Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.7 LAccepted-Finance 30 74 BLOCK NO EXTRA 30 TRILOK PURI DELHI EAST DELHI 110091 | EAST | DELHI | 110091 | ₹37.7 L | L1 | Accepted-Finance Accepted |
| 2 | L2₹41.0 LAccepted-Finance | ₹41.0 L | L2 | Accepted-Finance Accepted |
Tender Value
₹56.7 L
EMD Value
₹1.1 L
Closing Date
21 Jan 2026, 3:00 pmClosed
Executive Engineer(E)
Judiciary Electrical Division-I, PWD, Yamuna Western Bank, Lok Nayak Setu, New Delhi-110002
RMO of various Electrical and Mechanical Services Mandoli Prison Complex Delhi.
2026_PWD_284807_1
273/EE(E)/JED-1/PWD/2025-26
Open Tender
Electrical Works
365 days
Prison Complex Mandoli
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹1.1 L
24 Jan 2026
13 Jan 2026
21 Jan 2026
13 Jan 2026
21 Jan 2026
13 Jan 2026
SH I:- Comprehensive maintenance of EPABX Comprehensive maintenance of EPABX installed in the entire Mandoli Prison Complex. The Comprehensive maintenance will i/e the item telephone exchange rack, POE switch, EPABX server, voice mail system, IP telephones, analog phones, call billing software with standard PC, FCBC (Float Cum Bost Chargers), 10/100 pair SDB, router, 6 KVA online UPS, IG SFP module, LIU, Patch panel, 8 Port media switch, POE injector, media convertor along with all Passive elements like PVC trunking, cables, adapters, RJ-45 Ports, Patch Chords (OFC, Cat-6), pigtails, MCB, MCCB, DIB, Isolators etc as per inventory enclosed. Basis and sr. Technician in a fortnight/ as and when required. Note: The comprehensive maintenance contract (CMC) shall include repair and replacement of all the components of inventory enclosed during the CMC period.
SH II:- EI Works Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group A
Group C
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
Group A
Group C
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 1.5 sq. mm
6 x 1.5 sq. mm
3 x 4 sq. mm
6 x 4 sq. mm
3 x 6 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following size/ modules, GI/PVC box alongwith modular base & cover plate for modular switches in recess etc. as required.
6 Module (200mmX75mm)
8 Module (125 mmX125 mm)
12 Module (200 mmX150 mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way , Double door
12 way , Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way (4 + 24), Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Single pole and neutral
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.
125 A, 16 kA,TPMCCB
250 A, 35 KA,TPMCCB
Supplying, Installation, Testing and commissioning of CAT6 Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc. complete as required.
Supplying and fixing Patch Cord of Optical Fiber Multi Mode or Single Mode LC to LC Fiber Duplex having high precision ceramic ferrule with good concentricity, Fiber corning single mode G652D, Cable Type 2mm with Mechanical specification Apex Offset < 50 μm, Fiber Height + 100 nm, End-face radius of Curvature 7mm < R <25mm, Repeatability < 0.2 db, Working ambient Temperature – 5 0C to +50 0C, Storage Temperature – 10 0C to +50 0C, Length -- 2meter, Type -- LC-LC Duplex etc complete as required.
Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required. 1 run of cable
Supplying and drawing following core Fiber Optic Cable having corrugated steel armoring. The Fiber should be SM Fiber Central -loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-REC G.652D and Telecordia GR-20-core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature should be – 5 0C to +50 0C and Storage Temperature shall be – 5 0C to +50 0C, Max Attenuation ± 0.36 (db / km) at Operational Wavelength 1310 nm and ± 0.22 db / km at Operational Wavelength 1550 nm. type of fiber should be 9/125 / G.652D & Refractive Index should be 1.4670/1.4675. The value for Mode-filed, Cladding Diameter 9.2 ± 0.4 μm and 125 ± 0.7 μm correspondingly. The Dispersion value < 3.5 < 18 ps/nm-km and PMD value < 0.2 ps/km and Cable Cutoff wavelength < 1260 nm i/c splicing & marking etc complete as required. Single Mode 6 Core Optical fiber cable
Supplying, Installation Testing and Commissioning of Standalone router compatible for 19" rack mountable 1U, should have 8 GB RAM/DRAM or more and 8 GB Flash memory or more to support multiple software images for backup purposes, log report, route table etc for smooth functioning of the device and future scalability., hot swappable Redundant Power Supply, having minimum support minimum 06 x 1/10 G Ports & SFP / SFP+ Modules from day 1 (loaded with minimum 2 x 01 Gbps SM / MM SFPs from Day 1), flexibility to support both Metro- Ethernet and IP/MPLS features, OSPF, IS-IS, BGP, PIM-SM, NGMVPN/Multicast VPN, IGMP, MPLS, L2VPN, EVPN-VXLAN/BGP-EVPN, EVPN with Multi-Homing, L3VPN, Segment Routing, SRv6, BGP-LS/LU, BGP Flow Specification, VPLS, RSVP, BFD, Link and Node protection, 16 ECMP ways/paths, Should support Path computation element. Protocol (PCEP) for controller managed network design, IPv4 Routing, IPv6 Routing Border Gateway Protocol, Intermediate System-to-Intermediate System [IS-IS], Open Shortest Path First [OSPF]), IGMP, PIM SSM, OSPFv3 for IPv6, PTP Transparent and Primary, IEEE 1588v2 boundary clock, should have Wire Rate performance, 500k IPv4 FIB and 256K IPv6 FIB, 8k Multicast routes, 128k MAC, 500 MPLS VRF, 5 label stack depth, support the Traffic Classification using various parameters: IP Precedence, 802.1p, MPLS EXP, DSCP,WRED/LLQ, Priority queuing, Traffic Conditioning: Committed Access Rate/Rate limiting, Q-in-Q, 4k VLAN, Strict Priority Queuing or Low Latency Queuing to support real time application like Voice and Video with minimum delay and jitter, 10k VoQ or 10K Hardware Queues, Support Access Control List to filter traffic based on Source & Destination IP Subnet,Source & Destination Port, Protocol Type (IP, UDP, TCP, ICMP etc.), Port Range, URPF, support IETF Netflow-v9 or sFlow or equivalent feature, multiple multi-level privilege levels for remote access (e.g. console, ssh, telnet, Display of input and output error statistics on all interfaces, Display of Input and Output data rate statistics on all interfaces, PCEP, Secure boot, Zero Touch Provisioning (ZTP), TWAMP and Netconf / RESTConf, telemetry support, latest version of Secure Shell for secure connectivity, support for four groups – history, statistics, alarms and events or Telemetry / SNMP, system history logging functions should be available, operating temperature ranging 0 (or lower) to +40 (or higher) degree centigrade, relative humidity: 10% to 85% non-condensing, Configuration Roll Back to recover the mis-configured Equipment to last good configuration, standard complete with 1 Years Guarantee and software/firmware support etc complete as required.
SH III:- Day to Day Maintenance of RO System Providing following qualified staff for operation & day to day maintenance of various type RO Systems installed in Court Complex at District Courts Karkardooma Delhi i/c day to day cleaning & keeping records etc. complete required at site from 09:00 AM to 05:00 PM on all days excluding Sunday & holidays as per direction of Engineer-in-charge etc. complete as required. a) Technician/ Operator : 1 No. b) Helper/ Khallasi – 1 No.
Less of Account of buy back of following assorted dismantled material Item No. 2 to 17
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.44 MB
BOQ_376709.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid