GE Kamptee
Garrison Engineer, Military Engineer Services, Kamptee Cantt - 441 001
REPAIRS, CLEANING AND MAINT OF SEWAGE LINE, SEPTIC TANKS, SOAK PITS AND SANITARY FITTINGS, REPIARS TO VARIOUS TYPE OF DRAIN AND OTHER RELATED WORKS IN AREA-I UNDER GE KAMPTEE.
2020_MES_324907_1
8160/E8
Open Tender
Civil Works
Item Rate
270 days
Kamptee
Class E, Cat a (i)
7 documents required · 7 mandatory
₹500
Yes
GE Kamptee
₹20,000
Yes
18 Mar 2020
13 Feb 2020
6 Mar 2020
14 Feb 2020
4 Mar 2020
28 Feb 2020
14 Feb 2020 - 27 Feb 2020
Amount
Blocking up the inlet of Septic tank for 2000 users and pumping out effluent dirty liquid and sludge from sludge chambers / septic tank including settling tank and intercepting chamber etc. up to bottom and collecting sludge and dirty liquid in to closed container and cleaning the septic tank with fresh water. Afterwards opening the inlet of septic tank for re-use and lifting the sludge to out side MD land complete all as specified and directed. Note:- The rates qluoted are deemed to be inclusive of transport required.
All as per item No 1 above but septic tank for 1000 users complete all as specified and directed.
All as per item No 1 above but septic tank for 500 users complete all as specified and directed.
All as per item No 1 above but septic tank for 200 users complete all as specified and directed.
All as per item No 1 above but septic tank for 100 users complete all as specified and directed.
All as per item No 1 above but septic tank for 50 users complete all as specified and directed.
All as per item No 1 above but septic tank for 25 users complete all as specified and directed.
All as per item No 1 above but septic tank for 05 users complete all as specified and directed.
Blocking up the inlet of soakage well for 2000 users and removing of bricks bat out effluent dirty sludge from soakage well including settling tank and intercepting chamber etc. up to bottom and collecting sludge and bricks bat in to closed container and cleaning the soakage well with fresh water. Afterwards opening the inlet of septic tank for re-use and lifting the sludge to out side MD land (the rates quoted are deemed to be inclusive of transport required) complete all as specified and directed. Note:- Re-filling of brick bats in Soakage well to be measured separately in item No 22 below.
All as per item No 9 above but soakage well for 1000 users complete all as specified and directed.
All as per item No 9 above but soakage well for 500 users complete all as specified and directed.
Taking out sludge including removing blockage and cleaning the sewage line by using bamboos sticks, MS rod or other sticks and revolving the rope inside the sewer between the two man holes for 150mm dia of sewar and cleaning the same by fresh water complete all as specified and directed.
All as per item No 12 above but 200 mm dia users complete all as specified and directed.
Taking out sludge including blockage and cleaning of the MH of any size, description, depth n exc 1.50m each and collection the sludge in closed container and cleaning the man holes with fresh water and reopenning of manholes complete all as specified and directed. Note:- Sludge be lifted and taken to out sides of MoD land as directed by Engr-in-Charge and be inclusive of transport.
All as per item No 14 above but depth exc 1.50m and not exc 3.00m each complete all as specified and directed.
Cleaning of WC/GT/NT and similar kind of blockage including all tools required and making smooth flow of waste water complete all as specified and directed.
Demolition of brick work of any description built in cement mortar including all quoins, arches but excluding pre-cast articles etc complete all as specified and directed.
M&L for brick work with sub class 'B' bricks old size, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
M&L for brick work with sub class 'B' brick, old size brick, one brick thick in honey combing wall as in soak wells etc built in CM 1:4 complete all as specified and directed.
S&F in repair perforated PVC (SWR) pipes 150mm dia single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
M&L for loose filling with broken bricks/brick bats of gauge 40 to 80mm as in soakage pits, soakage well, sockage PVC pipes in trenches etc complete all as specified and directed.
Excavation in trenches not exc 1.5m deep and not exc 1.5m wide in soft/loose soil etc complete all as specified and directed.
All as per item No 23 above, but depth exceeding 1.5m and not exc 3.0 m depth complete all as specified and directed.
Excavation over areas not exc 1.50 m deep and getting out in soft/loose soil complete all as specified and directed.
All as per item No 25 above but exc 1.5m depth and not exc 3m depth complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in hard/dense soil complete all as specified and directed.
Removing excavated material (soil) not exc 50m and deposited where directed at a level not exc 1.5m above the strating point complete all as specified and directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished and reforming benching as required for 150mm internal dia of pipe complete all as specified and directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for 200mm internal dia of pipe complete all as specified and directed.
Demolition and breaking up of drain pipes (salt glazed ware, AC or RCC pipes) set in cement mortar of 150 mm dia complete all as specified and directed.
All as per item No 31 above but 200mm dia complete all as specified and directed.
M&L for concrete bed in PCC 1:3:6 type C2 (using 40mm graded stone aggregate) to drain pipes including packing under and haunching against the sides of the pipes after laying & testing for 150mm dia of pipes complete all as specified and directed.
All as per item No 33 above but 200mm dia complete all as specified and directed.
M&L for SGSW (Grade 'A') drain pipes confirming to IS size 150mm laid in trenches and jointed in CM 1:2 complete all as specified and directed.
M&L for reinforced concrete pipes, class NP2, laid and jointed complete with collar for 200mm internal dia of pipes complete all as specified and directed.
All as per item No 36 above but 300mm dia complete all as specified and directed.
Demolition of cement concrete unreinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed.
M&L for cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation filling, mass concrete complete all as specified and directed.
M&L providing cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) in coping benching, bed plates and the similar including weathering, slightly rounded or chamfered edges and throating as complete all as specified and directed.
M&L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in surface channels and drains complete all as specified and directed.
M&L for RCC type A1,1:1.5:3 (using 20mm graded stone aggregate) as in drains (bottom and side walls) and similar work complete all as specified and directed.
M&L for extra for forming fair finish drain or channel 30cm inner grith in cement concrete using extra cement including forms, moulds mitred/ stopped ends etc complete all as specified and directed.
Add or deduct for each 25mm girth or part there of over under 30cm complete all as specified and directed.
Taking down cement or cement lime plaster, any desription on brick or stone walll, etc including raking out joints hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on brick or concrete surfaces and finishing surfaces even & smooth without using extra cement complete all as specified and directed.
Demolition of reinforced cement concrete of any description not exc 15cm thick complete all as specified and directed.
M&L for precast RCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in manhole covers, perforated drain cover slabs and similar work including form work etc complete all as specified and directed.
M&L for RCC type A1,1:1.5:3, (using 20mm graded stone aggregate) as in slab supported on walls, beams and colmns in floors, roofs, landings, balconies etc complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (horizonal or sloping) fair finished complete all as specified and directed.
Formwork to edges of concrete flats, treads breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roof n exc 20 cm wide and side of RCC/PCC bands in wall, horizontal or sloping and similar work exc 10 cm but not exc 20cm wide complete all as specified and directed.
M&L for TMT bars of 10mm dia and over cut to lengths bent to shape required including cranking, bending spirally for hooking and binding with MS wire (annealed) not less than 0.9 mm dia etc including handles for MH covers etc complete all as specified and directed.
Dismantling of 100mm dia cast iron pipe jointed in cement mortar and taking out of trenches, if required complete all as specified and directed. Note for item Nos 53 & 54:- Rate quoted is deemed to include earthwork excavation.
S&F as in repair (including taking down old one) cast iron soil, waste and vent pipes, 100mm dia in any length with or without ears with cement joinsts, fixed to walls complete all as specified and directed.
S&F fitting for cast iron pipes bends 100mm bore diminishing pieces or trapes (larger bore measured) complete all as specified and directed.
S&F fitting for cast iron pipes branch pieces 100mm bore, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed.
S&F fitting for cast iron pipes sockets (double), collars 100mm complete all as specified and directed.
S&F in repair PVC (SWR) pipes 150 mm dia single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F in repair PVC (SWR) pipes of 110 mm dia single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F in repair PVC (SWR) pipes of 75mm dia complete all as specified and directed.
S&F in repair PVC (SWR) bends with access door any radius, 110 mm dia complete all as specified and directed.
All as per item No 61 above but 75mm dia complete all as specified and directed.
S&F in repair PVC (SWR) branch piece, single (single Y) equal or unequal with access door, 110 mm dia complete all as specified and directed.
S&F in repair PVC (SWR) branch piece, double (double Y) equal or unequal with access door, 110 mm dia complete all as specified and directed.
S&F in repair PVC (SWR) branch piece, single (single Y) equal or unequal with access door, 75 mm dia complete all as specified and directed.
S&F in repair PVC (SWR) branch piece, double (double Y) equal or unequal with access door, 75mm dia complete all as specified and directed.
S&F in erepair PVC (SWR) junction single, (Single T) equal or unequal with access door, 110 mm dia complete all as specified and directed.
S&F in repair PVC (SWR) junction double, (double T), equal or unequal with access door 110 mm dia complete all as specified and directed.
S&F stack clamp made out of 50x5 mm flat iron for 75mm dia of pipe complete all as specified and directed.
All as per item No 69 above but 100 mm dia complete all as specified and directed.
S&F in repairs PVC (SWR) Nahani trap 75mm dia with grating including jointing with solvent cement complete all as specified and directed.
S&F in repairs PVC (SWR) gully trap 125x110 mm including jointing with solvent cement complete all as specified and directed.
S&F in repair vitreous china squatting pan "Orissa" pattern size 630x450mm, white with integral foot rests including connection to trap and to flushing pipe anti-syphonage pipe etc complete including provn of lime concrete bedding and making good to floor (excluding flushing cistern and flush pipe) complete all as specified and directed.
S&F in repair vireous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including PVC cover complete all as specified and directed.
S&F in repair health faucet with 1 mtr tube & hook (braded Tube) of Make: Prayag Cat No BEA 81 complete all as specified and directed.
S&F in repair Jet Spray (Butterfly) with 1 mtr tube of Make: Prayag Cat No BEA-17 complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding, but not backing, removing serviceable tiles to store and rubbish off the premises up to 1 KM complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.06sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles including 15mm thick screed bed or bedding layer in CM 1:4 finished fair and even for laying floor finishes/tiles etc complete all as specified and directed.
M&L for glazed ceramic coloured tiles (300mm x 450mm) on vertical surface such as skirtings /dados set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10mm thick backing coat in CM 1:4 finished even and fair complete all as specified and directed.
Taking up or down GI tubing and connection of 15mm bore complete all as specified and directed.
Taking up or down GI tubing and connection of 20mm bore complete all as specified and directed.
Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring, etc and making good, cutting not exc 10cm girth complete all as specified and directed
S&F GI tubing 15mm bore medium grade with all fittings and fixed to wall complete all as specified and directed.
All as per item No 83 above but 20 mm bore complete all as specified and directed.
S&F in repair vitreous china urinal, half stall type, white (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and directed.
S&F CP brass urinal spreader for fixing with 15mm dia pipe complete all as specified and as directed.
S&F in repair plastic water closet seat cover, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S&F in repair 10 ltr capacity PVC valve less syphonic action type flushing cistern low level, white with inlet ball valve float and handle including bracket etc complete all as specified and directed.
Supply only flush pipe of polythene of low or high density 32 mm PVC for low level flushing cistern complete all as specified and directed.
S&F in repair bib tap 15mm dia, cast copper alloy CP with crutch or butter fly handle screwd for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair low density PVC pipe 32mm dia as in waste pipe to sink complete all as specified and directed.
S&F in repair low density PVC pipe 40 mm dia as in waste pipe to sink complete all as specified and directed.
S&F in repair low density PVC pipe 50 mm dia as in waste pipe to sink complete all as specified and directed.
S&F in repair 15mm bore ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S&F in repair 20mm bore ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S&F in repair 25mm bore ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
NOTE:- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs.13,750.00]
M/s T.S.JOHAR
M/s Rahul Traders
NORTH INDIA PEST CONTROL
M/s M.G. Hargunani
DE PRETTY AND CO
Meet Road Lines
DEESHA CONSTRUCTIONS
M/s DS Khekde
Bidder Name
Meet Road Lines
DE PRETTY AND CO
SHUB CONSTRUTION
M/s T.S.JOHAR
DEESHA CONSTRUCTIONS
M/s Rahul Traders
M/s DS Khekde
M/s M.G. Hargunani
NORTH INDIA PEST CONTROL
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .