Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹41.4 L+₹2.6 L (6.66%)Rejected-Finance H NO 17036 9 STREET NO 5 A AGGARWAL COLONY BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L2 | Rejected-Finance L2 | |
| 3 | L3₹44.2 L+₹5.4 L (13.9%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
₹45.5 L
EMD Value
₹91,000
Closing Date
12 Feb 2020, 6:00 pmClosed
Shri Niranjan Lal, GE(S)BTD
GE(S) BATHINDA BATHINDA MIL STN
SPL REPAIR OF TAKSHILA AUDITORIUM PROVISION OF LIGHTING CONDUCTOR PROVISION OF SEWAGE DISPOSAL PIT FOR OVER FLOW OF WATER IN SUB GP AND CERTAIN OTHER SANCTIONED WORKS UNDER AGE BR I AND AGE EM IV UNDER GE SOUTH BATHINDA AT B
2020_MES_318833_1
GE (S) BTD-51/2019-20
Open Tender
Civil Works
Item Rate
180 days
BATHINDA MIL STN
AS PER NIT
7 documents required · 7 mandatory
₹500
GE(S) BATHINDA
₹91,000
Yes
22 Feb 2020
27 Jan 2020
14 Feb 2020
27 Jan 2020
12 Feb 2020
7 Feb 2020
28 Jan 2020 - 5 Feb 2020
Amount
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/losse soil & getting out complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches, not exceeding 1.5 m wide and exceeding 1.5m depth but not exceeding 3.0 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/losse soil & getting out complete all as specified and directed by Engineer-in-Charge.
Excavation over areas, not exceeding 1.5 m deep and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Excavation over areas, exceeding 1.5 m deep and not exceeding 3.0 m deep and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Excavation over areas, exceeding 3.0m deep and not exceeding 4.5m deep and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Excavation over areas, exceeding 4.5m deep and not exceeding 6m deep and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Excavation over areas, exceeding 6m deep and not exceeding 7.5m deep and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Excavation over areas, exceeding 7.5m deep and not exceeding 9m deep and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Excavation over areas, exceeding 9m deep and not exceeding 10.5m deep and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Returning filling in, approved soft/loosesoil, including spreading , levelling, watering and well ramming in layers, each layer not exceeding 25cm in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Removing surplus excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for precast cement concrete (1:2:4) type B1 using 20mm graded stone aggregate as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces and setting in mortar set in cement mortar (1:4) complete all as specified and as directed by Engineer-in-Charge.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed by Engineer-in-Charge.
Material and labour for cement concrete (1:4:8), type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete and sub base in floors etc complete all as specified and as directed by Engineer-in-charge.
Material and labour for cement concrete (1:2:4), type B-1 using 20 mm graded stone aggregate as in floors laid in alternate panels complete all as specified and as directed by Engineer-in-charge.
Forming Contraction (Dummy) joints grade 'A' 65mm deep x 10mm wide,filled with sealing compound complete all as specified and as directed by Engineer-in-charge.
Finishing surface of concrete roads, pavements, by brooming and making rough impressing on the top surface complete all as specified and as directed by Engineer-in-charge.
Material and Labour for Continuous brick edging with burnt clay of subclass brick 'B' with width equal to the length of the brick laid dry on end vertically including excavation complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for PCC (1:3:6) type C-2 using 40mm graded stone aggregate for foundations, fillings and mass concrete, for sub base under floors etc complete all as specified and directed by Engineer – in - Charge.
Material and Labour for PCC 1:2:4 type B-2 using 40mm graded aggregate as in foundation filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
Material and labour for hard core of broken bricks of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified & directed by Engineer-in- charge.
Use & waste of formwork to soffits of suspended slabs such as roof slab, floor slabs, landings and similar work not exc 200 mm thick (horizontal or sloping) for rough finished surfaces of concrete complete all as specified and as directed by Engineer-in-Charge.
Use & waste of formwork to (rough finished surface of concrete) edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20cm wide complete all as specified and as directed by Engineer-in-Charge.
Material and labour for reinforced cement concrete M-25 using 20mm graded stone aggregate as in slabs supported on walls, beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the like and in chajja etc complete all as specified and as directed by Engineer-in-Charge. (NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
Material and labour for mild steel TMT bars 10mm dia and over cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.)
Supply & fixing mild steel runs of 20mm dia TMT bars cut to length bent to shape, required complete all as specified and as directed by the Engineer-in-Charge.
Material and labour brick work with sub class `B' old size bricks straight or curved on plan exc 6.0m mean radius built in cement mortar 1:4 complete all as specified and directed by Engineer-in-charge.
Material and labour brick work with sub class `B' old size bricks straight or curved on plan exc 6.0m mean radius built in cement mortar 1:6 complete all as specified and directed by Engineer-in-charge.
M&L brick work with sub class 'B' old size bricks, straight or curved on plan to any radius in half brick walls built in CM (1:4), etc; complete all as specified and directed.
M&L brick work with sub class 'B' old size bricks, in one brick thick hone comb walling built in CM (1:4), etc; complete all as specified and directed.
M & L for flush pointing to brick walls in CM 1:3 including raking out joints/pointing etc. complete all as specified and directed.
Material and labour for loose filling with broken bricks of sub class B old size of gauge 80 to 150 mm in soakage pits, soakage wells complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for 15mm thick rendering in CM (1:4) on fair faces of brick work or concrete surfaces and finishing even & smooth using water proofing compund but without using extra cement complete all as specified and directed by Engineer-in-charge.. Note:- Water proofing compund shall be measured and paid separately in this BOQ.
Supply only water proofing compound as approved by GE from list of make attached in tender documents complete all as specified.
Material and Labour for 15mm thick rendering in CM (1:4) on fair faces of brick work or concrete surfaces and finishing even & smooth but without using extra cement complete all as specified and directed by Engineer-in-charge..
Material and Labour for 15mm thick rendering in CM (1:6) on other than fair faces of brick work or concrete surfaces and finishing even & smooth but without using extra cement complete all as specified and directed by Engineer-in-charge..
Taking down cement or cement lime plaster of any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specied and directed by Engineer-in-Charge.
M & L for preparation of new plastered surafaces of walls and applying two coats of oil bound distemper over a coat of suitable primer complete all as per manufacturer instructions and all as specified and directred by Engineer-in-Charge.
Material and Labour for rendering 5 mm thick in cement mortar in (1:3) on ceiling and finishing the surface even & smooth without using extra cement complete all as specified and directed.
Material and Labour for applying two coats of cement base paint over a coat of primer on newly plastered wall surfaces including cornices & pillasters etc as per manufacturer's specification & instruction including preparation of surface, complete all as specified and as directed by Engineer-in-charge.
Material and Labour for applying three coats of white wash on newly plastered or unplastered ceiling surfaces including preperation of surfaces, complete all as specified and directed by Engineer-in-Charge.
Material and labour for 40mm thick PCC (1:2:4), type B-1 using 20 mm graded stone aggregate as in floor finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.
Material and labour for 50mm thick PCC (1:2:4), type B-1 using 20 mm graded stone aggregate as in floor finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.
Material and Labour 75mm thick, cement concrete 1:3:6, type C2 using 40mm graded crushed stone aggregate as in sub base, floors, plinth protection, paths, etc and finishing top surfaces even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
S & F cast iron sand soil waste and vent pipe 100mm bore with or without ears fixed with chemical cement joints laid in trenches/floors or fixed in walls complete all as specified and directed.
Supply and fixing Salt-glazed stoneware drain pipes 150mm bore of grade 'A' laid in trenches and jointed etc. complete all as specified and directed by Engineer-in-Charge.
Material and labour for PCC (1:3:6) type C-2 using 40 mm graded stone aggregates as in concrete bed of (SGSW) drain pipes of 150 mm dia, laid to required slope including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed by Engineer-in-Charge. Note :- (i) Thickness of concrete bed below the barrel of pipe shall be 10 cm. (ii) Width of concrete bed shall be equal to outer dia of drain pipes (not of sockets / collar)
Supply and fixing three layers 500 liter HDPE water storage tanks polyproof. white in colour rotational moulded polyethylene (cylindrical vertical with closed top) hoisted and fixed in position including Supply and fixing of suitable size inlet/outlet arrangement & other accessories complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of size 20mm bore ( weight 210 gms Minimum) complete all as specified and as directed by Engineer-in-Charge.
M & L vitrified tiles 10 mm thick (square/ rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.36 Sqm, in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15mm thick screed bedding layer in CM 1:6 and including roughening surfaces of old concrete/terrazzo finish floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and directed by Engineer-in-Charge.
M & L vitrified tiles 10 mm thick (square/ rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, on vertical surfaces as in skirting etc. set and jointed in neat cement slurry/paste and pointed in white or coloured cement to match over and including 10mm thick plaster in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
Taking down shutters of any description exceeding 1.00 sqm but not exceeding 2.00 sqm each and refixing in the same opening including easing and adjusting including renewal of unserviceable screws etc. complete all as specified and directed.
Taking down chowkhats or frame with shutter (without taking off shutters from the frames) not exceeding 1.5 Sqm each exceeding and removal from site complete all as specified and as directed by Engineer-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) exc 1.5 sqm but not exc 4 Sqm each complete all as specified and as directed by Engineer-in-Charge.
Material and Labour machine pressed precast concrete coloured interlocking paver block any shape, size and pattern, IS - 15658-2006 (Marked) of 60 mm thickness of M-35 grade with grey cement & pigment complete all as specified and directed by Engineer-in-Charge.
Material and Labour for sand filling under interlocking tiles including watering and consolidation complete all as specified.
Supply and fixing powder coated anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engineer-in-Charge.
Supply and fixing powder coated Anodised aluminium door shutters,aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges,anodised aluminum snap beading screws etc. complete all as specified complete all as specified and directed by Engineer-in-Charge.
S & F stainless steel wire cloth 0.36 mm nominal dia of wire and avarage width of aperture 1.4mm and fixed with tinned tacks to stainless steel wire stapple complete all as specified and directed.
Supply and fixing three track aluminium powder coated sliding window using two tracks for glazed window shutter and one track for wire gauged shutter including provision of necessary rubber gasket for fixing glass panes/wire mesh etc complete all as shown in drawing No. CE BT/SK-936 sheet 1/1 available in AGE B/R-I office, all as specified and directed by Engineer-in-Charge. Note:- Sheet glass and stainless steel wire cloth shall be measured and paid separately under respective item.
Cutting openings, through brick walls built in cement mortar for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc. to store and rubbish not exc. 50m complete all as specified and as directed by Engineer-in-Charge.
Material and Labour Forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work in cement mortar 1:6 complete all as specified and as directed by Engineer-in-Charge.
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness, including cover fillets etc complete all as specified and directed by Engineer – in – Charge .
Supply and fixing anodised aluminium snap grid size 605mm x 605mm frame work for false ceiling consisting of aluminium powder coated main runner (32.50 x 23.50 x 0.8mm), cross tee (26.50 x 23.05 x 0.8 mm) and wall angle (20.30 x 20.30 x 0.8mm) respectively including material and labour hangers 6 mm dia. G.I. (upto1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long including small fittings such as steel dash fasteners, butterfly clips etc as per site requirement complete all as specified and as directed by Engineer-in-Charge.
Fixing only anodised aluminium snap grid size 605mm x 605mm frame work for false ceiling including fixing only hangers 6 mm dia. G.I. (upto1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing gypsum board 12mm thick in ceiling fixed with screw as per manufacturers instructions complete all as specified and as directed by Engineer-in-Charge.
Fixing only gypsum board 12mm thick in ceiling fixed with new screws complete all as specified and as directed by Engineer-in-Charge. Note:- Old gypsum board obtained from dismantling of ceiling in separate item of BOQ shall be used in this item
Dismantling water tanks and removing to store exceeding 250 ltr and not exceeding 500 ltr capacity complete all as specified and as directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) including tiles of any description & terrazo finish, etc. not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
M & L for appling a coat of cold bituminous primer over cleaned plastered surface @ 0.30 Kg/Sqm followed by APP modified five layer ploymeric membrane 3mm thick, minimum wt 3.60 kg/Sqm reinforced with polyester non-woven fabric (weighing not less than 150gms/Sqm ) as per list of make in tender documents, laid as per the manufactures instruction with side over lap of 75mm & end over lap of 100mm & tucked into the chases on vertical surfaces if required & finally finished with bituminous aluminum paint @ 0.10 Kg/Sqm complete all as specified and directed. Note:- Make will be approved by GE from list of make attached in tender documents before bulk procurement. Nothing extra shall be paid on this account.
Taking down carefully existing unserviceable copper / aluminum point wiring (light, fan, socket) complete including removal of unserviceable fittings such as switches, switch-sockets, ceiling roses, etc and removing the retrieved materials from dismantling including making good the disturbed surface of walls, floors, ceilings etc to match with the adjoining work complete all as specified and directed by Engineer-in-Charge.
Material and Labour for point wiring with multi stranded copper conductor FRLSH cable, 1100 volts grade PVC insulated and unsheathed of size 1.5 Sqmm single core in and including PVC concealed conduit not less than 20mm dia ( medium quality ISI marked) and conduit fittings and MS sunken box of suitable size covered with and including 3 mm thick bakelite laminated sheet top cover for one fan / light controlled by one switch including provision of 1.5 Sqmm PVC insulated unsheathed with single core, multi stranded copper conductor FRLSH cable as earth wire to common earth & connecting to earth dolly including cutting chasing of wall and making good disturbed surface in CM (1:3) and finishig the surface to match complete all as specified and directed by Engineer-in-Charge.Note:- (Switch and socket etc shall be measured and paid separately under approriate items of BOQ).
All as per item No. 74 here in before but for one socket outlet 6 pin, 6/16 Amp with cable of 2.5 Sq mm, multi stranded copper conductor FRLSH cable on the independent board including provision of 2.5 Sq mm PVC insulated unsheathed with single core, multi stranded copper conductor FRLSH cable as earth wire to common earth & connecting to earth dolly complete all as specified and directed by Engineer-in-Charge.
All as per item No. 74 here in before but for socket outlet 5 pin, 6 Amp on same board complete all as specified.
All as per item No. 74 here in before but for socket outlet 5 pin, 6 Amp on independent board complete all as specified.
All as per item No 74 here in before but for one light point controlled by two way switch complete all as specified and directed by Engineer-in-Charge.
All as per item No 74 here in before but for call bell point complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing modular switch piano, flush type, one way, 5/6 Amps 230 Volts AC (ISI marked) including decorative frame cover etc complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Switch piano, Modular flush type, two way, 5/6 Amps 230 V AC (ISI marked) including decorative frame cover etc complete all as specified and as directed by Engineer-in-Charge.
S&F 6 Amps bell push switch, modular type, 250 volts, AC ISI marked complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing call bell Ding-dong, 230 Volts AC supply complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing modular, One switch and one socket outlet, 5 Pin, 6 Amps 230 Volts AC (ISI marked) including decorative frame cover etc complete all as specified and as directed by Engineer-in-Charge. Note:- Switch and socket shall be of same make
Supply and fixing modular, One switch and one socket outlet, multipurpose 3 Pin, 5 Amp and 6 pin 15 Amp, 230 Volts AC (ISI marked) including decorative frame cover etc complete all as specified and as directed by Engineer-in-Charge. Note:- Switch and socket shall be of same make
Supply and fixing ceiling rose surface bakelite 65mm x 50mm, 3 terminals with back plate etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing modular type regulator for ceiling fan electronic step type suitable for 1200/1400 ceiling fan complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED ceiling light 1x12 W, 230 volt, including electrical connections with 1.5 mtr long twin core round copper conductor cable of suitable size all as per Havells cat part No. EDGEPRORDDLR12WLED857S or equivalent model of approved make from list of make attached in tender documents complete all as specified and as directed by Engineer-in-Charge.
S & F LED light luminaire 1x10 watt 2 ft including electrical connections with 1.5 mtr long twin core round copper conductor cable of suitable size all as per Havells cat part No. LHEOAOP7UZ6W010 or equivalent model of approved make from list of make attached in tender documents complete all as specified and as directed by Engineer-in-Charge.
S & F ultra bright integrated aluminium heat sink LED tubelight 20 W / 22 W with high efficacy suited for installation in existing T8 No. (TITANIANEO1213T8SSTL20WLED865SPC) of Havells. The tube will be fitted in regal batten for LED tube which is universal batten for T5 or T8 lamps, Cat Part no. (REGALBATTENT8UPTO1X22WSSBSWH) of Havells including electrical connections with 1.5 mtr long twin core round copper conductor cable of suitable size all as per Havells cat part No. LHEOAOP7UZ6W010 or equivalent model of approved make from list of make attached in tender documents complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing MCB, SP, 6 to 32 Amps, 'C' curve, 230 Volts, breaking capacity not less than 10 KA with over load and short circuit protection complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing MCCB 4 pole, 415 volt, fixed type, 250 Amp with braking capacity 16KA, 'C' series complete all as specified and directed by Engineer-in-Charge.
Supply and fixing MCB, SPN, 40 to 63 Amp, 230 Volts, 'C' curve breaking capacity not less than 10 KA with over load and short circuit protection,50 Hz including necessary attachment complete all as specified and as directed by Engineer-in-Charge
Supply and fixing MCB, TPN, 63 to 100 Amp, 230 Volts, 'C' curve breaking capacity not less than 10 KA with over load and short circuit protection,50 Hz including necessary attachment complete all as specified and as directed by Engineer-in-Charge
Supply and fixing one module blanking plate of suitable size to fit in distribution board complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing sheet metal enclosures double door made out of CRCA mild steel sheet, flush mounted, acrylic door, 8 way, DB SPN 230 Volts, with 200 Amp rated bus bar, dust and vermin proof suitable for fixing MCB's and Isolators etc complete all as specified and as directed by Engineer-in-Charge.
S & F sheet metal enclosures double door made out of CRCA mild steel sheet, flush mounted, acrylic door, 4 way, DB TPN 415 Volts, with 200 Amp rated bus bar, dust and vermin proof suitable for fixing MCB's and Isolators etc complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp 240 Volt complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for sub main wiring with 2 single core cable 4 sqmm, 1100 votls grade PVC insulated unsheathed of copper multi strandard conductor FRLSH cable with continuous copper earth conductor of size 4 sqmm, 1100 votls grade drawing through in & including PVC concealed conduit medium grade of size 20mm along with accessories such as Tee, elbow, bend etc complete all as specified and as directed by Engineer-in-Charge. Note :- Two runs of cable and one run of earthing wire shall be measured as one unit.
Material and Labour for sub main wiring with 2 single core cable 6 sqmm, 1100 votls grade PVC insulated unsheathed of copper multi strandard conductor FRLSH cable with continuous copper earth conductor of size 6 sqmm, 1100 votls grade drawing through in & including PVC concealed conduit medium grade of size 20mm along with accessories such as Tee, elbow, bend etc complete all as specified and as directed by Engineer-in-Charge. Note :- Two runs of cable and one run of earthing wire shall be measured as one unit.
Supply and fixing environment friendly non intergral flood light LED 180W IP66 with excellent heat dissipation, light in weght and small in size with system high lumen efficancy including fixing with suitable size clamps, nuts bolts, proper connection etc complete all as specified and directed by Engr-in-Charge. Make:- Havells Cat Part No. JETAVALOURFLS180WLED757MODASYMLTG or equivalent model of any make given in Appendix 'B' of tender documents, Cat Part No. as approved by GE. Note:- (i) The point wiring with 2.5sqmm shall be measured under approriate item of this BOQ. (ii) Contractor shall deploy experienced labour with proper arrangement like ladder, tools etc as per ground requirement and all safety precautions shall be proivded by contractor to the labour during execution of work. Nothing extra shall be paid on this account. (iii) The contractor shall provide original purchase voucher , test certificate,IM-79 report from manufacturer of LED light. (iv) Contractor shall provide unconditional warranty of LED fittings for minimum two years from actual date of completion of this contract aggrement. (v) Cost of taking down of old fittings and deposting to store yard of AGE E/M -IV is deemed to included in the quoted rate. Nothing extra shall be paid on this account. (vi) The contractor should visit the site before quoting the rate.
Supply and fixing environment friendly flashbay light LED 80W IP66 with excellent heat dissipation, light in weght and small in size with system high lumen efficancy including fixing with suitable size clamps, nuts bolts, proper connection etc complete all as specified and directed by Engr-in-Charge. Make:- Havells Cat Part No. FLASHBAYCAR80WLED757SBOLTG or equivalent model of any make given in Appendix 'B' of tender documents, Cat Part No. as approved by GE. Note:- (i) The point wiring with 2.5sqmm shall be measured under approriate item of this BOQ. (ii) Contractor shall deploy experienced labour with proper arrangement like ladder, tools etc as per ground requirement and all safety precautions shall be proivded by contractor to the labour during execution of work. Nothing extra shall be paid on this account. (iii) The contractor shall provide original purchase voucher , test certificate,IM-79 report from manufacturer of LED light. (iv) Contractor shall provide unconditional warranty of LED fittings for minimum two years from actual date of completion of this contract aggrement. (v) Cost of taking down of old fittings and deposting to store yard of AGE E/M -IV is deemed to included in the quoted rate. Nothing extra shall be paid on this account. (vi) The contractor should visit the site before quoting the rate.
Supply and fixing environment friendly energy saving LED street light 45W IP66 with excellent heat dissipation, light in weght and small in size with system high lumen efficancy including fixing with suitable size clamps, nuts bolts, proper connection etc complete all as specified and directed by Engr-in-Charge. Make:- Havells Cat Part No. ENDURACITYLINERNEXGENSL45WLESD757SASYBOPC or equivalent model of any make given in Appendix 'B' of tender documents, Cat Part No. as approved by GE. Note:- (i) The point wiring with 2.5sqmm shall be measured under approriate item of this BOQ. (ii) Contractor shall deploy experienced labour with proper arrangement like ladder, tools etc as per ground requirement and all safety precautions shall be proivded by contractor to the labour during execution of work. Nothing extra shall be paid on this account. (iii) The contractor shall provide original purchase voucher , test certificate,IM-79 report from manufacturer of LED light. (iv) Contractor shall provide unconditional warranty of LED fittings for minimum two years from actual date of completion of this contract aggrement. (v) Cost of taking down of old fittings and deposting to store yard of AGE E/M -IV is deemed to included in the quoted rate. Nothing extra shall be paid on this account. (vi) The contractor should visit the site before quoting the rate.
S & F LED light fitting 15W New generation energy saving and environment friendly long life LED EDGE LIT luminaire suitable for armstrong grid ceiling complete. The driver shuld be procured separatly but the quoted rate should be inclusive of both fitting and driver. The fixture size in mm is 295x295x70. The module and the driver should be ordered at the same time complete with all accessories internly prewired and fixing on wall or ceiling by using twin core flexible cable 23/0.00076 from ceiling rose to LED light fittings connection complete all as specified and as directed by Engineer-in-Charge. Make:- Havells Cat Part No. PLUTO1X1PLR15WLED840S or equivalent model of any make given in Appendix 'B' of tender documents, Cat Part No. as approved by GE.
S & F LED light fitting 34/36W New generation energy saving and environment friendly long life LED EDGE LIT luminaire suitable for armstrong grid ceiling complete. The driver shuld be procured separatly but the quoted rate should be inclusive of both fitting and driver. The fixture size in mm is 1195x295x70. The module and the driver should be ordered at the same time complete with all accessories internly prewired and fixing on wall or ceiling by using twin core flexible cable 23/0.00076 from ceiling rose to LED light fittings connection complete all as specified and as directed by Engineer-in-Charge. Make:- Havells Cat Part No. PLUTONEO4X1PLR36WLED840S or equivalent model of any make given in Appendix 'B' of tender documents, Cat Part No. as approved by GE.
S & F LED light fitting 34/36W New generation energy saving and environment friendly long life LED EDGE LIT luminaire suitable for armstrong grid ceiling complete. The driver shuld be procured separatly but the quoted rate should be inclusive of both fitting and driver. The fixture size in mm is 595x595x70. The module and the driver should be ordered at the same time complete with all accessories internly prewired and fixing on wall or ceiling by using twin core flexible cable 23/0.00076 from ceiling rose to LED light fittings connection complete all as specified and as directed by Engineer-in-Charge. Make:- Havells Cat Part No. VENUSNEOHE2X2PLR36WLLED8XXS or equivalent model of any make given in Appendix 'B' of tender documents, Cat Part No. as approved by GE.
Taking down servicable/ unserviceable ceiling fans 1200mm/1400mm sweep 230 V, AC, single phase from building, dismantling the ceiling fan and taking out complete burnt winding from fan motor and rewinding the same with super enameled copper winding wire of existing gauge & size including thoroughly cleaning all the components of fan, oiling, varnishing the fan with and including replacement of rusted/unserviceable nuts, bolts, split pin, rubber reel, flexible twin core copper cable of size 23/.00076 approximate one metre long for each fan, machine screws and painting the fans etc and refixing the repaired fan to the respective building complete all as specified and as directed by Engineer-in-Charge.
Taking down servicable/ unserviceable wall fans upto 300mm sweep 230 V, AC, single phase from building, dismantling the wall fan and taking out complete burnt winding from fan motor and rewinding the same with super enameled copper winding wire of existing gauge & size including thoroughly cleaning all the components of fan, oiling, varnishing the fan with and including replacement of rusted/unserviceable nuts, bolts, split pin, rubber reel, flexible twin core copper cable of size 23/.00076 approximate one metre long for each fan, machine screws and painting the fans etc and refixing the repaired fan to the respective building complete all as specified and as directed by Engineer-in-Charge.
Taking down servicable/ unserviceable exhaust fans upto 200/225/300/450mm sweep 230 V, AC, single phase from building, dismantling the exhaust fan and taking out complete burnt winding from fan motor and rewinding the same with super enameled copper winding wire of existing gauge & size including thoroughly cleaning all the components of fan, oiling, varnishing the fan with and including replacement of rusted/unserviceable nuts, bolts, split pin, rubber reel, flexible twin core copper cable of size 23/.00076 approximate one metre long for each fan, machine screws and painting the fans etc and refixing the repaired fan to the respective building complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully to existing decorative type updown wall light fixture and refixing the same after rewiring and before handing over the site complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully to existing step light and refixing the same after rewiring and before handing over the site complete all as specified and as directed by Engineer-in-Charge.
M & L for supply and fabricating of main distriution box of size (1.2x0.8x0.3)m thickness 2.25 mm double door single opening with lock arrangement suitable for fixing of MCBs /DBs, TNP, MCCB atc complete and fixing in wall with suitable cutting cement work etc all as direced.
S & F test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos, 8mm dia and 25mm long hex. head screw complete all as specified and as directed by Engineer-in-Charge.
S & F air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and as directed by Engineer-in-Charge.
S & F aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and as directed by Engineer-in-Charge.
S & F galvanised iron strip 32 x 6mm buried in ground complete all as specified and as directed by Engineer-in-Charge.
Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (PCC 1:2:4 B-1 using 20 mm graded stone aggregates for concrete pit including 10 mm thick PCC slab cover frame) depth of pit not less than 2.25 m below normal ground level with top edge of the plate not less than 1.5 m below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal / coal dust and common salt filling in alternate layers and connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts check nuts and washers of GI or steel and connecting to earthing test point, main switch board, testing on completion including GI pipe 20 mm dia light grade for watering and bringing out the watering pipe upto 30 cm above the normal ground level plugged at top including all fitting and GI pipe 15 mm dia light grade for the protection of GI wire from earth pit to earth point, all as specified as shown in electrical plate No 3 SSR Part-I and testing on completion complete all as specified and as directed by Engineer-in-Charge. Note :- PCC chamber shall be constructed at least 1.5 m away from earth pit pipe for watering shall be provided in slanting manner.
M&L for earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6.0mm buried directly in ground, vertically to depth not less than 2.25mtr below normal ground level with top edge of the earth plate at depth not less than 1.5 metre below ground level surrounded from all sides with alternate layers of charcoal and common salt and connected to GI strip of size 25x4mm by means of GI bolts, nuts washers & check nuts electrode connected to main switch board or main control board or on poles or on transformer and GI pipe medium grade 20mm bore for watering, 32mm bore GI pipe light grade for protection of GI strip upto test point including providing funnel and wire mesh GI frame and 10cm thick suitably reinforced RCC pit cover PCC chamber pit with PCC (1:2:4) type B-1 using 20mm graded stone aggregates complete including excavation and earth work in any type of strata, disposal of surplus soil to a distance not exceeding 50 mtr all as specified ans shown in plate No. 3 SSR Part-1, PCC pit shall be provided at least 50 cm away from the earth pit and not just on earth pit including testing on completion complete all as specified and directed by Engineer-in-Charge.
Supply and fixing powder coated aluminium snap grid size 605mm x 605mm frame work for false ceiling consisting of aluminium powder coated main runner (32.50 x 23.50 x 0.8mm), cross tee (26.50 x 23.05 x 0.8 mm) and wall angle (20.30 x 20.30 x 0.8mm) respectively including material and labour hangers 6 mm dia. G.I. (upto1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long including small fittings such as steel dash fasteners, butterfly clips etc as per site requirement complete all as specified and as directed by Engineer-in-Charge.
M/s MITTAL CONSTRUCTIONS
KARTIK BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .