Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹64.5 LAccepted-Finance | L1 | Accepted-Finance Being lowest | |
| 2 | L2₹64.9 L+₹35,095 (0.54%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹69.3 L+₹4.8 L (7.44%)Rejected-Finance MB 58 JUNGLIGHAT KATHIR MARKETING SERVICE MB 58 JUNGLIGHAT NEAR TCI OFFICE SOUTH ANDAMAN ANDAMAN NICOBAR 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹71.1 L+₹6.5 L (10.1%)Rejected-Finance | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹72.0 L+₹7.5 L (11.5%)Rejected-Finance 702 MODEL TOWN PHASE 3 BATHINDA PUNJAB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L5 | Rejected-Finance Not being lowest |
Tender Value
₹72 L
EMD Value
₹1.3 L
Closing Date
7 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Abhay Manglik, IDSE
HQ Commander Works Engineer No.2, Brichgunj, Junglighat Post, Port Blair - 744 103
PROVN OF 03 NOS PORTA CABIN AT OLD OTM COMPLEX FOR DIVING CELL, LAY APART STORE AT CGDHQ-9, AERIAL BAY, DIGLIPUR
2020_MES_350708_1
80180/E8
Open Tender
Civil Works
Item Rate
180 days
Diglipur
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (South) Diglipur
₹1.3 L
Yes
17 Jul 2020
10 Jun 2020
11 Jul 2020
10 Jun 2020
7 Jul 2020
23 Jun 2020
10 Jun 2020 - 16 Jun 2020
60 days
Amount
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/loose soil all as specified and directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, etc and getting out in any type of soil all as specified and directed.
Excavating in trenches not exceeding 1.5 m wide and depth exceeding 1.5 m but not exceeding 3.0 m for foundation, etc and getting out in any type of soil all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layer n.exc 25 cm using soil obtained from excavation all as specified and directed.
Materal and labour for sand (obtained from main land) filling under foundation including watering and well ramming in layers complete all as specified.
Materal and labour for Moorum/red bajri filling in floors or pavings including spreading levelling watering and well ramming in layers n.exc 15 cm all as specified and directed.
Removing excavated material to a distance n. exc. 50 m and depositing where directed at a level n.exc. 1.5 m above the starting point all as specified and directed by Engineer-in-charge.
Material and labour for Hardcore with broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface all as specified and directed.
Material and labour providing Cement Concrete in foundations, filling and mass concrete type C2 ,1:3:6 (using 40 mm graded aggregate) complete all as specified .
Material and labour for providing Cement Concrete in foundations, filling and mass concrete type D2 ,1:4:8 (using 40mm graded aggregate) complete all as specified .
Material and labour precast cement concrete block with 1:3:6 type C1 using 20mm graded stone aggregate for block masonry with solid blocks exc 10cm in width and setting in cement mortar 1:6 complete all as specified.
Material and labour Reinforced cement concrete design mix M-30 (using 20 mm graded stone aggregate) for foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete all as specified and directed.
Material and labour Reinforced cement concrete design mix M-30 (20 mm graded aggregate) for column, pillars, piers, posts and struts all as specified and directed.
Material and labour Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement , including forms, moulds, mitred/stopped ends etc complete all as specified
Supply only Integral water proofing compound complete all as specified and directed.
Material and labour Damp proof course 40 mm thick in cement concrete 1:2:4 type B-0,using 12.5mm graded stone aggregate including necessary form work with WPC as per manufacturer instruction by weight of cement. Note:- WPC shall be measured and paid separately under nrelevent item of this schedule.
Use and waste of formwork using steel shutter flat to sides of concrete foundations, footings, bases of columns, and plinth beams and similar work vertical or to batter rough finished surfaces of concrete all as specified .
Use and waste of formwork using steel shutter flat to sides of concrete of pillars, posts, struts, piers, and beams exceeding 1.5m span columns and stanchions square, rectangular or polygonal fair finished all as specified.
Material and labour Mild steel TMT Bars 10mm dia and over cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with MS wire (annealed ) not less than 0.9mm dia., or securitn with clips
Material and labour Mild steel TMT Bars 5 dia and over up to and including 10mm dia as in stirrups cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with MS wire (annealed ) not less than 0.9mm dia., or securitn with clips all as specified.
Material and labour Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge.
Material and labour Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in ridges, hips, valley gutters, drip and straight flashing, eaves board etc, cut to length and bend to shape and fixed with self tapping screws complete all as specified and directed by Engr-in-Charge.
Material and labour for 4 mm thick corrugated translucent poly carbonate sheet white shade fixed with screws etc in roof, profile matching with corrugugated galvalume complete all as specified and directed by Engr-in-Charge.
Material and labour Providing PCC 1:3:6 types C1 (using 20mm graded stone aggregate) 75mm thick as in plinth protection, with necessary expansion joints as specified in SSR, finishing cement concrete surface even and fair without using extra cement.
Material and labour 75mm thick PCC 1:4:8 type D-2, (using 40mm graded aggregate) as in sub base to floor etc complete all as specified.
Material and labour 100mm thick PCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in sub base complete all as specified.
Material and labour 50mm thick Cement Concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in floor including finishing the cement concrete surface to receive the fixing of tiles complete all as specified.
Material and labour 150mm thick cement concrete 1:2:4 type B2 (using 20mm graded stone aggregate) as in floor/hard standing including finishing cement concrete surface even and smooth and finally finishing the surface by belting/brooming without using extra cement complete all as specified.
Material and labour rendering 10mm thick in cement mortar 1:6 on fair faces of brick/concrete surfaces finished even and smooth with out using extra cement complete all as specified.
Material and labour rendering 15mm thick in cement mortar 1:4 on fair faces of brick/concrete surfaces finished even and smooth with out using extra cement complete all as specified.
Material and labour rendering 5 mm thick in CM 1:4 over backing coat of 10 mm thick in C M 1:6, complete, the 5mm thick finishing coat shall be mixed with water proofing compound @3% by weight of cement and finished even and smooth without using extra cement all as specified and directed Note:-WPC shall be measured and paid separately under relevent item of this schedule.
Material and labour applying two coats of cement base paint over a coat of primer on new plaster or untreated surfaces on walls including preparation of surfaces all as specified.
Supply and fix joist, channel, angle, or tee sections, fixed independently, without connecting plates etc cut to ordinary lenght i.e. within 20mm of the lengths indicated made out of rolled mild steel of grade Fe-410W (Gde E- 250) quality-B, complete all as specified and directed.
Supply and fix Mild steel work in tubular trusses and tubular posts/ purlins including special shaped washers etc., complete using ERW or induction butt welded tubes conforming to IS :1161-1979 grade St-240 including notching, drilling, fitting, riveting and/or welding or connecting with bed plate, bolt and nuts complete all as specified and as directed
Supply and fix framed steel work as in plates (plain or chequred) channels, square cut or notched with fabrication and errection of FE 410-W (Gde E-250) Quality A (ordinary and counter sunk) forming holes without any attachment complete all as specified and directed
Supply and fix Mild steel screw bolts (machine made) 7.5 Cm long, 12 mm dia with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut complete all as specified and directed
Supply and fix mild steel flat iron 40 x 3mm as in wind tie including all necessary drilling, bolting or riveting etc.confirming to Fe 290 Gde E-165 all as specified and directed.
Material and labour for preparation of new steel surfaces of any description over 10cm width/girth and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed.
Supply only aluminium alloy wire mesh 0.45mm nominal dia of wire and average width of aperture 1.40mm complete all as directed.
Forming 12mm thick & 150mm deep expansion joints filled with pre-formed bituminous filler and top 30 mm primed and sealed with sealing compound, Grade ‘B’ complete all as specified .
Material and Labour point wiring fixed on wall of plastocrete panel/ laying on top surface of false ceiling , controlled by one, one way switch, using 1.5 sqmm nominal cross sectional area multistranded copper conductor 1100V, PVC insulated unsheathed (FRLS), single core cables in and including 20mm dia, medium grade PVC conduit, with 1.5 Sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS earth wire etc, excluding terminal boxes all as specified for following:-
One light point controlled by one way switch 5/6 amps.
One socket out let 5/6 amps point on the same board
Supply and Fix PVC box type switch Socket out let 3&2 pin 5A, 240 V, flush type universal controlled by one switch with ISI mark complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing switch piano flush type 5/6 amps single pole one way all as specified. Make : Anchor Penta/ Havell's Reo
Supply and Fixing MCB, SP, 5 to 32 Amps, 240 Volt, 10 KA complete all as specified and directed.
Supply and Fixing MCB, SPN, 20 Amps, 240 Volt, 10 KA complete all as specified and directed.
Supply and Fixing MCB TPN 32 Amps, 240 Volt, 10 KA complete all as specified and directed.
Supply & Fixing ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and directed.
Supply and fix sheet metal enclosure distribution board, SPN, 4 way, 240 volts, 200 amps rated bus bar, with IP 43 protection and double door, suitable for fixing MCBs/isolators including blanking plates complete all as specified and as directed.
Supply and fix sheet metal enclosure distribution board, TPN, 4 way, 240 volts, 200 amps rated bus bar, with IP 43 protection and double door, suitable for fixing MCBs/isolators including blanking plates complete all as specified and as directed.
Supply & Fixing LED street light fitting 1 x 15W, complete fixed on wall incl 1.2 m light grade GI pipe, 25 mm dia bend to shape at an angle og 120 degree, suitable fixing clamps etc, providing connections with PVC insulated sheather copper conductor cable from ceiling rose to connector complete all as specified and directed.
Supply & Fixing energy efficient light fitting on surface and wall mounted LED batten 20 Watt, extruded aluminum housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver, diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hrs all as directed Make : Cat Part No LTT8-20 of CG or equivalant in Philips, Wipro, Bajaj.
Supply and spreading clean dry river sand to the full width of trenches for protection of cables including spreading and punning down including consolidation complete all as specified and directed. Note : Punned thickness will be measured and paid under this item
Supply and laying unreinforced Precast Cement Concrete Cable Covers, class LV, Type - 1, Flat, size 250mm X 150mm X 40mm made out of M-30 grade PCC as per IS-5820 : 1970, in trenches for cable protection, embossed with " ELECTRIC" on the top surface complete all as specified and as dircted.
Supply, laying, jointing, connecting, testing and commissioning of LT UG cable XLPE of size 2.0 core 10 sqmm, insulated PVC sheathed multistranded armoured heavy duty electric aluminium conductor cable 1100 volts grade laid in trenches/fixed to poles / fixed on wall/ drawn through pipes with suitable size cable glands, crimping type cable lugs etc. complete all as specified and directed
Supply, laying, jointing, connecting, testing and commissioning of LT UG cable XLPE of size 4.0 core 10 sqmm, insulated PVC sheathed multistranded armoured heavy duty electric aluminium conductor cable 1100 volts grade laid in trenches/fixed to poles / fixed on wall/ drawn through pipes with suitable size cable glands, crimping type cable lugs etc. complete all as specified and directed
Supply and laying light grade GI pipe of dia 40 mm with all fittings laid in trenches for cable protection all as specified and as directed by Engineer -in-Charge.
Material and Labour for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick buried directly in ground ( earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less thab 1.5 Meter below normal ground level connected to GI wire 4 mm dia as main earthing lead (upto 7.5 m length from earth electrode to test point) by means of bolts, nuts , check nuts and GI washers and GI tubing 20 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1, pre cast RCC (1:2:4) type B1 as in cover slab 54 x 54 x 5 cm including 8mm dia MS TMT bars @ 150 mm c/c as in reinforcement with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing (Light Grade) for watering, charcoal or coal and salt in alternate layers including excavation earth work in any type of soil, RFR and removal of surplus soil complete all as specified and directed electrical plate No. 3 of SSR part - I
RADHA GOVIND CONSTRUCTION
Kathir Marketing Services
AMR TRADERS
SACKSON ENTERPRISES
M/s V M K Construction
BHARAT MULTITECH INDUSTRIES PVT LTD
DHAKSHNA MOORTHY AND SON
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .