Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.8 LAccepted-AOC SOUTH VIJAYANARAYANAM 1 33 CENTRAL STREET NANGUNERI TALUK TIRUNELVELI DIST TAMIL NADU 627 118 | SOUTH VIJAYANARAYANAM | TIRUNELVELI | TAMIL NADU | 627118 | L1 | Accepted-AOC L1 | |
| 2 | L2₹44.4 L+₹1.3 L (3.05%)Rejected-Finance | L2 | Rejected-Finance L1 being accepted | |
| 3 | L3₹44.7 L+₹1.6 L (3.65%)Rejected-Finance ANGALAMMAN KOVIL STREET ULIYANALLORE POST PANAPAKKAM VIA ARAKKONAM TK VELLORE DIST TN 631 052 | ARAKKONAM | VELLORE | TAMIL NADU | 631052 | L3 | Rejected-Finance L1 being accepted | |
| 4 | L4₹44.8 L+₹1.7 L (3.92%)Rejected-Finance CHENNAI | L4 | Rejected-Finance L1 being accepted | |
| 5 | Rejected-Technical | - | Rejected-Technical The firm has not been enlisted for eligible category i.e. b(i). |
Tender Value
Refer Docs
EMD Value
₹85,000
Closing Date
6 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Tirunelveli
GE TIRUNELVELI INS KATTABOMMAN NAVAL BASE POST VIJAYANARAYANAM TIRUNELVELI
GE/TVL/8174
2021_MES_466725_1
GE/TVL/8174
Open Tender
Miscellaneous Works
Item Rate
180 days
Vijayanarayanam
As per NIT/ Tender documents
8 documents required · 8 mandatory
₹500
GE Tirunelveli
₹85,000
Yes
30 Sept 2021
10 Aug 2021
8 Sept 2021
10 Aug 2021
6 Sept 2021
24 Aug 2021
10 Aug 2021 - 18 Aug 2021
60 days
Amount
SCHEDULE 'A' PART-I [ B/R WORKS]
M&L for complete removal of existing treatment on surfaces of wall by washing rubbing down and scraping down surfaces and applying two coat of oil bound distemper over a coat of primer complete all as specified and directed
M&L for complete removal of existing treatment on surfaces of wall, chajjas etc by washing rubbing down and scraping down surfaces and applying two coat of superior quality anti algae weather proof acrylic paint exterior grade over a coat of primer with approved camouflage pattern on external surface complete all as specified and directed
M&L for preparation of old decorated plastered surface on ceiling and applying one coat of oil bound distemper all as specified and directed by Engineer in Charge.
M&L for preparation of old painted wooden surfaces over 10cm on width or girth of any description and applying one coat of synthetic enamel paint all as specified and directed by Engineer in Charge.
M&L for preparation of old painted steel surfaces over 10cm on width or girth of any description and applying one coat of synthetic enamel paint all as specified and directed by Engineer in Charge.
M&L for preparation of old painted steel surfaces over 10cm on width or girth of any description and applying one coat of satin enamel paint all as specified and directed by Engineer in Charge.
M&L for preparation of old painted steel surfaces n. exc 10cm on width or girth of any description and applying one coat of satin enamel paint all as specified and directed by Engineer in Charge.
M&L for preparation of old decorated plastered surface of walls and applying one coat of weather proof emulsion paint of approved colour on external walls complete all as specified and directed by Engineer in Charge.
M&L for preparation of old surface of roof and applying one coat of weather proof emulsion paint of approved colour on roof complete all as specified and directed by Engineer in Charge.
Material and labour for preparation of old camouflange pattern painted on steel surfaces over 10cm on width or girth of external surface and applying one coat of exterior enamel paint of approved camouflange pattern on external MS sheet wall complete as per specification and directed by Engineer in Charge. Note : The quoted rate deemed to includes necessary scaffolding & precautionary measures for painting upto 12 metres height.
M&L for preparation of old camouflange pattern painted APP water proofing membrane on roof surface over 10cm on width or girth and applying a coat of exterior enamel paint in approved camouflange pattern on APP water proofing membrane roof complete as per specification and as specified and directed by Engineer in Charge.
Material and labour for preparation of old camouflange pattern painted steel surfaces n. exc 10cm on width or girth and applying one coat of exterior enamel paint of approved camouflange pattern on steel surface complete as per specification and as specified and directed by Engineer in Charge.
Material and labour for writing letters or figures (Block , roman , Italic or Indian) n.exe 30 CM high with using synthetic enamel paint complete all as specified and as directed.
Material and labour for Roof treatment in steel surface with 3mm thick APP modified waterproofing membrane weighing not less than 3kg/sqm reinforced with non woven polyster matt weighing not less than 160 gm/sqm laid over steel roof surfaces and vertical surfaces upto grooves and width of overlap 75 mm at the sides and 100 mm at the ends fixed with hot blown tourching including applying of one coat of blown grade hot bitumen 85/25 over the membrane @ 1.20 kg / sqm and includingtaking down old membrane and cleaning of steel surfaces complete all specified and as directed. Note:- The work shall be done through authorizes dealers/applicator only.
M&L for preparation of damp surfaces of walls by scrapping loose scales and putty/paint using patra(putty blade) upto the plaster of wall ; then cleaning the surfaces of walls with wire brushes and compressed air blower ; scrubbing down with water & well dried ; the applying a coat with mixture Dr Fixit DampGuard classic in 1:1:1 ratio (i.e one unit of portable water, one unit of base & one unit of hardner) and the coat is allowed to dry for 24 hour ; after which preparing the surfaces repaired and matching the same with the adjoining surfaces/texture with paint complete all as specified and as directed by Engineer-in-Charge. Note : The quoted rate is inclusive of necessary scaffolding and safety measures etc upto a height of 10 meters.
M&L for providing, erecting and dismantelling of safe pipe scaffolding and/or H frame including working platform for external and internal area of building to facilitate all works with proper arrangements etc. complete. Note:-Measurement for scaffolding shall be measured by Length x Height
M & L for treatment of cracks between Brick wall and RCC column and beam member joints by widen the cracks to a width and depth of 20x40mm using a portable concrete cutter, Clean the cracks using hard paint brush in order to remove all dust and loose particles within the joints and both side edges finishing with neatly. If any hollow portion (or) uneven surface, the surface filling with FOSROC RENDEROC SP 40. Use a closed cell polyethylene "U" foam board and rod as a backup material and it is required as per side conditions after the above the process application of FOSROC THIOFLEX 600 complete all as specified and as directed by Engineer-in-Charge. Note:1.The quotated rate including cost of materials, tools and labour charges as per instruction of authorised dealer. 2.Scaffolding materials shall measured and paid seperately.
M & L for treatment of masonry/plaster cracks upto 10mm width by widen the cracks to a width and depth of 5x5 mm using a portable concrete cutter and prepare the surface thoroughly by cleaning, washing and removing dust, dirst, loose particles and all surface cracks up to a 5mm width should be filled up with FOSROC RENDERCO CS as per manufacturer instruction complete all as specified and as directed by Engineer-in-Charge. Note:1.The quotated rate including cost of materials, tools and labour charges as per instruction of authorised dealer. 2.Scaffolding materials shall measured and paid seperately.
M & L for Water proofing treatment between pipe and RCC slab by removing the existing cement plastering, concrete and APP bitumen’s membrane and widen the joints to a width and depth of 25 x 50 mm using a portable Concrete cutter and Clean the surface using hard paint brush in order to remove all dust and Loose particles within the joints ,30 mm depth filling with FOSROC RENDEROC RG and 20 mm depth filling with NITOSEAL PU 40 (OR) TECHSEAL PU-1 (Polyurethane based sealant). After the above process, Prepare the surface thoroughly by cleaning, washing and removing dust, dirt, oil, grease, loose particles.Checked all the surfaces if any cracks must be cut and repaired with a polymer modified screed. If any hollow portion filling with polymer modified cement mortar and providing Two coats of FOSROC BRUSHBOND (or) FOSROC NOTOPROOF 600 as per manufacturer instruction complete all as specified and as directed by Engineer-in-Charge. Note:1.The quotated rate including cost of materials, tools and labour charges as per instruction of authorised dealer.
M & L for lime injection to the setteled area of soil by drill cores on the paver area at a regular spacing of 1.5m c/c and provide auger of minimum 100mm diameter and grout the hole with lime, before the grout the lime should be mixed with modified lignosulphate as per manufacturer instruction complete all as specified and as directed by Engineer-in-Charge. Note No.1 :- Rates are including core cutting and providing augers for injection. Note No.2 for Item No.18 to 21:- (a) The entire process explained above shall be carried out through the Fosroc chemicals licensed applicator only. (b) The chemicals used for the work shall be manufactured by Fosroc chemicals or equivalent as approved by GE. (c) The quoted rates is inclusive of cost of materials, tools , labour charges, removing debris, cleaning the surface and match the surface with existing finishes as per instruction of authorised dealer.
Material and labour for post construction anti-termite treatment for providing & injecting along the external wall below concrete or masonry apon using chemical emulsion @ 2.25 liter per linear meter including drilling and plugging holes etc in apron/plinth protection complete all as specified and as directed.
Material and labour for post construction anti-termite treatment of peripery of internal wall (where the flooring is tile and similar) using chemical emulsion @ one liter per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2(1 part cement and 2 part coarse sand) mixed with pigment to match the existing floors complete all as specified and as directed.
Material and labour for poat construction anti-termite treatment for providing & injecting at point of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.50 ltr/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and as directed.
Demolition of Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
Material and labour for providing plain cement concrete 1:2:4 type B1, using 20mm graded stone aggregate as in flooring 40mm thick finished even and fair including form work all as specified and as directed.
Material and Labour for Vitrified ceramic coloured tiles double charged/dark shade 10mm thick (square/rectangular) area of each tile exceeding 0.42 Sqm and not exceeding 1.00 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed of 15mm thick in CM 1:6 complete all as specified and as directed.
Material and Labour for vitrified ceramic tiles 10mm thick double charged /dark shade (Square / rectangular) polished, area of each tiles exceeding 0.42 Sqm and not exceeding 1.00 Sqm, as in vertical surface, over and including provision of cement bedding 10 mm thick in CM 1 : 4 set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and as directed
SCHEDULE 'A' PART-II [ E/M WORKS]
Excavation in trenches n.exc 1.5 M wide and n. exc 1.5 M depth and getting out in hard/dense soil for removing / taking out burnt cables complete all specified and as directed.
Returning, filling in trenches including spreading, leveling, watering and in layers n.exc 25cms thick without damaging pipes/special fittings as in any type of soil complete all as specified and directed.
Removing excavated materials to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
Supply and spread river sand in trenches for cable cushioning complete all as specified and directed. Note:- (Punned thickness only will be measured)
Supply and lay burnt bricks of old size sub-class B for cable protection all as directed & as specified.
Material and labour for fixing the new moulded case circuit breakers (MCCB) in the existing feeder pillar box with new bolts and nuts including connecting the incoming and out going cables by using suitable cable glands and jumpers/cable with the bus bar including taking down burnt out MCCB, of following capacity in the existing feeder Pillar box complete as specified and directed.
a) MCCB 4 Pole 800 Amps 50 KA. Make:- L&T Cat No-CM96111OOOOX1 or equivalent in LEGRAND/ ABB/ SIEMENS/SCHNEDER/C&S/HAVELLS
(b) MCCB 4 Pole 630 Amps 50 KA. Make:- L&T Cat No-CM93008OOOOX1 or equivalent in LEGRAND/ ABB/SIEMENS/SCHNEDER/C&S/HAVELLS
(c) MCCB 4 Pole 250 Amps 36 KA. Make:- L&T Cat No-CM93003OOOOX1 or equivalent in LEGRAND/ABB/SIEMENS/SCHNEDER/C&S/HAVELLS
(d) MCCB 4 Pole 200 Amps 36 KA. Make:- L&T Cat No-CM93003OOOOX1 or equivalent in LEGRAND/ ABB/SIEMENS/SCHNEDER/C&S/HAVELLS
(e) MCCB 4 Pole 160 Amps 25 KA. Make:- L&T Cat No-CM90642OOMO or equivalent in LEGRAND/ ABB/SIEMENS/SCHNEDER/C&S/HAVELLS
(f) MCCB 4 Pole 125 Amps 25 KA. Make:- L&T Cat No-CM90642OOMO or equivalent in LEGRAND/ ABB/SIEMENS/SCHNEDER/C&S/HAVELLS
(g) MCCB 4 Pole 100 Amps 25 KA. Make:- L&T Cat No-CM91712OOKOOG or equivalent in LEGRAND/ ABB/SIEMENS/SCHNEDER/C&S/HAVELLS
Material and labour for fixing the new Miniture circuit breakers (MCB) in the existing feeder pillar box with new bolts and nuts including connecting the incoming and out going cables by using suitable cable glands and jumpers/cable with the bus bar including taking down burnt out MCCB, of following capacity in the existing feeder Pillar box complete as specified and directed.
(a) MCB 4P, 32 Amp, 10 KA, 'C' Series. Make:- L&T Cat No-BB40320C or equivalent in LEGRAND/ABB/ SIEMENS /SCHNEDER/C&S/HAVELLS
(b) MCB 4P, 63 Amp, 10 KA, 'C' Series. Make:- L&T Cat No-BB40630C or equivalent in LEGRAND/ABB/SIEMENS/SCHNEDER/C&S/HAVELLS
(c) MCB TP, 32 Amp, 10 KA, 'C' Series. Make:- L&T Cat No-BB30320C or equivalent in LEGRAND/ABB/ SIEMENS/SCHNEDER/C&S/HAVELLS
(d) MCB 4P, 80 Amp, 15 KA, 'C' Series. Make:- L&T Cat No-AU15S40803Cor equivalent in LEGRAND/ABB/ SIEMENS/SCHNEDER/C&S/HAVELLS
(e) MCB 4P, 40 Amp, 10 KA, 'C' Series. Make:- L&T Cat No-BB40400C or equivalent in LEGRAND/ABB/ SIEMENS/SCHNEDER/C&S/HAVELLS
(f) MCB DP, 40 Amp, 10 KA, 'C' Series. Make:- L&T Cat No-BB20400C or equivalent in LEGRAND/ABB/ SIEMENS/SCHNEDER/C&S/HAVELLS
(g) MCB DP, 32 Amp, 10 KA, 'C' Series. Make:- L&T Cat No-BB20320C or equivalent in LEGRAND/ABB/ SIEMENS/SCHNEDER/C&S/HAVELLS
(h) MCB 4P, 16 Amp, 10 KA, 'C' Series. Make:- L&T Cat No-BB40160C or equivalent in LEGRAND/ABB/ SIEMENS/SCHNEDER/C&S/HAVELLS
(j) MCB SP, 6-32 Amp, 10 KA, 'C' Series. Make:- L&T or equivalent in LEGRAND/ABB/SIEMENS/ SCHNEDER/ C&S/HAVELLS
M & L for opening the cover of LT panel checking for tightness of all connection/joints, cleaning dust and drit from busbar, checking ACB 4000/3200/1600/800 A, 440V, 4P and servicing/ of fixed and moving contacts, repair and replacement of fixed copper terminal/contacts (male and female ),insulation tubes including other connected items to functional of panel board , lamp indicators ,meters, tripping coil , caliberation of over load protection relay , time delay relay /earth fault relay etc . Claening the fixed and moving contact inside the ACBs properly , checking of EDO/MDO mechanism, servicing and graesing all movable machanisum , replacement of defective fuses , wiring and reassembling and testing and serviceability check complete all as per the direction of Engineer in Charge and manufacturer instructions. Note : Servicing will be done by authorised dealer only
M & L for checking of Shunt release coil and repair/ replacement of shunt release coil for ACB as per sample complete all as specified and directed by Engr-in-Charge.
M & L for checking of under voltage release coil and repair/ replacement of under voltage release coil for ACB as per sample complete all as specified and directed by Engr-in-Charge.
M & L for checking and servicing of 30 KVA UPS system, checking battery terminal for tight or replacement, connection cable including other connected items to functional of panel board , lamp indicators ,meters, lubricating battery terminal, replacement of defective fuses , wiring, IGBT card, Control card, rectifier unit with air exhaust system, capacitor and reassembling and testing and serviceability check complete all as per the direction of Engineer in Charge and manufacturer instructions. Note : Servicing will be done by authorised dealer only
M & L for taking down old unserviceable battery and replacement with new sealed maintenance free lead acid battery12 V, 42 AH including connected wire and clamps for 30 KVA UPS system complete all as specified and directed by Engr-in-Charge. Make: Exide Model EP-42-12 or equivalent Amaron/Luminous
Supply, laying and testing LT under ground cable 1100 volts grade PVC /XLPE insulated and sheathed armoured multistranded heavy duty electric power cable with aluminium conductor 4 core 10 Sqmm, laid in trenches/ duct / walls including cable gland on both termination where necessary including laying, connecting to various switches in panel board,etc, testing and commissioning including taking down old cable etc complete all as specified and directed. NOTE: Earth work excavation shall be measured and paid separately.
Description all as per item No 59 but 4 core 25 Sqmm size complete all specified and as directed.
Description all as per item No 59 but 3.5 core 35 Sqmm size complete all specified and as directed.
M & L for repair to LT panel door with repair/replacement of hinges, welding, replacement of defective packing/ rubber pad of panel etc. and making good the distrubed surfaces of panel with powder coating finish complete all specified and as directed.
S & F LT bus bar box of size 600x500x300mm, outdoor type made out of MS sheet 2mm thick CPRI Approved,panel board supported by angles of size 50x50x6mm, 800mm long with nut, bolts and washer of suitable size fixed on ground including earthwork excavation, PCC 1:3:6 mix B1 type with 20mm agreggate for foundation including provinding aluminium busbar 400mm long and 40x5mm thick, 4 Nos with supporting insullator and colour code PVC sleeves including necessary bottom plate with hole for entry of cablesomplete all specified and as directedby Engr-in-Charge.
SRI LAKSHMI GANESH ENGINEERING WORKS
JR ENTERPRISES
VVM CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .