Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹1.7 Cr
EMD Value
₹3.4 L
Closing Date
27 Nov 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TECHNICAL
16 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Note: In case, date of tender inviting is on or after date of statutory deadline for audit of balance sheet of previous FY (i.e. 30th Sept or as further extended for this FY), audited balance sheet of 4th previous year shall not be considered unless concerned CA certifies that balance sheet is not audited yet as on date of invitation of this tender.
The contractor should have valid Electrical Contractor License issued by Govt. and submit along with tender document. If valid Electrical Contractor License is not submitted along with tender document, then offer will be summarily rejected.
16 conditions · 3 needing a document upload
The tenderer shall submit all relevant documents as detailed in para 14 & 18.10 of Tender Form (Second Sheet) of Part I of GCC work-2022.
The tenderer shall submit copy regarding status of firm i.e. sole proprietorship, partnership, Company, Society/Trust etc. and also submit a power of attorney and other relevant documents as detailed in Para no. 15 of Tender Form (Second Sheet) of Part- I of attached GCC-2022.
The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society / Registered Trust / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. The tenderer(s) shall enclose the attested copies of the constitution of their concern and copy of PAN Card along with their tender. Tender Documents in such cases are to be signed by such persons as may be legally competent to sign them on behalf of the firm, company, association, trust or society, as the case may be. Following documents shall be submitted by the tenderer:
a) Sole Proprietorship Firm: (i) All documents in terms of Para 10 of the Tender Form (Second Sheet) of GCC-2022.
(b) HUF: (i) A copy of notarized affidavit on Stamp Paper declaring that he who is submitting the tender on behalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and he has the authority, power and consent given by other members to act on behalf of HUF. (ii) All other documents in terms of Para 10 of the Tender Form (Second Sheet) of GCC- 2022.
(c) Partnership Firm: (i) A notarized copy of the Partnership Deed or a copy of the Partnership deed registered with the Registrar. (ii) A notarized or registered copy of Power of Attorney in favour of the individual to tender for the work, sign the agreement etc. and create liability against the firm. (iii) An undertaking by all partners of the partnership firm that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm / LLP in which they were / are partners / members. Any Concealment / wrong information in regard to above shall make the bid ineligible or the contract shall be determined under Clause 62 of the Standard General Conditions of Contract. (iv) All other documents in terms of Para 10 of the Tender Form (Second Sheet) of GCC-2022.
(e) Company registered under Companies Act 2013: (i) The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (ii) A copy of Certificate of Incorporation (iii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv) All other documents in terms Para 10 of the Tender Form (Second Sheet) of GCC-2022.
(f) LLP (Limited Liability Partnership): (i) A copy of LLP Agreement (ii) A copy of Certificate of Incorporation (iii) A copy of Power of Attorney / Authorization issued by the LLP in favour of the individual to sign the tender on behalf of the LLP and create liability against the LLP. (iv) An undertaking by all partners of the LLP that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm / LLP or JV in which they were / are partners / members. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the Standard General Conditions of Contract. (v) All other documents in terms of Para 10 of the Tender Form (Second Sheet) of GCC-2022.
(g) Registered Society & Registered Trust: (i) A copy of Certificate of Registration (ii) A copy of Memorandum of Association of Society/Trust Deed (iii) A copy of Power of Attorney in favour of the individual to sign the tender documents and create liability against the Society/Trust. (iv) A copy of Rules & Regulations of the Society (v) All other documents in terms of Para 10 of the Tender Form (Second Sheet) of GCC-2022.
The tenderer whether sole proprietor / a company or a partnership firm / joint venture (JV) / registered society / registered trust / HUF / LLP etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he / they be partner(s) of the firm or any other person, specifically authorizing him / them to sign the tender, submit the tender and further to deal with the Tender / Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed / Memorandum of Understanding / Article of Association / Board resolution, failing which tender shall be summarily rejected. A separate power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he / they be partner(s) of the firm or any other person, shall be submitted after award of work, specifically authorizing him/them to deal with all other contractual activities subsequent to signing of agreement, if required. Note: A Power of Attorney executed and issued overseas, the document will also have to be legalized by the Indian Embassy and notarized in the jurisdiction where the Power of Attorney is being issued. However, the Power of Attorney provided by Bidders from countries that have signed the Hague Legislation Convention 1961 are not required to be legalized by the Indian Embassy if it carries a conforming Appostille certificate.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractor should quote only the above/below percentage on estimated value, in the space provided at web portal for the purpose & nowhere else. Financial & Technical conditions quoted at any place other than prescribed space shall not be entertained while evaluating the offer.
Tenderer are required to go through the documents attached along with the tender and submit their bids accordingly.
Electrical work in c/w Provision of Air Conditioners in DRM office Bikaner over Bikaner Div.
10-EL-BKN-E-Tender-26-27R~NWR
10-EL-BKN-E-Tender-26-27R
Open
Works - General
6 Months
Bikaner, Rajasthan
₹0
₹3.4 L
4 Nov 2026
4 Nov 2026
13 Nov 2026
105 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,70,81,297 | ||
| — | 250.00 | — | — | ||
| Transportation, Fixing and Commissioning of split AC 1.5 ton with all accessories as per site requirement and as per specification. ( AC will be supplied by Railway) | — | — | — | 5,91,000 | |
| — | 4.00 | — | — | ||
| Supply ,Erection ,Wiring, Testing and Commissioning of HT vacuum circuit breaker 11 kV , 630 to 800 Amp VCBs (the Supplied 04 VCB should be arranged in such a set of one incoming and three outgoing VCB,) copper bus bar system with standard fitting as per IS 13118/ 1991 or latest along with power pack as per specification (Inspection Clause : By RITES ) | — | — | — | 23,39,600 | |
| — | 1.00 | — | — | ||
| Design, supply, installation, testing and commissioning of 11/0.433KV Compact substation (CSS) of 630 kVA as per Specification. (Inspection Clause : By RITES) | — | — | — | 49,11,357 | |
| — | 1.00 | — | — | ||
| Design, supply, installation, testing and commissioning of LT Panel with incomer 800Amp. ACBs 1 no. and outgoing 400A MCCBs 4 nos., 250A MCCBs 4 nos and 100A MCCBs 3 nos as per specification. (Inspection Clause : By RITES) | — | — | — | 6,79,739 | |
| — | 250.00 | — | — | ||
| Supply of 11 kV grade, 3-core x 120 sq. mm, XLPE insulated, screened, armoured, PVC sheathed, aluminium conductor HT cable, suitable for 11 kV, 3-phase, 50 Hz system, conforming to IS 7098 (Part 2) of reputed make. (Inspection Clause : By Railway Representative) | — | — | — | 2,75,000 | |
| — | 250.00 | — | — | ||
| Laying, testing & commissioning of 11KV/33 KV XLPE cable in air/ ground / in trench/ spun/ HDPE pipe, with transportation from main depot to required site, and as per specification enclosed. Note: - The contractor will be responsible for collection of cables from the Elect Maintenance / Works Depot including loading, unloading, transportation and return of un-used cables back at Depot. Cost of these provisions is deemed to be included in the quoted rate for this item. | — | — | — | 40,750 | |
| — | 4.00 | — | — | ||
| Supply, fixing and commissioning HT 11 KV XLPE heat shrinkable HT Cable end box outdoor type Suitable for HT Cable Size 120-185 sq.mm.as per specification. Make- Raychem, 3M, Denson, Cabseal or similar. | — | — | — | 52,936 | |
| — | 9800.00 | — | — | ||
| Laying, testing and commissioning of LT cable in Air/Pole/Pipe/ Trench/ wall/cable tray etc. with complete lugs/glands and transportation of cable etc. Note- Cable will be supplied by Rly. from main depot. As per specification. | — | — | — | 2,54,800 | |
| — | 750.00 | — | — | ||
| Digging and filling of trench size 0.4 x 0.8 mtr as per spec. (trench work may be on kuchha/ pucca land and all type of soil as per site requirement and without protective layer of brick) Surface of trench shall be made good in all respect and satisfaction of site engineer. | — | — | — | 34,500 | |
| — | 1000.00 | — | — | ||
| Supply of HDPE pipe conforming to IS 4984:2016, 50 mm dia, minimum wall thickness 3 mm, PN 6, PE 80 as per requirement. (Inspection Clause : By Railway Representative) | — | — | — | 80,000 | |
| — | 1500.00 | — | — | ||
| Laying of HDPE pipe conforming to IS 4984:2016, 50 mm dia, minimum wall thickness 3 mm, under the road. The work involves laying of HDPE pipe along with transportation. | — | — | — | 15,000 | |
| — | 800.00 | — | — | ||
| Supply of HDPE pipe conforming to IS 4984:2016, 75/80 mm dia, PN 6, PE 80 as per requirement. (Inspection Clause : By Railway Representative) | — | — | — | 80,800 | |
| — | 800.00 | — | — | ||
| Laying of HDPE pipe conforming to IS 4984:2016, 75/80 mm dia, PN-6, PE-80 under the road. The work involves laying of HDPE pipe with transportation. | — | — | — | 11,200 | |
| — | 500.00 | — | — | ||
| Supply of HDPE pipe conforming to IS 4984:2016, 110 mm dia, PN-6, PE-80, as per requirement. (Inspection Clause : By Railway Representative) | — | — | — | 2,00,500 | |
| — | 500.00 | — | — | ||
| Laying of HDPE pipe conforming to IS 4984:2016, 110 mm dia, PN-6, PE-80, under the road. The work involves laying of HDPE pipe with transportation. | — | — | — | 7,500 | |
| — | 600.00 | — | — | ||
| Drilling of horizontal bore below Track/Road by pushing method (trenchless technology) for laying of RCC/HDPE/DWC pipe of various sizes up to 200 mm dia. in presence of Railway representative taking all necessary safety precautions related track and movement of trains. Horizontal boring will be done at minimum 1.5 Mtr. Below from ground level at railway track portion. | — | — | — | 8,77,200 | |
| — | 250.00 | — | — | ||
| Laying of Spun/MS/GI/HDPE pipe up to 200 mm by push through method in Railway yard/below track/Road. | — | — | — | 1,50,000 | |
| — | 12.00 | — | — | ||
| Supply and fixing of junction box size 390/388x305/304x170mm comprising of SMP/FRP material with rubber gasket, locking arrangement, zinc passivated earth bolt, etc. Make Sintex or similar with 4 no. aluminum busbar cap 200 Amp. Suitable for 415 volt supply requirement. The box shall be fixed robustly with clamps at pole/ wall as per requirement. All the material should be of good quality. | — | — | — | 30,780 | |
| — | 5.00 | — | — | ||
| Supply and fixing of junction box size 500X 450X100mm comprising of sheet steel 2mm thick, 60 micron powder coating / two coats of primer and finished by enamel paint- grey shade, with gland plates, neoprene EDPM/rubber gasket, locking arrangement, zinc passivated earth bolt, canopy etc. with 4 no. aluminum busbar cap 200 Amp., suitable for 415 volt supply requirement. The box shall be robustly fixed with clamps at pole/ wall as per requirement | — | — | — | 20,850 | |
| — | 20.00 | — | — | ||
| SITC of 4 meter length B Class 50 mm dia GI pipe earth station with digging pit & refilling with charcoal and salt as per IS and as per specification. | — | — | — | 33,260 | |
| — | 20.00 | — | — | ||
| Construction, supply and fixing of earth pit CC furnished chamber 300 x 300 x 250 mm, 50 mm thick with CI / RCC earth pit cover 300 x 300 x 25 mm with lifting hooked in center as per site requirement. | — | — | — | 14,560 | |
| — | 450.00 | — | — | ||
| Supply, laying and fixing of 25 x 5 mm GI earth strip at 0.5 meter below ground level or on walls/poles / along pipes etc., including connection / termination with GI nut, bolt, washer etc. as required (jointing shall be done by overlapping and with 2 sets of GI nut bolt & spring washer spaced at 50 mm). Note:- Suitable GI saddles with screws shall be provided to secure earth strips run on walls /floors etc. | — | — | — | 82,800 | |
| — | 6.00 | — | — | ||
| Supply / preparing of drawing in Auto CAD (Original + 2 copies) Jat Mat paper of 85/90 GSM showing over all electrical installation of Railway station as per specification | — | — | — | 25,980 | |
| — | 1200.00 | — | — | ||
| Supply, laying, connection and commission of sub-main 2x10 Sqmm with PVC insulated single core copper conductor cable and same size PVC insulated copper conductor for earthing wire in PVC conduit in recessed/ on surface as per site requirement etc. As per specification. | — | — | — | 4,14,000 | |
| — | 8100.00 | — | — | ||
| Supplying and drawing 6.0 sq. mm PVC insulated multistrand copper conductor cable as submain and 1.5 sq. mm PVC insulated multistrand earth copper cable voltage grade 1.1 kV as earthing wire conforming to IS: 694-1990 in existing conduit/casing caping. Wire should be of reputed make and as per tech. spec. | — | — | — | 4,94,100 | |
| — | 3000.00 | — | — | ||
| Supply and fixing of PVC conduit/ casing caping (as per instruction of site supervisor) and its accessories, size 25 mm, thickness1.6 mm MMS type As per IS 9537 part II. | — | — | — | 1,41,000 | |
| — | 3000.00 | — | — | ||
| Making and filling of chase for 25 mm dia PVC/MS conduit. Surface of chase shall be made good in all respect and satisfaction of engineer incharge. | — | — | — | 27,000 | |
| — | 1400.00 | — | — | ||
| Supply and installation of PVC trunking of size 35mm X 30 mm. This PVC Trucking shall be made up of High Quality Rigid Polyvinyl Chloride Material which is Fire Retardant & CE Certified, which adheres to international standards in all process of manufacturing, thus enduring a product which meets the high level of Quality and Safety. The installation work shall be executed to the satisfaction of Site Engineer. | — | — | — | 99,400 | |
| — | 24.00 | — | — | ||
| Supply and fixing of Double Door MCB TPN DB SP (8+12 module), neutral and earth link, 4 way with one no four pole MCB 63 amp, one no Four Pole RCCB 63 amp 30 mA and twelve no SP MCB 32/25/16/10/6 amp 'C' series as per specification. | — | — | — | 2,73,912 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing & commissioning of VTPN type metal double door type 8 way DB with having 01 No.250 Amp., 4 pole MCCB,36 KA as incomer & 8 Nos. TP MCB, 10 kA 'C' curves, 40-63 Amp. Cap. As outgoing having suitable IP-54,IK-09 protection. | — | — | — | 1,30,122 | |
| — | 250.00 | — | — | ||
| Supply and fixing of Re- Roll plug socket 20 amp with single pole 20 Amp MCB C Series & Re-Roll Plug Top of reputed make and as requirement and as per specification. | — | — | — | 2,73,750 | |
| — | 650.00 | — | — | ||
| Supply of material and laying of perforated GI cable tray of size 100mm X 50 mm with cover and all fixing arrangements as per specification and as per site requirement. (Inspection Clause : By Railway Representative) | — | — | — | 3,00,300 | |
| — | 400.00 | — | — | ||
| Supply of materials & laying of perforated GI cable Tray cable Tray 300 mm x 50mm with cover and fixing arrangement as per specification and as per site requirement. (Inspection Clause : By RITES ) | — | — | — | 5,24,400 | |
| — | 1500.00 | — | — | ||
| Supply and erection of G.I. perforated cable tray of size 200 mm x 100 mmx 100 mm on MS frame with cover - The price shall cover for fabrication, supply and fixing of M.S. perforated cable tray, hot dip galvanized as per latest ISS/BSS of size 200 x 100 x 100 mm and 2.0 mm approximate thickness with appropriate cover of thickness 1.6 mm. The cable tray shall be fixed horizontally or vertically at site and the existing LT cables shall be laid/ shifted in the cable tray by disconnecting from the panel/switch end and reconnecting as per site requirement duly tied with suitable clamps with GI nuts, bolts and washers in a safe and secure manner. The fixing clamps shall be fabricated from 50 x 50 x 6 mm MS angle or 50 x 6 mm MS flat duly painted and fixed at approximate distance of 1.5 to 2.0 meter apart with 2" long dowel/fisher rack bolts. The tray shall be fabricated in lengths of 2.0 m and couplers shall be provided at joints. The cable tray cover shall be fixed with GI screws. (Inspection Clause : By RITES) | — | — | — | 15,46,500 | |
| — | 72.00 | — | — | ||
| Supply, laying and fixing of GI pipe medium "B" class (Blue) confirming to IS 1239 part-I for passing incoming and outgoing cable from ground through it size 50 mm dia. Pipe should be of reputed make and as per tech. spec. | — | — | — | 16,200 | |
| — | 8.00 | — | — | ||
| Supply & Fixing ISI marked (IS : 15683 ) Portable Fire Extinguisher, CO2 type flat base including valve, discharge hose of not less than 10mm dia, min.600mm long & complete in all respects including initial fill with CO2 gas confirming to IS:307 of 1966 filled to a filling ratio of not more than 0.667 and wall suspension bracket capacity of 4.5 kg capacity. | — | — | — | 71,256 | |
| — | 2.00 | — | — | ||
| Supplying and Fixing of fire bucket stand made out of MS angle with one coat of primer and two coat of enamel paint of approved shade including platform and associated civil works each stand should have four nos fire buckets of 24 gauge galvanized steel sheet, standard 9 liter capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters "Fire" in black and gold at approved location as per direction of Engineer in charge. | — | — | — | 9,094 | |
| — | 12.00 | — | — | ||
| Supply and providing copper plate earthing 4.0 m deep size 600x600x3mm with 3.5m long G.I."B" class pipe 38 mm for pouring water with 50 Kg charcoal and 10Kg salt including RCC/masonry earth enclosure with pull out handle and 25x3 mm copper flat earth strip 4.0 mtrs long from earth pit bottom riveted to earth top . The earth value to be measured and marked on earth pit and as per specification attached. | — | — | — | 1,23,996 | |
| — | 220.00 | — | — | ||
| Supply, laying, connecting and testing of copper flat size 25 x 3 mm for connecting earth with equipment as per specification. | — | — | — | 1,10,000 | |
| — | 10.00 | — | — | ||
| Supply of unit maintenance free earth material as per RDSO Specs. No RDSO/PE/SPEC/PS/0/0109 (REV.0) 2008 or Latest. | — | — | — | 1,08,850 | |
| — | 10.00 | — | — | ||
| Installation of unit maintenance RDSO/PE/SPEC/PS/0/0109 (REV.0) 2008 or Latest. | — | — | — | 45,430 | |
| — | — | — | RDSO | ||
| — | — | — | Specs. | ||
| — | 1.00 | — | — | ||
| Preparation of electrical drawing & documents of power supply system for 11/0.415 KV electric substation required for EIG sanction, Checking of earth resistance of earthing, Meggering of all HT/LT power supply system before energisation of substation. Drawing to be supplied in original tracing fair hard copies (In auto cad). (As per specification) | — | — | — | 7,767 | |
| — | 55.00 | — | — | ||
| Material and labour for Construction of concrete M-20 masonry plinth above ground level with plastering for compact substation with provision for HT and LT cable incoming / outgoing all as specified. Note: (i) The foundations drawings shall be submitted and got approved from Railways prior to commencement of work at site. (ii) Necessary forms work, shuttering and finishing of surfaces are included in the scope of work and the quoted rates are deemed to be inclusive of this provision. | — | — | — | 4,07,880 | |
| — | 1200.00 | — | — | ||
| Supply and fixing of copper tube 3/8" with insulating material as per requirement. | — | — | — | 3,62,400 | |
| — | 1200.00 | — | — | ||
| Supply and fixing of copper tube 1/4" with insulating material as per requirement. | — | — | — | 1,44,000 | |
| — | 3000.00 | — | — | ||
| Supply and fixing of 1/2" PVC drain pipe as per requirement. | — | — | — | 2,04,000 | |
| — | 3.00 | — | — | ||
| Design, manufacturing, supply, testing, erection and commissioning of 4 way MCCB incomer & MCCB outgoing DB panel , fabricated from 1.6mm thick CRCA sheet, powder coated with IP 42 degree of protection, complete with 400 amp copper busbar, (Legrand cat part no. SD 2024 or similar), having provision for incomer 250 Amp, 4 pole 36kA MCCB - 1 no. and Outgoing - 63/100/125 amp 4 pole 16kA MCCB - 4 nos. Panel shall be manufactured from CPRI tested firm or should be of reputed switchgear manufacturer's make and as per tech. spec | — | — | — | 89,112 | |
| — | 3.00 | — | — | ||
| Supply, fixing and commissioning of 250 amps. 4 pole MCCB with adjustable thermal (70-100% of In) & fix magnetic trip unit, breaking cap 36 kA (min.) (Ics = 100% Icu) as incoming for DB. MCCB should be of reputed make and as per tech. spec. | — | — | — | 48,180 | |
| — | 12.00 | — | — | ||
| Supply, fixing and commissioning of 4 pole 100 amp. MCCB adjustable thermal (70- 100% of In) & fixed magnetic trip unit, breaking cap. 16 kA (min.) (Ics = 100% Icu) as outgoing for DB at item no. 2. MCCB should be of reputed make and as per tech. spec. | — | — | — | 58,596 | |
| — | 20.00 | — | — | ||
| Supply and fixing of 4 pole MCCB 63 Amp 35 kA (min) with adjustable thermal magnetic release complete with suitable size enclosure box. MCCB should be of reputed make and as per tech. spec. | — | — | — | 1,34,100 | |
| — | 60.00 | — | — | ||
| Supply, fixing, testing and commissioning of single phase, 230 volt, 50 Hz wall mounting/ bracket fan of sweep 400 mm. Fan should be of reputed make and as per requirement. | — | — | — | 1,05,840 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
JPOforprotectionofSTCables.pdf
ATTACHMENT
UpdatedGCCACSupto11.pdf
ATTACHMENT
T10of26-27R.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .