Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.7 LAccepted-AOC | L1 | Accepted-AOC Due to lowest bid | |
| 2 | L2₹18.1 L+₹3.0 L (19.5%)Rejected-Finance | L2 | Rejected-Finance Due to higher bid | |
| 3 | L3₹18.4 L+₹3.3 L (21.8%)Rejected-Finance | L3 | Rejected-Finance Due to higher bid | |
| 4 | L4₹21.6 L+₹6.5 L (42.9%)Rejected-Finance | L4 | Rejected-Finance Due to higher bid | |
| 5 | L5₹22.9 L+₹7.8 L (51.5%)Rejected-Finance | L5 | Rejected-Finance Due to higher bid |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
7 Mar 2024, 6:00 pmClosed
GE (WEST) FEROZEPUR CANTT
GE (WEST) FEROZEPUR CANTT
REPAIR TO SUMMER APPLIANCES AND CERTAIN EM WORKS UNDER GE (WEST) FEROZEPUR CANTT
2024_MES_638883_1
802023/GE-73/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
FEROZEPUR CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (WEST) FEROZEPUR CANTT
₹50,000
Yes
24 Apr 2024
16 Feb 2024
14 Mar 2024
16 Feb 2024
7 Mar 2024
1 Mar 2024
Amount
WATER COOLER STORAGE TYPE Taking out existing compressor unit from the water cooler of capacity 40/80/120/150 litre of any make including removed of all other unserviceable parts/spares such as strainers, filter, capillary tubes suction /discharge pipe, thermostat switch, float valve, push cock running , starting capacitor, over load relay complete all as specified and directed.
S&F company repaired compressor in lieu of defective compressor to water cooler of 150 litre/hour cooling capacity including Painting, jointing capillary tube and testing the compressor complete all as specified and directed.
All as per Srl No. 2 here-in-before but of cooling capacity 60 litre/hour.
All as per srl no. 2 here-in-before but of cooling capacity 40 litre/hour.
S&F new compressor to water cooler of 150 litre/hour cooling capacity including, jointing capillary tube and testing the compressor complete all as specified and directed. Makes : Tecumseh /Copeland/Bluestar/Godrej/GMCC
S&F new compressor to water cooler of 60 litre/hour cooling capacity including, jointing capillary tube and testing the compressor complete all as specified and directed. Makes : Tecumseh /Copeland/Bluestar/Godrej/GMCC
S&F new compressor to water cooler of 40 litre/hour cooling capacity including, jointing capillary tube and testing the compressor complete all as specified and directed. Makes : Tecumseh /Copeland/Bluestar/Godrej/GMCC
M&L servicing of water cooler any size and make including drain out water cleaning of water tank and cleaning of condersor coil with anti scaling solution complete all as specified and directed.
M&L charging of water cooler with R-134a,R-22,R-290,R-410 gas complete including leakage test and testing of water cooler on full load for 24 hrs continuously at site of any Make of any capacity complete all as specified and directed.
M&L repairing the water cooler / body by replacing rusted MS sheet body with new MS sheet of 16 SWG approx area 2.5 Square feet complete including replacement of unserviceable channel legs, fan motar base complete all as specified and directed.
Taking out existing unserviceable fan motor of capacity 1/8 HP from water cooler, dismantling the motor and taking out old burnt copper winding wire, rewinding of fan motor with similar size super enamelled copper winding wire after providing 'E' class insulation material complete including replacement of unserviceable pad MS clamps, nut and bolt, varnishing & refixing the motor in the water cooler and testing of water cooler complete all as specified and directed.
Supply, fixing and connecting in replacement new fan motor of water cooler capacity 1/8 HP 230 Volts 50 c/s complete all as specified and directed. Makes: MIE/Khaitan/ Crompton Greaves
S&F in replacement of fan blades of fan motor of water cooler of make sidwal of capacity 150 litre made out of GI sheet complete all as per existing shape and size complete all as specified and directed.
Supply, fixing and connecting the Running capacitor 36 MFD of water cooler of capacity 120/150 litre complete all as specified as directed. Makes : USHA/UNISTAR/TIBCON/Havells/Hightech or equivalent.
All as per srl item 14 here-in-before but Starting capacitor 80-100 MFD.
All as per srl item 14 here-in-before but Over load protector as per sample.
All as per srl item 14 here-in-before but Starting relay 1/8 HP as per sample.
All as per srl item 14 here-in-before but Thermostat switch for water cooler as per sample.
All as per srl item 14 here-in-before Push cock brass HD chromium plated.
All as per srl item 14 here-in-before but float valve ½” dia, brass with ball.
All as per srl item 14 here-in-before but Rubber hose pipe/ for 1 ½” dia and 1.5 m long drain pipe.
All as per srl item 14 here-in-before but Over load/relay complete box type Y-412.
REFRIGIRATOR 310 litre Taking out existing compressor unit from the refrigerator of any capacity, of any make including removed of all other unserviceable parts/spares such as over load relay, bulb, strainer, thermostate switch, bulb holder, capillary tubes, freezer door complete all as specified and directed.
Taking out existing compressor unit from the deep freezer of any capacity of any make including removed of all other unserviceable parts/spares such as over load relay, bulb, strainer, thermostate switch, bulb holder, capillary tubes, freezer door complete all as specified and directed.
S&F only company repaired compressor in lieu of defective compressor to refrigerator of 180/165 litre capacity including jointing capillary and testing the compressor complete all as specified and directed.
S&F only company repaired compressor in lieu of defective compressor to refrigerator of 310/280 litre capacity including jointing capillary and testing the compressor complete all as specified and directed.
S&F company repaired compressor in lieu of defective compressor to deep freezer of 200/250 litre capacity including jointing capillary and testing the compressor complete all as specified and directed.
S&F company repaired compressor in lieu of defective compressor to deep freezer of 300/400 litre capacity including jointing capillary and testing the compressor complete all as specified and directed.
S&F new compressor to refrigerator of capacity 310 litre including, jointing capillary tube and testing the compressor complete all as specified and directed. Makes : Tecumseh /videocon//Godrej/Whirlpool/LG
S&F new compressor to refrigerator of capacity 195/165 litre including, jointing capillary tube and testing the compressor complete all as specified and directed. Makes :Tecumseh /videocon//Godrej/Whirlpool/LG
S&F new compressor to Deep freezer of capacity 320 litre including, jointing capillary tube and testing the compressor complete all as specified and directed. Makes : Tecumseh /Hittchi/Bluestar/Godrej/LG/Copland
S&F new compressor to Deep freezer of capacity 250 litre including, jointing capillary tube and testing the compressor complete all as specified and directed. Makes : Tecumseh /Hittchi/Bluestar/Godrej/LG/Copland
Charging of gas in Refrigerator/Deep Freezer with R-134a,,R-290,R-410 & R-600 gas complete including leakage test and testing of water cooler on full load for 24 hrs continuously at site of any Make of any capacity complete all as directed
Supply, fixing and connecting Plunger type relay 1/6 HP of REFRIGERATOR complete all as specified and directed.
All as per ser item No. 34 here-in-before but Over load protector 1/6 HP.
All as per ser item No. 34 here-in-before but Thermostat switch with knob - u-50-1018.
All as per ser item No. 34 here-in-before but Glass cover heavy duty of Refrigerator capacity 310 litre.
All as per ser item No. 34 here-in-before but Repair to Freezer door for Refrigerator of Cap 310 litre.
All as per ser item No. 34 here-in-before but Timer controller for Double door Refrigerator of Cap 310 litre.
All as per ser item No. 34 here-in-before but Heating Elemnet for Double door Refrigerator of Cap 310 litre.
All as per ser item No. 34 here-in-before but BioMetal for Double door Refrigerator of Cap 310 litre.
All as per ser item No. 34 here-in-before but Sensor for Double door Refrigerator of Cap 310 litre.
S&F PCB unit of Double Door Refrigertor 310/400 litres of existing make complete all as specified and directed.
S&F Butter box / any try any type and size as per sample complete suitable for whirlpool/Samsung refrigarater of Cap 310 litre.
Supply, fixing and connecting the Running capacitor 06-15 MFD of Refrigerator/ Deep Freezer of capacity 120/150 litre complete all as specified and directed. Makes : USHA/UNISTAR/TIBCON/Havells/Hightech
Supply, fixing and connecting, Replacement of the existing damage, choked Backside Condensor Coil from the Refrigerator of Cap 165/195 litre of any Make complete all as specified and directed.
Supply, fixing and connecting, Replacement of the existing damage, choked evaporator (Freezer) from the Refrigerator of Cap 310 litre of any Make complete all as specified and directed.
All as per ser item No. 47 here-in-before but Replacement of the existing damage choked evaporator (Freezer) from the Refrigerator of Cap 165 litre of any Make.
Repairing the Refrigerator /Deep Freezer body by replacing rusted MS sheet base with new MS sheet of 16 SWG approx area 2.5 Sq ft complete including replacement of unserviceable channel legs, fan motar base complete all as specified and directed.
Taking out exiting unserviceable fan motor of capacity 1/8 HP from the cooler/Deep freezer/Refrigerator dismantling the motor and taking out old burnt copper winding and rewinding of blower motor with similar size of super enameled copper winding wire after providing 'E' class insulator material including replacement of bushes, name pad and varnishing refixing the motor in the DF Ref and testing of Desert Cooler complete all as specified and directed.
Taking out exiting unserviceable fan motor of capacity 1/8 HP from the cooler/Deep freezer/Refrigerator dismantling the motor and connecting new fan motor & Fan Blade complete all as specified and directed.
AIR CONDITIONER WINDOW TYPE 1.5 TON CAP Taking out existing serviceable window type Air conditioner of capacity 1.5 Ton of any make and capacity and refixing the same to its position after serviceing with anti scaling solution and cleaning complete including removal of all other unserviceable parts/spares such as strainer, pillar suction, starting capacitor overload Running capacitor relay etc and replaced with new parts as required complete all as specified and directed.
All as per ser item No. 52 here-in-before but split type Air Conditioner of capacity 1.5 Ton.
S&F company repaired compressor in lieu of defective compressor to Air Conditioner of 1.5 Ton capacity including jointing compressor, capillary, copper tubing as required and testing the compressor complete all as specified and directed..
S&F new compressor in lieu of defective compressor to Air Conditioner of 1.5 Ton capacity including jointing compressor, capillary, copper tubing as required and testing the compressor complete all as specified and directed. Makes : Tecumseh /Bluestar/Godrej/Hittchi/Whirlpool
S&F new compressor in lieu of defective compressor to Air Conditioner of 2.0 Ton capacity including jointing compressor, capillary, copper tubing as required and testing the compressor complete all as specified and directed. Makes : Tecumseh /Bluestar/Godrej/Hittchi/Whirlpool
S&F in replacement of copper tubing for split type Air conditioner of 1/4 ", 1/2" or any size required at site including insulation pipe complete all as specified and directed.
M&L charging of gas in Split/Window AC with R-134a, R-22,R-32 & R-410 gas complete including leakage test and testing of water cooler on full load for 24 hours continuously at site of any Make of any capacity complete all as directed.
Dismantling taking out existing unserviceable fan motor of capacity 1/8 HP from window type Air conditioner/Split type dismantling the motor and taking out old burnt copper winding wire and rewinding of fan motor with similar size super enamelled copper winding wire after providing 'E' class insulation material complete including replacement of unserviceable rubber pad MS clamp nut bolt varnishing and refixing the motor in the A/C and testing of Air conditioner complete all as specified and directed.
S&F outer unit of spilt type AC 1.5 Tonn of existing make complete with condenser coil and compressor etc complete all as specified and directed.
S&F inner unit of spilt type AC 1.5 Tonn of existing make complete all as specified and directed.
S&F PCB unit of spilt type AC of existing make complete all as specified and directed.
M&L repair of existing unserviceable PCB unit of spilt type AC of existing make complete all as specified and directed.
M&L repair of existing unserviceable PCB unit of invertor type spilt AC of existing make complete all as specified and directed.
S&F in replacement of condenser/Evaporator coil of window type AC of 1.5 TR capacity of any make complete all as specified and directed.
S&F in replacement of condenser/Evaporator coil of split type AC of 1.5 TR capacity of any make complete all as specified and directed.
Supply, fixing and connecting running capacitor 36-50 MFD complete all as specified and directed.
All as per ser item No. 67 here-in-before but Over Load protector No SR-1622 complete all as specified and directed.
All as per ser item No. 67 here-in-before but Starting capacitor 80-100 MFD.
All as per ser item No. 67 here-in-before but Starting Relay box type 1/8 HP SR-1622 complete all as specified and directed.
Supply, fixing and connecting new fan motor 1/8 HP 230 Volts 50 C/s single phase complete including MS clamps and rubber pad, Fan Blade including taking out existing unserviceable fan motor from the Air conditioner complete all as specified and directed.
M&L shifting of air conditioner split type of any make from its original position to another position with and including any B&R work reqd and electric work required for it complete all as specified and directed.
M&L shifting of air conditioner window type of any make from its original position to another position with and including any B&R work and electric work required for it complete all as specified and directed.
DESERT COOLER Taking out exiting unserviceable fan motor of capacity 1/8 HP from the desert cooler/ dismantling the motor and taking out old burnt Aluminium winding and rewinding of blower motor with similar size of super enamelled Aluminium winding wire after providing 'E' class insulator material including replacement of bushes, Name pad and varnishing refixing the motor in the Desert Cooler and testing of Desert Cooler complete all as specified and directed.
Taking out existing unserviceable Tulu pump (water pump) from the desert cooler S&F connecting new Tulu pump 1/20 HP 230 Volt 50 C/S single phase of ISI Marked complete all as specified and directed.
Taking out existing unserviceable fan motor from the desert cooler supply fixing and connecting new fan motor 1/8 HP 230 Volt 50 C/s single phase complete including MS clamps and rubber pad complete all as specified and directed.
Replacement of Desert Cooler front show grill made of PGI sheet 20 gauge duly painted all as specified and directed.
Replacement of Desert Cooler sides Shutters (Set of 3) made of PGI sheet 20 gauge with pad sporting frame of size duly painted complete all as specified and directed.
Replacement of capacitor 4 MFD, 230 Volts 50 c/s of complete all as specified and directed.
Replacement of 3 way PVC distributer complete all as specified and directed.
Taking out unserviceable fan blades and S&F new blade of fan motor from the desert cooler standard quality as per existing size including taking down old unserviceable fan blade complete all as specified and directed.
Taking out existing serviceable fan motor and Tulu pump from the unserviceable body of desert cooler carefully supply of desert cooler body made out of GI sheet 18 gauge duly painted complete including shutters front show grill made out of GI sheet, wooden wool pad and refixing the fan motor and Tulu pump and testing complete all as specified and directed.
M&L painting of desert cooler body at site of any make and capacity with one coat of approved quality synthetic enamelled paint over a coat of red oxide primer after cleaning of dust rust and preparation of surface both inside and out side complete all as specified and directed.
S&F PVC pipe 15mm dia in each cooler complete all as specified and directed.
Taking out unserviceable supporting leg fan motor with screw and fixing new supporting legs as per existing size complete all as specified and directed.
Replacement of wood wool pad, supporting wire frame (set of three) and fixing in water cooler all as specified and directed.
REPAIR TO VOLTAGE STABILIZER OF CAPACITY 5 KVA MAKE - INTEG/NAYAR/ BLUE LINE COMPRISING THE FOLOWING: Dismantling and opening of main transformer and taking out of old burnt Aluminium winding wire, rewinding of main transformer with supper enamelled copper wire after provisioning 'E' class insulator material varnishing and refixing complete all as specified and directed.
S&F of new printed circuit board complex with condenser choke pre fixer and time delay relay including taking down old unserviceable printed circuit board complete all as specified and directed.
S&F Volt meter Display 0-300 Volts single phase 230 Volts complete all as specified and directed. Make: Bajaj/Crompton/GEC
S&F Bakelite connector in main connection lead complete all as specified and directed.
REPAIR TO VOLTAGE STABILIZER OF CAPACITY 4 KVA OF MAKE - INTEG/ NAYAR/ ELECTRON COMPRISING OF FOLLOWING:- Dismantling and opening of main transformer and taking out of old burnt Aluminium winding wire, rewinding of main transformer with supper enamelled copper wire after provisioning 'E' class insulator material varnishing and refixing complete all as specified and directed.
S&F of new printed circuit board complete with condenser dioel pre fixer and time delay relay including taking down old unserviceable printed circuit board complete all as specified and directed.
S&F Bakelite connector in main connection lead complete all as specified and directed.
S&F Volt meter Display 0-300 Volts single phase 230 Volts complete all as specified and directed. Makes : Bajaj/Crompton/GEC
REPAIR TO VOLTAGE STABILIZER OF CAPACITY 3 KVA MAKE- ELECTRON COMPRISING THE FOLLOWING :- Dismantling and opening of main transformer and taking out of old burnt Aluminium winding wire, rewinding of main transformer with supper enamelled copper wire after provisioning 'E' class insulator material varnishing and refixing complete all as specified and directed.
S&F Volt meter Display 0-300 Volts single phase 230 Volts complete all as specified and directed. Make: Bajaj/Crompton/GEC
S&F Voltage stabilizer with 100% copper winding for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stabilized at 230 Volts with accuracy of ± 2.5% and of capacity 5.0 KVA . Make: Microtek/Voltas or equivalent
Taking out carefully existing unserviceable copper PVC flexible 3 core cable and S&F PVC sheathed copper cable 3 core of size 40/ 00.0076 complete all as specified and directed.
Taking out carefully existing unserviceable copper PVC flexible 3 core cable and S&F PVC sheathed copper cable 3 core of size 70/ 00.0076 complete all as specified and directed.
M&L replacement of unserviceable existing reverse valve copper tubing as required on site for AC all as specified and directed.
Servicing and repairing of Aqua Guard water purifier of any cap with replacement of following parts of Make :- Aqua guard, Kent : (a) Primary filter Small
(b) Primary filter Long
(c) Carbon In Line Candle
(d) Inline Sediment Candle
(f) Long CTO Candle
(h) Booster Pump 100 gpd
(h) Booster Pump Head
(j) SMPS Power Supply
(k) Solenoidal Valve Copper
(l) 100 GPD membrane
(o) PVC pipe gripper at Primary filter ( set of two)
(p) Replacement of Float Valve switch
(q) PVC pipe of 1/4" as per exiting size
(r) Primary filter case with clamps
(s) Membrane Hosing A per Existing size
M/S CHAWLA CONSTRUCTION COMPANY
PAWAN KUMAR GOVT. CONTRACTORS
HAPPY ELECTRICALS
M/S Pee Kay Builders
MN BUILDERS
M/S Sandhu Const.Co.
B.L. Chaudhri and Co.
M/s G N Const. Co.
Marwaha Builders
shivam builders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .