| 1 | L1₹5.4 LAccepted-Finance | ₹5.4 L | L1 | Accepted-Finance ACCEPTED IN THE TECH EVALUATION |
| 2 | L2₹5.6 LAccepted-Finance | ₹5.6 L | L2 | Accepted-Finance ACCEPTED IN THE TECH EVALUATION |
| 3 | L3₹5.6 LAccepted-Finance | ₹5.6 L | L3 | Accepted-Finance ACCEPTED IN THE TECH EVALUATION |
| 4 | Rejected-Technical SRIBHUMI PALLY VILL P O SURI DIST BIRBHUM PIN 731101 | SURI | BIRBHUM | WEST BENGAL | 731101 | - | - | Rejected-Technical Affidavits not submitted |
Tender Value
₹5.5 L
EMD Value
₹10,902
Closing Date
22 Jan 2026, 9:00 amClosed
Secretary, BZRMC
PROVAT SARANI, BOLPUR, BIRBHUM
CONSTRUCTION OF OFFICE INFRASTRUCTURE FOR AGRICULTURAL MARKETING OFFICER (ADMIN) AT 1ST FLOOR OF THE KRISHAK SAHAYAK BUILDING AT SURI-1 KRISHAK BAZAR
2026_WBSMB_985683_1
BZRMC/13/2025-26
Open Tender
CIVIL AND ELECTRICAL WORKS
90 days
sURI 1 kRISHAK bAZAR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
₹10,902
Yes
23 Mar 2026
14 Jan 2026
27 Jan 2026
14 Jan 2026
22 Jan 2026
14 Jan 2026
Dismantling allt ypes of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at siteand removing rubbish asdirected within a lead of 75 m. In first floor
125 mm. thick brick work with 1st class bricks in cement mortar (1:4). Extra for using approved H.B netting in every third layer. first floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] In first floor (a) 20 mm. thick plaster (External) , (ii) With 1:6 cement mortar
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) Pakur Variety
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation and upto roof of ground floor/upto 4 m . (Lead consider 75Km) I. SRMB/ Elegant/ Captain/ Balaji/ Sakti/ Hexa
(a) M.S.or W.I. Ornamental grill of approved design joints continuouslyweldedwithM.S, W.I. Flats and bars of windows, railingetc. Fitted and fixed with necessarys crews and lugs in ground floor. (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. (3rd corri.)
Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall) 4mm thick (P-205, I-1)
Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using ...... adhesive and grout material to be supplied by the contrr]e) (I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment. (a) ln Ground FIoor:(size not Iess than 600mmX 600 mm X 9.5 mm thick)
Supplying, fitting & fixing1st quality Ceramic tiles in walls and floors to match with the existing work & 4nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (A) Floor With Sand Cement Mortar (1:4) 20mm thick &2mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. a) Area of each tile upto 0.09 Sq.m Coloured Decorative
-do- (B) Wall With Sand Cement Mortar (1:4) 20mm thick &2mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. a) Area of each tile upto 0.09 Sq.m Coloured Decorative
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor:(b) Two Coats
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor (Two Coat) a) Normal Acrylic Emulsion
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary b) On steel or other metal surface : (iv) Two coats (with any shade except white)
Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with37.5mm wide batten splacesboth ways in order to make thedoor of solid core and internal lipping with Garjanor similar wood veneers using phenol formal dehydeasglue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in First floor. 32mm thick
Woodwork in door andwindow frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete Iron Butt Hinges and M.S clamps.(The quantum should be correted upto three decimals). 1st floor
Sanitary and Plumbing works
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC)in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish) Average run 8 mtr (E-24 Sl No- 1/c)
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR'PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20 mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch boardwith 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works. On Board (E-24 Sl No- 3/a)
Supplying and Drawing 1.1 KV single core stranded 'FR' PVCi nsulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necessary connection as required a) 2x36/0.3(2.5 sqmm) + 1x22/0.3(1.5 sqmm) as ECC (E-9 Sl No- 1/s)
b) 2x56/0.3(4 sqmm) + 1x36/0.3(2.5 sqmm) as ECC (E-9 Sl No- 1/v)
c) 2x80/0.4(10 sqmm) + 1x84/0.3(6 sqmm) as ECC (E-9 Sl No- 1/b1)
d) 4x126/0.4(16 sqmm) + 2x80/0.4(10 sqmm) as ECC (E-9 Sl No- 1/g1)
Supplying and fixing PVC Rigid Conduit 'FR' [PrecisionMake] on wall,ceiling with saddles and other accessories as required and mending good damages to building works a) 20 mm size(E-16 Sl No- 7/a)
b) 25 mm size(E-16 Sl No- 7/b)
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. a) 2.5 Sqmm (F-5 sl no- 9/i)
b) 4 Sqmm (F-5 sl no- 9/ii)
c) 6 Sqmm (F-5 sl no- 9/iii)
d) 10 Sqmm (F-5 sl no- 9/iv)
e) 16 Sqmm (F-5 sl no- 9/v)
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment 4 way Enclosure (607715) (Make- Legrand) (D-10 sl no- 14)
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish including Interconnection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make- Legrand) 2+8 way Enclosure (607711) (D-9 sl no- 13)
Supplying and fixing 240/415V MCB Isolatoron din rail of existing DBs and necessary connection 63A FP (Make Legrand) (D-5 sl no- 6)
Supplying and fixing 240/415V MCB Isolatoron din rail of existing DBs and necessary connection 40A DP (Make Legrand) (D-5 sl no- 6)
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection 6-32A SP MCB (Make Legrand) (D-6 sl no- 7)
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3nos. DIN type HRC fuse as per rating 63A (Make L& T) (D-3 sl no- 4)
Supplying and fixing sheet steel (16SWG) cable end box onTPN SFU enclosure with nuts bolts etc incl. powder coated painting 63/125A (D-5 sl no- 5)
Supply & Fixing 240 V, 3 nos. 16 A, 3 pin Modular type plug socket with 3 nos. 16A Modular type switch (Brand approved by EIC), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 12 Module GI Modular type switch board with 12 Module top cover plate flushed in wall including S & F switch board and cover plate and making necessary connections with PVC Cu wire and earth continuity wire etc (E-19 sl no- 14)
Supply & Fixing240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necessary connections with PVC Cu wire and earth continuity wire etc. (E-17 sl no- 5/a)
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC)on existing Modular GI switch board with top cover plate incl. making necessary connections etc (E-18 sl no- 10)
a) Supplying & Fixing GI Modular Switch Board ofthe following sizes complete with top cover plate flushed in wall for housing the board after cutting the brick wall including making earthing attachment, painting and mending good damages to building works 2Module (E-17 sl no- 2/a)
b) Supply& Fixing240 V,25A Modular starter (Brand approved by EIC) on existing GI Modular type switch board with top cover plate and making necessary connections with PVC Cu wire and earth continuity wire etc. (E-19 sl no- 20)
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S & F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2 x 1.5 sqmm flexible copper wire (C-3 sl no- 21/a)
Fixing only fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports including S & F EI conduit, ball socket/socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10 mt. length (C-2 sl no- 15)
Extra for suspension exceeding 25 cm with S & F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length (C-2 sl no- 16)
28. Fixing onlyexhaust fan aftermaking hole in wall and making good damages and smooth cement finish etc. as practicable aspossible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter 30cm(12") (C-4 sl no- 28/b)
Supply & Fixing louver shutter on wall with necessary Bolts & nuts (6mm dia x 62 mm long)
Supplying & Fixing bulk head light fitting (Havells make) with die cast aluminium housing & frosted glass on wall/ceiling incl. S&F 8 watt CFL / 100 watts GLS lamp complete set (D-13 sl no- 23)
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991) (D-14 sl no- 29)
a) Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, onexisting GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc (e-17 sl no- 4/c)
b) Supply & Fixing 240 V, 25A Modular switch type DPMCB (C-Curve) (Brand approved by EIC)on existing GI Modular type switch board with top cover plate and making necessary connections with PVC Cu wire and earth continuity wire etc (e-19 sl no- 19/b)
c) Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall including making earthing attachment, painting and mending good damages to building works 2 Row 12 Module (e-17 sl no- 1/e)
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts long and 1x 4 SWG GI (Hot Dip) wire (4 Mts. long) 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl S &F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts below the ground level as below By ISI-Medium GI pipe (G-1 sl no- 2/a)
a) Supplying& fixing earth busbar of galvanized (HotDip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts,nuts, washers, spacing insulators etc. as required (G-2 sl no- 4/a)
b) Connecting the equipments to earth busbar including S& F GI (Hot Dip) wireof size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages (No.10 SWG) (G-2 sl no- 5/iv)
Excavation of soil for installation of Earth Electrode and filling & ramming For Morrum Soil (G-1 sl no- 1/b)
Supply of 20 watt TRIMLINE is a robust and high performance batten. This LED luminair comprises of extruded channel in thermally conductive material. High translucent serrated milky white diffuser is used to get glare free and smooth light distribution. efficiency: 100 lumen/wall model LED-20-WW
Supply of 15 watt classy LED 3 star lamp model no. LHLDEUEEML8R015 (Approved analized rate annexure-II, sl no 6)
Labour welfare Cess
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.76 MB
BOQ_2405838.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid