Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹35.7 L+₹1.3 L (3.77%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹38.5 L
EMD Value
₹77,000
Closing Date
20 Aug 2022, 6:00 pmClosed
Shri Kislay Kishore, IDSE
GE (AFA) Hyderabad PIN-500043
PROVISION OF DEFICIENT TECHNICAL AND AFNET INFRASTRUCTURE AT AFA HYDERABAD.
2022_MES_539410_1
8253/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AFA) Hyderabad
As per tender pages
4 documents required · 4 mandatory
₹500
GE(AFA) Hyderabad
₹77,000
Yes
1 Nov 2022
20 Jul 2022
22 Aug 2022
20 Jul 2022
20 Aug 2022
5 Aug 2022
20 Jul 2022 - 4 Aug 2022
Amount
M&L for Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in Hard/Dense Soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated soil to a distence n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M& L for Plain Cement concrete (1:4:8)Type D2 using 40 mm graded Stone Aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
M& L for Plain Cement concrete (1:3:6)Type C2 using 40 mm graded Stone Aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for RCC M-25 in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for RCC M-25 in Columns, pillars, piers, posts and struts complete all as specified and as directed.
M&L for RCC M-25 in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L for RCC M-25 in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M&L for RCCM-25 as in Chajjas complete all as specified and as directed.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter surfaces, fair finished complete all as specified and as directed.
M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions, fair finished complete all as specified and as directed.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc, fair finished complete all as specified and as directed.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), fair finished complete all as specified and as directed.
Formwork to chullah hoods, chajjas, troughs and similar items including edges for rough finished surfaces of concrete flat, fair finished ,Complete all as specified and directed.
M& L for Pre-cast cement concrete (1:3:6) type C1( using 20 mm graded stone aggregate ) block masonry with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, complete all as specified and as directed.
M& L for Pre-cast cement concrete (1:3:6) type C1( using 20 mm graded stone aggregate ) block masonry with solid blocks, in half brick thick walls n.exc. 10 cm in width and setting in cement mortar 1:4, complete all as specified and as directed.
S & F of Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde- E-165,complete all as specified and as directed.
S & F of Mild steel TMT bars 10mm dia and over cut to length bent to shape required including crancking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia all as specified and directed.
S & F of Mild steel TMT bars 6mm to 8mm dia cut to length bent to shape required including crancking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia all as specified and directed
M & L TMT bars 5 mm dia upto 10 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia in stirrups, spacers and binders all as specified and directed.
M & L for Rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:6, surface finished even & smooth without using extra cement complete all as specifiedand directed
M & L for Rendering 5 mm thick on ceiling surfaces of concrete in CM 1:3 finished even & smooth without using extra cement complete all as specified and directed
M & L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 mixed with WPC as per manufacturers instructions finished even & smooth without using extra cement complete all as specified.and directed Note: WPC shall be measured and paid separately.
M & L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even & smooth without using extra cement complete all as specified.and directed
M & L for Rendering 10 mm thick on fair faces of concrete surfaces of roof in CM 1:3 finished even & smooth without using extra cement mixed with using WPC complete all as specified.and directed Note:WPC shall be measured and paid separately
Supply only liquid waterproofing compound of approved makes.
M & L preparation of new plastered surfaces of wall and applying two coats of Oil emulsion distemper over a coat of primer complete all as specified and as directed.
M & L preparation of new plastered surfaces of ceiling and applying two coats of Oil emulsion distemper over a coat of primer complete all as specified and as directed.
Preparing newly plastered surfaces of walls and applying two coats of cement based paint over a coat of primer complete all as specified and as directed.
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for Anti termite treatment, treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface all as specified and directed. Note:(Area of the sub structure in contact with backfill to be measured)
M&L for Anti termite treatment, treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface all as specified and directed.
M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area all as specified and directed.
M&L for Anti termite treatment, treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall all as specified and directed.
M& L for 100 mm thick Plain Cement concrete (1:4:8)Type D2 (using 40 mm graded Stone Aggregate) as in sub base flooring complete all as specified and as directed.
M&L 25 mm thick plain Cement concrete (1:2:4) type B-0,(using 12.50 mm graded stone aggregate) as in sub bse/ floor finish concrete complete all as specified and as directed.
M & L for coloured Non-skid ceramic tiles matt finish (square/rectangular) 7 to 8mm thick in floors, area of each tile exc.0.11 sqm but n.exc 0.18 sqm, set and jointed in neat cement slurry and pointed in white cement mixed with matching pigment over and including 20 mm thick screed bed in CM 1:6 all as specified and directed.
M & L for glazed coloured ceramic tiles of size 300 x 450mm, digital type in dados/skirting etc set and jointed in neat cement slurry and pointed with white cement mixed with pigment, laid over and including rendering / backing coat 10mm thick in cement mortar 1:4 complete all as specified and directed.
S&F Anodised aluminium Powder Coated (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed
S&F Anodised aluminium powder coated of any colour (Thickness or powder coating not less than 50 micron) door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc. complete all as specified and directed.
S&F Anodised aluminium powder coated of any colour (Thickness or powder coating not less than 50 micron) window and ventilator shutters, sliding type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as locking latches , rollers suitable handle etc complete all as specified and directed.
S&F Sheet glass 5.5 mm thick tinted, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane.all as specified and directed.
S&F Sheet glass 4 mm thick tinted ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane all as specified and directed.
S & F Prelaminated particle board 12 mm thick exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with screws to timber/ Aluminium frame work all as specified and directed
M& L for 75 mm thick Plain Cement concrete (1:3:6) Type C1 (using 20 mm graded stone Aggregate) as in plinth protection laid in alternate bays not exceeding 2 Sqm each and finished fair on top without using extra cement. 6mm wide joints shall be provided throughout the thickness of plinth protection in concrete bays. All joints in bays of concrete, shall be filled with mastic filling comprising of one part of heated bitumen Vg-30 grade and 3 parts of sand (all by weight). all as specified and directed.
M&L for Plain cement concrete 1:2:4 type B1( using 20 mm graded stone aggregate) as in lintels up to 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses,Kerbs string courses, copings, and the like including necessary form work, weathering, slightly rounded or chamfered angles and throating,all as specified and directed
M & L preparation of new plastered surfaces of walls and applying three coats of white wash all as specified and as directed.
M & L preparation of new plastered surfaces of ceiling and applying three coats of white wash all as specified and as directed.
M&L 40 mm thick plain Cement concrete (1:2:4) type B-1( using 20mm graded stone aggregate) as in flooring, surface finished even and smooth without using extra cement all as specified and as directed.
S&F Glass dividing strips, 3 mm thick and 38 mm wide inserted in position,conform to design all as specified and as directed.
S & F Rolled Mild steel as in framed work Fe- 290 (Gde E-165) as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed.
M&L for 1.00 mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, welded to frames all as specified and directed.
M&L for Preparation of new Steel and Iron Surfaces of any description, over 10cm in width or girth,not otherwise described and painting with two coats of Synthetic enamel paint over a coat of red oxide primer all as specified and directed.
M&L for rendering 10mm thick in cement mortar 1:4 on fair faces of brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M & L Morrum/red bajri filling in floors or pavings, laid in layers n exc. 15cm thick, spread, levelled and rammed including watering all as specified and directed.
Demolition of Brickwork or stone/boulder masonary,built in cement mortar including all quoins,arches,pillars,etc,but excluding ashlar facings, dressed stonework and precast concrete articles and removing unserviceable debriis off the premises complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar and removing rubbish off the premiisescomplete all as specified and directed
Taking down chowkats or frames with shutters n exc 1.50 sqm (without taking off shutters from the frame) complete all as directed.
Taking down chowkats or frames with shutters exc 1.5 sqm but n exc 4 sqm (without taking off shutters from the frame) complete all as directed.
Dismantling of asbestos cement (corrugated, semi corrugate etc) sheet in roof covering all as specified and directed
Dismantling of wrought iron or mild steel work of any description not otherwise provided for all as specified and directed.
M&L for 100mm thick PCC 1:3:6 type C2 using 40mm graded aggregate as in floor / hard standing, surface finished even and smooth without using extra cement all as specified and as directed.
M&L for preperation of new concrete /plastered surface of any description,applying 3mm thick thick (average) wall care putty and two coats of distemper oil emulsion over a coat of primer complete all as specified and as directed
M & L for Making good under cills or over arches, lintels and bressummer incl under pinning when necessary in CM (1:4) all as specified and directed.
S & F Aluminium door frame with shutter using powder coated aluminium section 100 x 44 x 2 mm thick for frame / chowkats fixed in existing opening including necessary joining cleats, suitable hold fasts screws etc and fully/partly glazed shutters made with powder coated aluminium section fixed with 100 mm Aluminium butt hinges, section for left and right stiles 84 x 44 x 2 mm, for top rails 84 x 44 x 2 mm, middle and bottom rails 100 x 44 x 2mm shutter including 5 mm thick tinted/frosted glass panels and 12mm thick particle board for bottom portion inserts with necessary joining cleats, glazing clips rubber packing, aluminium snap beading screws etc fixed and making good to surface of wall and floor to match with the existing surface including 200mm Aluminium handles on both side and inner side 200mm length tower bolt, for locking device brass mortise locks 4 lever 100 mm size vertical type, rubber gaskets etc, all sections as per manufacture's instructions, frames firmly secured to jambs/Soffits with all necessary fittings and fixtures including door clouser hydraulically regulated, aluminium body designation No 2 universal type (ISI marked), suitable for shutters of weight between 36 to 60 Kg all as specified and directed by Engr-in-Charge. (Thickness of powder coating not less than 50 micron).
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in soft/loose soil all as specified and as directed.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface in hard/dense soil complete all as specified and directed by Engr-in-Charge.
M&L for Plain cement concrete 1:2:4, type B2 using (40mm graded stone aggregate) as in foundation, filling and mass concrete etc., complete all as specified and directed.
M&L for 75 mm thick PCC 1:4:8 type D-2 using (40 mm graded stone aggregate) in sub base complete all as specified and as directed
M&L for 75 mm thick PCC 1:2:4 type B-2 using (40 mm graded stone aggregate )in floors, finishing surface even and smooth with out using extra cement complete all as specified and as directed
S&Fof Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240.all as specified and as directed.
S & F for mild steel (framed), purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc all as specified and directed
M&L for MS plates Fe 410 Gd E250 in trusses (framed), etc connecting with bolts/welding as base plates/connecting plates etc complete all as specified and as directed.
S&F Pre painted galvalume aluminium zinc coating GI based corrugated sheet 0.5mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall with self tapping screws complete all as specified and as directed.
Removing excavated soil to a distance exc. 250m and not exceeding 500m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.
M&L for MS bolts and nuts made with hexagonal or square headed one end and screwed the other and to be fitted with washer and one nut n exc 30 cm long complete all as specified and as directed
Providing and fixing in true horizontal level false ceiling grid system manufactured by M/S ARMSTRONG WORLD INDUSTRIES US/UK or equvalent using hot dipped galvanised steel section exposed surface chemically cleaned capping, prefinished in baked polyester paint, main Tee of size 3000x32x15mm at every 1200 c/c, max and 1200mm cross Tee of size 1200x32x15mm at every 600mm c/c max and 600mm cross Tee of size 600x32x15mm at every 1200 mm c/c max and 3000x19x19mm wall angle all around the wall to form grid size of 600x600mm and suspending the grid using 2mm pro-straightened GI wire and 6mm nylon rawl plug at every 1200mm intervals at the main tee and laying ARMSTRONG ULTIMA MICRO LOOK manufactured by armstrong world industries or equivalent all as specified and as directed.
M&L for cutting holes in brick walls exceeding one bricks but not execeeding two bricks for inserting holdfast and making good dismantled portion in Cement mortar 1:3 or Cement concrete 1:2:4 etc complete all as specified and as directed.
S&F Mild steel plates, plain or chequered,5mm thick or over in thickness in available size as in duct cover of FE 290 Gde E-165 complete all as specified and as described.
M & L for chequered cement concrete coloured tiles glossy finish of size 300mm x 300mmx 25mm thick, set, jointed and pointed in neat cement slurry in floors/paths with pigments matching to adjacent etc laid over and including screed bed in CM (1:6), 20mm thick complete all as directed and specified.
M & L for Forming fair finished drain using extra cement of width n.exc 30cm all as specified and directed by Engr-in- Charge
M&L for Point wiring complete with 1.5 sqmm single core FRLS grade 1100 V PVC insulated unsheathed wire with multi stranded copper conductor drawn through and including stove enamelled steel conduit and conduit accessories ISI marked fixed on wall / ceiling/ roof etc and including provision of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS ISI marked as earth continuity conductor etc, complete all as specified and directed. Note : The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
(a) One light point controlled by one switch
(b) One exhuast fan/Wall mounted Fan controlled by one switch
All as per item No. 84 above but wiring with 2.5 sqmm copper cable with 2.5 sqmm for earth continuity cable for 6 pin 15 Amp sockets outlet controlled by 15 Amp switch
S&F of Flame proof switch socket &plug combined in LM6 cable termination box in LM6 16A 250 V 2 P+ earth complete all as specified
S & Fof Switch flame proof rotary type with termination box in LM6, 16A, single pole 250 V complete all as directed
S&F of ceiling rose, three terminal, PVC/polycarbonate, insulated body, ISI marked complete all as specified and as directed.
S & F DB with sheet metal enclosure 240 volts, 4 way Single phase double door with copper bus bar neutral link, earth link, earthing studs, without MCBs complete all as directed. Note : Distribution Board shall be fitted out side of store .
S & F MCB SPN of 240 Volts, AC, 50 Hz of capacity 6-32 Amp 10 KA complete all as specified and directed.
S & F MCB 'C' series SP 6-32 Amps rating, 10 KA breaking capacity, 240V, 50Hz, AC supply,complete all as specified and directed.
S&F of flame proof LED tube light fitting 1x16 to 20W , 230 V including integral reflector made of aluminium alloy LM 6, with all connected accessories and all accessories pre-wired, connecting up with FRLS flexible copper conductor with suitable size all as specified and directed.
S & F exhaust fan flame proof, AC single phase, 230/240 V of size 380 (15'') mm sweep with louvers 1440 RPM including making necessary opening on stone /brick masonry wall and making good with matching colour with the surroundings all as directed.
S & F Wall mounted fan flame proof, AC single phase, 230/240 V of size 450mm (18'') sweep with 1500 RPM IP 66 all as specified and directed
M&L for Earthing complete with GI earth plate electrode of size 600x600x6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to 25x4 mm GI iron strip earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:2:4) type B-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed after taking down old earthing.
Note: (i) Cost of GI strip and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item.
(ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returning filling , removing , PCC chamber pit, RCC cover, test point etc.
S&F of Air Termination, Single pointed, Aluminium rod 12 mm dia and 300 mm long all as specified and directed .
S & F of Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground and the other end connected to test point complete all as specified and directed.
S & F of Test Point Terminal Block made of gun metal or Phosphorus bronze size 75 mm x 75mm x25 mm, drilled and screwed and including 3 Nos 8 mm dia 25 mm long hex head screws all as specified and directed.
S & F of DMC / FRP insulators, of suitable size to seperate the earth strips from the walls, duly screwed on the walls and makingholes in the earth strips by drilling and fixing the earth strip rigidly with the insulators with GI bolts, nuts, washers etc complete all as specifed and directed.
M&L point wiring complete with 1.5 sqmm single core FRLS grade 1100 V PVC insulated unsheathed wire with ulti stranded copper conductor drawn through in and including PVC cassing capping and accessores ISI marked fixed surface on wall/ ceiling /roof etc and includimh provision of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS ISI marked as earth continuity conductor etc including 1.2mm thick pressed steel terminal switch boxes, 3mm thick bakelite sheet top cover fitted with chromium plated brass screws and washers complete all as specified and directed for :-
(a) One light point controlled by one switch
(b) One ceiling / Exhaust fan point controlled by one switch
(c) One three pin socket 5 Amps point on same board
(d) One three pin socket 5 Amps point independent board
S&F Switch piano flush type single pole one way, 5 A, complete all as specified and directed
S&F switch socket combination 2 in 1, 5 Amp Flush Type 5 pin multipurpose suitable for independent board complete all as specified and directed
S&F switch socket outlet 3/5 pin , 5 Amp Flush ISI marked complete all as specified and directed
S&Ffor electronic step type fan regulator complete all as directed by Engr-in-Charge.
S&F surface mounting / wall mounted LED tube light fitting 1x20/18watts high efficiency, anti glare, maintenance free operation including LED driver and mounting arrangements, all accessories internally pre-wired, connecting up with twin core twisted flexible copper conductor cable white colour with suitable size complete all as specified and directed by Engineer-in-Charge.
S & F 1X36 to 40W high efficiency 2'X2' recess mounting LED light fitting with glare free homogeneous illumination including LED driver with all accessories internally pre-wired, connecting up with three core twisted flexible copper conductor cable complete all as specified and directed by Engineer-in-Charge.
M&L for Sub Main wiring with two runs of 6sq mm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through medium grade, rigid non-metallic PVC conduit / casing & caping (as per site requirement) of suitable size with all necessary fittings, surface in walls/roof/floor duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly complete all as specified and directed by Engineer-in-Charge.
Note:-(i) Necessary PVC dummy plates & PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate. (ii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads. (iii) Three runs of cable and one run of PVC conduit / casing caping will be measured as one uint.
S & F DB with sheet metal enclosure 240 volts, 4 way Single phase double door with copper bus bar neutral link, earth link, earthing studs, without MCBs complete. Distribution Board shall be fitted out side of the store complete all as directed.
S & F MCB SPN of 240 Volts, AC, 50 Hz of capacity 6-32 Amp 10 KA complete all as specified and directed.
S&F MCB 'C' series SP 6-32 Amps rating, 10 KA breaking capacity, 240V, 50Hz, AC supply,complete all as specified and directed.
S&F ceiling fan complete with electronic type regulator and accessories 230 V, 1200 mm sweep BEE 2 star rated and connecting up including provision of cable from ceiling rose or connector to fan and making necessary hanging arrangment of ceiling fan by providing U- type clamp with fasteners, bolt, washer including grouting complete all as specifed and directed by Engineer-in-Charge.
M&L for Earthing complete with GI earth plate electrode of size 600x600x6.6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI wire 4 mm dia earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanized iron pipe 15 mm bore (Medium grade) all as directed including cement concrete (1:2:4) type B-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed .( GI wire upto 7.5m including testing consider in this item).
M & L Sand covering /cushioning for underground cable protection 8cm deep before laying of cables and 15cm deep over the cables and punned down to 18cm thickness and consolidation complete all as specified and directed by Engr- in Charge. Note: Punned thickness shall be measured
M&L for burnt bricks sub class 'B' laid perpendicular over & cushioning for cable protection complete all as specified & directed at site by the Engr- in Charge.
Supply, lay , connecting and testing for XLPE insulated, armoured heavy duty electric cable with aluminum conductor ,1100 V grade,cross-sectional area 06 Sqmm and 2 core laid in trenches including aluminium lugs as required for connection complete all as specified and directed by Engr- in - Charge.
Supply & install UPS with triple level inverter and delta's innovative One phase AC input 160V to 260 volts and out put One phase 230 volts +/- 1% of capacity 6 KVA, power factor (> 0.99) & up to 96% AC-AC efficiency and sealed maintenance free Battery Bank for 60 min back up including the following etc complete as directed :- a) Battery Rack - 1 No. (b) Battery inter connecting links - 1 No. (c) Battery to UPS cable - 1 No (d) Battery Fuses - 1 No Battery Rating : 12 V / 26AH * 16 Nos Battery Brand : Amaron,Exide UPS Make: Luminious,Microtech,
Supply & install UPS with triple level inverter and delta's innovative three phase AC input 300 to 440 volts and out put One phase 230 volts +/- 1% of capacity 10 KVA, power factor (> 0.99) & up to 96% AC-AC efficiency and sealed maintenance free Battery Bank for 60 min back up including the following etc complete as directed :- a) Battery Rack - 1 No. (b) Battery inter connecting links - 1 No. (c) Battery to UPS cable - 1 No (d) Battery Fuses - 1 No Battery Rating : 12 V / 65AH * 16 Nos Battery Brand : Exide,Amaron UPS Make: Luminious,Microtech,
M & L for Submain wiring with Four runs of 10 sqmm single core PVC insulated unsheathed multistranded copper condutor cable drawn in and incl non metallic rigid PVC conduit and accessories fixed on surfaces of wall/ceiling/floors etc along with ONE run of 10 sqmm PVC insulated multistranded copper conductor cable as earth contunity conductor connected to common earth dolly complete all as specified and directed . Note:- Four runs of 10 sqmm PVC cable , 1 run of PVC CONDUIT with accessories and ONE RUN of 10 sqmm PVC cable will be measured as one length.
S & F Wall socket with DIN Rail made out of thermoplastic sheet having IP- IP 67 protection triple pole, neutral and earth socket with three pin, neutral and earth plug watertight complete with one TPN MCB 63 amps complete all as specified and as directed. Hensal cat N-AS 169 TS
S & F Wall socket with DIN Rail made out of thermoplastic sheet having IP- IP 67 protection 2 pole, and earth socket with three pin, neutral and earth plug watertight complete with one TPN MCB 32 amps complete all as specified and as directed. Hensal cat N-AS 169 TS
M&L in replacement earth continuity conductor fixed to wall on batten or recess or chessis or burried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc as reqd 4.00mm dia galvanised iron or steel wire all as specified and directed by Engr- in- Charge.
N Sreenivasarao
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .