Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.4 LAccepted-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹9.5 L+₹88,175 (10.2%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹12.5 L+₹3.9 L (45.7%)Rejected-Finance | L3 | Rejected-Finance Being L3 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
8 Feb 2020, 6:00 pmClosed
GE (South) Patiala
MILITARY ENGINEER SERVICES GARRISON ENGINEER SOUTH TARAPORE ENCLAVE PATIALA CANTT
As per tender document
2020_MES_316730_1
GE(S)/PAT-50/S/2019-20
Open Tender
Civil Works
Item Rate
150 days
Mil Stn Sangrur
Refer tender document
6 documents required · 6 mandatory
₹500
Yes
GE South Patiala
₹30,000
Yes
6 Mar 2020
20 Jan 2020
10 Feb 2020
20 Jan 2020
8 Feb 2020
27 Jan 2020
20 Jan 2020 - 25 Jan 2020
Amount
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete with fittings and fixtures such as switches, ceiling roses, pendants, regulators, socket, lamp holders brackets, bulk head fittings etc removing material for taking credit ( credit shall be recovered as per credit Sch attached) and also making good disturbed surfaces of wall, floors etc complete all as specified and directed.
M&L for point wiring with 1.50 sqmm in copper conductor cable ( multistrand) FRLS single core PVC insulated cable in and including PVC concealed conduit ( ISI Marked) of heavy duly with all accessories ie PVC gutties etc terminated in sunken/pressed metal flush box and continuous earth wire 1.5 Sqmm copper cable PVC insulated FRLS controlled by one switch for one light/fan/sockets point/ complete all as specified and directed. in ceiling Portion surface conduit wiring to be done. Note : i) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost ii) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth.
All as per item No 2 above, but for one 3/5 pin socket outlet 5 Amp on the same board with other switches complete all as specified and as directed by the Engineer-in-Charge.
All as per item No 2 above, but for one 3/5 pin socket outlet 5 Amp on independent board complete all as specified and as directed by the Engineer-in-Charge.
All as per serial item No 2 here-in-before , but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor ( Multi-stranded) PVC insulated and unsheating electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 2.5 Sqmm copper stranded conductor as continuous earth wire connected to common earth dolly complete all as specified and as directed by Engineer-in-Charge.
M&L for Modular Socket 6A/16A - 2/3 pin combined 2 module type all as specified and directed.
M&L for Modular Socket, 6A - 2/3 pin combined 2 module type all as specified and directed.
M&L for Modular switch 1 way 6A, 1 module type all as specified and directed.
M&L for Modular switch 1 way 16A, 1 module type all as specified and directed.
Material and labour for Modular Bell push 6A 1 module complete all as specified and directed.
M & L for Fan step regulator, 120W -AC 230 Volt Modular type all as specified and directed.
Material and labour for ceiling rose surface type, 65 mm x 50 mm two to three terminals / PVC / polycarbonate, isolated body fixed on PVC block complete all specified and as directed by the Engineer-in-Charge.
Supply and fixing for sub main wiring two single core PVC insulated and unsheathed cable with 6 Sqmm multi -strand copper conductor drawing in PVC concealed conduit with 6 Sqmm PVC copper conductor cable as in earth wire system ,including taking out old wiring, complete all as specified and directed.
M&L for Sub main wiring in PVC concealed conduit with 2 Nos single core PVC insulated copper conductor cable flame proof size 4 sqmm multistrand and 4 sqmm PVC insulated flame proof earth wire using suitable size of copper thimble all as directed.
Supply & fix in replacement of existing unserviceable Sheet metal enclosure with new DB’s suitable for MCBs of single pole and neutral 8 way double door type with 200 amp rated bus bar. Note: i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. ii) The disturbed surface shall be match with existing shall be part of job, complete all as specified and directed.
Supply and fix in replacement of MCB SP up to 6-32 Amp all as specified and directed.
Supply and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, one twin core cable flat or circular stranded conductor size of 10 Sqmm, 2 core, complete all as specified and directed.
Supply and fix in replacement of MCB SPN 6-32 Amp complete all as specified and directed.
Supply & fix in replacement of existing unserviceable FTL with new techonlgy ultra bright led tubelight with aluminium heat sink & polycarbonate diffuser having high efficacy suited for installation in existing t5 tubelight with G5 lamp holders to give glare free light with separate led driver of capacity 18W 865 1148mm LED including neccessary electric conection with batten .
Supply & fix in replacement of existing unserviceable batten with BOX TYPE Pre-coated CRCA body, heavy duty regaL Batten for LED tube universal batten for G13 t8 lamps including neccesary fitting on wall and making electric connection from ceiling rose to connector with suitable size of electric cable and making good the disturbed surface.
Supply & fix in replacement of existing unserviceable mirror light with Linear & compact 9W mirror light with decorative grey end caps, polycarbonate body and ribbed opal diffuser of capacity 9 watt Model:EDGE Lite or of equivalent make as specified in Appx 'B', complete all as specified and directed.
Material and labour for angular type lamp holder, PVC/ polycarbonate type with back plate suitable for 15/18 watts for batten fitting, including plastic square board of required size, complete all as specified and directed.
Supply and fix LED Lamp LED new Adore 7W E27 WW Ball Lamp LHLDERHEMD 8X007 7 watt all as per specified and directed.
Material and labour for call bell ding dong AC 230 volt single pole complete all as specified and directed.
Taking down ceiling fan of any type and refixing on the location as directed after cleaning, oiling, overhauling, greasing, replacement of rubber bush, quarter pin etc. including connection with three core flexible PVC conductor cable of size 23/0.0076, complete all as specified and directed.
S&F in replacement of existing unserviceable LED building light IP 66 powder coated pressure die cast aluminium compact high power LED fitting 25 watts with heat resistant toughned glass complete with all accessoreis watts complete including GI pipe bracket made out 40 mm dia GI pipe medium grade of 1.20 mtr long and make to shape fixing with 40x6mm size of flat iron clamp, nuts , bolts and washers connection including two coat of aluminium paint over a coat of primer and fixing the fitting on bracket and all the electrical connection, complete all as specified and directed.
M&L in replacement of earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth wire 4mm dia by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) including iron angle frme 40*40*6mm. and medium grade GI watering pipe 20mm dia with funnel and wire mesh and 15 mm bore GI pipe light grade protection pipe including excavation and charcoal ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I, complete all as specified and directed.
Supply & fix in replacement of existing unserviceable Sheet metal enclosure with DB’s suitable for MCBs of triple pole and neutral 4 way, 415 volt, double door type with 200 amp rated bus bar double door type with one incoming and 12 outgoing Note: i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. ii) The disturbed surface shall be match with existing shall be part of job, complete all as specified and directed.
Supply and fix in replacement of MCB TPN 63 Amp complete all as specified and directed.
Supply & fixing modular white cover plate with frame for fixing of modular switches for 12 module, complete all as specified and directed.
All as per Serial item no 30 but of 8 module complete all as specified.
All as per Serial item no 30 but of 3 module complete all as specified.
All as per Serial item no 30 but of 1 module complete all as specified.
S& F blank spacer plate for single module, complete all as specified and directed.
Supply and replace existing unserviceable SP&N enclosure with 2 pole and Earth Metal Plug & Socket for incorporating 10A / 20A SPN / DP MCB With Plastic Coverearth complete with one single pole MCB of 20 Amp complete all as specified and directed.
Supply and replace environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge-lit led luminaire comprising of high brightness leds of capacity10 Watt complete all as specified and directed.
m/s narinder kumar sons
M/s Pawan Kumar Goyal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .