Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.2 LAccepted-AOC AT AMRITPUR PO NB CHILKA DIST KHURDA ODISHA 752 037 | KHORDHA | ODISHA | 752037 | L1 | Accepted-AOC Accepted being L1 bidder | |
| 2 | L2₹17.3 L+₹48,743 (2.90%)Rejected-Finance | L2 | Rejected-Finance Being L2 bidder |
Tender Value
₹15.0 L
EMD Value
₹30,060
Closing Date
30 Jul 2022, 6:00 pmClosed
Shri Avinash Mishra IDSE GE
Garrison Engineer (I) (CG) Bhubaneswar, Plot No 190/702, Kokila Residency, 2nd Floor, Anant Vihar, Post-Pokhariput, Bhubaneswar- 751020
PROVISION OF ALUMINIUM SLIDING WINDOWS IN PASSAGES ACOUSTIC SOUND PROOF IN CONFERENCE HALL AND RENOVATION OF COMDIS OFFICE INCLUDING PROVISION OF OIL BOUND DISTEMPER IN PASSAGE AND STAIR CASE
2022_MES_529200_2
8288/BBSR/05/E8
Open Tender
Miscellaneous Works
Item Rate
120 days
Paradip
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (I) (CG) Bhubaneswar
₹30,060
Yes
8 Sept 2022
8 Jul 2022
1 Aug 2022
8 Jul 2022
30 Jul 2022
16 Jul 2022
8 Jul 2022 - 13 Jul 2022
Amount
Supply and fixing powder coated anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. (minimum thickness of powder coating 50 micron complete all as specified and directed.
Supply and fixing powder coated anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. (Thickness or powder coating not less than 50 micron). complete all as specified and directed.(Note- Glass shall be measured and paid separately)
Supply and fixing aluminum powder coated anodized grill DG 202 powder coated (weight : 4.121 Kg/Sqm) square , rectangular, circular or similar type of shape, aperture not exc 6 cm in length or width fixed with `H’ or `F’ channel 38 mm x 12 mm x 1.30 mm (Sec No 8778) complete all as specified and directed. Make Grill No 20 of DECOREL or similar make as mentioned in PS.
Supply and fixing 5 mm thick Sheet glass, ordinary quality and aluminium glazing cleats/beads in square not.exc 0.5 sqm in eachpane fixed to aluminum framing complete all as specified and directed.
Supply and fixing 5 mm thick Sheet glass, ordinary quality and aluminium glazing cleats/beads in square exc 0.5 sqm in eachpane fixed to aluminum framing complete all as specified and directed.
Supply and fixing Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
Material and labour for 20mm thick Granite (of any type) tiles machine cut, in skirting, dado, riser, cooking platform etc laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete, over and including 10mm thick rendering in cement mortar(1:4) complete all as specified and directed.
Material & labour for preparation of old distempered surfaces of wall by washing, rubbing down, stopping including brooming down smoke soot, moulds, moss and efflorescent salts and trading oil greasy spots and applying one coat of oil bound distemper complete incl filling putty/filler work where ever drepression foud in wall complete all as specified and directed.
Providing and supplying Armstrong ‘Optra Acoustical Wall Paneling’ with square edges made of fibre glass substrate 25mm thick and wrapped on the front side with an acoustically transparent and classified for Fire reaction Class A as per ASTM E-84, fabric with an option of colors – Husk, Copper, Sangria, Sesame, Coffee, Charcoal, Titanium, Flame, Peanut & Shell as per the choice of the Architect of size 600X1200 mm providing a minimum sound absorption level of 0.85 NRC to be affixed to wall using Wall panel impalers supplied by M/s Armstrong Industries India Pvt. Ltd and construction adhesives as per the instructions laid down by the manufacturer. INSTALLATION: An appropriate vapour barrier (by others) shall be applied/installed on the vertical surface before the installation to properly seal against entry of any moisture. Vapour barrier (by others) shall be installed as per manufacturers recommendation. Install aluminium extrusion of size 3000(L) x 24(H) x 15.5(W) mm fixed with clip as approved by the architect on the solid wall/partition to provide level and plumb surface for fixing Armstrong Keel. Install Keel vertically using screws and plugs at spacing of not more than 600mm centre-to-centre. The first and last keel should not be more than 150 mm from the ends. Trim the tongue of the first bottom panel and install using headless nail with groove side upward. Subsequent panels are installed with tongue side downward by engaging with each other using tongue and groove mechanism and secured by inside clip. Continue this process until required height is achieved. Shorter butt edges need to be joined using industrial/wood glue. The keel shall also be used for transition of the butt end of adjacent panel at every 7.2 m. Install the skirting (provided by others) of width 50 mm or more as required by the Architect/Engineer-in-Charge. Finish off the edges using wooden moulding of matching colour (by others). Installation should be carried out as per Armstrong recommended procedure.
Taking down carefully copper/aluminium point wiring including sunken M S Boxes (Light, Fan, socket or power) complete,(fitting such as switches,ceiling roses,call bell,pendants,regulators,socket etc by unscrewing from board carefully and making good disturbed surfaces of walls,floors etc complete all as specified and directed.
M&L for point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm for earth continuity wire, to be drawn in and including PVC conduit heavy duty with concealed wiring, MS sheet metal switch/Terminal flux box 1.2 mm thick and modular white switch board cover plate or PVC moulded switch board and brass screws with cap washers for one light/Fan point controlled by one single way switch including all necessary wall cutting and making good disturbed surface complete all as specified and directed.
All as per item No. 11.00 above but for independent 5 Amps switch socket out let using 1.5 Sq mm wire with 1.5 Sqmm wire for earth continuity conductor complete all as specified and directed.
All as per item No 11.00 here-in-before but with copper conductor 2.5 sqmm for One 3 pin socket outlet, 16 amps on independent board complete all as specified and directed.
Supply and fixing including connection of Modular switch flush button type single pole one way 6 Amps complete all as specified and directed. (Make :Legrand/Havells/ Carbtree/Roma)
Supply and fixing including connection of Modular switch flush button type single pole one way 16 Amps complete all as specified and directed. (Make::Legrand/Havells/ Carbtree/Roma)
Supply and fixing including connection of Modular switch with indicator flush button type single pole one way 25 Amps complete all as specified and directed. (Make:Legrand/ Havells/ Carbtree/Roma)
Supply and fixing including connection of Modular socket outlet 6 Amps,2 in 1, 2/3 pin flush type,2 modules complete all as specified and directed. (Make::Legrand/Havells/ Carbtree/Roma)
Supply and fixing including connection of Modular socket outlet, 2 in 1,6 pin 6/16 amps flush type ,2 modules complete all as specified and directed. (Make::Legrand/Havells/ Carbtree/Roma)
Supply and fixing including connection of Modular socket outlet, 25 amps 3 pin flush type ,2 modules complete all as specified and directed. (Make::Legrand/Havells/ Carbtree/Roma)
Supply and fixing including connection of Modular MS flush Box ,3 modules to fix in wall or panel complete all as specified and directed. (Make::Legrand/Havells/ Carbtree/Roma)
Supply and fixing including connection of Modular MS flush Box ,4 modules to fix in wall or panel complete all as specified and directed. (Make:Havells/Carbtree/Roma)
Supply and fixing including connection of Modular MS flush Box ,6 modules to fix in wall or panel complete all as specified and directed. (Make:Havells/Carbtree/Roma)
Supply and fixing including connection of Modular white cover plate with frame ,3 modules to fix on flux box or panel complete all as specified and directed. (Make:Havells/Carbtree/Roma)
Supply and fixing including connection of Modular white cover plate with frame ,4 modules to fix on flux box or panel complete all as specified and directed. (Make:Havells/Carbtree/Roma)
Supply and fixing including connection of Modular white cover plate with frame ,6 modules to fix on flux box or panel complete all as specified and directed. (Make:Havells/Carbtree/Roma)
Supply and fixing of Square Recessed mounted LED of full lit luminaire with glare free uniform illumination of capacity 36 watt (2ftx2ft) PDC white finish aluminium housing with high translucent frosted plastic diffuser with efficacy of 100lm/w complete all as specified and directed. ( Make/Model No:-LCTLRNE-36-FO-CDL(POLARIS NIO-I) of Crompton or equivalent of Philips & Havells/Bajaj.
Taking down unserviceable sub main /Sub circuit wiring of any type and size including conduit, batten wiring for necessary repair/replacement complete all as specified and directed.
M&L for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable of size 2 x 4.0 Sqmm and earth continuity conductor of size 1 x 4.0 Sqmm to be drawn into PVC conduit conceald wiring complete all as specified and directed.
M&L for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable of size 4 x 6.0 Sqmm and earth continuity conductor of size 2 x 6.0 Sqmm to be drawn into PVC conduit conceald wiring complete all as specified and directed.
Taking down old unseviceable DBs & Supply and fix factory made ETPN DBs for MCCB Incomer, IP-43 protection with metal door with suitable Size busbar with neutral busbar, earth bar cables ties for cable management fully insulated busbar with set of wires and door earthing for provision of 63 Amps MCCB as incomer and included with SP/TP MCB's as outgoing 4 way 63 A MCCB+12 etc complete all as specified and directed Make- Legrand Cat part No 5076 70 suitable for 63 Amps MCCB as incomer & 12 Nos SP Out going Legrand/Siemens/Schneider.
Taking down old unseviceable MCCBs & Supply and fixing MCCBs 63 Amps capacity, 415 volts, 4 pole, 25 KA, thermal magnetic complete all as specified and directed Make Legrand/Siemens/Schneider
Taking down old unseviceable MCBs & Supply and fix MCB single pole 240 volts, 6 to 32 amps, 50HZ, 10 KA. , ‘C’ series complete all as specified and directed. Make : Legrand or eqvt in Siemens/Scheinder
Taking Down Voltage Stabilizer and refixing the same position after complete the Civil work complete all as specified and directed.
SANJAYA KUMAR PALAI
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .