Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹43.0 L+₹3.6 L (9.05%)Rejected-Finance | L2 | Rejected-Finance Not Being Lowest Bidder | |
| 3 | L3₹46.9 L+₹7.6 L (19.2%)Rejected-Finance | L3 | Rejected-Finance Not Being Lowest Bidder | |
| 4 | Rejected-Technical | - | Rejected-Technical Not approved as firm is not enlisted in appropriate category i.e a (i) |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
13 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
PROVN OF CERTAIN MINOR WORKS, REVENUE WORKS AND LBW WORKS AT VARIOUS LOCATIONS UNDER GE E/M LUCKNOW
2021_MES_410550_1
GE/EM/LKO/HOSP/T-81 OF 2020-2021
Open Tender
Miscellaneous Works
Item Rate
240 days
Lucknow
Class D or above category a (i), b (i)
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹90,000
Yes
10 Mar 2021
7 Jan 2021
15 Feb 2021
7 Jan 2021
13 Feb 2021
1 Feb 2021
60 days
Amount
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep & getting out in soft/loose soil including removal of surplus spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 meter above the starting point, complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes line ,foundation, manhole etc. and getting out including trimming the sides and forming bottom surfaces foundation, manholes etc to required levels in soft/loose soil , complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point , complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the cables have been laid and tested, complete all as specified and directed by Engineer-in-Charge.
Broken bricks for hardcore of gauge nexc 63 mm, deposited, spread and levelled in layers nexc 15 cm thick watered and rammed to true surface , complete all as specified and directed by Engineer-in-Charge.
Plain cement concrete (1:5:10), type E-2, using 40 mm graded mechanically crushed stone aggregates as in foundations filling and mass concrete or in sub base to floor, complete all as specified and directed by Engineer-in-Charge.
Plain cement concrete (1:4:8), type D-2, using 40 mm graded mechanically crushed stone aggregates as in foundations filling, bed of manhole and mass concrete or in sub base to floor, complete all as specified and directed by Engineer-in-Charge.
Plain cement concrete1:2:4 type D2 ,using 20 mm graded mechanically crushed stone aggregates as in foundation, filling & mass concrete, for hard standing etc complete all as specified and directed by Engineer-in-Charge.
Plain Cement Concrete 1:2:4 ,type B1 ,using 20 mm graded mechanically crushed stone aggregates as in roof kerb, mud stops, channel/ benching of manhole laid to shape and slope surface finished even and smooth using extra cement including necessary formwork rounded or chamfered on edges , complete all as specified and directed by the Engineer in Charge.
Plain cement concrete 1:3:6 type C2 ,using 40 mm graded mechanically crushed stone aggregates 75 mm thick, finished fair and even with using extra cement , complete all as specified and directed by the Engineer in Charge.
Plain cement concrete (1:4:8), type D-2, using 40 mm graded mechanically crushed stone aggregates 75mm thick as in sub base to floor, complete all as specified and directed by Engineer-in-Charge.
Plain cement concrete (1:4:8), type D-2, using 40 mm graded mechanically crushed stone aggregates as in sub base 100 mm thick , complete all as specified and directed by the Engineer in Charge.
Plain cement concrete type C1 (1:3:6), using 20 mm graded mechanically crushed stone aggregates,75 mm thick , as in path / plinth protection/paving laid in slope in 1:30 in panels n exc 2m long concrete surfaces finished even and smooth without using extra cement including making joints between panel to panel and filling the same with bitumen mastic bitumen & sand mixture in a ratio 1:3 , complete all as specified and directed by the Engineer in Charge.
Plain cement concrete (1:2:4) type B-1 using 20mm graded mechanically crushed stone aggregates as in coping,padding and bed block, wall through and the like including weathering slightly rounded or chamfered angles and throating including necessary form work ,complete all as specified and directed by the Engineer in Charge.
Treating the back fill in contact with foundation at the rate of 7.5 litre of emulsion per Sqm of verticle surface (area of the sub structure in contact with back fill to measured) , complete all as specified and directed by Engineer-in-Charge.
Treating the top surface of filled earth at the rate of 5 ltr if emulsion per sqm of surface, complete all as specified and directed by Engineer-in-Charge.
Treating the soil under plinth protection at the rate of 5 litres of emulsion per square of surface area , complete all as specified and directed by Engineer-in-Charge.
Treating soil along with external perimeter of building at the rate of 2.25 ltrs of emlution per meter of the perimeter wall , complete all as specified and directed by Engineer-in-Charge.
Reinforced Cement concrete M-25 ( design mix) using 20mm graded mechanically crushed stone aggregates as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under reamed piles and mass concrete , complete all as specified and directed by Engineer-in-Charge.Note: Steel reinforcement shall be measured and paid for separetely.
Reinforced Cement concrete M-25 ( design mix) using 20mm graded mechanically crushed stone aggregates as in slabs supported on wall beam and column in floor slabs and roofs landing deck slabs and in shelves, complete all as specified and directed by Engineer-in-Charge. Note: Steel reinforcement shall be measured and paid for separetely.
Reinforced Cement concrete M-25 ( design mix) using 20mm graded mechanically crushed stone aggregates as in chajjas and the like, complete all as specified and directed by Engineer-in-Charge. Note: Steel reinforcement shall be measured and paid for separetely.
Reinforced Cement concrete M-25 ( design mix)using 20mm graded mechanically crushed stone aggregates as in beams, cantilevers, bressumers, lintels over 1.5 m span , complete all as specified and directed by Engineer-in-Charge. Note: Steel reinforcement shall be measured and paid for separetely.
Reinforced Cement concrete M-25 ( design mix) using 20mm graded mechanically crushed stone aggregates as in columns, pillars, piers, posts ans stuts , complete all as specified and directed by Engineer-in-Charge. Note: Steel reinforcement shall be measured and paid for separetely.
Use & waste of form work to soffits of suspended slab of concrete such as roof slabs, floor slabs, cover slab, shelve, landings and similar works n.exc 200 mm thick (horizontal or sloping); with rough finished surfaces of concrete flat surface, complete all as specified and directed by the Engineer in Charge.
Use & waste of form work to edges of concrete flats, roof exc 5 cm wide and n exc 10 cm wide for rough finished surfaces, complete all as specified and directed by the Engineer in Charge.
Use & waste of form work to sides and soffits of floor or roof beams, beam haunchings, girders,bresumers, lntels, cantilevers, shelves including supports, overhangs, chajjas etc. also splays between floors and beams etc., surfaces finished fair in forms , complete all as specified and directed by the Engineer in Charge.
Use & waste of form work to sides of Square, rectangular or polygonal pillars, posts, struts, piers, columns and stanchions surfaces finished fair , complete all as specified and directed by the Engineer in Charge.
Use & waste of form work to chajjas and similar work for fair finished concrete surface , complete all as specified and directed by the Engineer in Charge.
Mild steel TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire ( annealed) not less than 0.90 mm dia. or higher , complete all as specified and directed by the Engineer in Charge.
Mild steel TMT bars 10 mm dia and over as in reinforcement cut to length , bent to shape required, including cranking, bending spirally for hooping ends for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.90 mm dia, complete all as specified and directed by the Engineer in Charge.
Mild steel TMT bars 5mm dia. and over up to and including 10 mm dia. in stirrups, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire ( annealed) not less than 0.90 mm dia. Or securing with clips , complete all as specified and directed by the Engineer in Charge.
Brick work with sub class 'B' Fly ash bricks, straight or curved on plan exceeding 6m mean radius, as in one brick thick walls, built in CM (1:6), complete all as specified and directed by Engineer-in-Charge.
Rendering 15mm thick on brick wall or concrete surface in cement mortar 1:4 finished even and smooth without using extra cement using with and including integral water proofing compound 2 % by weight of cement ,complete all as specified and directed by Engineer-in- Charge. Note:- Supply of WPC shall be measured & paid separately.
Rendering 15mm thick on fair faces of brick wall or concrete surface in cement mortar 1:6 finished even and fair complete all as specified and directed by Engineer-in- Charge.
Rendering 15mm thick on brick wall or concrete surface in cement mortar 1:4 finished even and fair without using extra cement complete all as specified and directed by Engineer-in- Charge.
Rendering 5 mm thick on ceiling in cement mortar 1:3 finished fair and even without using extra cement ,complete all as specified and directed by Engineer-in- Charge.
Rendering 10mm thick fair faces on brick wall or concrete surface in cement mortar 1:4 finishing the surface fair & even with 3 mm thick setting coat with CM 1:2, complete all as specified and directed by Engineer-in- Charge.
Rendering 10mm thick on brick wall or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed by Engineer-in- Charge.
Preparation of newly plastered or unplastered surfaces of walls by brooming down and priming plastered and other surfaces with with two coats of cement base paint over a coat of cement base primer including ,complete all as specified and directed by Engineer-in- Charge.
Preparing surfaces, plastered or unplastered new surfaces of ceiling and applying three coats white wash all as ,complete all as specified and directed by Engineer-in- Charge.
First quality glazed ceramic coloured tiles of 350x250x7/450x350x7 mm thick, laid on vertical surfaces such as skirting, dados and risers to steps etc laid over and including 10mm thick cement plaster in CM (1:3) set and jointed in neat cement paste of honey like consistancy and pointed in white or coloured cement to match the shade of tiles, complete all as specified and directed by Engineer-in- Charge.
First quality, Non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sq.m but not exceeding 0.18 Sq.m, laid in floors with neat cement slurry @ 3.00 kg/Square Metre over and including 15 mm thick screed bed of cement mortar (1:6) including pointing in coloured cement to match the shade of tiles , complete all as specified and directed by Engineer-in- Charge.
Granite stone slab ( Black colour) 18-20 mm thick, work (table rubbed and polished and grinding) as in flooring including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including screed bed of 15 mm thick in CM 1:6, complete all as specified and directed by Engineer-in- Charge.
20mm thick Granite(of any type) tiles machine cut in skirting/dado laid over cement screed and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing complete all as specified and directed by Engineer-in-Charge.
60mm thick PCC intelocking tiles (rubber laminated finish) of size and shape as approved, laid dry over and including sand not less than 40 mm thick, interstices filled in floors/pathway ,complete all as specified and directed by the Engineer in Charge.
Coloured / designed as approved floor tiles 10 to 20 mm thick area of each tile exc 0.09 sqm but n.exc 0.20 sq m in floor surface set and jointed in neat cement slurry and pointed in white/colured cement and pigment to match over 15 mm thick CM 1:4 complete all as specified and directed by Engineer-in-Charge.
Factory made solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplied and fitted as per specification & drawing and as per manufacturer's instructions and shown on drawing on Page 160 of SSR Pt-II ,complete all as specified and directed by the Engineer in Charge.
Factory made solid panel PVC Door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail,lock rail and bottom rail on either side as gap insert for top rails, bottom rail,panelling of plain colour PVC sheet to be fitting in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supply & fixing in the frame at site as per specification and drawing on Page No 156 of SSR Part-II Rates,complete all as specified and directed by the Engineer in Charge.
Butt hinges 100 mm size ,extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed type B21 ,complete all as specified and directed by the Engineer in Charge.
Aluminum anodizes barrel tower bolts of extuded section and fixed of 200 mm long size (length of bolt), complete all as specified and directed by Engineer-in-Charge
Extruded aluminium alloy handles of size 125 mm, fabricated type anodized ,complete all as specified and directed by Engineer-in- Charge.
Aluminum alloy, anodized, sliding door bolt with hasp staple ( bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy and fixed length of bolt 250mm, bolts not less than 12mm dia with and including a minimum of 6 bolts not,four on bolt plate and two on staple plate complete (ISI marked ) , complete all as specified and directed by Engineer-in-Charge.
Aluminium Anodised ventilator curved shape fixed with reflective type glass aluminium section weighing 0.55 Kg/m incl necessary joining cleats, glazing clips rubber neosperene at bottom pannel and top panel with wire cloth of 0.46 nominal dia of wire and average width of aperature 1.4 mm ,complete all as specified and directed by Engineer -in-charge.
Aluminium Anodised grill 6mm dia not less than 4 Kg per sqm fixed with frame in windows/ventilator , complete all as specified and directed by Engineer -in-charge.
Aluminium Anodised power coated anodised Aluminium alloy sections sliding windows shutters with frames comprising Series -C (20mm), 2 track sliding shutters duly fitted with neoprene beading, glazing clips,locking device, heat absorbing glass 4.8 mm nominal thicknes , complete all as specified and directed by Engineer -in-charge.
Aluminium Anodised door frame with shutter, incl necessary joining cleats, glazing clips rubber neoprene packing , Handle 2 Nos in each door, 4 Nos 100mm hinges, 1 Nos 200mm aluminium anodised tower bolt anodised aluminium snap beading screw ecessary locking arrangement with mortice lock with duplicate ,complete all as specified and directed by Engineer -in-charge.
Steel water tubeing, 15 mm bore medium grade, galvanized with all fittings and fixed complete to walls, ceiling or laid in floors , complete all as specified and directed by Engineer-in- Charge.
Steel water tubing, 20 mm bore medium grade, galvanized with all fittings and fixed complete to walls, ceiling or laid in floors ,complete all as specified and directed by Engineer-in- Charge.
Vitreous china squatting pan Orissa pattern size 580x440mm white with integral foot rest, with front or back inlet with integral foot rests including connections to trap, and to flushing pipe, antisyphonage pipe, etc (excluding flushing cistern and flush pipe) including Cast Iron 'P' or 'S' trap of 100mm size fixed in PCC 1:2:4 type B-2 and necessary lime concrete, including making good the surface to match with existing floor finish ,complete all as specified and directed by the Engineer in Charge.
Vitreous china wash down water closet pan (padestal pattern) with P or S trap white including fixing with bolt in floor with and including 10 litre capacity low level flushingcistern and flush pipe connecting to WC with cistern with and including plastic water closet seat, white closed pattern with flat bottom and cover and mild steel chromium plated hinging device with and including CP spray jet and fixing , complete all as specified and directed by the Engineer in -Charge
Health faucet CP with 15 mm dia minimum 900 mm long pipe and hanging hook, complete all as specified and as directed by Engineer-in- Charge.
Brass chromium plated shower rose without swivel joints , any size, including fixing to steel pipe or union fixed , complete all as specified and directed by the Engineer in -Charge
Wash basins, vitreous china, white, flat back of size 550x400 mm including brackets and cutting for and pinning in ends in brackets or erecting stand ,32mm dia waste fittings, brass, chromium plated with long screwed shanks and fly nuts, 32mm dia HDPE waste pipe and including new M S brackets including waste coupling of PTMT (half or full threaded) for 32/40mm dia fixed ,complete all as specified and directed by Engineer-in- Charge.
Vitreous China bowl urinal flat back, size of 465x355x265 mm White ( minimum), with grating and union for discharge pipe ( excluding flushing cistern, flush pipe , and waste pipe) , including connections to flushing pipe and outgoing pipes , complete all as specified and directed by Engineer -in-charge.
Pillar taps, fancy type cast copper alloy , with capstan heads, chromium plated , screwed down for 15 mm bore pipe,high pressure , with or without l'ettered ' 'HOT' or 'COLD' with long screwed shanks and fly-nuts , screwed for iron pipe fixed, complete all as specified and directed by the Engineer in -Charge
Stop valve chromium plated concealed type ISI Marked, , cast copper alloy fancy type, with long shank and cup, with capstan head and cup screwed both ends for iron pipe or for union and fixed , complete all as specified and directed by the Engineer in -Charge
Brass Tubular towel rod 20 mm dia D type chromium plated, of 24" (60 cm long), complete all as specified and directed by the Engineer in -Charge
Chromium plated fancy type Bib taps, cast copper alloy with crutch handle, screwed for 15 mm bore dia. iron pipe or for brass ferrule , complete all as specified and directed by the Engineer in -Charge
PVC valveless , syphonic action type flushing cisterns 10 ltrs capacity , low level , white, with inlet ball valves , float and handle including brackets and pvc flush pipe 32 mm dia for low level, complete all as specified and directed by the Engineer in -Charge
Angle stop cock chromium plated , fancy type screwed down for 15 mm bore dia. pipe, high pressure, with crutch handle , screwed externally both ends for unions etc. and fixed , complete all as specified and directed by the Engineer in -Charge
PVC connection of PTMT ,non corrosive with nuts and washers on both ends,450mm long suitable for 15 mm bore fixed , complete all as specified and directed by the Engineer in -Charge
Grating doom CP 100mm dia of plated with waste hole/without hole as required fixed ,complete all as specified and as directed by Engineer-in- Charge.
Counter shaped wash basin (WHB) oval shaped including all fittings i.e. waste pipe & cp waste coupling ,complete all as specified and directed by the Engineer-in-Charge. Make- CNS-WHT-705 of Jaquar or other make specified in appx of make.
Bib cock 15mm dia with wall flange, complete all as specified and directed by Engineer-in-Charge. Make- Cat no OPP-CHR-15037PM of Jaquar or other make specified in appx of make.
Single lever basin mixer ,complete all as specified and directed by Engineer-in-Charge. Make- Cat no ORP-CHR-10011BPM of Jaquar or other make specified in appx of make.
Wall mixer , complete all as specified and directed by Engineer-in-Charge. Make- Cat no QQT-CHR-7215 of Jaquar or other make specified in appx of make.
CP angle cock (One way) with wall flange ,complete all as specified and directed by Engineer-in-Charge. Make- Cat no OPR-CHR-15053PM of Jaquar or other make specified in appx of make.
Vitrious china padestal water closet(EWC) , icluding jet sprey,flushing cistern & seat cover ,complete all as specified and directed by Engineer-in-Charge. Make- Cat no Cat No.-CNS-WHT-753SN ofJaquar or other make specified in appx of make.
CP Towel Ring sqaure ,complete all as specified and directed by Engineer-in-Charge. Make- Cat No.-AKP-CHR-35721P of jaguar or equivelent make other make and model of Kholar/plumber.
CP soap dish ,complete all as specified and directed by Engineer-in-Charge. Make- Cat No.cat no.AEC-CHR-1131 of jaguar or equivelent make other make and model of Kholar/plumber
PVC (SWR) pipes 110mm bore single socketed in any length with ruber rings joints laid in trenches or in floors ,complete all as specified and directed by Engineer-in- Charge.
PVC (SWR) pipes 75mm bore single socketed in any length with ruber rings joints laid in trenches or in floors ,complete all as specified and directed by Engineer-in- Charge.
PVC (SWR) floor trap, plain with grating 75 mm dia including jointing with solvent cement ,complete all as specified and directed by Engineer-in- Charge.
PVC ( SWR) junction single , ( Single T) equal or unequal with access door ,110 mm bore ,complete all as specified and directed by Engineer-in- Charge.
PVC ( SWR) junction single , ( Single T) equal or unequal with access door ,75 mm bore ,complete all as specified and directed by Engineer-in- Charge.
PVC (SWR) pipes 110mm bore single socketed in any length with ruber rings joints fixed to walls with necessary brackets ,complete all as specified and directed by Engineer-in- Charge.
PVC (SWR) pipes 75mm bore single socketed in any length with ruber rings joints fixed to walls with necessary brackets ,complete all as specified and directed by Engineer-in- Charge.
PVC (SWR) vent cowl 110 mm bore ,complete all as specified and directed by Engineer-in- Charge.
PVC (SWR) vent cowl 75 mm bore ,complete all as specified and directed by Engineer-in- Charge.
PVC (SWR) bends any radius 110mm bore fixed ,complete all as specified and directed by Engineer-in-Charge.
PVC (SWR) bends any radius 75mm bore fixed ,complete all as specified and directed by Engineer-in-Charge.
Rotational moulded PVC, double layered, water storage tanks of capacity 500 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position, with & including all fittings such as GI tank nipple etc. but excluding ball valve ,complete all as specified and directed by Engineer-in- Charge.
Rotational moulded PVC, double layered, water storage tanks of capacity 1000 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position, with & including all fittings such as GI tank nipple etc. but excluding ball valve ,complete all as specified and directed by Engineer-in- Charge.
Ball brass valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 210 gms complete , screwed for 20 mm bore dia. pipe or brass ferrule ,complete all as specified and directed by Engineer-in- Charge.
Gun-metal, globe or gate valves 15mm dia , with iron wheel head, screwed both ends for iron pipe and fixed to 15mm dia GI tube, complete all as specified and directed by Engineer-in- Charge.
Gun-metal, globe or gate valves 20mm dia , with iron wheel head, screwed both ends for iron pipe and fixed to 20mm dia GI tube, complete all as specified and directed by Engineer-in- Charge.
Water proofing treatment on roof surfaces to the following specification:- (a) 15mm thick screed plaster on RCC slab CM 1:4 with using in and including liquid water proofing compound @ 3% by weight of cement. (b) Applying oil bound bitumen primer @ 0.40 lit / Sqm of density 0.87 - 0.89 Kg/lit of 25º C after preparation of the surfaces. (c) Supply and laying 3mm thick APP water proofing membrane reinforced with non woven polyster matt laid using butane torch by torch on application with a side lap of 10cm and 15cm end lap weighing not less than 3.5 kg/sqm. (d) Providing 230 x 115 x 40mm thick machine pressed brick tiles with minimum thickness of joint (n.exc 3mm) and are throughly filled with water proof polymer based joint mortar , complete all as specified and directed by Engineer-in-Charge. (Note : The tiles shall be laid to the slop to avoid stagnation of water).
Salt- glazed stoneware drain pipe grade ‘A’ 150 mm bore, ISI marked jointed with cement mortar, laid in trenches and tested including pipe fittings such as bend, junction etc. of same grade, complete all as specified and directed by the Engineer-in-Charge.
Plain cement concrete 1:4:8, type D-2,using 40mm graded mechanically crushed stone aggregates as in bed to drain pipes of 150mm bore including packing under and haunching against the sides of pipes after they are laid and tested, complete all as specified and directed by the Engineer-in-Charge.
Plain cement concrete (1:2:4) type B-1 using 20mm graded mechanically crushed stone aggregates as in surface channels, drain channel, drain benching of manholes, laid to shape & slope, surfaces finished even and smooth using extra cement including necessary form work etc , complete all as specified and directed by the Engineer-in-Charge.
Extra for forming fair finishing drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds, mitered /stopped ends etc , complete all as specified and directed by the Engineer-in-Charge.
Providing pre-cast reinforced cement concrete1:2:4 type B-1, using 20 mm graded mechanically crushed stone aggregates set in cement mortar 1:4 as in manhole covers including necessary forms/moulds, complete all as specified and directed by the Engineer-in-Charge.
Cutting into walls of existing manholes for connecting new drain pipe 150 mm dia bore, making good to wall in CM (1:3)/ PCC (1:2:4) after inserting pipe, cutting out benching & forming branch channel (1/2) round or (3/4 section) in cement concrete (1:2:4) type B-1, reforming benching as required and rendering smooth finished, including removal of rubbish outside MoD land, complete all as specified and directed by the Engineer-in-Charge.
Excavation in post holes (or similar holes) each not exc. 0.5 Cubic Metre and getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exc. 25 cm, watering and removing surplus spoil to a distance not exc. 50 m and making good surface in soft / loose soil , complete all as specified and directed by Engineer-in-Charge.
Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy brackets framing (Beams, Tee, angle, channel or flat section) including distance pieces, cleats etc. of Fe 410- W (Gde- E-310) Quality A ,complete all as specified and directed by Engineer-in-Charge.
Steel work in tubular trusses including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1998 grade St- 240, complete all as specified and directed by Engineer-in-Charge.
Rolled Mild Steel Plates of any size (plain or Chequered) 5mm thick over in thickness in available sizes confirming to Fe 410 - W (Grade E-250 quality-A) , complete all as specified and directed by Engineer-in-Charge.
M S work as Framed works such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes,framed guard bars barred iron doors ladders, framed balusters walk ways railing, framed work of water tanks, framed and hung as gates including pintle hinges, stops, hand made sliding sliding bolts etc ,cdrilling bolting or reveting etc and similar work conforming Fe-290 Gde E-165 ,complete all as specified and directed by Engineer-in- Charge.
Rolled mild steel in framed work as in doors or gates of angle or other section with gusset plates, rails, braces,etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc., to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings ( exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing ,complete all as specified and directed by Engineer-in- Charge.
Preparing new steel surface of any description, over 10cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer , complete all as specified and directed by Engineer-in-Charge.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheeting 0.50 mm thick made to any shape or semi-ciruclar any colour having tensile strength of 550 Mpa as in roof covering/ cladding complete with tapping screw complete all as specified and directed by Engineer-in-Charge.
Point wiring for one socket outlet point 5 amps on independent board controlled by one, one way switch by using 1.5 Sq mm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including PVC concealed conduits and conduit accessories/fittings, pressed steel terminal switch boxes, 3 mm thick Bakelite sheet top cover (ISI Marked) fitted with Chromium plate brass screws washers and 1.5 Sq mm nominal cross sectional area multistranded copper conductor green PVC insulated unsheathed earth wire and connecting to earth dollyand making good disturbed surfaces of walls, floors, etc. to match with the existing specification of walls, floors etc. ,complete all as specified and as directed by Engineer-in- Charge.
Point wiring for one light/fan point controlled by one, one way switch by using 1.5 Sq mm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including PVC concealed conduits and conduit accessories/fittings, pressed steel terminal switch boxes, 3 mm thick Bakelite sheet top cover (ISI Marked) fitted with Chromium plate brass screws washers and 1.5 Sq mm nominal cross sectional area multistranded copper conductor green PVC insulated unsheathed earth wire and connecting to earth dolly and making good disturbed surfaces of walls, floors, etc. to match with the existing specification of walls, floors etc. ,complete all as specified and as directed by Engineer-in- Charge.
Switch piano flush type , single pole , 5/6 Amps, one way polycarbonate type ,complete all as specified and directed by Engineer-in- Charge.
Socket out let 2 in 1 multipurpose 3 pin , (5 Amps ) flush type and 2 pin 5 Amp controlled by one switch polycarbonate type ,complete all as specified and directed by Engineer-in- Charge.
Ceiling rose, Pilot 3 Plate ceiling rose 6A ,complete all as specified and as directed by Engineer-in- Charge.
Supply, installation, testing and commissioning of evaporative desert coolers (steel body) factory made 22 gauge PGI sheet of size 100x70x60cm appx , front and side panels are made of same gauge with wood wool pads having nominal air flow capacity of 4000 cfm, or nearest size,having exhaust fan motor of capacity 1/5 HP with 18” steel blade size, and submersible pump of capacity 1/60 HP, and powder coated including necessary arrangement for connecting to new or existing source of water supply line with all fittings and fixtures complete all as specified and as directed by Engineer-in- Charge. Make-Champion or equivalent. Make of Exhaust Fan-Crompton Greaves, Havells, BAJAJ, KHAITAN, Make of submersible pump-BAJAJ, SYMPHONY, ORIENT, KHAITAN
Fabrication of mild steel stand made out of MS angle iron and flat grade Fe-290-Gde E-165 of size as directed suitable for positioning the desert cooler / stablisers including painting with two coat of (black) enameled paint over a coat of red oxide primer and installed at locations ,complete all as specified and as directed by Engineer-in- Charge.
Supplying and laying or fixing, jointing and testing LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 6 sqmm cross sectional area, 2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers complete all as specified and as directed by Engineer-in- Charge. Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items.
Bricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection, complete all as specified and as directed by Engineer-in- Charge.
Sand cushioning to cables with a layer of sand 8 cm deep before laying the cable and 15 cm depth (punned down to 10 cm depth after laying and stretching of cable), complete all as specificed and directed by Engineer-in-Charge. Note: Punned thickness (over all 18 cm) shall be measured & paid.
Supply, installation, commissioing and testing inverter type split Air Conditioner, inverter type HOT&COLD,electric driven , electric driven, capacity 1.8 TR with steady cool compresser all star,Nano titanium filter ,auto clean function ,indoor sound level 32 DB,front panel display, wireless LCD remote, precoated aluminium fins,477 cfm air circulation, auto fan speed, suitable for working on 230 volts, single phase, 50 Hz supply ,complete including cutting of wall, providing stand for out door unit and making good disturbed surface of wall etc and remote operation , complete all as specificed and directed by Engineer-in-Charge. Note- Extra length of copper pipe, drain pipe and Main lead required is deemed to be included in the quoted rate and will be provided by the contractor without any extra cost.
Supply, installation, commissioing and testing inverter type split Air Conditioner, inverter type HOT&COLD,electric driven , electric driven, capacity 1.5 TR with rotary compresser,Nano titanium filter ,auto clean function ,indoor sound level 32 DB,front panel display, wireless LCD remote, precoated aluminium fins,477 cfm air circulation, auto fan speed, 5 star, electric driven suitable for working on 230 volts, single phase, 50 Hz supply ,charging of referigerant gas after necessary brazing /fixing of both indoor and out door unit and testing ,insulation of both the copper pipe with insulsting material omplete including cutting of wall, providing stand for out door unit and making good disturbed surface of wall etc and remote operation , complete all as specificed and directed by Engineer-in-Charge. Make:- HITACHI/DAIKIN/BLUE STAR/ VOLTAS. Note- Extra length of copper pipe drain pipe and Main lead required is deemed to be included in the quoted rate and will be provided by the contractor without any extra cost.
Plug and socket DBs with Single pole MCB rated 32 Amps capacity with socket plug top 2 pin and earth plug complete all as specified including making good disturbed surface of wall and mounted flush , complete all as specificed and directed by Engineer-in-Charge.
Voltage stabilizer automatic boost/buck transformer for low and high voltage with electronic transistorised relay/time relay for two min, SP 50 HZ with volt meter indicator and input voltage 140 to 280 and cut up voltage 215 to 240 V cap 4 KVA , complete all as specificed and directed by Engineer-in-Charge.
Voltage stabilizer automatic boost/buck transformer for low and high voltage with electronic transistorised relay/time relay for two min, SP 50 HZ with volt meter indicator and input voltage 140 to 280 and cut up voltage 215 to 240 V cap 5 KVA , complete all as specificed and directed by Engineer-in-Charge.
Mild steel galvanized tubes light grade ISI marked 40mm bore laid in trenches / road crossing/ fixed to pole /walls/path/drain /floor etc ,complete all as specified and as directed by Engineer-in- Charge.
Sub main wiring (concealed type ) with two single core 6 Sqmm FRLS PVC insulated and unsheathed 1100 volts grade cables with stranded copper conductor cable drawn through in and including 25 mm dia rigid non metallic PVC conduit and conduit accessories including one single core 6 Sqmm FRLS PVC insulated unsheathed stranded copper earth cable connected to common earth dully complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface, complete all as specified and directed by Engineer-in-Charge. Note : (i) 2 run of 6 Sqmm ,1 run of PVC conduit & 1 run of 6 Sqmm cable will be measured as single run.(ii) Extra length of cables/wire required for connection to MCBs shall not be measured and paid separetly the rate quoted by contractor per unit shall be deemed to be included in the quoted rate of this item.
Distribution box epoxy powder coated ,SPN 4 way, 240 V, with 200 amps rated bus bar, 240 Volts for MCBs, grouted flush to walls complete with IP 43 and metal double door ,complete all as specified and directed by Engineer-in- Charge.
MCB SP, 6 to 32 Amps, 240 Volts to be housed in DBs of Proper and suitable size cable lugs to be fixed with MCBs,complete all as specified and directed by Engineer-in- Charge.
MCBs SPN 40 Amps to 63 Amps, 240 Volts to be housed in DBs Proper and suitable size cable lugs to be fixed with MCBs ,complete all as specified and directed by Engineer-in- Charge.
PVC Junction box weather proof IP-65 conform to EN 60439-3, recessed with wall surfaces by chase cutting and making good surface of wall, complete all as specified and as directed by Engineer-in- Charge.
Rigid PVC conduit pipe of size 20 mm dia, fixing the same on the wall including fixing accessories ie. PVC junction boxes, bends, sanddles, elbows anchor nuts, GI clamps reducers etc ,complete all as specified and as directed by Engineer-in- Charge.
LED type post top lanterns 25 watt, energy saving fitting, aluminium spun landscape luminaires with high power LED as light sopurce including making connections ,complete all as specified and as directed by Engineer-in- Charge.
Supply, fixing, connecting and testing LED security light fittings 45 watt 5700K with 5700K with IP-66 protection comprises of a pressure die cast aluminium housing, heat resistance toughened glass , LED lenses, surge protector, electronic driver etc and all accessories prewired including connecting up with PVC insulaterd copper condductor cable 1.5 sqmm 3 core as required for connections and 32 mm bore light frade GI tube mounting bracket of 1.5 metre in length, bend to shape at 140 degree in L shape and fixed to wall by means of 02 Nos of 40x5 mm flat iron clamps, nuts, bolts and washers etc , complete all as specified and as directed by Engineer-in- Charge.
Supply and fixing Solar Street light System 12 watt LED light in built SCC, 60 watt SPV panel, 40 AH battery, 5 mtr Tubular pole with 3 day battery backup, automatic ON-OFF system, change controllert system and other connected part including electric connection with PCC foundation of pole ,complete all as specified and as directed by Engineer-in- Charge.
Supply and install and testing of Deep freezer of capacity 300/320 Ltrs double door suitable for working on 230 Volt SP 50 Hz ,complete all as specified and directed by Engineer-in-Charge
Supply only fine sand at site including royalty and carriage for preparing compost at site complete all as specified and as directed by Engineer-in- Charge. (Sand shall be brought at site and stacked for measurement before incorporation in the work)
Supply only sweet/good earth at site including royalty and carriage for preparing compost for pits required for planting trees and shrub etc complete all as specified and as directed by Engineer-in- Charge. (Sweet/good earth shall be brought at site and stacked for measurement before incorporation in the work, 20% of the computed volume shall be reducted for loose stacking)
Supply only manure at site including royalty and carriage for preparing compost at site complete all as specified and as directed by Engineer-in- Charge. (Manure shall be brought at site and stacked for measurement before incorporation in the work, 8% of the computed volume shall be reducted for loose stacking)
Supply only plantation of chinese carpet grass by ploughing of whole site in soft ordinary soil upto depth of 20 cm and removing all the unwanted material such as stones, weeds, tree roots etc which are not suitable for healthy growth of grass, dressing and reeling of soil to a required gradient ans slope on completion of work after loosening of soil, mixing manure and soil evenly as directed including fertilizer, ATT chemical etc complete all as specified and as directed by Engineer-in- Charge.
Planting of Amla tree of height 2' - 4' along with necessary earth work and manure complete all as specified and as directed by Engineer-in- Charge.
Planting of Gulmohar (Jacarande mimosaefotie) of height 2' - 4' along \with necessary earth work and manure complete all as specified and as directed by Engineer-in- Charge.
Planting of Amaltas tree of height 2' - 4' along with necessary earth work and manure complete all as specified and as directed by Engineer-in- Charge.
Planting of Lichi tree of height 2' - 4' along with necessary earth work and manure complete all as specified and as directed by Engineer-in- Charge.
Planting of Desi Ashok tree of height 2' along with necessary earth work and manure complete all as specified and as directed by Engineer-in- Charge.
Planting of Mango (mangifera indica) of height 2' along with necessary earth work and manure complete all as specified and as directed by Engineer-in- Charge.
Planting of Neem (Azadirachats indica) of height 1' - 6' along with necessary earth work and manure complete all as specified and as directed by Engineer-in- Charge.
Planting of Gauva (Psidium guajava) of height 2' along with necessary earth work and manure complete all as specified and as directed by Engineer-in- Charge.
Planting of Lemon hybrid (C lemon) of height 1' - 6' along with necessary earth work and manure complete all as specified and as directed by Engineer-in- Charge.
Planting of Golden Duranta of height 1' along with necessary earth work and manure complete all as specified and as directed by Engineer-in- Charge.
Planting of Custard Apples (Sharifa, Seeta phal) along with necessary earth work and manure complete all as specified and as directed by Engineer-in- Charge.
Planting of Juniprus prostrata of height 1' along with necessary earth work and manure complete all as specified and as directed by Engineer-in- Charge.
Supply only of best quality healthy of Bouganvillaes all colors plant (12 to 18 inches hybrid vareity) suitable for planting in pot complete all as specified and as directed by Engineer-in- Charge.
Supply only of best quality healthy Crotons (various types/varieties) plant complete all as specified and as directed by Engineer-in- Charge.
Supply only of best quality healthy Areca palm complete all as specified and as directed by Engineer-in- Charge.
Supply only of best quality healthy Roses (various types/varieties) plant complete all as specified and as directed by Engineer-in- Charge.
M&L Continuous brick edging with fly ash bricks old size bricks with width equal to the depth of the brick laid dry on end at required angle including three coats of white washing complete all as specified and as directed by Engineer-in- Charge.
Supply only flower/plant pot (Gamla) made of cement concrete of top dia 40 cm and bottom dia 25 cm and height 45 cm and wall thickness 5 cm complete all as specified and as directed by Engineer-in- Charge.
Supply only flower/plant pot (Gamla) made of cement concrete of top dia 30 cm and bottom dia 20 cm and height 30 cm and wall thickness 5 cm complete all as specified and as directed by Engineer-in- Charge.
Steel tubing 20 mm nominal bore , 'medium grade', galvanised, with all fittings ; laid in trenches complete all as specified and as directed by Engineer-in- Charge.
NEW BHARAT ENGINEERING AND CONSTRUCTION CO
PUMA POWER
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .