Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.7 LAccepted-AOC NH 148 B NEAR BABA GHISARAM FILLING STATION VILLAGE PALI MAHENDERGARH 123029 | MAHENDERGARH | MAHENDERGARH | HARYANA | 123029 | L1 | Accepted-AOC accepted | |
| 2 | L2₹25.0 L+₹27,260 (1.10%)Rejected-AOC | L2 | Rejected-AOC rejected | |
| 3 | L3₹25.9 L+₹1.2 L (5.04%)Rejected-AOC | L3 | Rejected-AOC rejected | |
| 4 | Rejected-Technical | - | Rejected-Technical Rejected |
Tender Value
₹21.6 L
EMD Value
₹43,220
Closing Date
3 Jun 2022, 5:00 pmClosed
Executive Engineer
Electrical Division PWD BnR Br. Rohtak.
Providing 100 KVA DG Sets in PHC Balu and PHC Batta under CHC Kalayat in District Kaithal. Recall
2022_HRY_222099_1
PWD/Electrical/82609
Open Tender
Electrical Works
Item-rate/Agreement basic
60 days
Jind
Please refer to tender documents as per DNIT conditions.
3 documents required · 3 mandatory
₹1,000
₹43,220
Yes
11 Jul 2022
19 May 2022
4 Jun 2022
19 May 2022
3 Jun 2022
19 May 2022
Amount
HSR Items
20.89 Designing, Supply & Erection of DG Set of capacity given below with noise controlled devices acoustic of suitable rating, testing and commissioning of diesel generating set, radiator cooled, 3 phase, 4 wire, 50 cycles 415 + (-) 1% volts AC alternator coupled directly through a set of flexible coupling on a common MS fabricated base frame with diesel engine complete with suitable size incoming cable from generator to change over / AMF panel, making 2nd incoming cable connection from transformer, outgoing cable connection from changeover / standard panel, making second incoming cable connection from transformer, outgoing cable connection from changeover / STD panel to incomer of motor starter panel, fenced enclosure with platform for DG Sets complete as per following detailed scope and specifications and directions of Engineer-in-Chief.
The rating should be at 1500 RPM
a) Diesel Engine
b) Alternator
c) Battery 24 V
d) Base Plate
e) Suitable Sqmm suitable core copper cable upto 40 meters
f) Tools, standard Panel
g) Metering set 415 VAC -1 set (Amp. Meter, Volt Meter, ASS, VSS, Phase Indicator, Control Fuse, Frequency Meter, CTs)
h) Metering Set 60 / 5 A /110 V (Amp. Meter, Volt Meter)
i) Overload protection for DC-1 No.
j) Battery Charger 24 V DC
k) Copper Bus Bar of suitable size
l) KWH meter 96 Sqmm size
m) Starting fuse button and key switch 9 on / off
n) Indicating lamps for low lubricated oil pressure, high coolant temperature, set running, load on, DC control and other required accessories complete in all respect to the satisfaction of Engineer-in-Charge
20.89.6 100 KVA DG Sets (Make: - Kirloskar / Greaves Cotton / Cummins / Ruston)
23.22.8 SITC four Pole on Load Manual Change over switch in SS enclosure of following ratings
23.22.8.2 100 Amp. 415 volts
24.1 EARTHING AND LIGHTENING ARRESTOR
24.1.3 Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required
24.1.5 Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode.
24.1.8 Providing and fixing 25 mm x 3 mm G.I. Strip on surface or in recess for connections etc. as required with all labour and material.
24.2 LT Cable
24.2.7 Supply and Erection of suitable compression type brass cable glands for underground cable: -
24.2.7.4 70 Sqmm to 95 Sqmm Cable 3 to 3.5 Core
24.2.8 Supply and Erection of alluminium lugs heavy duty including crimping etc. upto the entire satisfaction of the Engineer-in-Charge of the work
24.5 Miscellaneous Items
24.5.2 Supply and erection of mark double walled corrugated (DWC) HDPE pipe10 Kg/CM2 laid 0.75Mtr. below ground level including digging and refilling of earth including cost of suitable size socket / cuppler for HDPE pipe including the cost of labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of the work.
24.5.2.4 DWC/HDPE Pipe 90/75 mm outer dia / inner dia
24.7 RCC Foundations for DG Set
Providing RCC foundation of M 20 grade (1 Cement: 1.5 Stone aggregate: 3 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @ 50 Kg/cum of concrete contents, concrete cover 50 mm, over a bed of 75 mm thick PCC 1:5:10 of required dimensions as per OEM recommendations to provide leveled surface for placement of the DG set complete in all respect and as per directions of Engineer-in-Charge (Size of foundation assumed = 5.0x1.8x1.0m) Unit: Per Cum Note: As size and dynamic load of DG sets vary from manufacturer to manufacturer, item of DG set foundation have been included on the basis of cubic contents of RCC)
24.7.3 100 KVA DG Set
MR Items
N.S.-1 Supply & erection of underground cable loose in existing pipe or trenches complete in all respect upto the entire satisfaction of Engineer in charge of the work. Make: Havells / Polycab / Grandlay.
70 Sqmm 3.5 core armoured cable
Note: - Foundation size of DG Set should be strictly as per specification approved by department
G.B. Traders
S.S. Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .