| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC | ₹1.4 Cr | L1 | Accepted-AOC Lowest Bid L1 rank is competitive and reasonable during Scrutiny amongst bidders |
| 2 | L2₹1.6 Cr+₹10.5 L (7.26%)Rejected-AOC | ₹1.6 Cr+₹10.5 L (7.26%) | L2 | Rejected-AOC Being Not lowest |
| 3 | L3₹1.6 Cr+₹15.0 L (10.4%)Rejected-AOC E 30 RAJIV NAGAR BEGUMPUR NEW DELHI 110086 | NEW DELHI | NEW DELHI | DELHI | 110086 | ₹1.6 Cr+₹15.0 L (10.4%) | L3 | Rejected-AOC Being Not lowest |
Tender Value
₹1.6 Cr
EMD Value
₹2.4 L
Closing Date
7 Mar 2024, 6:00 pmClosed
CWE (AF) BAMRAULI
HQ CWE(AF) BAMRAULI, PRAYAGRAJ-211012
PROVISION OF OTM ACCN FOR LOGISTIC SECTION AT AF STN GORAKHPUR
2024_MES_635250_2
87319/E8
Open Tender
Civil Works
Lump-sum
365 days
GORAKHPUR
AS PER NIT
8 documents required · 8 mandatory
₹1,000
GE (AF) GORAKHPUR
₹2.4 L
Yes
22 Nov 2024
14 Feb 2024
9 Mar 2024
14 Feb 2024
7 Mar 2024
22 Feb 2024
14 Feb 2024 - 21 Feb 2024
Amount
Lump sum price worked out by the contractor as per showm on drawing for BUILDING WORKS as listed in Sch ‘A’ Part-I.
Lump sum price worked out by the contractor for HARDSTANDING AND PARKING SHED as listed in Sch 'A' Part-II.
Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Sch 'A' Part-III.
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION as listed in Sch 'A' Part-IV.
Lump sum price worked out by the contractor for LIGHTENING PROTECTION as listed in Sch 'A' Part-V.
Lump sum price worked out by the contractor for SEWAGE DISPOSAL as listed in Sch 'A' Part-VI.
Lump sum price worked out by the contractor for ROAD / PATH / CULVERT as listed in Sch 'A' Part-VII.
Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Sch 'A' Part-VIII.
Lump sum price worked out by the contractor for EXTERNAL ELECTRIC SUPPLY as listed in Sch 'A' Part-IX.
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY as listed in Sch 'A' Part-X.
Lump sum price worked out by the contractor for EARTH WORK as listed in Sch 'A' Part-XI.
Price item wise worked out by the Contractor for Schedule `A' Part-XII (rate against Srl No. 13.0 to 23.0 shall be quoted by the Contractor)
S&F white modular cover plate with frame 12 module, for modular switches and sockets complete all as specified and directed.
S&F metal flush box 12 module, made of 1.6mm thick sheet, for mounting modular switches and sockets complete all as specified and directed.
S&F metal flush box 8 module, made of 1.6mm thick sheet, for mounting modular switches and sockets complete all as specified and directed.
S&F wall mounted fan voltage 230V, 50 Hz, RPM 1200, copper winding of sweep 300mm complete all as specified and directed
M&L for cutting GI tubing of size 25mm bore dia in position for insertion of new tees, branches, etc. complete all as specified and directed.
Supply, install and testing split type air conditioner inverter technology of capacity 2 Ton, 5 star rating for working on 230 volt, single phase, 50 Hz supply complete including cutting of existing wall and proper fixing making good disturbed surface and providing water pipe upto ground level complete all as specified and directed.
S&F automatic voltage stabilizer for low and high voltage correction equipped with electronic transistorised relay suitable for operation single phase, AC, 50 Hz complete with voltmeter, indicators and designed for input voltage 130 to 300 stabilised between 215 V to 220 V of capacity 5KVA (not less than 17 Amp) complete all as specified and directed.
S&F modular type PVC enclosure with a two pin and earth plug and socket 16 Amps complete with one single pole MCB 20/25 Amp capacity complete all as specified and directed.
M&L for Sheet Metal Enlcosure for mounting 4 pole MCCB 12 to 63 Amps complete all as specified & directed.
M&L for PCC of M-25 grade using 20 mm graded stone aggregate finished with rolling and spiked rolled to surfaces making impression of expanded metal complete all as specified & directed.
M&L for copper electrode chemical earthing as per IS-3043:2018 with high conductive, corrosion resistant, CPRI tested and CE certified, maintenace free chemical earthing pit (Strip in pipe technology based) in which copper bonded elctrode having size 88mm dia and 3 mtr long with terminal of size 50x6mm. The length of this elctrode minimum 3000 mm (3 meters). Marconite conductive aggregate is mixed with cement normally in the ratio of 2:1 (2 parts marconite : 1 part cement) and add one litre of water per Kg of total mix to form a fairly dry mix (Corrosion free green product in bag of 25 Kg each, marconite back fill compound per pit per unit to be filled) and used as backfill to enhance the effect of earth electrode in earth pit of bore hole 200 to 250 mm dia and depth upto 6.15 meters minimum, length of elctroded will be increase with connecting of 32mm x 6mm copper strip extra upto 3.5 meters and total depth of earthing electrodes is 6.15 meters (minimum) for achieve resistance value less than of equal to 1.0 Ohm including RCC earthing pit cover having 450 x 450 mm complete all as specified and directed. Note: - (a) If less than 1.0 Ohm result has not achieved at site, no payment shall be claimed by the contractor to this effect. (b) Earth continuity conductor of length upto 7.50 meter from electrode shall deemed to be included in the quoted rate.
M/s Comfort Air Conditioning and Refrigeration Engineers
GIAN ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .