Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.3 LAccepted-AOC EAST VIVEKANANDA PALLY MANGAL PANDEY SARANI PO RABINDRA SARANI SILIGURI 734 006 WB | JALPAIGURI | WEST BENGAL | 734006 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹49.8 L+₹93,430 (1.91%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | L3₹49.9 L+₹1.0 L (2.08%)Rejected-Finance DESHBANDHUPARA PO SILIGURI TOWN DIST DARJEELING PIN 734004 | JALPAIGURI | WEST BENGAL | 734004 | L3 | Rejected-Finance NOT LOWEST BIDDER | |
| 4 | L4₹50.0 L+₹1.1 L (2.33%)Rejected-Finance SWAMIJI SARANI HAKIMPARA P O SILIGURI 734001 DIST DARJEELING WB | JALPAIGURI | WEST BENGAL | 734001 | L4 | Rejected-Finance NOT LOWEST BIDDER | |
| 5 | L5₹50.1 L+₹1.2 L (2.39%)Rejected-Finance HAKIMPARA NEAR PAKURTALA MORE SILIGURI 734 001 | DARJEELING | WEST BENGAL | 734001 | L5 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
13 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Sukna
Garrison Engineer Sukna, Post-Simulbari, Dist.-Darjeeling, WB-734009
REPAIR/MAINT OF SOLAR WATER HEATER AND GEYSERS AND CONNECTED WORKS SUCH AS PIPE LINE, METAL PLUG ETC AT SUKNA MIL STATION UNDER AGE E/M OF GE SUKNA.
2023_MES_576469_1
GE Sukna/8501
Open Tender
Civil Works
Works
270 days
Sukna
AS PER NIT
8 documents required · 8 mandatory
₹500
GE Sukna
₹90,000
Yes
9 Mar 2023
21 Jan 2023
14 Feb 2023
21 Jan 2023
13 Feb 2023
6 Feb 2023
23 Jan 2023 - 13 Feb 2023
Amount
Taking down and refixing storage type water heater from wall by disconnecting the electric connection and water inlet/outlet connection from main and repairing the water heater storage type capacity 25/35/50 ltrs of any type and make, checking the serviceablity of all parts such as inner vesser, rubber gasket, non return valve, heating element, thermostat etc and refixing the same after replacing of unserviceable parts and assembly completet (considered as one unit) and installing and testing the same as per the direction of Engineer-In-Charge. Note: Supply only for parts against unserviceable parts shall be measured and paid for separately under relavent items given below
Supply only safety valve ISI marked as per existing shape and size complete all as directed.
Supply only pressure realizing valve of size 15 mm dia as per existing shape and size complete all as directed.
Supply only inlet & outlet assembly plate suitable for 25 ltrs capacity geyser as per existing pattern complete all as directed.
Supply only gunmetal non returen valve/stop valve 15 mm dia from geyser connection pipe complete all as directed.
Supply only gun metal non return valve 15 mm dia including making proper connection complete all as directed.
Supply only 15 Amp plug top. Make : Anchor, Havells, colors.
Supply only heating element of 1.5 KW capacity same as existing make and model in geyser including taking down old heating element complete all as directed.
All as per Sl. item No.8 above but heating element of 2 KW capacity.
Supply only thermostat of temperature range 0-90°C, capacity 1.5 KW, 230 V of same type as per existing, suitable for geyser of capacity 25 to 50 ltr including taking down old thermostat complete all as directed.
All as per Sl. item No. 10 above but thermostat of 2 KW capacity.
S&F of fastening nut bolts including clamps for fixing of geysers of existing makes and models.
Supply only chromium plated connection pipe 15 mm size with brass nuts, of length 450 mm for geysers complete all as specified and directed. Make:- Jaquar (Essco) / Hindware (Less Italian Collection ) / Cera (Med Range) / Prayag (7000 & 8000 Series)
M&L for 15mm dia GI pipe medium grade complete with all fittings and fix on wall surface for geysers connection with necessary clamps and nut bolts / screws complete all as specified and as directed.
Taking down of solar water heater of any capacity and servicing of the same by authorized service provider as directed by the Eng-in-Charge, complete with checking of all water connection, tank, panel, cleaning of panel glass, gaskets, reservior tank, checking for lekages, mounting foundations etc. and making serviceable and testing after servicing and refixing the same in places as directed complete all as specified and as directd by the Eng-in-Charge. Note: - All minor parts and gaskets and repair of lekages of tank is included in the item rate.
S&F thermal insulation for solar water heater pipe after removing damaged insulations and cleaning complete all as specified and as directed.
Cleaning of solar water heating panel by opening inlet and outlet with necessary cleaning agent suitable for panel safety and re-connection complete all as specified and as directed.
Checking of connection of solar water heater to each individual supply point where hot water has been initially connected making output points serviceable with necessary cleaning of pipes complete all as specified and as directed.
M & L for sub main wiring with 2 runs of 2.5 Sqmm main wire alongwith 1 run of 2.5 Sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade copper conductor cable, drawn through and including adequate size PVC casing caping (double lock pattern) with all fittings & accessories on walls / ceiling surfaces etc., including taking down complete all as specified and directed. NOTE :- Two runs of main copper conductor, one run of earth wire and one run of PVC casing caping shall be measured as one unit length. Make of cable :- Havells / KEI / Polycab / RR Kabel Ltd. / HPL Make of PVC casing caping:- Richa Cables / AKG Industries / Harsh Electro Systems
M & L for sub main wiring with 2 runs of 4 Sqmm main wire alongwith 1 run of 4 Sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade copper conductor cable, drawn through and including adequate size PVC casing caping (double lock pattern) with all fittings & accessories on walls / ceiling surfaces etc., including taking down complete all as specified and directed. NOTE :- Two runs of main copper conductor, one run of earth wire and one run of PVC casing caping shall be measured as one unit length. Make of cable :- Havells / KEI / Polycab / RR Kabel Ltd. / HPL Make of PVC casing caping:- Richa Cables / AKG Industries / Harsh Electro Systems
S&F switch socket combination 2 in 1, 6 Pin, 5 & 15 Amp, flush type universal complete all as specified and directed. Make :- Havells / Anchor / Legrand
S&F in repairs 20 mm bore gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed. Make:- Kirloskar / Leader / Zoloto / Venus / Audco / Upadhyaya
Dismantling old defective solar water heater collector and supply and fixing in repair soloar water heater collector with aluminium frame, copper pipe, suitable size of glass, inlet and outlet of water etc as per existing complete all as specified and directed.
Dismantling and taking out old PVC water tank any capacity and supply and fix PVC water tank of 500 ltrs capacity triple layered with inlet & outlet water connection complete all as directed. Make: ISI marked.
Taking out old rusted stand of cold/hot storage water tank of solar water heater made with suitable size of angle iron including necessary welding including PCC work as required etc all as directed.
Dismantling of hot water storage tank of any make & size and supply and fix hot water storage SS tank of solar water heater of capacity 200 ltrs with proper insulation, inlet outlet water connection complete all as directed.
Taking out of solar water heater collector glass and supply and fix in repair solar water heater collector glass of existing size complete, ISI marked.
Taking out of rusted hot water insulated pipe and supply and fix GI pipe medium grade with insulation of size 20 mm dia complete all as directed.
Excavation in trenches for pipes, n exc 1.5m wide and n. exc 1.5m in depth and getting out in soft/ loose soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed.
Taking up/down 15mm bore steel tubing GI/CI/PPR pipeline and connections from trenches/floor/wall, cleaning and setting aside serviceable GI pipe for re-use & removing unserviceable pipe from site complete all as specified & as directed.
All as per srl item No. 32 above here-in-before but 20 mm bore.
All as per srl item No. 32 above here-in-before but 25 mm bore.
S&F GI tubing of medium grade 20mm bore and laid in trenches including all type fittings (socket,bend,Tee,Lbow,union etc) complete all as specified and directed
All as per srl item No. 36 above here-in-before but 25 mm bore steel tubing (GI).
M/s TALCO
M/S B B CONSTRUCTION
S D CONSTRUCTION CO
SHRI N.DAS
KARMIBRINDA
MS ESSCON
DEBABROTA ROY CHOWDHURY
D K SARKAR
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .