Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹25.4 L+₹21,451.20 (0.85%)Rejected-Finance HN 2 PREETI NAGAR PHASE II FAIZULLAGANJ LUCKNOW UTTAR PRADESH 226020 | LUCKNOW | UTTAR PRADESH | 226020 | L2 | Rejected-Finance Not being lowest bidder | |
| 3 | L3₹27.4 L+₹2.1 L (8.43%)Rejected-Finance | L3 | Rejected-Finance Not being lowest bidder | |
| 4 | L4₹27.5 L+₹2.3 L (9.15%)Rejected-Finance | L4 | Rejected-Finance Not being lowest bidder | |
| 5 | L5₹28.3 L+₹3.1 L (12.3%)Rejected-Finance | L5 | Rejected-Finance Not being lowest bidder |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
12 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR/MAINT OF LT INFRASTRUCTURE AT BASE HOSP AREA, CMDC AREA, SHO AREA, ECHS AREA, OFFICERS MESS AT CHCC AND CMDC INCL BARRACKS BLDG NO 18, 19, 20 AND TUSKAR LINE UNDER GE E/M LUCKNOW
2020_MES_375435_2
GE/EM/LKO/HOSP/T-46 OF 2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
Class D or above category b (i)
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹96,000
Yes
10 Dec 2020
22 Oct 2020
14 Nov 2020
22 Oct 2020
12 Nov 2020
31 Oct 2020
60 days
Amount
Supplying and laying or fixing in replacement, jointing and testing LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 10 sqmm cross sectional area, 2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers complete all as specified and as directed by Engineer -in-Charge. Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items.
All as per item No 1 above but of size 10 Sqmm 4 core
All as per item No 1 above but of size 16 Sqmm 4 core
All as per item No 1 above but of size 25 Sqmm 3.5 core
All as per item No 1 above but of size 50 Sqmm 3.5 core
All as per item No 1 above but of size 95 Sqmm 3.5 core
All as per item No 1 above but of size150 Sqmm 3.5 core
All as per item No 1 above but of size185 Sqmm 3.5 core
S&F Straight through joints (Heat Shrink Kits) 3.5 core cable 25 to 50 Sq mm size for LT underground cable indoor/outdoor type complete for Armoured ,PVC sheathed Aluminium conductor cables Including excavating earth, identifying the fault, making proper joint of cable after rectification & returning soil back to earth, complete all as specified and as directed by Engineer -in-Charge.
All as per item No 9 above but 3.5 core cable 70 to 150 Sq mm
All as per item No 9 above but 185 sqmm to 300 sqmm 3 ½ core
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and as directed by Engineer -in-Charge.
Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and as directed by Engineer -in-Charge.
Removing excavated material ( soils) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed by Engineer -in-Charge
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete all as specified and as directed by Engineer -in-Charge . Note :- Punned thickness shall only be considered for payment
M&L laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified and as directed by Engineer -in-Charge .
Boring/Drilling ( horizontally) manually under existing road ( maximum 10 M in width) suitable for passing GI tubing of 40 to 80 mm bore complete all as specified and as directed by Engineer -in-Charge.
S & F GI tubing 'Light' grade 40 MM for cable protection fixed in poles/walls/laid under roads/crossing etc incl taking out the rusted pipes complete all as specified and as directed by Engineer -in-Charge .
All as per item No 18 above but size 50 mm bore dia
Labour for taking out the unserviceable / faulty cable after meggering , finding the fault , cutting the cable , jointing with jointing kit using extra cable if required ,relaying of cables upto 150 sqmm 3.5 core ,connecting, rate included of excavation works, using old bricks complete all as specified and as directed by Engineer -in-Charge Note :, cable joints will be measured and paid seperatly under respectrive item of schedule.
Material & Labour for preparation of old painted surface of steel tubular pole (9/11/12) meter long above coping) and applying two coat of aluminium paint, making of strip of 20 cm width (sky blue and white in alternate band) upto 1400 mm height with one synthetic enamel paint , rewriting pole No by painter with enamel paint, and painting the existing MS clamp with one coat of aluminum paint complete all as specified and as directed by Engineer -in-Charge
Material and labour for writting of Pole Nos on existing pole with stencil out with white colour in sky blue colour background of 80 mm hight around the radius of pole and complete all as specified and as directed by Engineer -in-Charge
Supplying and fixing in repair flat twin core ,1.5 sqmm nominal cross sectional area multistranded aluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulated and PVC sheathed complete all as specified and as directed by Engineer -in-Charge
Supplying and fixing in repair flat twin core ,2.5 sqmm nominal cross sectional area multistranded aluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulated and PVC sheathed complete all as specified and as directed by Engineer -in-Charge
Supplying and fixing in repair flat twin core ,6 sqmm nominal cross sectional area multistranded aluminium conductor FRLS cable, PVC insulated and sheathed 1100 Volts grade complete all as specified and as directed by Engineer -in-Charge
MCCBs four pole 16 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 25 to 100 AMPS complete all as specified and as directed by Engineer -in-Charge
MCCBs four pole 16 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 125 AMPS complete all as specified and as directed by Engineer -in-Charge
MCCBs four pole 16 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 160 AMPS complete all as specified and as directed by Engineer -in-Charge
MCCBs four pole 36 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 200 AMPS complete all as specified and as directed by Engineer -in-Charge
MCCBs four pole 36 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 250 AMPS complete all as specified and as directed by Engineer -in-Charge
MCCBs four pole 36 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 400 AMPS complete all as specified and as directed by Engineer -in-Charge
Power contactor 4 pole Type Mcx 32 , Fr size 2 rating AC 1 rating 160 A, 50HZ including dismantling the unserviceable contactor, complete all as specified and as directed by Engineer -in-Charge
Power contactor 4 pole Type Mcx 23 , Fr size 1 rating AC 1 rating 40A, 50HZ including dismantling the unserviceable contactor, complete all as specified and as directed by Engineer -in-Charge
Digital type Volt meter , 3 ph , class 1 including taking down unserviceable voltmeter, complete all as specified and as directed by Engineer -in-Charge
Digital type Ammeter 3 ph , 5 Amps , class 1 including taking down unserviceable ammeter, complete all as specified and as directed by Engineer -in-Charge
Indicator lamps (LED Type) including taking down unserviceable indicator lamps complete all as specified and as directed by Engineer -in-Charge
S & F in rep MCB’s single pole with neutral, 6 to 32 Amps, 250 volts with 'B"/ ‘C’ curve, fixed in existing PVC box including connecting complete all as specified and as directed by Engineer -in-Charge
Rep/Maint/servicing of LT ACB 4 pole of capacity 1250 Amps 50Ka including rep/maint of minore rep complete all as specified and as directed by Engineer -in-Charge
Dismantling the existing unserviceable ( damaged/broken) LT street light swaged poles / RCC poles or unserviceable tilted steel pole of any size, from ground after necessary excavation etc. and removing the unserviceable poles including making good disturbed ground and deposite in MES store yard complete all as specified and as directed by Engineer -in-Charge
Supplying, transporting, erecting and fixing Steel tubular swaged poles type 410 SP-31 ( 9.0 metres long) complete with cast iron base plate, finial, taper plug, bolts, nuts and screws as specified, including necessary excavation and earth work , PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block , disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting steel tubular poles exposed surafces with Aluminium paint two coats over one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps with synthetic enamel paint and 2 bands with Black bituminous paint ) from plinth block and numbering of poles , painting embedded portion of poles with one coat of bituminous paint complete all as specified and as directed by Engineer -in-Charge
Restreching only existing LT OH/ HT OH lines consisting following lines of ACSR and GI wire , any size and tightening with aluminium binding wire 2/4/5/6 Lines of ACSR and 1 line of GI wire complete all as specified and as directed by Engineer -in-Charge . Note :- (i) Linear length centre to centre of the poles shall only be measured (ii) Cleaning / pruning of tree branches falling around the conductor shall also deemed to be included in the quoted rates
S&F in replacement of .LT bushing with stud, brass terminal 6 Nos.brass nuts and washers, gaskets, insulator etc suitable for 50 KVA TO 300 KVA Transformer complete all as specified and as directed by Engineer -in-Charge
All as per item No. 42 but suitable for transformer of capacity 400 KVA to750 kva
S & F Offload change over switch, 200 Amps, 415 volts, 4 pole in sheet metal enclosure conforming to IS:13947 (Part-3); IEC:60947-3 with locking facility including all connecting/ jointing materials and dismantling of existing change over switch, complete all as specified and as directed by Engineer -in-Charge
S & F On load change over switch, 63 Amps, 415 volts, 4 pole side handle type in sheet metal enclosure conforming to IS:13947 (Part-3); IEC:60947-3 with locking facility including all connecting/ jointing materials and dismantling of existing change over switch, complete all as specified and as directed by Engineer -in-Charge
S & F Off load change over switch (side operated handle) 400 Amps, 415 volts 4 pole in sheet metal enclosure with interlock door and pad lock facility including dismantling of existing change over switch, complete all as specified and as directed by Engineer -in-Charge
Supply fixing testing and commissioning of ( in rep) LT ACB 4 pole of capacity 1250 Amps 50Ka Manual Fixed (MF) Microprocessor Release, Auxiliary Switch 5a 5b5NO+5NC, Main CTs, Terminal Type - Horizontal,upto 2500A & Vertical for 3200A~6300A, Rectifier (24V DC supply) complete all as specified and as directed by Engineer -in-Charge. Note- Old UNSV ACB have depositd in MES store yard
S & F street light panel single phase up to 6 kw load with Astronomical digital timer and MCCB of capacity 32 / TP and SPN 40 Amps fixed on wall/pole with clamps,nuts bolts complete all as specified and as directed by Engineer -in-Charge
MCCBs four pole 36 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 630 AMPS complete all as specified and as directed by Engineer -in-Charge
M&L Earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
M&L Earthing complete with Copper earth Plate electrode 60x60cmx3.15mm thick, burried directly in ground ( earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, Including connected to copper strip 20x3mm lead (upto 7.5 Mtr) by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate connected to earthing test point all as specified or indicated including testing on completion.ith salt to a packed thickness of 15 cm all around the plate, and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
M&L for chemical earting with copper plate size 90x60Cm x 5 mm thick and copper strip of size 50 x 6 mm burried directly in ground vertically toward depth not less than 2.5 mtr below normal ground level(Including 250 Kg charcoal,100 Kg magnesium sulphate crystal) having 25 mm dia pipe of enough length to reach just above copper plate fitted with funnel , mesh along with cap and running water tap to be provided for keeping soil wet, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described complete all as specified and directed and testing on completion. . The set of three chemical pit to be made and connected in a grid to meet the each resistance specific of not more than 0.5 to .90 ohms complete all as specified. Note :- a) Copper plate and copper strip should be brazzed and not to be fastened nut bolt. b) Alternate layer of charcoal and crystal salt should be laid in earth pit on top of copper plate at least 5 layer should be made. c) After laying of 5 alternate layerof charcoal and salt one 2 fit layer of magnesium sulphate is to be laid, balance volume to be filled with soft soil. d) Charcoal ,salt, and magnesium sulphate should not have to be mixed. they are to be laid in layers only ceramic spacer should be provided between copper strip and the wall while extending the earth to the equipment , copper strip is to be extended inside the equipment room and power room It should be routed with inside wall of the ongoing duct fixed with ceramic spacer. e) Depth of pit should not be less than 2.5 mtr and width 1.25 mtr. f) Eathing test point terminal box made of gun metal or phosporus bronze size 75 x 75 x 25 mm drilled and screwed incl 3 Nos 8 mm dia 25 mm long hex head screw. Note :- If the as per standard value of earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department
Ajanta Associates
M K Engineers and Contractors
Prime power system
m/s pal associates
M/S J J ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .