Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹13.9 LAccepted-AOC 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | L-1 | Accepted-AOC Due to lowest and quoted reasonable rates | |
| 2 | L-2₹15.4 L+₹1.4 L (10.3%)Rejected-Finance AWANTA BHAWAN SOURA SRINAGAR 190011 J K | SRINAGAR | JAMMU AND KASHMIR | 190011 | L-2 | Rejected-Finance Higher side quoted amount | |
| 3 | L-3₹15.4 L+₹1.4 L (10.3%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L-3 | Rejected-Finance Higher side quoted amount |
Tender Value
Refer Docs
EMD Value
₹35,780
Closing Date
15 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Khumbathang
CWE Khumbathang
REPAIR/MAINT OF CENTRAL HEATING PLANT AND STAND ALONE CHS AT NIMU UNDER AGE(I)NIMU
2021_MES_468971_1
CWE/K-37/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
Nimu
As per tender and NIT doc
8 documents required · 8 mandatory
₹500
AGE(I)Nimu
₹35,780
23 Oct 2021
18 Aug 2021
17 Sept 2021
18 Aug 2021
15 Sept 2021
1 Sept 2021
90 days
Amount
Supply and fixing in replacement of duel shaft electric motor 30 watt 930 RPM, 3 speed as per existing for fan coil unit, complete all as specified and directed. Make- Maratan/CEG.
Supply and fixing in replacement of Old unsv radiator unit of FCU including connecting with the unit and making it leakproof of copper coils covered with aluminium finishing as per existing size of capacity 3000 K Cal / Hour complete all as specified and directed.
Supply and fixing in replacement of Old unsv radiator unit of FCU including connecting with the unit and making it leakproof of copper coils covered with aluminium finishing as per existing size of capacity 6000 K Cal / Hour complete all as specified and directed.
Material and labour for Dismantling of burner assembly at 25 Gnr Nimmu plant room CHS and removing of side cover and repairing the same by removing the old burnt fire refractory cement plastering, replastering the same as per existing fire refractory cement for boiler capacity 6 lakh Kcal/hr and complete servicing the boiler by removing the complete carbon/oil deposits with suitable coil shine chemical including repair to coil assembly by welding if there is any leakage found or any other repair required at site and reassembling/ testing the same, complete all as specified and directed.
All as per srl item No. 4 here-in-before but for 4 Lakh Kcal/Hr at 25 Gnr regt complete all as specified and directed.
M&L for dismantling for repair stand alone air heater for space heating of capacity 50000 Kcal/hour by unscrewing and removal of heater side/end plates, with scalent de-carbonizing, scraping out carbon, dirt acculated in heater, overhauling, servicing including re-assembling all the dismantal component to it's originol position with testing and commissioning, complete all as specified and as directed by Enginer-in-Charge.
M&L for dismantling for repair of the blower motor of stand alone air heater for space heating of capacity 50000 Kcal/hour including re-winding of blower motor with suitable size/gauge of copper winding wire including replacement of suitable blower fan sweep and blower fan guard and re-fixing of the same after varnishing, complete all as specified and as directed by Enginer-in-Charge.
Material and labour including taking down and Re fixing for rewinding of electric motor 3 phase 415 volts of capacity 7.5 HP with superior quality super enameled copper winding wire of appropriate size and gauge as existing including varnishing , cotton tape, PVC sleeves etc, complete all as specified and directed.
M&L for repair to the glycol pump and motor of capacity 7.5 HP, including replacement of bearings, oil seals or any other spares / work required for smooth functioining of pump, complete all as specified and directed. Note - Major items replaced shall be measured and paid separately under respective item of BoQ and fixing of part rate also included.
Supply only Ball Bearing of suitable size
Supply only Oil seal /Gland
Supply Only Air circulation Fan (Plastic)
Supply Only Impellers
Material and labour incl taking down and Re fixing for rewinding of electric motor single phase 230 volts of capacity 01 HP with superior quality super enameled copper winding wire of appropriate size and gauge as existing including varnishing , cotton tape, PVC sleeves etc, complete all as specified and directed.
M&L for repair to the glycol make up pump and motor of capacity 01 HP, 2870 RPM including replacement of bearings, oil seals or any other spares / work required for smooth functioining of pump, complete all as specified and directed. Note - Major items replaced shall be measured and paid for separately under respective item of BoQ and fixing of part rate also included..
Supply only Ball Bearing of suitable size
Supply only Oil seal /Gland
Supply Only Air circulation Fan (Plastic)
Supply Only Impellers
S&F in sequence controller suitable for 6 lakh kilo/hr LAL 2.25 burner rod assembly, complete all as specified and directed. Make- Siemens/L&T/Schnieder
S&F in sequence controller suitable for 4 lakh kilo/hr LAL 2.25 burner rod assembly, complete all as specified and directed .Make- Siemens/L&T/Schnieder
S&F in replacement of ignition rod suitable for 06 lakh Kcal/hr burner rod assembly as per sample complete all as specified and directed.
S&F in replacement of ignition rod suitable for 04 lakh Kcal/hr burner rod assembly as per sample, complete all as specified and directed.
S&F in replacement of ignition Transformer electronic type suitable for 6 lakh Kcal/hr burner rod assembly as per sample complete all as specified and directed.
S&F in replacement of ignition Transformer electronic type suitable for 4 lakh Kcal/hr burner rod assembly as per sample complete all as specified and directed.
S&F temprature controller digital type DTC 503 with sensor suitable for 6 lakh Kcal/hr LAL 2.25 burner rod assembly, complete all as specified and directed. Make- Siemens/L&T/Schnieder
S&F temprature controller digital type DTC 503 with sensor suitable for 4 lakh Kcal/hr LAL 2.25 burner rod assembly, complete all as specified and directed. Make- Siemens/L&T/Schnieder
S&F in replacement of pressure gauage 4" dial 0 to 10 Kg/Sqcm as per existing, complete all as directed by Engineer-in-Charge. Make :AE/IEBIG
S&F in replacement of digital type volt meter 0-500 volts, complete all as specified and directed. Make :AE/IEBIG
S&F in replacement of photo cell as per existing suitable for 6 lakh Kcal/hr burner rod assembly, complete all as specified and directed.
S&F in replacement of photo cell as per existing suitable for 4 lakh Kcal/hr burner rod assembly, complete all as specified and directed.
S&F in replacement of digital type Amp meter complete with suitable CTs 0-300 Amps, complete all as specified and directed. Make :AE/IEBIG
S&F in replacement of indicating lamps RYB as per existing complete all as specified and directed. Make :AE/IEBIG
S&F in replacement of rotary type ON/OFF switches, 22mm dia as per existing, complete all as specified and directed.
Cleaning of MS diesel storage tanks of capacity 1000 Ltrs by removing of sludge from tanks and scrapping the side walls by means of wire brush or emery paper and wash the same with caustic soda and clear water and painting the internal wall with two coats of black rubber emulsion paint and painting the complete tank from out side with two coats of synthetic enamel paint, complete all as specified and directed.
S&F in replacement of PVC flexible copper multistrand wire 3 core of 2.5 sqmm as per existing, complete all as specified and directed. Make: Polycab/Finolex/ Havells
S&F in replacement of burner nozzle suitable for 6 lakh K/Cal/Hr complete all as specified and directed.
S&F in replacement of burner nozzle suitable for 4 lakh K/Cal/Hr complete all as specified and directed.
S&F in replacement of Electrode suitable for burner of capacity 6 lakh K/Cal/Hr complete all as specified and directed.
S&F in replacement of Electrode suitable for burner of capacity 4 lakh K/Cal/Hr complete all as specified and directed.
S&F in replacement of DOL starter MK-1, 10 HP as per existing, complete all as specified and directed. Make: L&T/Bentex/Kirloskar
S&F in replacement of DOL starter MK-1, 7.5 HP as per existing, complete all as specified and directed. Make: L&T/Bentex/Kirloskar
S&F in replacement of High pressure fuel pipe 1.5 mtr length as per existing, complete all as specified and directed.
S&F in replacement of FCU connection flexible pipe 20/16 mm as per existing, complete all as specified and directed. Make- Jindal/Kitetac.
S&F in replacement insulation 13mm as per existing, complete all as specified and directed. Make-Caflese or equivalent from approved list.
S&F in replacement of plug top 15/5 Amps as per existing, complete all as specified and directed.Make : Anchor/Havells
S&F in replacement of gun metal butter fly control valves of 100 mm bore as per existing, complete all as specified and directed. Make: BIR/Kalinga
S&F in replacement of gun metal butter fly control valves of 80mm bore as per existing, complete all as specified and directed. Make: BIR/Kalinga
S&F in replacement of gun metal butter fly control valves of 40/50mm bore as per existing, complete all as specified and directed. Make: BIR/Kalinga
S&F in replacement of inlet outlet Ball valve 3/4" for FCU as per existing, including supply and fixing MS / GI nipple of size 3/4 inch includig welding work including cutting the existing rusty unserviceable MS/GI nipple complete all as specified and directed. Make: BIR/Kalinga
M&L for repair of exaust pipe of boiler by welding, complete all as specified and directed by Engr-in-Charge.
S&F for closed cell elastometric insulation 30 to 40 Kg/Cub mtr density 19 mm thick (nitrile insulation) complete all as specified and directed. Make- Eurobatex/ Superion/ Aeorflex.
S&F in replacement of auto air pressure valve 3/8" as per existing, complete all as specified and directed. Make: BIR/Kalinga
Supply and filling of Mono Ethylene Glycol (MEG) of 99% purity and having freezing temperature less than -40° in Central heating plant installed at 6 Sikh Nimmu all as specified and direced by Engineer-In- Charge. Make;- India Glycol Ltd or equivalent from approved list.
Supply and laying, connecting , fixing in repair/replacement including taking out the existing pipe and testing of MS ERW 'C' class piping 65 mm bore pipe, complete with fittings, duly insulated with 13mm thick closed cell elastomeric insulation 30 to 40 Kg/m3 density for the hot Glycol fluid pipes.(Note:-The pipes shall be provided with 24 SWG aluminium cladding over the insulation for exposed piping only and underground pipe shall be till 1.5m in depth)
All as per srl item No.48 here-in-before but 50 mm bore pipe with 13mm thick nitrile insulation.
All as per srl item No.48 here-in-before but 40 mm bore pipe with 13mm thick nitrile insulation.
All as per srl item No.48 here-in-before but 32 mm bore pipe with 13mm thick nitrile insulation.
All as per srl item No.48 here-in-before but 25 mm bore pipe with 13mm thick nitrile insulation.
All as per srl item No.48 here-in-before but 20 mm bore pipe with 13mm thick nitrile insulation.
M&L for replacement of MS pipes 80mm bore, heavy grade in any length laid in tranches pressure testing, welding of pipe, washing out complete including dismantling, taking out old corroded pipe line including all fittings complete all as specified and as directed by Engineer-in-Charge
All as per srl item No.49 here-in-before but 100mm bore pipe
All as per srl item No.49 here-in-before but 150mm bore pipe
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth; for laying of pipe & getting out of hard/dense soil complete all as specified and directed
Removal of excavated soil to distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed
Returning filling in including spreading, levelling, watering and well remming in layers not exceeding 25cm thick in hard/dense soil complete all as specified.
Note:-The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 35,020.00 and any other reduction if any from quoted amount.
EVERGREEN GROUP OF INDUSTRIES
national engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .