Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.3 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED BEING LOWEST BIDDER | |
| 2 | L2₹26.7 L+₹2.1 L (8.63%)Rejected-Finance | L2 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 3 | L3₹27.5 L+₹2.9 L (11.7%)Rejected-Finance | L3 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 4 | L4₹27.6 L+₹3.0 L (12.2%)Rejected-Finance 02 PADRI SHIV NAGAR SHIV NAGAR MAHARAJGANJ UTTAR PRADESH 273303 | MAHARAJGANJ | UTTAR PRADESH | 273303 | L4 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 5 | L5₹28.7 L+₹4.1 L (16.6%)Rejected-Finance AT POST SONAJ TAL MALEGAON DIST NASHIK | MALEGAON | NASHIK | MAHARASHTRA | L5 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
20 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE KIRKEE
Headquarters CWE Kirkee, Military Engineer Services, Range Hills Road, Kirkee, Pune-411003
REPAIR TO HARDSTANDING, PLINTH PROTECTION, SOUCER DRAIN, AREA DRAINAGE AT BEG AND CENTRE UNDER AGE B/R-II IN GE (CENTRAL) KIRKEE
2023_MES_581931_1
CWE/KKE/TOKEN-75 OF 2022-23
Open Tender
Civil Works
Item Rate
270 days
KIRKEE
AS PER TENDER
6 documents required · 6 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹99,000
Yes
20 Apr 2023
20 Feb 2023
23 Mar 2023
21 Feb 2023
20 Mar 2023
7 Mar 2023
21 Feb 2023 - 27 Feb 2023
Amount
Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground surfaces complete all as specified and as directed by the Engineer-in-Charge.
Excavating in post holes each n.exc 0.5 cum getting out returning filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25 cm watering and removing surplus soil to a distance n.exc 50 m and making good surface complete all as specified and as directed by the Engineer-in-Charge.
M & L for cement conc 1:3:6 type C-2 (40 mm graded aggregate) as in post/strut fdn complete all as specified and as directed by the Engineer-in-Charge.
M&L for MS work conforing to Fe-410-0 of Fe-310-0 Grade for fencing posts and struts in fencing including cutting bending top to shape as directed drilling holes matching for barbed wire, including fillet on back side of fencing post and all necessary drilling work complete all as specified and as directed by the Engineer-in-Charge.
Dismantling mild steel work of any description and in any position complete all as specified and as directed by the Engineer-in-Charge.
M & L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe-410-W(Gde- E-250) quality-A complete all as specified and as directed by the Engineer-in-Charge.
S & F, in repairs, Galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacings & straining and fixing to any type of post including screwing or tying at crossings with and provision of galvanised mild steel wire, staples as directed including taking out existing damaged barbed wire complete all as specified and as directed by the Engineer-in-Charge.
M & L for mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders,walk ways; railings con forming to Fe.290.Gde-E-165 complete all as specified and as directed by the Engineer-in-Charge.
Dismantling chainlink fencing of any gauge & size not exceeding 4 Kg/Sqm complete all as specified and as directed by the Engineer-in-Charge.
Supply only Chain link fencing using 3.15mm dia GI wire mesh including line wires, any mesh, size & type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and as directed by the Engineer-in-Charge.
Fixing only chain link fencing including line wires, any mesh, size & type to any type of standards, rails, straining blots, etc. including provision of binding wire complete all as specified and directed.
S & F flat iron of size as directed as in fixing clamps or support to chain link fencing, stifners etc fixed with nut and bolts including making necessry holes complete all as specified and as directed by the Engineer-in-Charge.
S& F 10mm dia and over round bars cut to length bent to shape for stiffeners etc and similar work complete all as specified and as directed by the Engineer-in-Charge.
Mild steel screw bolts (machine made) 5 ot 10mm dia of shank with hexagonal or square heads at one end and screwed the othere, each screw end to be fitted with washers and one hexagonal or square nut exc 5cm but n exc 10cm long complete all as specified and as directed by the Engineer-in-Charge.
M & L for preparation of new steel and iron surfaces of any description over 10cms width or girth & applying 2 coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed by the Engineer-in-Charge.
Demolition of PCC in any position not otherwise specifically provided for, as in surface channel, drains, manholes, copings, ground floors and pavings of any description and in any position and removing debris out side MD land complete all as specified and directed by Engr-in-Charge.
M&L for 100 mm thick, PCC (1:4:8) type B-2 using 40 mm graded stone aggregates as in sub base complete all as specified.
M&L for 75 mm thick, PCC (1:4:8) type B-2 using 40 mm graded stone aggregates as in sub base as Plinth protection complete all as specified and as directed by the Engineer-in-Charge.
M&L for 25mm thick crushed stone dust/sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed by the Engineer-in-Charge.
M&L for 60mm thick machine pressed glossy finish precast concrete interlocking paver block any shape and size & Colour M-35 grade with grey cement no pigment confirming to IS 15658-2006 and including dismantling of exisiting paver any type and description complete all as specified and as directed by the Engineer-in-Charge.
M & L for glass dividing strips 3mm thick and 38mm width inserted in position conform to design complete all as specified and as directed by the Engineer-in-Charge.
Dismantling of precast interlocking paver blocks/ chequered tiles laid dry of any description thickness & sizecomplete all as specified and as directed by the Engineer-in-Charge.
M & L for PCC 100 mm thick 1:2:4 type B2 as in hardstanding/floor (using 20mm graded stone aggregate) finished even & smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L for finishing surface of concrete by brooming with brooms concrete is green complete all as specified and as directed by the Engineer-in-Charge.
M&L for construction (Dummy) joint 65 mm deep x 100 mm wide of Grade "A" and filled with sealing compound complete all as specified and directed by the Engr-in-charge.
M&L for screed bed or bedding layer of mortar 20mm thick average thickness for laying floor finishes in cement mortar 1:6 complete all as specified.
M&L for coloured glossy finish chequered cement concrete tiles of size 30 cm x 30 cm x25 mm thick with grey cement and pigments , set jointed and pointed in neat cement slurry in floors over existing screed bed complete all as specified and as directed by the Engineer-in-Charge.
Demolition of Brickwork or stone/boulder masonry, built in cement/cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and as directed by the Engineer-in-Charge.
M & L for pre cast cement concrete solid block masonry with solid block of the grade C1 (1:3:6) set in CM (1:6) complete all as specified and as directed by the Engineer-in-Charge.
ditto All as per item no 28 above but except material.
M & L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge.
ditto All as per item no 30 above but except material.
M & L for providing cement concrete type B-1 (1:2:4) using 20 mm graded crushed stone aggregate as in coping/benching and the like including necessary form work complete all as specified and as directed by the Engineer-in-Charge.
Racking out joints/pointing to random rubble or polygonal rubble uncorsed or brought up to courses masonry built in cement or lime mortar, complete all as specified and as directed by the Engineer-in-Charge.
M & L for taking down cement of cement lime plaster of any description on brick or stone walls etc including ranking out joints hacking for key scrubbing down with water etc complete all as specified and as directed by the Engineer-in-Charge.
M& L rendering 15 mm thick on fair faces of brick/block masonry surfaces of wall in CM 1:4 using water proofing compound @ 3% by wt. of cement and finishing plastered surfaces even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge. NOTE :- Rate for WPC deemed to be included.
M&L for Preparation of new surfaces (Plastered or un-plastered) of walls and applying two coats of cement base paint over a coat of primer complete all as specified.
M&L for preparation of old decorated plastered or unplastered surfaces of wall, cornices etc by brooming down or steel wire brushing, scrapping down, smoke soot, moulds, moos efflorescent and trading oil and greasy spots and applying one coats of cement base paint (white or tinned) complete all as specified and as directed by the Engineer-in-Charge.
M & L for preparation of old painted steel surfaces of any description over 10 cm in width or girth not otherwise described and applying one coat of synthetic enamal paint complete all as specified and as directed by the Engineer-in-Charge.
Dismantling of rusted/damaged mild steel sheeting of any thickness and size from iron gates of any size and welding of 1.25mm thick sheet welded or shouldered to angle iron frame complete all as specified and as directed by Engr in charge.
M&L for plain,black mild steel sheeting in gates, 1.25mm thick sheet welded or shouldered to angle iron frame and all complete all as specified and as directed by the Engineer-in-Charge.
M&L for applying two coats of synthetic enamel paint on new steel surface over a coat of red oxide primer complete all as specified and directed by Engr in charge.
Restraining and resecuring of barbed wire including removal & refixing of concerntina coil wherever required in single/double security fencing/on security wall complete all as specified and as directed by the Engineer-in-Charge.
V.R.PRAJAPATI AND CO.
MANIYA CONSTRUCTION CO
JP ENTERPRISES
MAHESH DADAJI BACHHAV
M/S K.D.MATE
AGS ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .