Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.8 LAccepted-AOC 194 IIND FLOOR POCKET 9 SECTOR 24 ROHINI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹35.9 L+₹47,974 (1.36%)Rejected-Finance G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹46.8 L+₹11.4 L (32.2%)Rejected-Finance WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹46.9 L+₹11.5 L (32.6%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | Rejected-Technical | - | Rejected-Technical Not Enlisted in appropriate category |
| Sl No | Description | Qty | Unit | Sumit Enterprises L2 | Precision Safety Equipment Limited L4 | Flint India L3 | JYOTI CONTRACTORS AND TRADERS L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | M&L for comprehensive maintenance and repairs / rectification of defects by electrically and technically by checking all indicators, SMPS, mother board, card , electrical connections and replacement of faulty service parts of complete with fire alarm system of make and model installed in in following locations:-
(i) CAMERO AREA
(a) 07 No's Addressable Panel (Make-HONEY WELL)
(b) 01 No's Conventional Panel (Make- AGNI)
(ii) HQ WAC Area :-
(a) 02 No's Addressable Panel (Make- HONEYWELL)
(b) 01 No's Conventional Panel (Make-AGNI)
(c) 01 No's Addressable Panel (Make-APPOLO)
NOTE FOR ITEM NO 1 ABOVE :- ALL DEFECTIVE PART WHICH ARE REQUIRED TO REPLACE SHALL BE MEASURED AND PAID SEPERATELY UNDER RESPECTIVE ITEMS
(a) FIRE ALARM CONTROL PANEL : The functions of controls panel and indicating equipment will be checked by the operation of a trigger device in each zone. All fault indicator and their circuits will be checked by stimulation of fault conditions of any type fie alarm panel.
(b) HEAT DETECTOR : Heat detectors will be tested by aim a heat lamp, blow-dryer, or heat gun at the heat detector. The detector alarms should sound within three or four seconds after apply the heat source.
(c) SMOKE DETECTOR : Smoke detector will be cleaned periodically so as to remove dust or dirt that accumulates on them due to local ambient conditions at least each detector is cleaned once in month. Smoke detectors will be tested by apply a small spray of smoke detector test aerosol. The detector alarms should sound within three or four seconds after apply the heat source.
(d) MANUAL CALL POINT HOOTERS : All manual call points will be operated once a monthly by removing glass or by actual breaking of glass so as to ensure that system is capable of operation under alarm conditions and all hooters give proper sound
(e) RESPONSE INDICATORS : All detectors which are placed in side a cabin of room will be tested by initiating the particular detector so as to ensure the proper working of response indicator
(f) WIRING & CABLES : A visual inspection will be made so that structure or occupancy changes does not damage cables and sitting of trigger devices (manual call points smoke detector and heat detector.
(g) MONTHLY LOG SHEET WILL BE MAINTAINED FOR MONTHLY INSPECTION AND TESTING : Monthly inspection and testing will be done in the monthly maintained log sheet. Log sheet will be produced to the Engineer-in-charge duly completed on 1st day of every month.
NOTE :- (a) Replacement of parts will be measured and paid seperately.
(b) If service is not carried out by the contractor on due date Rs 1000.00 per day for each service recovery will be made.
(c) Contractor will provide One Technician and One helper from 0900 to 1700 hrs in all working days for day to day services for each area (CAMERO & WAC).
(d) The maint shall be carried out through manufacturer representative or his authorised rep. (e) Any other work such as updation of location in fire alarm panel or at location deemed included in quoted rate. | 11 | Per Month | 50,200 ₹5,52,200 | 1,20,000 ₹13,20,000 | 40,000 ₹4,40,000 Lowest | 55,000 ₹6,05,000 |
| 2.00 | Supply, installation, testing and commissioning in replacement of Intelligent Analog Addressable MuliticriteriaType Detector Complete with Dual LED, Hard Addressable Having rotary decade Address swicthes from 01-99, complete with Mounting Base Complete as required Conforming to BS 5839 Standards and Duly Approved by EN54/LPCB//UL complete all as specified and directed by Engineer-in-Charge. | 724 | Each | 2,390 ₹17,30,360 | 2,200 ₹15,92,800 | 2,800 ₹20,27,200 | 1,850 ₹13,39,400 Lowest |
| 3.00 | Supply, installation, testing and commissioning in replacement of fault isolator with base with termination preferably after every 20–30 devices and shall be able to isolate electrical short circuit in the wiring etc. as required complete all as specified and directed by Engineer-in-Charge. | 80 | Each | 2,062 ₹1,64,960 | 3,540 ₹2,83,200 | 4,000 ₹3,20,000 | 2,050 ₹1,64,000 Lowest |
| 4.00 | Supply, installation, testing and commissioning in replacement of Intelligent Analog Addressable Type Manual Call Point having Surface or flush mounting Option fully complaint to EN54 having Rotary Decade Swicthes for Addressing from 01-99 complete with Back Box for Mounting Complete as required conforming to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL/BSA complete all as specified and directed by Engineer-in-Charge. | 33 | Each | 4,190 ₹1,38,270 | 4,850 ₹1,60,050 | 5,600 ₹1,84,800 | 2,800 ₹92,400 Lowest |
| 5.00 | Supply, installation, testing and commissioning in replacement of Response Indicators for getting fire indications of detectors installed above false ceiling area interconnecting to loop cable complete all as specified and directed by Engineer-in-Charge. | 256 | Each | 25 ₹6,400 Lowest | 350 ₹89,600 | 155 ₹39,680 | 110 ₹28,160 |
| 6.00 | Supply, installation, testing and commissioning in replacement of Addressable Type Loop Powered Hooter Cum Strobe complete with Mounting Base as required conforming to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL/BSA complete all as specified and directed by Engineer-in-Charge. | 25 | Each | 1,420 ₹35,500 Lowest | 4,250 ₹1,06,250 | 9,500 ₹2,37,500 | 6,000 ₹1,50,000 |
| 7.00 | Supply & fix in replacement of battery maintenance free 12 volt 24 AH complete all as specified and directed by Engineer in Charge. | 10 | Each | 4,190 ₹41,900 | 2,250 ₹22,500 Lowest | 3,900 ₹39,000 | 2,600 ₹26,000 |
| 8.00 | Supplying, drawing, connecting, testing & commissioning in replacement of 2core, 1.5 sq. mm. stranded copper conductor, pvc insulated PVC sheathed,aluminium myler tape shielded FRLS wire in existing conduit complete all as specified and directed by Engineer-in-Charge. | 1,751 | RM | 99 ₹1,73,349 | 240 ₹4,20,240 | 83 ₹1,45,333 | 80 ₹1,40,080 Lowest |
| 9.00 | Supply and laying in position in replacement of the following sizes of 25/20mm Dia PVC. conduits including providing all accessories complete all as specified and directed by Engineer-in-Charge. (For Fire Detection) | 1,720 | RM | 55 ₹94,600 | 45 ₹77,400 | 35 ₹60,200 | 20 ₹34,400 Lowest |
| 10.00 | S & F in replacement of Loop driver card suitable for fire alarm/detection control panel complete all as specified and directed. | 5 | Each | 16,500 ₹82,500 | 13,000 ₹65,000 Lowest | 32,200 ₹1,61,000 | 38,000 ₹1,90,000 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
8 Sept 2025, 6:00 pmClosed
GE (AF) SUBROTO PARK
GE (AF) Subroto Park, Delhi Cantt Delhi-110010
As described in Bill of quantities
2025_MES_725737_1
GE/SP/TOKEN-33/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE (AF) SUBROTO PARK
As per NIT and tender documents
9 documents required · 9 mandatory
₹500
GE (AF) SUBROTO PARK
₹96,000
Yes
29 Oct 2025
12 Aug 2025
11 Sept 2025
12 Aug 2025
8 Sept 2025
27 Aug 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .