARANJA, URAN, RAIGAD, MAHARASHTRA
REPAIR REPLACEMENT OF FLAME PROOF WIRING FLAME PROOF FITTING HIGH BAY LIGHT BULK HEAD FITTING FLAME PROOF SWITCHES AND SOCKET FLAME PROOF DB AND OTHER MISC WORK AT NAVAL STATION KARANJA
2024_MES_668417_1
8983/E8
Open Tender
Electrical and Maintenance Works
Item Rate
243 days
GE NW KARANJA
D and above b i
8 documents required · 8 mandatory
₹500
Yes
GE NW KARANJA
₹94,000
Yes
14 Nov 2024
31 Aug 2024
7 Oct 2024
31 Aug 2024
5 Oct 2024
13 Sept 2024
Amount
Notes : (i) The work consists of 02 jobs as under:- JOB (A) : TPP 2024-2025 Ser No. 61 (ii) Please refer schedule 'A' notes before quoting the tender. (iii) Amount of Schedule of Credit shall be deducted off line by the department. ITEMS FOR JOB 'A'
Note :- The rate quoted is inclusive for the following :- (i) (a) Attending minor repairs/breakdowns without involving any new (major) materials. (b) Cost includes the tools for attending break down and minor materials like lugs and PVC tapes,Job Cards and Complaint registers etc. (c) Major repairs,Break downs invloving S&F of materials such as cables,Joints,MCCBs etc are out side the scope of this item and shall be measured and paid separately. (d) Contractor should ensure to carry out the work through qualified Technician/Electrician and assisted by the helper. Necessary tools & plants and transportation charges are deemed to be included in the unit rate quoted.
M&L for submain wiring with single core 1100 volts 1.5 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etc with and including 1.5 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly complete all specified and directed.
M&L for submain wiring with single core 1100 volts 1.5 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including in existing stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etc with and including 1.5 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and ,connecting to earth point and connecting to earth dolly complete all as specified and directed.
M&L for submain wiring with single core 1100 volts 2.5 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etc with and including 2.5 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and ,connecting to earth dolly complete all as specified and directed.
M&L for submain wiring with single core 1100 volts 2.5 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including in existing stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etc with and including 2.5 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and, connecting to earth dolly all specified and directed.
M&L for submain wiring with single core 1100 volts 4 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etc with and including 4sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly complete all as specified and directed.
M&L for Submain wiring with single core 1100 volts 4 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including in existing stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etc with and including 4 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly complete all as specified and directed.
M&L for submain wiring with single core 1100 volts 6 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etc with and including 6 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and ,connecting to earth dolly complete all as specified and directed.
M&L for submain wiring with single core 1100 volts 6 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through existing stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etc with and including 6 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and, connecting to earth dolly all complete all as specified and directed.
M&L for submain wiring with single core 1100 volts 10 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etc cwith and including 10 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly complete all as specified and directed.
M&L for submain wiring with single core 1100 volts 10 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through existing stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etc with and including 10 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly for complete all as specified and directed.
M&L for submain wiring with four core 1100 volts 10 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etc with and including 10 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly for complete all as specified and directed..
M&L for submain wiring with four core 1100 volts 10 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through existing stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etc complete with and including 10 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly complete all as specified and directed.
Taking down carefully from ceiling /wall submain of any size all including necessary arrangement ladder etc specified and directed in charge.
S&F in repairs flame proof LED well glass hanging type 60w fitting on existing light point with suitable hanging arrangements for one light control with one MCB SP, complete all as specified and directed. Note:The rates includes taking down old light fitting and providing suitable necessary ladders /equipments for any height for taking down the items.
S&F in repairs flame proof LED well glass hanging type 100w fitting on existing light point with suitable hanging arrangements one light control with one MCB SP, complete all as specified and directed. Note:The rates includes taking down old light fitting and providing suitable necessary ladders /equipments for any height for taking down the items.
S&F in repairs HIGH BAY LED lights hanging/ceiling mounting type 100w fitting with PC diffuser with surge protection on existing light point with suitable hanging arrangements one light control with one MCB SP, complete all as specified and directed. Note:The rates includes taking down old light fitting and providing suitable necessary ladders /equipments for any height for taking down the items.
S&F repairs LED recess/surface mounted 2"x2" luminarie 36/40w fitting, 220V,AC, 50 Hz,suge protection, high power factor complete all as specified and directed b
S&F in repairs Low BAY LED lights hanging/ceiling mounting type 40w fitting with PC diffuser with surge protection on existing light point with suitable hanging arrangements for one light control with one MCB SP, complete all as specified and directed. Note:The rates includes taking down old light fitting and providing suitable necessary ladders /equipments for any height to taking down the items.
S&F in repairs FLP plugin switch socket 16A , 3pin (2P+E) , 220V, 50 Hz ,AC and fixing arrangement complete all as specified and directed
S&F in repairs FLP plugin switch socket 25A , 3pin (2P+E) , 220V, 50 Hz ,AC and fixing arrangement complete all as specified and directed.
S&F in repairs FLP plugin switch socket 32A , 5pin (4P+E) , 50 Hz ,AC and fixing arrangement complete all as specified and directed
S&F in repairs FLP LED Type tube light fitting 1X 20 watt ,four feet ,220V , 50 Hz ,AC and fixing arrangement complete all as specified and directed b
S&F in repairs FLP LED Type tube light fitting 2X 20 watt ,four feet ,220V , 50 Hz ,AC and fixing arrangement complete all as specified and directed
S&F in repairs FLP TPN DB 4 way,220V , 50 Hz ,AC and fixing arrangement incomer MCB 4P 63amp/100 Amp and outgoing MCB SP suitable nos bus bar 200 Amp complete all as specified and directed.
S&F in repairs FLP SPN DB 12 way,220V , 50 Hz ,AC and fixing arrangement incomer MCB 2P and outgoing MCB SP suitable nos bus bar 100 Amp complete all as specified and directed.
S&F in repairs MCCB 4 pole, thermal magnetic release range 100 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed.
S&F in repairs MCCB 4 pole, thermal magnetic release range 125 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed.
S&F in repairs MCCB 4 pole, thermal magnetic release range 63 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed.
S&F in repair/replacement MCCB 4 pole, thermal magnetic release range 40 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified.
S&F in repairs 6 to 32 AMP MCB single pole 240 V 10 KA (C-Series) complete complete all as specified and directed.
S&F in repairs 32 AMP MCB SPN 240 V 10 KA (C-Series) complete complete all as specified and directed.
M & L checking ceiling fan of size 1200/1400mm and change defective part cotter pin/ nut bolt etc including taking down and refixing complete all as specified and directed.
M&L cutting of wall/ceiling/column for laying submain/ cable of suitable size including plastering ,and making good as per existing complete all as specified and directed.
S&F in replacement fan rod of size 1/1.5 feet suitable for mounting ceiling fan of size 1200/1400 mm complete all as specified and directed.
Supply only capacitor of 2.5 mfd complete all as specified and directed.
Supply only capacitor of 4.0 mfd complete all as specified and directed.
M&L for Rewinding of ceiling fan 1200/1400mm with sutable size copper winding wire as per existing complete all as specified and directed.
M&L checking Exhaust fan of size 250/300/450mm and change defective part including taking down and refixing acomplete all as specified and directed.
M&L for Rewinding of Exhaust fan 250/300/450mm with sutable size copper winding wire as per existing complete all as specified and directed.
M&L for checking wall mounting fan of size 300/450/600mm and change defective part including taking down and refixing complete all specified and directed in charge.
M&L for Rewinding of wall mounting fan of size 300/450/600mm with sutable size copper winding wire as per existing complete all as specified and directed.
M&L for checking Pedastal fan of size 300/450/600mm and change defective part including taking down and refixing complete all as specified and directed.
M&L for rewinding of Pedastal fan of size 300/450/600mm with suitable size copper winding wire as per existing complete all as specified and directed.
S&F in repairs LED batten with 20/22W LED tube light four feet box type with hanging arrangement in wall/surface/ceiling connecting with all required accessories like PVC box base,flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as specified and directed.
S&F in repairs LED batten with 20/22W LED tube light (4") , 220V,AC ,50Hz in wall/surface connecting with all required accessories like PVC box base,flexible cable from ceiling rose etc,suge protection, high power factor, Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as specified and directed.
S&F in repairs round/square type, recessed /surface 12W/14W warm /white LED downlight dimmable with high lumen 230V, compatible with Legrand Dimmer as per sample complete all as specified and directed.
S&F switch piano flush button single pole one way, 6 Amp (ISI marked) complete all as specified and directed
S&F Switch socket outlet 2 in 1, 3 pin, 6 Amp flush type (ISI marked) complete all as specified and directed
S&F Socket outlet 2 in 1, 3 pin, 6 Amp flush type (ISI marked) complete all as specified and directed
S&F Switch socket outlet 15 Amp, 5-in-1, controlled by one switch (ISI marked) complete all as specified and directed
S&F Socket type EME fan 5 step regulator for ceiling fan of suitable size, complete all as specified and directed
S&F modular step type fan regulator ISI 120W,AC,50Hz complete all as specified and directed
S&F modular switch 1 module 6 amp one way complete all as specified and directed
S&F modular switch 1 module 16 amp one way complete all as specified and directed .
S&F modular socket 2 module universal type 5/6 amp one way complete all as specified and directed .
S&F modular socket 2 module universal type 15/16 amp one way complete all as specified and directed .
S&F modular bell push 6A 1 module complete all as specified and directed.
S&F ceiling rose three terminal complete all as specified and directed
S&F in repair LED tube rod 20 watt ,220V,50Hz,AC change with existing tube rod complete all as specified and directed
S&F repair FLP junction box 4 way 100mm including all connected accessories complete all as specified and directed. Note :- BOQ Serial item No 1.48 to 1.61, These items shall also be used as in repairs as per site requirement nothing extra shall be paid.
Taking down carefully by unscrewing from ceiling flame proof HPMV lamps, HPSV lamp alongwith flame proof control gear box etc and after dismantling secure wiring with steel conduit upto distribution board to operate one light with one MCB ,switch,socket,regulator , ceilng rose etc complete, if any light needs wiring for connection after removing gear box the cotractor will done the wiring with wire and accessories such as bend, jucntion box, boards, elbows etc at any height and making good disturbed surfaces of walls floors etc complete all as specified and directed
S&F in repairs double door MCB VTPN DB 4 WAY made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar 4 way ,complete all as specified and directed
S&F in repairs double door MCB TPN DB 4 WAY made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar 4 way ,including taking out old unsv MCB DB any size/type.
S&F in repairs double door MCB VTPN DB 8 WAY made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar 4 way complete all as specified and directed
S&F in repairs double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar 12 way double door open able, complete all as specified and directed
S&F in repairs double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar 8 way double door open able, complete all as specified and directed
S&F repairs PCB of BLDC fan of any size complete all as specified and directed.
S&F repairs remote of BLDC fan of any type complete all as specified and directed.
S&F in repairs of old existing sunken/terminal box of suitable thickness & size 10x10cm, cocealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls complete all as specified and directed.
S&F in repairs of old existing sunken/terminal box of suitable thickness & size 15x7.5cm, cocealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls complete all as specified and directed.
S & F in repairs of old existing sunken/terminal box of suitable thickness & size 20x15cm, cocealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls complete all as specified and directed.
S&F in repairs of old existing sunken/terminal box of size 20x25cm, concealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls complete all as specified and directed.
S&F in repairs modular cover plates with frame up 1 /2 module as per site requirements complete all as specified and directed.
S&F in repairs modular cover plates with frame up 3 module as per site requirements complete all as specified and directed.
S&F in repairs modular cover plates with frame up 4 module as per site requirements complete all as specified and directed.
S&F in repairs modular cover plates with frame up 6 module as per site requirements complete all as specified and directed.
S&F in repairs modular cover plates with frame 8 module as per site requirements complete all as specified and directed.
S&F in repairs modular cover plates with frame 12 module as per site requirements complete all as specified and directed.
S&F in repairs modular metal flush box as per site requirements 1/2 modules complete all as specified and directed.
S&F in repairs modular metal flush box as per site requirements 4 modules complete all as specified and directed.
S&F in repairs modular metal flush box as per site requirements 6 modules complete all as specified and directed.
S&F in repairs modular metal flush box as per site requirements 8 modules complete all as specified and directed.
S&F in repairs modular metal flush box as per site requirements 12 modules complete all as specified and directed.
M&L earthing complete with GI earth plate electrode of size 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 32 x 6 mm by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4) , type B1, using (20 mm graded stone aggregate), mild steel angle iron frame made out of MS angle iron of size 40x40x6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20 mm dia medium grade pipe for watering ,40 mm dia light grade GI pipe for lead protection in & including alternate layers of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part-1(2009) connected to earthing test point all as specified and indicated including testing on completion Note : (i) The unit rate includes for protection pipe and GI strip from top of earth plate up to 7.5 meter above ground level and also the cost of the Test point. (ii) Joining of GI earth strip with pipe of the test point shall be done by using suitable cable lugs.
S&F in repairs FLP FLEXIBLE metalic pipe for 19/20 mm dia fixed on directed place complete all as specified and directed.
S&F in repairs cable of 10X2 sqmm complete all as specified and directed.
S&F in repairs FLP FLEXIBLE metalic hose conduit 1000 mm long for 19/20 mm dia fixed on directed place complete all as specified and directed.
S&F in repairs FLP rotary switch single pole 16 Amps and fixing arrangement complete all as specified and directed
S&F in repairs LED flame proof bulk head fitting 45w with all accessories complete all as specified and directed
S&F in repairs flame proof LED flood light 100w fitting , fitted on wall surface complete all as specified and directed. Note:The rates includes taking down old light fitting and providing suitable necessary ladders /equipments for any height to taking down the items.
S&F in repairs LED batten with 20/22W LED tube light six feet box type with hanging arrangement in wall/surface/ceiling connecting with all required accessories like PVC box base,flexible cable from ceiling rose etc Surface and wall mounted LED batten, , Engineering plastic batten with accessories complete all as directed and specified.
S&F in repairs LED building security light 45 watt with hanging arrangement in wall/surface/ceiling connecting with all required accessories like PVC box base,flexible cable from ceiling rose etc Surface and wall mounted LED batten, , Engineering plastic batten with accessories complete all as directed and specified.
M&L for point wiring for one light point controlled by 1 way switch with 1.5 Sqmm single core, multi stranded copper conductor 1100 V grade, ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLSH cable drawn in casing caping of 25 mm wide, with double locking type, ISI marked including all accessories casing caping as approved by EIC, with PVC 1.5 mm multi stranded insulated unsheathed FRLSH copper wire, ISI marked of green colour for continous earth, including sunken box made out of suitable thickness and not less than 60 mm in depth GI/MS/ prssed steel terminal box to be conclead in wall, duly painted including 3mm hylum /masonite sheet cover, for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer complete all as specified and directed. Note : Wiring to be done as per arroved colour code.
All as per BOQ Serial item no 1.94 above but One light point controlled by 2 way switch SP, 5 Amp, 240 Volts
All as per BOQ Serial item no 1.94 above but one 5 amp socket point on same board
All as per BOQ Serial item no 1.94 above but one 5 amp multi socket indepenedent
All as per BOQ Serial item no 1.94 above, but using 2.5 sqmm ( nominal area) multistranded FRLS copper conductor cable/wire & 2.5 sqmm size PVC insulated unsheathed copper conductor cable for earth continuity ( green colour) for one 5 pin socket outlet 5 / 15 Amp multi purpose independent point controlled by 15 Amp switch, SP one way, 240 Volts & Socket, complete all as specified and directed.
All as per BOQ Serial item no 1.94 , but using 4 sqmm (nominal area) multistranded copper conductor cable/wire for one 5/15 Amp socket point controlled by 15 Amp switch, SP one way 240 Volts & Socket, complete all as specified and directed.
Taking down carefully copper /aluminium point wiring (light, fan socket or power) through stove enamelled steel conduit/pvc conduits including complete fittings such as switches, ceiling roses, pendants, regulators, sockets,, switch sockets, electrical fittings etc removing and making good disturbed surfaces of walls/ceiling etc, all as specified and directed.
M& L for daily complaint checking & repairing of DBs/meter panel board/circuits/submain wiring/switches/sockets etc and other connected work including rectification of faults by employing suitable electrician & helper complete all as specified and directed
M.K Enterprises (BID ID -3101300)
Om Sai Enterprises (BID ID -3101564)
ENJOY (BID ID -3102428)
Shri Krishna Trading Corporation (BID ID -3100301)
Sagar Electricals (BID ID -3098513)
ELECTRO ASSOCIATES (BID ID -3098358)
somnath engineering corporation (BID ID -3100435)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .