Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹1.9 Cr
EMD Value
₹1.9 L
Closing Date
31 Oct 2024, 5:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Facilities Management Division, Bangalore
HINDUSTAN AERONAUTICS LIMITED Facilities Management Division, Bangalore
Construction of Balance Works for GHE GSE Shed and Receiving Store at Helicopter Division, HAL HC.
17299
TENDER NOTICE/NCP/35/24-25/02
Works
Contract Section Civil-FMD-Bangalore
₹2,360
₹1.9 L
31 Oct 2024
17 Oct 2024
17 Oct 2024
31 Oct 2024
Name of the Individual / Firm / Company: * Mandatory
Type of ownership
Year of Estblishment of Company/Business
If Other, please specify
Details of Constitution or Legal Status such as certificate of incorporation, shops and establishments, etc.,
Address for correspondence:
TIN number
PAN no and Name of Holder
PF number (If any)
ESI number
Service Tax Registration No
Goods and Service Tax ID No.
SAC Code
Contact details
Registered Contractor
Pls Enter
Need to Fill Column 19
Maximum value of works excuted during the followinf 5 years. . (In Lakhs)
Pls enter Finiancial Turnover in Rupees for all the years
DETAIL OF WORK ON HAND UPTO N-Months (N-contract period) [For Bid capacity calculation] NOTE : PROVISION for 10 works are given. If more, a separate similar sheet to be made showing all the works with all details as per this FORMAT and same to Uploaded. However, 9 works details to be provided and balance work value of other works to be added and to be provided in 10th row as OTHER works.
Name of Organization with address
Balance Work On Hand
Work Schedule for completion of works with in stipulated time [Please enclose action plan / bar chart as to indicate the completion of work, within the scheduled time (contract period)]
Quantity of work Excuted during the last three years
Bank(s) details: [Copy of the cheque leaf to be uploaded]
Bank Account No.
Bank Statement for past three month
Latest Over draft Facilties with Bank enter Name of Bank, Date of Issue and Value of Over Draft
Latest Bankers Solvency Certificate from Nationalized/ scheduled Bank issued NOT before 12 months from the date of Tender Notice.
#VALUE!
Experience of having successfully completed similar works during last 7 years ending last day of previous month. [Work experience certificates / Completion certificates should be uploaded for verification]. [Latest work experience certificate may be uploaded] (i) THREE similar completed works each costing not less than the amount equal to 40% of the estimated cost. (ii) TWO similar completed works each costing not less than the amount equal to 50% of the estimated cost. (iii) ONE similar completed work each costing not less than the amount equal to 80% of the estimated cost. [Amount put to the Tender]
You are Not Eligible
Type of Work [ Incase of private works the same shall be supported with TDS certificate]
Type of Work [ Incase of private works the same shall be supported with TDS certificate]
work done
Type of Work and Organisation name [ Incase of private works the same shall be supported with TDS certificate]
#VALUE!
Related Document to be Uploaded to eProcurement Portal
DEAILS OF TECHNICAL PERSONNEL AVAILABLE( if space provided is insufficant separate sheet to be uploaded with the same format as below)
Name of members or technical personllel avalable in the organization
DETAILS OF MACHINERY AVAILABLE
Name of Mechinery
Concrete Mixers - Type etc
Vibrators - Diesel - Electrical
Weiding equipment's
a) Rectifiers
b) Welding Generators
Erection equipment's
Cranes-
Hoists-
Lifts-
Water Lifting motor pumps
a) Diesel
b) electric
Drilling Equipment's
Compressors
Trucks
Stone crushers
Bitumen hot mixture plant
Bitume boiler
Rollers
Batching plants
Vibratory rollers
Generators
Cranes-Details
Concrete pumps
Road Pavers
Rock breakers
Transit mixers
Excavators
Weight batches
Others
Details of person holding the power of Attorney (If different from contact person)
Related Document to be Uploaded to eProcurement Portal
DECLARATION
Pls enter
Tender Document Cost and EMD details
Enclosed / Not enclosed
Enclosed
Enclosed
Average annual financial turn over during the last 3 years, ending 31st March 2023 [ should not be less than 30% of amount put to tender] and details for last 5 years to be provided to assess the bid capacity. The values provided to be supported by uploading Balance Sheet along with Profit & loss account statement. . (In Lakhs)
Specification
Earthwork excavation over areas not exceeding 1.5 m deep in all kinds of soft / hard soil for foundations, footings, column pedestals etc., and getting out including clearing away all grass, vegetation, saplings, shrubs, undergrowth, roots and trees not exceeding 30 cm girth, shoring, strutting for protecting the sides of foundation if required, removing slips or falls in excavation, forming steps in sides of deep excavations and their removal or covering up, pumping, bailing out of water so as to keep foundations in dry condition at any stage of work and draining water away from the site of work without any extra payment, levelling, ramming the bottom of excavation, stacking useful materials as directed and disposing unwanted materials outside the site area to a distance not exceeding 50 m, with all labour, tools & tackles, plant & machinery, hire & fuel charges etc., all complete as per drawings and as directed by the Engineer-in-Charge.
Earthwork excavation over areas exceeding 1.5 m but not exceeding 3.0 m deep in all kinds of soft / hard soil for foundations, footings, column pedestals etc., and getting out including clearing away all grass, vegetation, saplings, shrubs, undergrowth, roots and trees not exceeding 30 cm girth, shoring, strutting for protecting the sides of foundation if required, removing slips or falls in excavation, forming steps in sides of deep excavations and their removal or covering up, pumping, bailing out of water so as to keep foundations in dry condition at any stage of work and draining water away from the site of work without any extra payment, levelling, ramming the bottom of excavation, stacking useful materials as directed and disposing unwanted materials outside the site area to a distance not exceeding 50 m, with all labour, tools & tackles, plant & machinery, hire & fuel charges etc., all complete as per drawings and as directed by the Engineer-in-Charge.
Earthwork excavation in trenches for foundations, pipes, cables, drains etc. not exceeding 1.5 m in width and excavation for manholes, shafts, pits, wells and the like not exceeding 10 m² in plan upto 1.5 m deep in all kinds of soft / hard soil and getting out including clearing away all grass, vegetation, saplings, shrubs, undergrowth, roots and trees not exceeding 30 cm girth, shoring, strutting for protecting the sides of foundation if required, removing slips or falls in excavation, forming steps in sides of deep excavations and their removal or covering up, pumping, bailing out of water so as to keep foundations in dry condition at any stage of work and draining water away from the site of work without any extra payment, levelling, ramming the bottom of excavation, stacking useful materials as directed and disposing unwanted materials outside the site area to a distance not exceeding 50 m, with all labour, tools & tackles, plant & machinery, hire & fuel charges etc., all complete as per drawings and as directed by the Engineer-in-Charge.
Earthwork excavation in trenches for foundations, pipes, cables, drains etc. not exceeding 1.5 m in width and excavation for manholes, shafts, pits, wells and the like not exceeding 10 m² in plan exceeding 1.5 m and not exceeding 3 m deep in all kinds of soft / hard soil and getting out including clearing away all grass, vegetation, saplings, shrubs, undergrowth, roots and trees not exceeding 30 cm girth, shoring, strutting for protecting the sides of foundation if required, removing slips or falls in excavation, forming steps in sides of deep excavations and their removal or covering up, pumping, bailing out of water so as to keep foundations in dry condition at any stage of work and draining water away from the site of work without any extra payment, levelling, ramming the bottom of excavation, stacking useful materials as directed and disposing unwanted materials outside the site area to a distance not exceeding 50 m, with all labour, tools & tackles, plant & machinery, hire & fuel charges etc., all complete as per drawings and as directed by the Engineer-in-Charge.
Returning / refilling with useful excavated soil, free from salts, organic or other deleterious matter in foundations, trenches, footings etc. (Other than black cotton soil & rock etc.), spreading in layers not exceeding 25 cm thick, watering, breaking / removing clods exceeding 50 mm, ramming and consolidation etc., with all labour, tools & tackles, plant & machinery, etc., all complete as directed by the Engineer-in-Charge.
Removing / transporting the surplus excavated earth including debris, vegetation waste etc., to a distance not exceeding 1500 m including loading, unloading, depositing, spreading, levelling etc., after obtaining due clearance from the Engineer-in-Charge etc., all complete as directed by the Engineer-in-Charge.
Providing anti-termite treatment with bifenthrin emulsifiable concentrate chemical mixture prepared and applied in multiple stages as specified below as per M.E.S. S.S.R. 2010, all complete as directed by the Engineer-in-Charge. However execution shall be as per IS 6313 (Part 2). Note: A performance guarentee bond for 10 years on non judicial stamp paper of Rs. 500/- shall be given by the contractor. 10% of completed value of this item shall be deducted as defect liability deposit and the same shall be returned after successful completion of 10 years from the date of completion of the contract / project as a whole.
For plinth protection at 5 litres of chemical emulsion per m² of surface area
Along external perimeter of the building using chemical emulsion at 7.5 litres per m² of vertical surface of perimeter of the external wall to a depth of 300 mm including rodding etc.
Supplying and placing to required depth graded boulders 80 mm to 150 mm, free from dust and debris in prepared pits etc., all complete as directed by the Engineer-in-Charge.
Supplying and placing to required depth graded coarse aggregate / gravel 40 mm and down size, free from dust and debris in prepared pits etc., all complete as directed by the Engineer-in-Charge.
Supplying and placing to required depth graded coarse aggregate / gravel 20 mm and down size, free from dust and debris in prepared pits etc., all complete as directed by the Engineer-in-Charge.
Supplying, mixing and placing plain cement concrete (1:4:8) of required thickness using 40 mm and down graded hard stone/granite aggregate in accordance with IS 456 in foundations, mass concrete, sub bases, floors, pavings and other similar works including formwork, mechanical mixing, transporting, vibrating, consolidation, levelling, curing, dewatering if any, all materials, labour, lead & lift, tools, plant & machinery, keeping concrete well wetted during the curing period and protecting it in extreme weather conditions etc., all complete as directed by the Engineer-in-Charge.
Supplying, mixing and placing plain cement concrete (1:2:4) with 20 mm and down graded aggregates in copings, cills, string courses, hold fasts for doors and the like at all levels including necessary formwork, weathering, rounding or chamfering and throating, mixing, transporting, consolidation, levelling, curing, all materials, labour, lead & lift, tools, plant & machinery, keeping concrete well wetted during the curing period and protecting it in extreme weather conditions etc., all complete as directed by the Engineer-in-Charge.
Supplying and fixing precast reinforced cement concrete cover slabs of required size as per design & drawings in cement concrete (1:2:4) using 20 mm and down graded aggregates, set in cement mortar (1:4) including necessary formwork, finishing all exposed surfaces uniformly even & smooth, making necessary weep / drain holes, mixing, transporting and placing, consolidation, levelling, curing, all materials, labour, lead & lift, tools, plant & machinery, keeping concrete well wetted during the curing period and protecting it in extreme weather conditions etc., all complete as directed by the Engineer-in-Charge. Note: Reinforcement shall be paid separately.
Supplying, mixing and placing in position, controlled grade reinforced cement concrete M 25 with 20 mm and down graded granite aggregate at all levels for the sub items mentioned below including transporting, consolidation, levelling, curing, scaffolding, all materials, labour, lead & lift, tools, plant & machinery, keeping concrete well wetted during the curing period and protecting it in extreme weather conditions, hacking the surface to secure plastering where required, aligning and placing in position foundation bolts as per drawing etc., all complete as directed by the Engineer-in-Charge. Note: (i) Reinforcement & formwork shall be paid separately. (ii) If day concrete exceeds more than 6 m³, ready mix cement concrete shall be used. (iii) All RCC works to be carried out by using OPC 43 grade cement. (iv) Mix design to be obtained from Govt. / NABL laboratory for site batching concrete. (v) RMC shall be from approved manufacturer having minimum cement content as per IS 456 and the same shall be approved by HAL before execution.
All works up to plinth level including necessary openings and packing if any for laying pipes, cables etc.
All work above plinth at all levels including necessary openings and packing if any for laying pipes, cables etc.
Supplying and mixing integrated water proofing compound conforming to IS 2645 in cement concrete/cement plaster works in proportions as specified by the manufacturer's specification etc., all complete as directed by the Engineer-in-Charge.
Blockwork with 200 mm thick precast cement concrete solid blocks conforming to IS 2185 (Part 1) having minimum average compressive strength of 4 N/mm² and density not less than 1800 kg/m³ built in cement mortar 1:6 (1 cement : 6 coarse sand) for walls at all levels including necessary formwork, curing, finishing, making or leaving holes & chases and making good etc., all complete as directed by the Engineer-in-Charge.
Blockwork with 100 mm thick precast cement concrete solid blocks conforming to IS 2185 (Part 1) having minimum average compressive strength of 4 N/mm² and density not less than 1800 kg/m³ built in cement mortar 1:4 (1 cement : 4 coarse sand) for walls at all levels including necessary formwork, curing, finishing, making or leaving holes & chases and making good etc., all complete as directed by the Engineer-in-Charge.
Brick work with sewer bricks having average compressive strength not less than 75 kg/cm² built in cement mortar (1:4) for rain water pits, soakwell etc. at all levels, including making or leaving holes & chases, raking out joints 10 mm deep, scaffolding, curing etc. with all materials, labour, tools and tackles etc., all complete as directed by the Engineer-in-Charge.
Construction of size stone masonry in cement mortar (1:6) for walls, ramps, foundations, basements etc. at all levels, in courses not less than 15 cm high with bond stones at 1.4 to 1.8 m apart in each course, solidly hearted faces, beds and joints squared back, raking out joints 10 mm deep, curing, providing weep holes if any etc., all complete as directed by the Engineer-in-Charge.
Providing flush pointing in cement mortar (1:4) to squared rubble, coursed or uncoursed stone masonary etc., all complete as directed by the Engineer-in-Charge
Formwork by providing timber, wooden planks, runners / M.S. sheets with all supports, struts, braces, wedges, scaffolds, bracings, ladders, gangways, dressing with oil including M.S. bolts nuts and washers, temporary openings, filleting for a stop, chamfered edges, internal / external splayed, rounded angles or grooves for forming throating including making temporary openings in the forms for pouring concrete etc., all complete as directed by the Engineer-in-Charge for the sub-items mentioned below. Note : Formwork material is contractor's own property and shall be removed after completion of work.
For foundations including rafts, footings, foundation beams, plinth beams, pedestals etc.
For slabs, landings, balconies, canopies, deck slabs, shelves and the like in fair finish
For lintels, beams, tie beams, cantilevers, bressummers etc.
For columns, pillars, brackets, piers, posts, struts etc.
Supplying, fabricating and fixing second class hard wooden plain, solid, straight chowkats and frames, wrought framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints and fixed to wall etc., all complete as directed by the Engineer-in-Charge.
Supplying, fabricating and fixing in position 40 mm thick flush shutter conforming to IS 2202 (Part I), block board solid core type with plywood face panels commercial type on both sides, including provision of internal wood lipping, rebates, suitable blocks for taking mortice locks, latches or other fittings, fitting to frames/chowkats etc., all complete as directed by the Engineer-in-Charge. Note: Fittings / hardware shall be paid separately.
Supplying and fixing fiber glass reinforced plastic (FRP) door frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminte shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame., all complete as directed by the Engineer-in-Charge.
Supplying and fixing 30 mm thick glass fibre reinforced plastic (FRP) panelled door shutter of approved make to door frames, made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS 14856, all complete as directed by the Engineer-in-Charge.
Supplying and fixing the following fittings / hardware of approved make and design to door with all required screws, bolts, nuts, washers etc., all complete as directed by the Engineer-in-Charge.
Polished brass barrel tower bolts 300 mm long with barrel of extruded sections of brass and rolled or drawn brass bolt
Polished brass barrel tower bolts 200 mm long with barrel of extruded sections of brass and rolled or drawn brass bolt
Brass sliding door bolt (Aldrop) 200 mm long with sand or die-cast brass hasp, staple (Bolt type) and rolled or drawn brass bolts
Extruded brass butt hinges 125 mm long with brass hinge pin, bright polished
Polished extruded brass handles fabricated type 150 mm long
Brass mortice lock (Vertical type) 100 mm size with min. 4 levers and finished bright
Floor door stopper of brass body and tongue with hard drawn steel spring, overall length of cover plate 150 mm
Mild steel hold fasts
Designing, fabricating, fixing and commissioning in position industrial sliding door / MS sliding door with motorization and option for manual operation of approved make. The sliding door shall be provided with two shutters or more as per site requirements / bi-parting made up of galvalume sheet on both sides not less than 0.5 mm thick including framework with M.S. structural members. The shutters shall be provided with view window of size not less than (0.5 x 0.5) m and side hung wicket door of (0.9 x 2.1) m in one shutter. The sliding door to be completed with all fittings and fixtures, locking facility, suitable motorization, guiding sections, rollers, rails, bearings etc. all complete and including painting with two coats of epoxy paint over a coat of approved primer, preparation of surface etc., all complete as per specifications and as directed by Engineer-in-charge.
Supplying, fabricating and fixing powder coated aluminium glazed three track sliding windows (Min. thickness of powder coating 50 microns) made up of aluminium extruded sections conforming to designaton 63400 of IS 1285 and of approved make comprising of the following: a) Top, bottom and lock side sections of the shutter shall not be less than (39.4 x 17.7 x 1.2) mm and weighing not less than 0.43 kg/m. b) Interlock side section of the shutter shall not be less than (39.4 x 17.7 x 1.2) mm and weighing not less than 0.51 kg/m. c) Top and side sections of the frame shall not be less than (91.8 x 31.75 x 1.5) mm and weighing not less than 0.98 kg/m to accomodate the shutter section. d) Bottom section of the frame shall be with gutter and not less than (91.8 x 45.5 to 37.5 x 1.5) mm and weighing not less than 1.57 kg/m. e) Shutters are to be provided with minimum 5 mm thick plain glass conforming to IS 2835 for two shutters and stainless steel fly proof mesh for one shutter fixed with good quality tapered aluminium interlocking screwless snap on type glazing clip not less than 0.9 mm thick. The rate is inclusive of all necessary fittings / hardware like touch lock, EPDM gasket, rollers, handle etc., with any additional aluminium members if required to carry out the work as per specification etc., all complete as directed by the Engineer-in-Charge. Note: The quoted rate shall be for the entire work and nothing extra shall be paid on this account.
Supplying, fabricating and fixing powder coated aluminium louvered ventilator (Min. thickness of powder coating 50 microns) made up of aluminium extruded sections conforming to designaton 63400 of IS 1285 and of approved make, with frame of size not less than (63.50 x 38.10 x 1.70) mm, weighing not less than 0.9 kg/m and min. 5 mm thick frosted/obscured glass strips fixed on 'U' channels with all necessary fittings and accessories etc., all complete as directed by the Engineer-in-Charge. Note: The quoted rate shall be for the entire work and nothing extra shall be paid on this account.
Supplying, straightening, fabricating and fixing steel reinforcement of HYSD TMT bars of not less than Fe 500 conforming to IS 1786 for all concrete reinforcment members / works including cutting to length, bending to shape required, including cranking, bending spirally for hooping for column, hooking ends and binding with mild steel wire (Annealed) not less than 0.9 mm dia or securing with clips, including fixing and bracing, wastage, welding, supporting or otherwise holding firmly in position so that the placing and ramming of concrete will not displace it etc., complete all as per specifications, drawings and as directed by the Engineer-in-Charge. Note: Only authorized laps, chairs etc. shall be considered for measurement.
Straightening, fabricating and fixing steel reinforcement of HYSD TMT bars of not less than Fe 500 conforming to IS 1786 for all concrete reinforcment members / works including cutting to length, bending to shape required, including cranking, bending spirally for hooping for column, hooking ends and binding with mild steel wire (Annealed) not less than 0.9 mm dia or securing with clips, including fixing and bracing, wastage, welding, supporting or otherwise holding firmly in position so that the placing and ramming of concrete will not displace it etc., complete all as per specifications, drawings and as directed by the Engineer-in-Charge. Note: Only authorized laps, chairs etc. shall be considered for measurement.
Supplying, fabricating and fixing in position M.S. framed work such as grills, gratings, ladders, railings etc., with ends of bars shouldered and/or riveted, welded etc., of approved design using standard sections, including necessary cutting, welding, embedding in concrete, masonry etc., all complete as directed by the Engineer-in-Charge.
Supplying, fabricating, hoisting and fixing in position M.S. structual steel work E 250 (Fe 410W) in girders, stanchions, purlins, bracings, crane gantries, rails, edging angles, frames, fastenings etc. using standard steel rolled sections, including M.S. plates, foundation bolts, cutting to dead length where required, notching, drilling, riveting and/or welding, connecting with bolts and nuts, wedging, plumbing, truing up and painting the members with two coats of synthetic enamel paint over a coat of approved zinc chromate primer, preparation of surface etc., all complete as directed by the Engineer-in-Charge.
Supplying and spreading granular sub base (GSB) of specified thickness with closely graded granite aggregate in mechanical mixtures at OMC, spreading in layers and compacting with power rollers / vibromax including watering etc. The quoted rate shall include preparation of surface by removing caked mud, brushing etc., finishing, watering, rolling, ramming in inaccessible areas etc., with all necessary materials, labour, tools and tackels, plants, etc., all complete as per specifications and as directed by the Engineer-in-Charge.
Supplying, mixing, laying 25 mm thick plain cement concrete (1:2:4), using 12.5 mm and down graded granite aggregates in drains, channels, trenches etc., including consolidation, necessary formwork, curing, materials, labours, tools and tackels, plants etc., all complete as per specifications and as directed by the Engineer-in-Charge.
Supplying, mixing and placing M25 controlled graded reinforced cement concrete of specified thickness for flooring, ramps, roads etc. with 20 mm gga metal including consolidation, curing, preparing surface to receive further layers, forming joints of any kind etc., all complete as directed by the Engineer-in-Charge. Note: (i) Reinforcement shall be paid separately. (ii) If day concrete exceeds more than 6 m³, ready mix cement concrete shall be used. (iii) Mix design to be obtained from Govt. / NABL laboratory for site batching concrete. (iv) RMC shall be from approved manufacturer having minimum cement content as per IS 456 and the same shall be approved by HAL before execution.
Supplying and filling grooves / joints in concrete floors of around (6 x 30) mm using two part elastomeric polysulphide sealant of pouring grade conforming to BS 4254 & IS 12118 (Part I) having a movement accomodation factor of min. ±25% and of approved make including preparation of surface, fixing of backer rod, fixing & peeling of masking tape, application of compatible primer etc., all complete as directed by the Engineer-in-Charge.
Supplying, mixing, laying 100 mm thick flagging concrete using cement concrete (1:3:6) with 20 mm down graded granite aggregate over boulder soling of 100 mm thick interstices filled with manufactured sand, well ramming to consolidate and laid with necessary slope, including curing and finishing with 12 mm thick cement mortar (1:3) on top and exposed sides, making grooves at every 1 m interval with necessary formwork etc., all complete as directed by the Engineer-in-Charge.
Supplying and laying glazed ceramic tiles of approved colour & pattern conforming to IS 15622, min. 7 mm thick (Square / rectangular), size approximately 300 x 450 mm or any suitable near by size, for vertical surfaces, with matching highlighter and border tiles, set & jointed in neat cement slurry at 3 kg/m² and pointed in white or coloured cement to match the colour of tile, over a screed of cement mortar (1:3) 10 mm thick including roughening the surface, machine cutting, curing etc., all complete as directed by the Engineer-in-Charge. Note: Quoted rate shall be inclusive of screed, pointing etc.
Supplying & fixing anti-skid ceramic tiles of approved colour & pattern conforming to IS 15622, min. 7 mm thick (Square / rectangular), area of each tile exceeding 0.06 m² but not exceeding 0.11 m², in floors, set & jointed in neat cement slurry at 3 kg/m² and pointed in white or coloured cement to match the colour of tile, over a screed of cement mortar (1:4) 20 mm thick including machine cutting, curing etc., all complete as directed by the Engineer-in-Charge. Note: Quoted rate shall be inclusive of screed, pointing etc.
Providing, applying and laying cement mortar (1:6) plastering 15 mm thick on brick/concrete surfaces, finished even and smooth with trowel for internal walls etc., with necesary materials, labour, scaffolding, curing, tools and tackles etc., at all heights, all complete as directed by the Engineer-in-Charge.
Providing, applying and laying cement mortar (1:4) plastering 15 mm thick mixed with water proofing compound (200 ml per 50 kg of cement or as per manufacturer's specifications) on brick/concrete surfaces, finished even and smooth with trowel for RWH pits etc., including necesary materials, labour, scaffolding, curing, tools and tackles etc., at all heights, all complete as directed by the Engineer-in-Charge. Note: Water proofing compound shall be paid separately.
Providing, applying and laying 20 mm thick water proof cement plaster work in two coats for external areas as directed. First coat 12 mm thick in cement mortar (1:6) made rough to recieve top coat, second coat 8 mm thick in cement mortar (1:4) mixed with water proofing compound (200 ml per 50 kg of cement or as per manufacturer's specifications), final surface finished with a floating coat of neat cement after necessary preparation of surface, at all levels with necesary materials, labour, scaffoldings, curing, tools and tackles, plants etc., threading if any as directed, all complete as directed by the Engineer-in-Charge. Note: Water proofing compound shall be paid separately.
Supplying and fixing galvanized steel hexagonal chicken mesh min. 150 mm wide having opening 20 mm x 20 mm and min. 0.91 mm dia at junctions of concrete & brick work or between different material, with necesary materials, labour, scaffolding, curing, tools and tackles etc., at all heights, all complete as directed by Engineer-in-charge.
Painting newly plastered interior surfaces with two coats of low VOC premium plastic emulsion with acrylic base conforming to IS 15489, of approved make, colour, shade, tint & pattern at all levels, over a coat of approved alkali resistant primer including preparing the surface by removing loose dirt and any organic growth, smoothening the surface by using suitable emery paper, filling crevices and finishing even by applying one full coat of putty, necessary scaffolding etc., all complete as directed by the Engineer-in-Charge.
Painting newly plastered external surfaces with two coats of low VOC premium weather proof exterior acrylic emulsion paint of approved make, colour, shade, tint & pattern at all levels, over a coat of approved acrylic primer including preparing the surface by removing loose dirt and any organic growth, filling of cracks with white cement putty or Plaster of Paris, necessary scaffolding etc., all complete as directed by the Engineer-in-Charge. Note: The paint shall have anti-algal, anti-fungal, UV resistant & anti-tarnishing qualities with 100% acrylic base and silicon or elastomeric additives.
Painting steel surfaces of any description with two coats of synthetic enamel paint conforming to IS 2932, of approved colour and manufacture over a coat of zinc chromate primer including preparation of surface by wire brushing/sand papering and wiping the surface clean with mineral solvents to remove grease and hard marks etc., applying metal paste for steel surface before painting the first coat etc., all complete as directed by the Engineer-in-Charge. Top coat of desired shade shall be applied after the undercoat has thoroughly dried and rubbed with fine grade of abrasive paper to ensure smooth and even surface, free from brush marks etc.
Painting wooden surfaces of any description with two coats of synthetic enamel paint conforming to IS 2932, of approved colour and manufacture over a coat of approved primer including preparation of surface by rubbing with fine grade of abrasive paper to ensure smooth and even surface, applying knifing paste filler putty before painting the first coat etc., all complete as directed by the Engineer-in-Charge.
Demolition of cement concrete of any description in ground floors and pavings, breaking to pieces of any thickness or volume including necessary cutting of reinforcement if any, stock piling at designated location and disposal of demolished material (Except saleable materials) outside HAL to a distance not exceeding 5 km and stacking servicable and unservicable materials seperately etc., all complete as directed by the Engineer-in-Charge.
Demolition of soling and sub bases of any description including stock piling at designated location and disposal of demolished material (Except saleable materials) outside HAL to a distance not exceeding 5 km and stacking servicable and unservicable materials seperately etc., all complete as directed by the Engineer-in-Charge.
Supplying and fixing in position pre-painted / colour coated corrugated galvalume profile sheets of approved make and colour for roofing and cladding min. 0.50 mm thick (Total coated thickness) and min. 550 MPa yield strength, coated with hot dip alloy of 55% aluminium, 43.50% zinc, 1.50% silicon and finished with resin coat on both surfaces @150 g/m² of coating (Both surfaces) having overall width & laid width as specified & fixed using hot dip galvanised, self drilling & self tapping screws including neoprene & EPDM washers. Penetration & laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners etc. Sheets shall be factory cut & supplied in required length to suit the drawings. Crimping of sheet shall be done wherever necessary. Necessary overlaps as per manufacturer's specification shall be provided. The payment will be done on the actual finished area of the sheet. No separate payment will be made for the laps of sheet, accessories, bolts, nuts, washers, adjustable bolts and support for gutters and other fixtures. These are assumed to be indicated in the net quoted rate. The work shall be all complete as per specifications and as directed by the Engineer-in-Charge. Note: (i) The quoted rate shall be inclusive of overlaps and wastages. (ii) A performance guarantee bond for 5 years for leak proof roofing shall be given by the contractor on non-judicial stamp paper of Rs.500/-. The 10% of completed value of this item shall be dedcuted as defect liability deposit and the same shall be returned after sucessful completion of 5 years from the date of completion of contract / project as a whole.
Supplying and fixing the following plain accessories for galvalume sheet roofing with the same specifications or as per manufacturer's reccomendation including all necessary fasteners, washers, sealants etc., all complete as directed by the Engineer-in-Charge.
Ridge around 600 mm wide
Corner and gable flashings around 400 mm girth
Supplying, fixing, testing and commissioning of horizontal lifeline system designed to provide safe access to roof area. The system shall conform to EN 795:2012, CEN TS 16415:2013, ANSI Z359 and CSA Z259. The system shall have 8 mm SS 316 two line wire system with zinc plated and e-coated steel brackets, detachable travellers, posts and base plates that provide flexible, continuous protection for multiple users working at height. The system shall incorporate an inline shock absorber that minimises loads applied to both the user and the building in the event of a fall. The rate is inclusive of necessary fittings / fixtures like base plates, start & end posts, intermediate & corner posts, absorbers, tensioner assembly, end assembly, intermediate brackets, extended intermediate bracket for gutter and ridge connections, corner bracket, aluminium rivets with specially designed EPDM washer to ensure water tightness, water proofing sealant tape, PPE - body harness and 2 m dual lanyard etc., all complete as per manufacturer's specifications and as directed by the Engineer-in-Charge. Note: The quoted rate shall be for the entire work and nothing extra shall be paid on this account.
Cutting existing water line and jointing with new CPVC line of 25 mm dia including threading/screwing, alterations/additions if any with necessary specials required to connect the new line, all complete as directed by the Engineer-in-Charge.
Supplying, jointing, testing and commissioning, approved make GM body gate valve 25 mm dia with screwed ends etc. complete all as directed by the Engineer-in-Charge.
Supplying, fixing or laying, testing and commissioning the following dia CPVC SDR-11 pipes conforming to IS 15778 of approved make jointed together with solvent on walls/ceiling or in floors including all necessary plain and brass threaded CPVC fittings, clamps, pipe cutting & wastages etc., all complete as directed by the Engineer-in-Charge.
16 mm dia
20 mm dia
25 mm dia
Supplying, fixing, testing and commissioning off white vitreous china floor mounted EWC of size around (475 x 350 x 390) mm or nearest available size conforming to IS 2556 (Part 2) and of approved make with sleek PVC dual flush cistern of around 10 litres capacity conforming to IS 7231, closet fixed to the floor by suitable bolts, cistern fixed on suitable brackets embedded in cement mortar (1:4) or by plug and screws including seat and cover, 'P' or 'S' trap, jointing with cement mortar or putty wherever required, cutting and making good the floors, connecting to sewer line etc. with all necessary fittings and accessories like 15 mm dia CP brass stop cock, 15 mm dia PVC inlet, flush pipe, coupling and lock nut, clamps, washers etc., all complete as directed by the Engineer-in-Charge.
Supplying, fixing, testing and commissioning health faucet (ABS body) mild steel chromium plated suitable for 15 mm dia pipe and of approved make with 1.25 metre long flexible tube & ABS wall hook including 15 mm dia CP brass angular stop cock etc., all complete as directed by the Engineer-in-Charge.
Supplying and fixing light coloured vitreous china flat back large urinal of size around (355 x 340 x 535) mm or nearest available size and of approved make, fixed to the wall by using suitable plugs embedded in cement mortar (1:3) including CP brass flush valve with wall flange, jointing with cement mortar or putty wherever required, cutting and making good the walls and floors, connecting to floor trap etc. with all necessary fittings and accessories like flush pipe, CP spreader, 32 mm dia semi-rigid PVC waste pipe, coupling, clamps etc., all complete as directed by the Engineer-in-Charge.
Supplying, fixing, testing and commissioning light coloured vitreous china wash basin counter sunk type of size around (595 x 420) mm or nearest available size, oval shape and of approved make, including fixing and adjusting to granite counter, connecting to floor trap etc., with all necessary fittings and accessories like 15 mm dia brass CP angular stop cock, 15 mm dia SS pillar cock of approved model & make, 32 mm CP brass waste fitting, 32 mm dia semi-rigid PVC waste pipe, 32 mm CP brass bottle trap with connection pipe and wall flange, 15 mm dia PVC inlet pipe, etc., all complete as directed by the Engineer-in-Charge.
Supplying and laying granite 20 mm thick (Table rubbed and polished) in washbasin counters, cooking platforms, storage counters, shelves and the like including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of granite, chasing & fixing to the wall in CC 1:2:4, round nosing of edges etc., all complete as directed by the Engineer-in-Charge.
Supplying, fixing, testing and commissioning 15 mm dia chromium plated cast copper alloy screw down type fancy bib taps with crutch or butterfly handle conforming to IS 8931, screwed down and fixed with wall flange etc., all complete as directed by the Engineer-in-Charge.
Supplying, fixing, testing and commissioning PVC (SWR grade) floor trap with 75 mm dia outlet of approved make, including connection with PVC soil / waste pipe, necessary 150 mm thick cement concrete (1:2:4) for embedding the trap, providing SS cockroach free floor grating with cup, cutting and making good the floors etc., all complete as directed by the Engineer-in-Charge.
Supplying, laying, testing and commissioning the following dia PVC pipes of 6 kg/cm² SWR grade and of approved make with rubber ring joints conforming to IS 5382, jointed together with solvent including all necessary fittings & specials, bends, branches, sockets, clamps, pipe cutting and wastages, cutting and making good the floors and walls etc., all complete as directed by the Engineer-in-Charge
75 mm dia
110 mm dia
Constructing, testing and commissioning brick masonry inspection chamber of size 455 mm x 610 mm (Clear inside dimension) and depth 450 mm, with sewer bricks having average compressive strength not less than 75 kg/cm² in cement mortar (1:4), C.I. cover with frame (Medium duty) 455 x 610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (Weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with CM (1:3), finish smooth with a floating coat of cement on walls and bed concrete, all as per standard design including cost of materials, labour charges, curing etc., all complete as per specifications and as directed by the Engineer-in-Charge.
Cutting into existing manholes/drains for connecting new drains of 100 mm internal dia, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 smooth finished, and reforming benching as required etc., all complete as directed by the Engineer-in-Charge.
Supply, erection testing & commissioning of LT Panel(PTA)
Incoming
1No- 160A, 415V gr. 36KA breaking capacity, TP+NL MCCB.
Lot - 200A FP, 415V, short circuit rated 36KA for 1sec, Aluminium bus bars with busbar insulators, heat shrinkable PVC sleeves etc.
1Nos- Multi function meter (MFM/MDM)suitable for 3ph, 4 wire, 240V(L-N), 5A, CL-1,RS 485 Port Digital MFM/MDM of EM6400NG of Schneider or any equivalent make meeting technical specification of above MFM complete in all respect.
Earth fault relay with suitable CTs
1 Set-160/5A, current transformers of suitable class and VA burden for metering.
1no 16A 415V gr TP 36KA MPCB of for tapping power for metering and control circuit
1Set - RYB indicating lamps of LED module with 6A SP MCB.
1Set- 6A, MCB for the protection of measuring instruments.
Outgoings:
6Nos- 63A, 415V gr. 10KA breaking capacity, 4P MCB
9Nos- 32A, 415V gr. 10KA breaking capacity, 4P MCB
5Nos- 20A, 415V gr. 10KA breaking capacity, DP MCB
Supply & fixing on wall using suitable fixing arrangement wall mounting type Flame proof 5 pin 63A, 415V, metal clad socket outlet along with 63A TPN MCB for control including 63A flame proof 5pin top & cable end termination box for complete in all respects including necessary interconnections complete in all respects as directed by Engineer-in-charge.
Supply & fixing on wall using suitable fixing arrangement wall mounting type Flame proof 5 pin 32A, 415V, metal clad socket outlet along with 32A TPN MCB for control including 32A flame proof 5pin top & cable end termination box for complete in all respects including necessary interconnections complete in all respects as directed by Engineer-in-charge.
Supply & fixing on wall using suitable fixing arrangement wall mounting type Flame proof 3 pin 20A, 250V, metal clad socket outlet along with 20A DP MCB for control including 20A flame proof 3pin top and cable termination box complete in all respects including necessary interconnections complete in all respects as directed by Engineer-in-charge.
Supply, installation on wall/PEB steel column using suitable mounting arrangements, testing & commissioning of flame proof Air circulators 450mm dia wall mounted type heavy duty oscillating industrial type air circulators along with three speed regulator suitable to operate on single phase 230V gr AC supply with all connected accessories and interconnections, including power cord with flame proof 5A, 3 pin plug top and socket with all necessary accessories complete in all respects and as directed by Engineer-in-charge Note : 3 speed regulator shall be mounted at reachable height as directed by Engineer-in-charge.
Supply, installation, testing & commissioning of wall mounting Air circulator fan 450mm sweep of any approved make with connecting cord with 5A, 3 pin plug top and with all necessary accessories complete in all respects and as directed by Engineer-in-charge Note : 3 speed regulator shall be mounted at reachable height as directed by Engineer-in-charge.
Supply, installation, testing & commissioning of 450mm dia industrial heavy duty flame proof exhaust fan of any approved make with connecting cord with flame proof 6A, 3 pin plug top and with all necessary accessories including making wall openings to mount the exhaust fan and replastering to smooth finish after fixing with matching paint etc, including suitable ventilating louvers complete in all respects and as directed by Engineer-in-charge.
Supply, installation, testing & commissioning of 450 mm dia heavy duty exhaust fan of any approved make with louvers, connecting cord with 6A, 3 pin plug top and with all necessary accessories, including making wall openings and replastering to smooth finish with matching paint etc., complete in all respects and as directed by Engineer-in-charge.
Earthing
Supply & providing earth stations using 600x600x3.15mm thick copper plate electrode complete at 2.5 mtr. below the ground level with 20mm dia class B G.I pipe for watering, G.I funnel etc. & Cement concrete base of minimum size 750x750x100mm thick shall be provided using 1:2:6 CC after necessary excavation, refilling of soil, consolidating, ramming, leveling of soil etc., and providing cement concrete chamber of inside dimension 300x300x300mm with a wall thickness of 120mm using 1:2:6 CC above the base concrete including providing 50mm thick RCC cover including required salt & charcoal, 2runs of 50x6mm copper strip from plate electrode upto top of the chamber etc. as per technical specification enclosed with the tender documents & as per IS 3043 complete in all respects.
Supply, fixing & connecting the 50X6mm(300 sqmm) size G.I strip on wall / clamping to the existing duct wall / fixing on steel structures/ laying 2 ft. below the ground level with necessary excavation, concrete cutting & re-concreting, refilling, consolidation & levelling of soil after laying for interconnection between the earth pits and LT panels/equipment etc.Body earthing as directed by Engineer-in-charge. Note:- Excavation, concrete cutting & re-concreting will be measured separately.
Supply and fixing on the wall 8 SWG GI wire complete with necessary interconnections using suitable bolts & nuts to effect proper earth continuity as per standard practice.
Supply, fixing, testing & commissioning of factory built TPN 4 way flame proof distribution board/box of any approved make suitable capacity incoming bus bars as per OEM, weather proof in cast Alluminium LM-6 enclosur complete with M-25 cable entry to suit incoming cable and 12 nos, M-20 cable entries for outgoing cables from bottom suitable for fixing on wall etc., duly epoxy powder coated with flame proof flexible metallic conduit up to 01 mtr length at all outgoings including 1 no 32A ,TPN MCB as incoming and 12 nos 10 A SP MCB as outgoings & fixing the DB on wall as per site requirement with necessary M.S. angle supports, chipping the wall and replastering to smooth finish etc., wherever required as per site condition, complete in all respects, as directed by Engineer-in-charge.(Refer SLD) Note:- MS-Angle will be measured separately.
Supply, fixing on wall/ ceiling flame proof 4 way junction box of LM6 material including suitable connector inside junction box of model SUDHIR make Cat no:105 or Equivalent make in other approved makes
Supply, fixing on truss/purlins using suitable MS frame work welded to the truss to bringing to truss bottom level/suspending from the truss/purlins using suitable tie rods/necessary suspension arrangement in the light fitting as per site requirement, testing & commissioning of LED Flame proof High bay light fixture of wattage 100 W.The technical parameters of Flame proof High bay lighting fixtures are as below: The lumiare should have Lumen efficacy >100 lm/watt and lumen output not less than 10000 lumens with symmetric beam to be achieved using suitable optics, PF >0.9 and Colour temperature shall be >5700K, IP65 rated operating on single phase 230V voltage 50 Hz AC supply with voltage range 140-270V including necessary interconnections between driver and lighting fixtures. Flameproof cum Waterproof LED Well glass fitting Flat Type COB Model With Multipile Chip in cast Allum Alloy LM-6 Construction suitable for 100 W LED 1no ¾" Stopping plug & 02 Nos PVC Shrouds suitable for ¾" certified by CIMFR Dhanbhad for gas group I IIA And IIB for zone I & II and other standard accessories complete in all respects and as directed by Engineer in-charge. The Flame proof High bay Light fitting shall be of model SUDHIR make Cat no:1240 or Equivalent model in other approved makes. LED used in the lighting fixtures should be one of the approved make.
Supply & fixing on the building at a height of 5-8mtr approx. to existing 40mm dia class B GI pipe with necessary fixing hardwares etc., and testing & commissioning of building light LED light fixture of wattage not exceeding 72watts and lumens output not less than 8640 lumens with necessary interconnections consisting of pressure die cast aluminum housing, optical cover made out of heat resistance toughened clear glass / polycarbonate with IP66, luminous efficiency ≥120lm/w at luminaries level, operating on single phase 230V 50Hz AC supply, efficient heat sink, colour temperature shall be 5600K+400K, suitable optics for maximizing the spread complete in all respects and as directed by engineer-in-change. The luminaries shall have specific lens for optical dispersion including control gear and power factor of control gear shall be >0.95. LM 79 certification for luminaries & LM80 certificate for LED shall be produced. Any approved make fitting meeting the above technical specification has to be supplied.The LED Light fixture shall be of Bajaj ZELA P 86L WH PO TG SD /Equivalent model of approved make luminaries which meets the above technical specification complete in all respect and as directed by Engineer-in-charge. LED used in the fittings shall be of approved make as per List of approved makes in tender document.
Supply, fixing directly to the ceiling/wall testing and commissioning of 10W LED bulkhead light fitting with die cast aluminium body with Poly carbonate front cover, including driver, the driver shall have PF >0.9 and Colour temprature shall be >5700K, IP65 rated operating on single phase 230V voltage 50 Hz AC supply with voltage range 220V-240V including necessary interconnections between driver and lighting fixtures complete in all respect and as directed by EIC. The lighting fixture shall be of Bajaj model no: BIBWP 10W LED /Equivalent make in other approved makes.
Supply, fixing directly to the ceiling/wall using suitable mounting arrangements testing & commissioning of surface mounting Decorative type 10W LED mirror light fitting , including driver, the driver shall have PF >0.9 and Colour temprature shall be >5600K, operating on single phase 230V voltage 50 Hz AC supply with voltage range 140-270V including necessary interconnections between driver and lighting fixtures complete in all respect and as directed by EIC. The lighting fixture shall be BAJAJ model no:BCLSB 10 WH /Equivalent make in other approved makes.
Supply and fixing on existing wall/ceiling, testing & commissioning of surface mounting, Batten type 1X18W/20W T8 LED Tube light (four feet) Luminaries with minimum lumens output of 1600 lumens, comprising of white powder coated CRCA sheet steel housing, operating on single phase 230V 50Hz AC supply, built-in electronic driver, LM 79 certification for luminaire & LM80 certificate for LED tube shall be produced. Other standard accessories including necessary inter-connections, complete in all respects and as directed by engineer-in-chage. The LED tube & batten shall be of Bajaj BLRB DB 118 /Equivalent model of approved make luminaries which meets the above technical specification. complete in all respect and as directed by Engineer-in-charge.
Supply, laying, testing and commissioning of LT cables
3.5C X 95 Sqmm. Al Arm LT Cable.
3.5C X 25 Sqmm. Al Arm LT Cable.
4C X 16 Sqmm. Al Arm LT Cable.
3C x 2.5 Sqmm. Cu Arm LT cable.
3C x 4 Sqmm. Cu Arm LT cable.
Supply, & Fixing of following LT cable end joints
3.5C x 95 Sqmm. Al Arm LT cable.
Supply, & Fixing of following flame proof LT cable end joints
Supply and connecting indoor type flame proof cable end joints cable end joints for 3.5C x 25 Sqmm. Al Arm LT cable.
Supply and connecting indoor type flame proof cable end joints for 4C x 16 Sqmm. Al Arm LT cable.
Supply and connecting indoor type flame proof cable end joints cable end joints for 3C x 2.5 Sqmm. Cu. Arm LT cable.
Supply and connecting indoor type flame proof cable end joints cable end joints for 3C x 4 Sqmm. Cu. Arm LT cable.
Point Wiring
Wiring to single light point controlled by 1 No 6A, 250V gr. flush type modular SP switch complete in all respects.
Wiring to two light point controlled by 1 No 6A, 250V gr. flush type modular SP switch complete in all respects.
Wiring to exhaust fan point using 6A, 250V gr. flush type modular SP switch housed along with other lighting switches/separate switch box if required and 3pin 6A, 250V gr. modular type socket housed near the exhaust fan complete in all respects.
Wiring to power point consisting of Gang of sockets 3Nos of 6A, 250V grade, 5pin modular type Universal flush type socket outlet & 3Nos of 6A, 250V grade flush type modular switch of approved colour for control with necessary interconnections complete in all respects.
Wiring to flush type 15 A Power socket outlets from the nearest DB in concealed wiring system using suitable size 2mm thick rigid PVC conduit with all conduit accessories such as junction boxes, bends, reducers, clamps, collars, elbows etc., and wiring with 2 runs of 4 Sq.mm for phase and neutral and 1 run of 2.5 sq.mm for earthing FRLS multistranded copper PVC insulated 1100V gr Wire with ISI mark including suitable size modular type MS concealed box with base plate, glossy finish front cover etc., including supply and fixing of universal flush type modular 3 pin 15 A , 250V gr. power socket outlet & 15A, 250V gr. flush type modular SP switch with neon indicator including with necessary interconnections, chipping the wall & replastering to smooth finish by using chicken mesh wherever necessary complete in all respects & as directed by Engineer-in-charge.
Wiring to flame proof Air circulators Power socket outlets from the nearest DB in concealed wiring system using suitable size 2mm thick rigid PVC conduit with all conduit accessories such as junction boxes, bends, reducers, clamps, collars, elbows etc., and wiring with 2 runs of 2.5 Sq.mm for phase and neutral and 1 run of 2.5 sq.mm for earthing FRLS multistranded copper PVC insulated 1100V gr Wire with ISI mark including suitable size modular type MS concealed box with base plate, glossy finish front cover etc., including necessary interconnections, chipping the wall & replastering to smooth finish by using chicken mesh wherever necessary complete in all respects & as directed by Engineer-in-charge.
Excavation of cable trench in all types of soil, refilling, consolidating of soil after laying the cable including ramming and levelling to smooth finish as per the Technical specifications enclosed and as directed by the Engineer-in-charge.
Concrete cutting/Chipping the existing 1:2:4 cement concrete road /pavements / flooring of 150mm thick including removing debris from the work site and depositing the same at a place as shown by EIC complete in all respects.
Re-concreting the cut portion with 1:2:4 cement concrete by employing 20mm graded aggregate granite of 150mm thick to smooth finish including curing complete in all respects and as directed.
Fabrication, Supply, fixing/welding to the existing steel struss/wall/ steel columns/ceiling suitable size M.S. angles/flats with supports, suspenders etc for fixing cable trays/DB's light fixtures etc. as per site requirement including necessary fixing hardwares, clamps etc and painted with 2 coats of enamel spray paint over a coat of good primer complete in all respects and as directed by Engineer-in-charge.
Supply, Fixing, in flush with wall/on Aluminium partition as per site condition, testing & Commissioning of 2no's Modular type RJ-45 sockets for two numbers of Data points including supply of suitable size modular type MS/PVC surface mounting box with base plates, front covers, etc., with necessary interconnections and chipping the wall, replastering to smooth finish etc., wherever required complete as directed by Engineer-in-charge.
Supply & fixing in flush with existing work station cubical(Modular Table) wire ways cutouts/PVC race ways, testing & Commissioning of 1 No. of Twin RJ-11 telephone socket outlets including supply of base plates, front covers, etc., with necessary interconnections complete as directed by Engineer-in-charge. Note:- Connecting minimum 3 nos of telephone socket outlets in one circuit.
Supply and drawing in the existing PVC conduits in floor/wall/ceiling/partition, Cat 6 UTP 4-Pair cable including providing end termination by crimping on both ends and necessary interconnections complete in all respects for LAN/ Internet point as directed by Engineer-in-charge.
Supply, laying in the already excavated cable trench/existing duct/fixing on wall/cable tray/iron structure using suitable clamps etc./ encasing in pipe, testing and commissioning of 10 pair jelly filled armoured copper conductor of 0.5mm dia polyethylene insulated cover, twisted into pairs, colour coded, pairs laid up, fully filled with petroleum jelly as a moisture barrier, core wrapped with non-hygroscopic polyester tape to contain the jelly, covered with aluminium poly-laminates screen, polyethylene sheath extruded over aluminium screen, polyethylene tape over the above sheath, armoured with galvanised steel tape and outer polyethylene sheath underground telecommunication cable including both end terminations on the existing krone type junction box complete in all respects.
Supply & drawing in the existing MS conduits 0.5 mm dia copper conductor PVC insulated 5 pairs colour coded and twisted unarmoured telecommunication cables in the existing PVC conduit as per standard practice including necessary inter connections & end terminations.
Supply & fixing on wall/grouted to floor upto 1200mm above ground level as per site requirement using suitable size MS angle iron frame work finished with two coats of enamel spray paint over a good primer & providing 10 pair krone type telephone connector junction box including krone connector with necessary mounting frame housed in suitable size FRP box with hinged lockable cover complete in all respects.
Supply and fixing on the wall using suitable angle iron frame work, fixing hardware, suitable size weather proof SMC box(not less then 190x160x90) with hinged lockable cover and providing 10A 8way heavy duty PVC connector inside the SMC box for controlling building light as directed by Engineer -in-charge.
Supply and embedding on wall/floor/ceiling, 2mm thick 20MM dia PVC conduit, including necessary conduit accessories like reducers, junction boxes, connector blocks, elbows etc., complete in all respects including chipping the wall/floor and replastering to smooth finish to match the existing wall/floor finish using chicken wire mesh wherever necessary as per site condition and as directed by Engineer-in-charge.
Supply & fixing on the building at a height of 5-8mtr approx. including supply and fixing GI pipe bracket made out of 40mm dia class B GI pipe of 1.5Mtrs long bent to shape with necessary fixing hardwares etc. for fixing building light fixrures as directed by Engineer-in-charge.
Perforated type cable tray
Supply and laying of 100mm dia PN10 HDPE pipe of confirming to IS 4984:1995 in the excavated trench/duct/at road crossings for encasing cables complete and as directed by Engineer-in-charge.
Supply & fixing of Addressable type multisensor detector with heat and smoke combination with base and inbuilt short circuit isolator or isolator mounted with the base or separate isolator module to be provided for each detectors complete in all respects as per technical specification and shall comply BS-5839/EN54/IS2189 standard for installation and product shall be UL / FM / Vds approved. Edwards make
Supply and fixing on wall, testing and commissioning of Addressable type Manual Call point resettable type with inbuilt short circuit isolator (in case short circuit isolator is not inbuilt, the price of this item shall be inclusive of an independent short-circuit isolator along with each detector)complete in all respects as per technical specification and shall comply to EN54/IS2189/ UL/Vds standards.Edwards make
Supply, erection on wall at approx. 4 mtrs height testing & Commissioning of Addressable type Audio Alarm unit (Electronic hooter) with strobe (Red Lens) with inbuilt short circuit isolator (in case short circuit isolator is not inbuilt, separate short-circuit isolator to be provided and the cost of same has to has to be included in the cost this item itself). It shall have built in facility to set the sound decibel and tone complete in all respects, as per technical specification and shall comply to EN54/ IS2189/ UL/Vds standards. Edwards make
Supply, laying and fixing directly to the ceiling/on wall / above false ceiling existing pipe etc, testing & commissioning of 2 Core X1.5 sqmm copper XLPE insulated FRLS with ISI mark armoured RED colour LT cable along with required accessories, terminations glands, including suitable size PVC conduit where ever required as directed by EIC to complete the installation as per the technical specification.
All the above fire alarm detectors loops have to interconnected with existing Edward make Fire alarm panel installed at newly constructed store building scope of work includes Re-Programming, testing & commissioning and Integration of new fire alarm system proposed at GHE/GSE hangar with existing Edwards make fire alarm panel at Existing store building complete in all respects and as directed by OIC/EIC
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
raw.json
RAW_JSON
TN35.pdf
TENDER_DOCUMENT • 1.38 MB
CIVILTENDERDRAWING.pdf
TENDER_DOCUMENT • 0.47 MB
ElectricalTenderDrawing1.pdf
TENDER_DOCUMENT • 0.48 MB
ElectricalTenderDrawing2.pdf
TENDER_DOCUMENT • 0.22 MB
55APQF.xlsm
TENDER_DOCUMENT • 0.04 MB
55AChecklist.pdf
TENDER_DOCUMENT • 0.19 MB
55APBF.xlsm
TENDER_DOCUMENT • 0.07 MB
55APQ.pdf
TENDER_DOCUMENT • 0.21 MB
55AECSForm.pdf
TENDER_DOCUMENT • 0.48 MB
ElectricalTenderDrawing3.pdf
TENDER_DOCUMENT • 0.26 MB
55APB.pdf
TENDER_DOCUMENT • 0.48 MB
55AUndertaking.pdf
TENDER_DOCUMENT • 0.57 MB
55Aamd.pdf
TENDER_DOCUMENT • 0.15 MB
55ATB.pdf
TENDER_DOCUMENT • 2.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .