| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.9 LAccepted-AOC 3RD FLOOR VVIP RESIDENCY MAHINDER VIHAR CHAKRATA RD NEAR RAMADA HOTEL DEHRADUN UTTARAKHAND 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC Overall Reasonable | |
| 2 | L2₹14.8 L+₹1.5 L (11.7%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹15.0 L+₹1.8 L (13.3%)Rejected-Finance OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹15.3 L+₹2.1 L (15.9%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹18.3 L+₹5.0 L (38.0%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
8 Oct 2020, 6:00 pmClosed
GE CENTRAL KIKREE
GE CENTRAL ANGE HILLS ROAD KIKREE PUNE 411003
REPAIR MAINTANCE OF AIR CONDITIONERS AND COOLING APPLIANCES UNDER AGE EM II IN GE (C) KIRKEE
2020_MES_376815_1
8393/E8 OF 2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KIRKEE
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE CENTRAL KIKREE
₹40,000
Yes
28 Dec 2020
12 Sept 2020
10 Oct 2020
12 Sept 2020
8 Oct 2020
26 Sept 2020
12 Sept 2020 - 25 Sept 2020
Amount
Disconnecting split/window type AC (Out door+Indoor unit) of any capacity and type by electrically/mechanically and lowering to the ground fixed in any position for servecing/repairing/overhauling/cleaning, and cleaning filters, checking of electrical wiring, cleaning of dust by blower and washing with washing soda complete etc including replacement of unserviceable, burnt out spare parts to make it fully functional, after repair and re-installation and testing on full load completion to the entire satisfaction of Engr-in-Charge including transporting to workshop and back to site. Note :- Item replaced will be measured and paid separately.
Disconnecting Water cooler of any capacity and type by electrically/mechanically for repairing/overhauling/cleaning, checking of electrical wiring, cleaning of dust by blower including replacement of unserviceable, burnt out spare parts such as relays thermostates etc to make it fully functional, after repair and re-installation and testing on completion to the entire satisfaction of Engr-in-Charge including transporting to workshop and back to site. Note :- Item replaced will be measured and paid separately.
Supply and fix micro processor printed circuit board comlete suitable for split type AC of any capacity as suitable for existing make/model and capacity 1.5/2 Ton and all as directed.
Disconnection and taking out old defective Hermetically sealed compressor unit as required of AC/water coller/refrigerator and M&L for fixing new compressor (new sealed unit only) sealed unit by means of nut bolt & washer with antivibrating bush/ pad and brazing work, pressure testing for leakage, vaccumising and gas charging etc of capacity 1.5 TR for window/Split AC of the existing makes:-Voltas/Hitachi/Emersion/ Carrier /Shriram(Techmesh) .
All as per item no 4 above but of capacity 2 TR for window/split AC.
All as per item no 4 above but suitable for Water cooler of capacity 40ltrs.
All as per item no 4 above but suitable for Water cooler of capacity 60ltrs.
All as per item no 4 above but suitable for Water cooler of capacity 80ltrs.
All as per item no 4 above but suitable for Water cooler of capacity 100/120ltrs.
Supply and fix hermetically sealed unit new Compressor by dismantling burnt out u/s Compressor suitable for refrigirators of following capacities including provn of bushes, sleeves, washers nut and bolt for Compressor foundation legs including relay terminal cover and clips on and including cutting, brazing, leak detection, charging refrigerent and commissioning testing for 165 - 200 ltr capacity.
Disconnecting Electric conection, removing/transporting the unsv water cooler of capacity 40 ltrs to 120 Ltrs to auth workshop for painting work which includes removing the existing deteriorated/rusted body of water cooler of any size and capacity for paint by scrapping and filling of cavaties with filler spray, denting/ welding, patch work with existing size of MS sheet and painting the body with synthetic enamel paint two coats over a coat of redoxide and marking the SM/MES No (of reqd size and shape) with black paint complete all as specified for as directed by Engr-in-Charge.
M & L for cleaning the gas system of split AC/Window type AC with carbon tetra chloride chemical & flushing with Nitrogen and charging the gas ( Refrigerant R-22) including brazing/testing and commissioning complete of size 1/1.5 Ton capacity.
---- ditto ---- but of capacity 2 ton.
M & L for cleaning of gas system of the water cooler/ refrigerator with carbon tetra chloride chemical & flushing with Nitrogen and charging the gas ( R-134) including brazing/testing and commissioning complete of capacity 40 ltrs to 80 ltrs.
--- ditto--- but of capacity 100/120 ltrs.
S & F in replacement thermostate suitable for water cooler/ refrigerator/ AC of any type and any model complete.
M&L for replacement of overload protection relay for window AC, water cooler and refrigaretor of make and model as per existing.
M&L for replacement of starting relay for window A/C water cooler & refrigaretor of make and model as per existing.
S & F in replacement of running capacitor 10 MFD.
S & F in replacement of running capacitor 25 MFD.
S & F in replacement of running capacitor 36 MFD.
S & F in replacement of running capacitor 45 MFD.
S & F in replacement of starting capacitor 40/60 MFD
S & F in replacement of starting capacitor 80/100 MFD.
S & F in replacement of starting capacitor 100/120 MFD.
S & F in replacement for cromium plated push cock for water cooler of size 15mm dia .
S & F in replacement of PVC float valve for water cooler of size 15mm dia.
S & F in replacement of drier filtter for AC/water cooler/refrigaretor.
S & F in replacement of capillary tubing of any size not less than 0.5 mtr for AC/Water cooler/refrigerator.
S & F for PVC drain pipe suitable for water cooler out let of any capacity.
M & L for dismantling of existing unservicebale voltage stablizer for repairs including replacement of relays electronic voltage sensor circut and meter, micro switch, indication light RC filters and other connected items for making functional and rewinding of unserviceable transformer with super enameled copper wire of appropriate size, varnishing assembling and testing completeof capacity 2 KVA to 5 KVA upto satisfactory function of any capacity all as directed by Engr- in-Charge.
Taking out the unserviceable blower motor from Water cooler/AC of any capacity and transporting to workshop for repair, dismantling & removing the burnt winding & rewinding it with same gauge, super enameld copper winding wire including replacment of minor hardware and fixing it at locations & testing complete all as directed by Engr-in-Charge for capacity 1/8 HP.
--- ditto--- but of capacity 1/6 HP.
--- ditto--- but of capacity 1/4 HP.
--- ditto--- but of capacity 1/3 HP.
M&L for replacement of unserviceble & damaged burnt blower motor/fan motor Window/Split AC of capacity 1/6 HP.
--- ditto ---- but of size 1/4 HP.
M&L for replacement of unserviceble & damaged burnt blower motor/fan motor of Water cooler of capacity 1/8 HP.
--- ditto --- but of capacity 1/3 HP.
--- ditto --- but of capacity 1/2 HP.
S & F in replacement of Flexible multi stranded PVC insulated and PVC sheathed copper cable of size 2.5 sqmm 3 core cable.
S & F in replacement 3 pin plug top of capacity 15 amp.
PVC connections 15 mm size with PTMT nuts of length 450 mm.
--- ditto --- but of length 600 mm .
Replacement of rubber gasket for lid top of any size for water coolers.
Supply and fixing sub main wiring of two single core FRLS-H PVC insulated unsheathed stranded copper conductor cables of size 4 Sqmm, 1100 volts grade, drawn through and including 20 mm dia PVC surface conduit of 1.2 mm wall thickness including all fixing accessories, and 4 sqmm PVC insulated stranded copper conductor cable as earth wire connected to earth dolly complete all as specified and directed. (Phase-Red, Neutral – black in colour of cable) Note:- Both running cables including earth wire including one run pvc conduit pipe shall be measured & paid for as single length.
Supply and fixing sub main wiring of two single core FRLS-H PVC insulated unsheathed stranded copper conductor cables of size 6 Sqmm, 1100 volts grade, drawn through and including 20 mm dia PVC surface conduit of 1.2 mm wall thickness including all fixing accessories, and 6 sqmm PVC insulated stranded copperconductor cable as earth wire connected to earth dolly complete all as specified and directed. (Phase-Red, Neutral – black in colour of cable) Note:- Both running cables including earth wire including one run pvc conduit pipe shall be measured & paid for as single length.
Supply and fixing sheet metal enclosure with socket plug top, single pole and neutral enclosure with two pin and earth plug and socket complete with one no MCB SPN , 20 Amps , 230 volts complete all as specified .
S&Fof Heavy duty air conditioner outdoor unit stand/ brackets with complete accessorise for windos/split AC of capacity of 1.5/2 Ton complete with grouting nut bolts all as specified and as directed by Engr-in-charge .
Supply & fixing in repairs MCB's 240V confirming to IS of rating 6A to 32A SP, ' C' Series, 10 KA breaking capacity complete all as directed by Engr-in-Charge.
S & F in replacment of Copper Condenser unit assembly for Outdoor Unit with all accessories suitable for split AC of capacity 1.5/2 ton complete .
S & F in replacment of Copper Condenser unit assembly for window AC with all accessories complete of capacity 1.5/2 ton.
Taking out the motor from indoor unit of split AC any capacity with rubber roller and replacing with new motor of suitable for the existing make/model and capacity all as specified and directed.
S & F in replacment of suction valve for split AC of any capacity.
S & F for PVC drain pipe suitable for split AC out let of 1.5T/2.T capacity.
S & F in replacment of discharge valve for split AC of any capacity.
Dismantling of old split type air conditioner indoor unit and Supply , installation and testing Indoor unit of split type air conditioner complete with cordless remote control and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 1.5 Ton with wall mounted fixing plate suitable size incl breezing work for fixing existing site complete all as directed. Make - Voltas / LG / Blue star.
Disconnecting and taking down unserviceable/damage outdoor unit cover of split air conditioner of capacity 1.5 Ton and dismantaling of compressor ,condenser unit,wiring,fan motor from outdoor cover and supply and fixing new outdoor cover with replacement of unserviceable spare parts such as capacitor ,control wiring and refixing compressor ,condenser unit,wiring,fan motor to make it fully functional, after repair and re-installation as per existing and testing on completion to the entire satisfaction of Engr-in-Charge. Note :- Items as declared unservicable by Engineer in charge shall be measured and paid separately.
M/s. ANAND ENTERPRISES
M/S. Niksun Electro-Infra Private Limited
BRILLIANT AIRCONDITIONING AND REFRIGERATION WORKS
M/S EAGLE ENTERPRISES
Choudhary Traders and Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .