| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 and reasonable | |
| 2 | L2₹28.7 L+₹1.9 L (6.94%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹29.2 L+₹2.3 L (8.69%)Rejected-Finance | L3 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹56,000
Closing Date
4 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) GORAKHPUR
GE(AF) GORAKHPUR Pin-273008
PROVISION OF STORE AT AKASH VIHAR AND ADDITION ALTERATION OF BUILDING NO. 49 AT AF STN GORAKHPUR
2020_MES_384729_1
8732/E8
Open Tender
Civil Works
Item Rate
180 days
GE(AF) GORAKHPUR
As per Tender Documents
7 documents required · 7 mandatory
₹500
Yes
GE(AF) GORAKHPUR
₹56,000
Yes
16 Dec 2020
8 Oct 2020
5 Nov 2020
9 Oct 2020
4 Nov 2020
21 Oct 2020
60 days
Amount
Excavation in trenches in soft/loose soil not exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation filling and mass complete all as specified and directed.
M&L for brick work using old size bricks with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for 15 mm thick rendering on fair faces of brick work or on concrete surface in CM 1:6 finished surface even and smooth without using extra cement complete all as specified and directed.
M&L for 15 mm thick rendering on other than fair faces of brick work or on concrete surface in CM 1:4 finished surface even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of new or previously untreated surfaces of steel of any description, over 10cm in width or girth and apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for RCC 1:1½: 3 type A-1 using 20mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies canopies, deck slabs and in shelves and the like including necessary form work complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Demolition of cement concrete un-reinforced of any position not otherwise specially provided or portion to be ordered complete all as specified and as directed.
M&L for 75mm thick PCC (1:3:6) type C-2 using 40mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10mm wide, 30mm deep joints at the rate of 3.00 mt centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as specified and as directed.
Dismantling cast iron work of any description not otherwise provided for complete all as specified and as directed.
S&F rolled mild steel work in tubular trusses including vertical member, rafter and purline including special shaped washer etc using ERW or induction butt welded tubes conforming to IS 1161-1979 graded st-240 including cutting to dead length, notching, drilling riveting and/or welding & connecting with nuts & bolts complete all as specified and as directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick (BMT) of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixing with self tapping screws complete all as specified and directed.
S&F of Aluminium composite panel 5mm thick of approved colour and texture including fixing material complete all as specified and directed.
S&F Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and directed.
Surface dressing n.exc. 15 cm deep in soft/loose soil incl removal of brick/stone pieces, herbs, shrubs & vegetation and tree cutting in areas of construction complete all as specified and directed.
S&F 60-62mm thick reflective rubber moulded interlocking precast PCC paver, tiles M-35 grade made up with 12.5mm graded mechanically crushed stone aggregate, factory made, of any tint, conforming to IS-15658-2006 over & including 30mm sand cushioning & filling the joints with coarse sand complete all as specified and directed.
Demolition of brick work built in cement mortar including all quoins, pillars etc but excluding ashlar facings, dressed stone work and pre-cast articles complete all as specified and directed.
Taking down cement or cement lime plaster any description incl racking out joints, hacking for keys, scrubbing down with water etc complete all as specified and directed.
M&L for preparing new plastered surface of wall and applying two coat of oil bound distemper and a coat of primer over a coat of 1mm thick Birla putty as base coat complete all as specified and directed.
M&L for preparing new plastered surface of wall and applying two coat of exterior emulsion weather proof paint and a coat of primer over a coat of 1mm thick Birla putty as base coat complete all as specified and directed.
M&L for complete removal of existing treatment by washing, rubbing down and stopping old surfaces of wall including scrapping and applying two coat of exterior emulsion weather proof paint and a coat of primer over a coat of 1mm thick Birla putty as base coat complete all as specified and directed.
M&L for 12mm thick toughened glass as in cup board, shelves including fixing with necessary SS clamps and other material complete all as specified and directed.
M&L for 18-20mm thick pre-polished granite stone slab of approved shade and colour as in kitchen slab. platform, steps, cills etc or on vertical surfaces including vertical projection, rounding or chamfering the edge laid over screed bed 15mm thick in CM 1:4 jointing , pointing and rubbing polish to achieve mirror finish complete all as specified and directed.
Dismantling floor, hearth or wall ceramic tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all specified and directed.
M&L for 25mm thick cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate surface finished fair and even complete all as specified and directed
S&F for light colour vitrified, ceramic tiles of size 600x600x8-10mm thick as in floor etc, set & jointed with in neat cement slurry or with adhesive as per manufacturers instructions & pointed in white/colour cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
All as per item No. 29 above but as in skirting including 10mm thick screed bed in CM 1:6.
Taking down chawkhats or frame with shutter (without taking out shutter from the frame n.exc 1.50 Sqm each and removing from site complete all as specified and directed.
All as per Item No. 31 above but exc 1.50 Sqm and n.exc 4 sqm each.
M&L powder coated anodised aluminium doors (sliding/hanging type) with frame size 101.60X44.45X 2.00 mm thick and shutter aluminium anodised and top rail 47.62X 44.45 X 1.50mm and style 47.5 x 44.5 x1.5 mm , lock rail 83.50X 44.45 X 1.50 mm and bottom rail150.00X 44.50 X 2.50 mm and stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture1.4mm incl necessary aluminium fittings like aluminium butt hinges 04 Nos , aluminium handles 150mm 02 Nos, aluminium tower bolts 200mm 01No, mortise lock 4 lever MS, hydraulic door closer of suitable capacity 01 No, aluminium door stopper 01 Nos, jointing cleats, glazing cleats, rubber packing , anodised aluminium shape beading, screws etc with paneling in two parts with 12mm thick prelaminated particle board in lower panel and 5mm thick tinted glass in upper panels incl all fittings& fixture complete all as specified and directed.
M&L for powder coated anodised aluminium (sliding/ hanging type) windows/ventilator with frame size 60x40x2.00mm thick and shutter with section bearing bottom 25x18x1.50, top 39.4x17.7 X1.50 mm ( suitable for moving over three track fixed over top of frame work, top and side section of size 61.6 x 31.75x1.5mm and bearing bottom track of size 61.6x 31.75x1.5mm or fixing with hinges steel wire cloth 0.36mm nominal dia of wire and average width of aperture1.4 mm including necessary aluminium jointing cleats, glazing cleats, rubber packing anodised shape beading, screws etc with 5mm thick tinted/ plain glass in panels incl anodised aluminium grill with all fittings & fixture complete all as specified and directed .
M&L for non asbestos 4mm thick fiber cement building boards fixed or laid/inserted to aluminium frame work with screws as in false ceiling fixed in ceiling flat or sloping including aluminium anodised snap grid frame work of size 605x605mm for false ceiling with hanging arrangement of 6mm dia G .I. wire (upto 1200 mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40x3 mm size and 60mm long and expansion hold fasteners 12.50mm dia 40mm long complete all as specified and directed.
Taking down carefully copper/aluminium point wiring light/ fan/ bell/socket or power complete (fittings such as switches, sockets, ceiling rose, pendent holders, light fittings etc are to be measured separately) and/or drawing out from existing conduit/batten and making good disturbed surfaces of walls/floors/ ceilings complete all as specified and directed .
M&L for one light/fan point controlled by one switch point wiring with (FRLS) flame retardant low smoke PVC insulated unsheathed cable 1.5 sqmm with multistranded copper conductor, in and including non metallic PVC concealed conduit not less than 20mm dia with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of sunken modular type pressed steel GI terminal boxes of not less than 1.6mm wall thickness, concealed in wall with modular top cover and plate including (FRLS) flame retardant low smoke PVC insulated copper earth conductor 1.50sqmm connected to common earth and earth dolly complete all as specified and directed.
All as per srl item No 37 above but for one socket outlet 3 pin 5 amps independent controlled by one switch but not below the main board in the same vertical plane
All as per srl item No 37 above but for one socket outlet 3 pin 5 amps controlled by one switch on the same board.
All as per srl item No 37 above but for one call bell/buzzer point controlled by one bell push.
M&L for point wiring with (FRLS) flame retardant low smoke PVC insulated unsheathed cable 2.5 sqmm with multistranded copper conductor, in and including non metallic PVC concealed conduit not less than 20mm dia with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of sunken modular type pressed steel GI terminal boxes of not less than 1.6mm wall thickness, concealed in wall with modular top cover and plate including (FRLS) flame retardant low smoke PVC insulated copper earth conductor 1.50sqmm connected to common earth and earth dolly complete for 3 pin 15 Amps socket independent. Note for item Nos 37 to 41 :- (i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface. (ii) Switches, Socket outlet, call bell, bell push and fan regulators shall be measured and paid separately.
S&F modular switch single pole 1 way, 1 module, 6 Amp complete all as specified and directed.
S&F modular socket out let multipurpose 6A -2/3 pin, SP 1 way 2 module complete all as specified and directed.
S&F modular socket out let multipurpose 6A/16A-2/3 pin, SP 1 way 2 module complete all as specified and directed.
S&F modular switch single pole 1 way, 1 module, 16 Amp complete all as specified and directed.
S&F modular fan regulator 240 V electronic step type, 1 module complete all as specified and directed.
S&F modular Bell Push 6A SP 1 way, 1 module complete all as specified and directed.
S&F ceiling rose surface bakelite, 65X50 mm three terminals complete all as specified and directed
S&F Call bell, Ding dong type AC single pole 240 volts complete all as specified and as directed.
S&F lamp holder insulated body with back plate suitable for batten fittings complete all as specified and directed.
S&F in repair wall mounted batten integrated LED plastic channel with tube of capacity 20 Watt (4ft), integral sleek extruded polycarbonate LED channel with white acrylic cover and integrated electronic driver complete fixed/connect properly complete all as specified and as directed. Make:-Model No. Bajaj LED Batten 20W CDL Plastic of Bajaj or equivalent in Havells/Philips/C&S
All as per Item No. 51 above but for capacity 9-10 watt (2ft). Make:-Model No. Bajaj LED Batten 9W CDL Plastic of Bajaj or equivalent in Havells/Philips/C&S
S&F in repair Recessed mounting 2'x2' LED 43 Watts, 5700K, panel light for dust-free installation, white powder coated CRCA housing with LEDs seamless front frame with flat white high transmission acrylic cover etc fixed properly in false ceiling/POP ceiling of suitable reqd dimensions and connecting complete all as specified and as directed. Make : Bajaj Cat Part No : BZRSQL 43W GZ1 WH/CW or BARSQL 43 WH or equivalent in Philips / Havells/C&S.
S&F in repair bldg security light fitting energy saving with pressure die-cast housing IP-66 protection secondary optics, individual high power LED of capacity 120 watt with toughened glass including all connections complete all as specified and as directed. Make: Cat No. BRTFG 120W LED of Bajaj make or equivalent in Havells/Philips/C&S
S&F in replacement of sub main wiring with two single core PVC insulated cable with 4 sqmm nominal cross sectional area stranded copper conductor and one single core green PVC insulated 2.5sqmm stranded copper conductor earth continuity cable drawn through with and including non metallic rigid PVC conduit medium grade 20mm bore including accessories concealed in wall including cutting chases in wall and making good disturbed surface to match of wall/ceiling complete all as specified and directed.
All as per item no. 55 above but PVC insulated cable with 6 sqmm nominal cross sectional area stranded copper conductor and one single core green PVC insulated 4.0 sqmm complete all as specified and directed
Supply & fixing exhaust fan (air freshener) single phase 230/240 volt AC 250mm sweep with louvers, plastic body, including cutting holes of suitable size in wall, grouting of nuts and bolt etc required for fixing fan and making connection with twisted copper flexible wire 23/0.0076mm complete all as directed.
S&F exhaust fan single phase 230/240 volt AC 300mm sweep with louvers, metal body, including cutting holes of suitable size in wall, grouting of nuts and bolt etc required for fixing fan and making good to match the existing surface and making connection with twisted copper flexible wire 23/0.0076mm complete all as directed.
S&F in replacement factory made epoxy powder coated distribution board double door TPN 4 ways (VTPN MCCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, strandard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts and suitable for one FP-MCCB 100/ MCB 63 Amps as incomer and TPN/SP MCBs (or any combination of SP/TP MCBs ) outgoings complete all as specified & directed.
S&F in replacement MCCB 4 pole, 415 volts, 100 Amp capacity of 16 KA breaking capacity complete all as directed.
S&F in replacement factory made epoxy powder coated distribution board SPN 8 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, strandard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates all as specified & directed.
S&F in replacement MCB SP 6 to 32 Amp 240 volts 10 KA breaking capacity 'C' curve complete all as specified and directed.
S&F in replacement MCB SPN 40 Amp 240 volts 10 KA breaking capacity 'C' curve complete all as specified and directed.
S&F in replacement sheet metal enclosures with socket plug top and MCBs with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified.
Excavation in trenches in soft/loose soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out for cable trench complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Supply and providing sand cushioning with dry clean sand 15 cm below cable and 8 cm above the cable complete all as specified and directed. Note: Punned thickness shall be measured for the purpose of payments.
Supply and laying burnt bricks old size sub class-B laid in trenches for cable protection with length of brick perpendicular to length of cable complete all as specified and directed.
S&F of GI pipe 40 mm bore , light grade as in trenches, under road, fixed to wall, with fixing arrangement along the pole, under floor etc complete all as specified and as directed. Note: Excavation and earth work shall be measured and paid separately.
Supply, laying, jointing, testing and commissioning under ground electric cable XLPE 1100 Volts grade, heavy duty, PVC insulated aluminium conductor, of cross section area 50 Sqmm 3.5core stranded, served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape as in trenches over brick and sand cushioning or along the wall/pole through pipe etc including taking down old cable complete all as specified and directed. Note :- Excavation and earth work, GI pipe, brick and sand cushioning shall be measured and paid separately.
Material and labour for earthing complete as in replacement with galvanized steel earth plate 60cmx60cmx6 mm thick buried vertically in ground to depth not less than 2.25 metres below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to earth lead GI 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron and connection to main switch board of panel, including watering pipe GI 20 mm bore light grade, including protection pipe GI medium grade 15mm bore for earthing lead, wire mesh, funnel, salt, charcoal dust, excavation and refilling pit with PCC 1:2:4 type B1, precast RCC cover using XPM reinforcement weighing not less 4kg/sqm in lieu of CI cover and frame all as shown in electric plate of SSR part-I (2009), including testing on completion all as directed.
M/S DELTA ENTERPRISES
M/S NITISH ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .