Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹8.5 L+₹48,835 (6.10%)Rejected-Finance 77 KAILASH PURI BIKANER RAJASTHAN PIN 334001 | BIKANER | RAJASTHAN | 334001 | L2 | Rejected-Finance Not Lowest | |
| 3 | l3₹10.5 L+₹2.5 L (30.7%)Rejected-Finance | l3 | Rejected-Finance Not Lowest |
Tender Value
₹7.5 L
EMD Value
₹15,000
Closing Date
12 Jun 2023, 6:00 pmClosed
CWE JAIPUR
Military Engineer Services, HQ Commander Works Engineer, Kalyan Marg, Banipark, Jaipur-06
PROVN OF GARRAGE WITH SHUTTER FOR AFT BOWSER AT HELIPAD UNDER ZONE -II AREA AT JAIPUR MIL STN
2023_MES_596108_1
CWE/JPR/82201/E8
Open Tender
Civil Works
Item Rate
120 days
JAIPUR
As per NIT
7 documents required · 7 mandatory
₹500
GE JAIPUR
₹15,000
Yes
7 Jul 2023
17 May 2023
14 Jun 2023
17 May 2023
12 Jun 2023
29 May 2023
17 May 2023 - 28 May 2023
Amount
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
M&L for excavating in trenchs, not exc. 1.5m wide and not exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil etc complete all as specified and directed.
Returning, filling including spreading leveling watering and well ramming in layers n. exc 25 cm in soft/loose soil etc complete all as specified and directed.
Removing excavated soil to a distance n. exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point etc complete all as specified and directed.
M&L for PCC 1:4:8 (Type D2) using 40 mm graded stone aggregate as in foundation filling and mass concrete etc complete all as specified and directed.
M&L for TMT bars10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with theincluding mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality etc complete all as specified and directed.
Ditto all as per Item no-6 above but 8 mm dia and over upto and including 10 mm dia etc complete all as specified and directed.
M&L for Use and waste of formwork to rough finished flat surfaces of concrete foundations, footings , bases of coulmns, rafts and raft beams, sides and soffits (if any) of foundation and plinth beams ; and other similar works; vertica or to batter etc complete all as specified and directed.
M&L for Use and waste of formwork to rough finished concrete surfaces of sides of square, rectangular or polygonal pillars posts, struts, piers, coulmns and stanchions etc complete all as specified and directed.
M&L for Use and waste of Formwork to rough finish surfesh soffits of suspended slabs such as roof slabs, floor slabs, chajjas, landings and similar work; not exceeding 200m thick (Horizontal or sloping) etc complete all as specified and directed.
M&L for cement concrete design mix M-25 (20 mm graded aggregateSlabs supported on walls, chajjas, roofs, landings, balconies, canopies, deck slabs and in the shelves and the like etc complete all as specified and directed.
M&L for cement concrete design mix M-25 (20 mm graded aggregate) as in /lintel/ roof beams, cantileveres, bressummers, lintels over 1.50 mtr span and all other similar works etc complete all as specified and directed.
Ditto all as per Item No 12 above but in coulmns, pillars piers, oosts and struts etc complete all as specified and directed.
M&L for cement concrete design mix M-25 (20 mm graded aggregate) foundatios, including rafts, footings, foundation, plinth beams, bases for coulmns etc and all other similar works complete all as specified and directed.
M&L for Brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 etc complete all as specified and directed.
M & L for 10 mm thick cement plaster in CM (1:6) on brick work/ RCC wall and finish the surface fair and even without using extra cement complete all as specified and directed.
Rendering 5 mm thick on ceiling in CM(1:3) finished even and smooth without using extra cement
Material and labour rendering 15mm thick cement plaster in CM 1:4 on other than fair faces of brick/concrete work surfaces in two layer 10mm each layer and top layer mixed with integral water proofing compound all as per manufacturer's instruction including all necessary scafolding arrangments of any hieght and as specified. Note : (i) WPC shall be measured and paid for separately as 'Supply only'. (ii) WPC to be mixed @200ml per 50 Kg bag of cement all as manufacturers instruction.
Supply only liquid water proofing compound.
M & L for 20 mm thick cement plaster in CM (1:3) mixed with water proofing compound as per manufacturing instruction on RCC slab while the concrete in still green and finish the surface fair and even without using extra cement complete all as specified and directed. Note : (i) WPC shall be measured and paid for separately as 'Supply only'. (ii) WPC to be mixed @3% by wt of cement or as manufacturers instruction.
M&L for preparation of new surfaces and applying three coats of white wash over a coat of primer including rubbing with siutable sand paper etc complete all as specified and directed.
M&L for preparing new plastered surfaces of walls and applying two coat of cement based paint etc complete all as specified and directed.
M&L for preparing new plastered ceiling surfaces and applying three coat of white wash complete all as specified
M& L for hardcore of broken bricks of gauge not exceeding 63mm, deposited, spread and leveled in layes not exc 15cm thick, watered and rammed to a true surface etc complete all as specified and directed.
M& L for PCC 1:4:8 type D2 40 mm graded aggregate, 100 mm thick as in sub base etc complete all as specified and directed.
M&L for 75 mm thick cement concrete (1:2:4) type B-2 (using 40mm size graded stone aggregates) floor, finish the surfaces even and smooth using extra cement including necessary form work all as specified and directed.
M& L for PCC 1:3:6 type C2 40 mm graded aggregate, 75 mm thick as in plinth protection etc complete all as specified and directed.
M&L Machine pressed precast concrete interlocking paver block,coloured rubber moulded any shape and size 60mm thickness, M-35 Grade with grey cement and pigment laid over and including 25mm thick sand layer etc complete all as specified and directed.
M&L Pre-cast cement concrete (1:2:4) block masonry with solid bloacks, exc.10 cm in width and setting in mortar, etc complete all as specified and directed.
S&F in repair 1.00 mm laths thickness steel rolling shutters, without ball bearing,as specified including top cover,anchoring rod ,hasp and staple and one shop coat of primer,erected in position as indicated complete : gear operated type with bevel gear box and crank handle Safety lever locks mild steel with 4 levers for rolling shutters etc complete all as specified and directed.
M&L for preparation of applying two coats of synthetic enamel paint over a coat of pink primer of any description not otherwise described over 10 cm girth or width complete all as specified and directed.
M&L for Point wiring complete as specified with 1100 volt grade 1.5sqmm (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including rigid non-metallic PVC concealed conduit of suitable size but not less than 20mm dia, with all fittings, concealed in wall/roof /floor including unwelded sunken galvanized pressed steel terminal boxes of thickness not less than 1.0 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulators as required for the following :- One light/fan/ Exhaust fan point controlled by one switch 6 Amps 1 way.
All as per item No. 32 above but point wiring with 4 sqmm PVC insulated multistranded copper conductor suitable for one light point controlled by one switch.
S & F industrial plug & socket combination for light point, 2 pole and 1 earth, one way etc complete all as specified & directed.
S & F industrial flame proof socket with switch, 2 pole and 1 earth, 16 Amp one way etc complete all as specified & directed.
S&F in repair MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43, IK-09 with reversible double door, recess mounted , having insulated 100 Amps tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with SPN, 240 volts, 4 ways etc complete all as specified and directed
S&F MCBs of 'C' series single pole 6 to 32 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete.
S&F MCBs of 'C' series single pole 40 to 63 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs etc complete all as specified and directed
S&F flameproof LED lights fittings, 26 watt, 220 volts AC, decorative type with driver, holder including connecting up with three core flexible multi stranded copper conductor cable of suitable size of ceiling rose etc complete all as specified and directed. Make : Havels ENDURA WELL GLASS NEO TS 26 WLED 757 SPECS or equivalent as approved by GE
S & F Exhaust fan 300mm sweep 1440 RPM ,Heavy Duty Exhaust Fans metal body type with ISI working on single phase, 230volt, 50Hz AC supply complete with Lovers and fixing acessories complete with insulated 3 core copper cable of size 0.75 sq.mm complete as as directed.
S&F 1100 volt grade heavy duty XLPE cable with PVC insulated aluminum conductor served with inner sheathing of PVC tape and overall PVC sheathed of size 6 Sqmm nominal cross section 2 core, fixed to pole or suspended including all necessary clamps, 4mm GI suspension wire along cable, nuts, bolts washers etc complete all as specified and directed.
ABHOG INFRASTRUCTURE PRIVATE LIMITED
SUMEET TRADING COMPANY
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .