Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.5 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹49.5 L+₹95,775 (1.97%)Rejected-Finance 121004 | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹49.6 L+₹1.1 L (2.19%)Rejected-Finance D 235 ADG P CHENNAI | CHENNAI | TAMIL NADU | 600001 | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹49.7 L+₹1.1 L (2.29%)Rejected-Finance NO 2 16 KANGAYAMPALAYAM SULFUR PO COIMBATORE 641 401 | COIMBATORE | COIMBATORE | TAMIL NADU | 641401 | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹49.7 L+₹1.1 L (2.31%)Rejected-Finance 31 CHAIRMAN KARUPPANA THEVAR STEET SULUR COIMBATORE 641 402 | COIMBATORE | TAMIL NADU | 641402 | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
15 Sept 2020, 6:00 pmClosed
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
REPAIR MAINT OF WATER SUPPLY PUMPING NETWORK PUMP MOTORS AND OTHER MISC WKS AT AFS SULUR
2020_MES_372170_1
8348/E8
Open Tender
Miscellaneous Works
Item Rate
240 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE AF SULUR
₹98,000
Yes
7 Oct 2020
26 Aug 2020
16 Sept 2020
26 Aug 2020
15 Sept 2020
9 Sept 2020
26 Aug 2020 - 8 Sept 2020
Amount
SCHEDULE A BOQ
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5m deep in hard/dense soil and getting out for taking down/laying of pipes
Returning, refilling including spreading levelling watering and well ramming in layers not exceeding 25cms thick in hard/dense soil
Removing excavated materials not exceeding 50m distance and depositing where directed at level not exceeding 1.5 m above the starting point
Rectification of existing defective flanged joints with rubber or fibre gasket complete with necessary nuts, bolts and washers for 150 mm dia GI/DI/MS pipes complete all as directed. Note:- a) quoted rates are inclusive of cutting of GI/DI/MS Pipes, jointing materials and preparation of new flanged sockets and refixing the same at existing place. (b) Necessary excavation shall be measured and paid separately under respective items of BOQ
Making arrangement to flush out the existing pipe line of any type 110 to 150mm bore and upto 100m length, applying 4.5 N/sqmm pressure kg/sq cm pressure to remove scalings/ sludges/ other blocking materials to make smooth flow of water including testing all as specified and directed.
Making arrangement to flush out the existing pipe line of any type 160 to 200 mm bore and upto 100m length, applying 4.5 N/sqmm pressure kg/sq cm pressure to remove scalings/ sludges/ other blocking materials to make smooth flow of water including testing all as specified and directed.
Note for item 6 & 7 :- (i) The Contractor is deemed to arrange necessary tools and equipments, removing or alteration of fittings from existing pipe lines, arragement of plugging devices, etc to build up specified pressure required to wash out the pipes. This will be inclusive in quoted rate.
(ii) Excavation and earth work required will be measured and paid seperately.
(iii) The flushing out will be carried out with fresh filled water of well only duly chlorinated with specified sodium hypochlorite solution to disinfect the pipe lines from all pathogens and Coliform organisms.This will be inclusive in quoted rate.
Cleaning of valve pit chamber for sluice/gate valve of 50/80/100/150/200/ size by removing mud/ grass/ sludge/ other waste materials from the chamber and from surroundings upto 1mtr distance, carryout petty cement repairs with cement mortar 1:4, apply one coat of white wash on cemented surfaces and one coate of synthetic paint on steel surfaces complete to make an operator friendly valve chamber complete as specified and directed. Note :- Periodicity and locations of valve chambers will be given as per requirement by the Engineer-in-Charge.
Taking down defective centrifugal pump set 60 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. (Supply of spare parts shall be measured and paid for separately under respective items here-in-after). Make of Pump : Kirloskar Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 1000 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other than the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only Ball bearing suitable for 60 HP motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC
Supply only coupling bolt with nuts suitable for 60 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling Rubber Bush suitable for 60 HP motor pump as per manufacturer's design complete all as specified and as directed..
Supply only split casing gaskets suitable for 60 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only shaft sleeves suitable for 60 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only Air cock grease nipple suitable for 60 HP motor pump as per manufacturer's design complete all as specified and as directed.
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 60HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable for 60HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only bronze impeller suitable for 60HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply and fix CI foot valve 150mm dia to suction line of exisiting pumping set with bolts, nuts, rubber packings, etc including taking out old unserviceable one by dismantling suction pipe from pump set all as specified and directed.
M&L PCC 1:1½:3 type A0 (using 12.5 mm graded stone aggregate) as in floor finishing finished even and smooth without using extra cement complete all as specified and directed
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
M& L for Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc with Fe 410 -W (Gde- E- 250) including dismantling of existing steel complete all as specified and directed.
Cleaning/ overhauling of squirrel cage induction motor by dismantling stator and rotor assembly, carryout necessary tesing of windings to findout any core loss in windings, test of insulation resistance, etc. Applying of proper insulation material for strengthening of insulation, cleaning the casing and slots with wire brush, washing out dust and carbon particles with proper chemical solution, replacement unserviceable bearing, bush, carryout re-alignment of crank shaft re-assembling stator and rotor assemblies, testing complete all as specified and directed for capacity upto 60 HP. Note:- (i) Rewinding of stator and rotor if required will be measured and paid seperately. (ii) Cost of Transportation to and from the local workshop is deemed to be incl in the quoted rate.
Rewinding of stator core with proper gauge and amount of highly insulated copper wire as existing, testing complete.
Rewinding of rotor core with proper gauge and amount of highly insulated copper wire as existing, testing complete.
Taking down defective centrifugal pump set 30 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing capacity at least for 8 hrs on load, complete all as specified and as directed. (Supply of spare parts shall be measured and paid for separately under respective items here-in-after). Make of Pump : Kirloskar Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 1000 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other then the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only Ball bearing suitable for 30 HP motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC
Supply only coupling bolt with nuts suitable for 30 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling Rubber Bush suitable for 30 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only split casing gaskets suitable for 30 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only shaft sleeves suitable for 30 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only Air cock grease nipple suitable for 30 HP motor pump as per manufacturer's design complete all as specified and as directed.
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 30HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable for 30HP motor pump as per manufacturer's design complete all as specified and as directed.
Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and pipe and fixed for 20 mm dia bore and including taking out unserviceable ball valves complete all as specified and directed.
Preparation of surfaces of sluice valve by brooming down or steel wire brushing scrapping down, smoke shoots moulds, mass efforescent salt, treating oil and greasy spots etc and painting two coats of synthetic enamel paint of approved shade over a coat of red oxide primer for sluice valve 150 mm complete including removing existing paint all as specified and directed.
Excavation for taking out brocken CI/DI pipe line upto 200/150mm dia, cutting of CI/DI pipe line upto 200mm dia at two portion with the help of electrical driven pipe cutter and levelling the cutting face of pipe with the electric driven grinder and then CI/DI welding by electric welding machine, fixing detacheble joint, tail piece etc then concreteting by PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation filling and mass condrete, after repair of same pipe line, returning filling of excavated materials including removal of surplus soil complete all as specified.
Cutting existing road/PCC/Drain for laying of DI/GI or any typeof pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, wide 800mm including making existing surface with PCC 1:2:4 type B1 using 20mm aggregate thickness of concrete is 150mm complete all as specified and directed.
Note :- The tendere shall take into consideration for following points while quoting his rate for this item and the unite rate is deemed be included for :-
(i) Earth work excavation in any type of soil
(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed.
(iii) Removing excavated material to out side MD land
(iv) Laying of any type/any bore of pipe in trenches including taking down any description. Supply of pipe will be measured and paid separately
(v) 150 mm thick PCC 1:2:4 type B1 as in road
Supply only 25 mm outer diameter of pipes in cutting road portion 3 Layer PP-R Polyproplyne random copolymer concealed SDR 7.4 (PN 16 @ 20°C) UV stabilized and antimicrobial fusion welded havIng thermal stability for hot and cold water supply including all PP-R plain & brass threaded polypropyelene random fittings complete Note : The unit rate is included for supply only and cutting existing road , excavation, Laying of any type/any bore of pipe in trenches including taking down any description and 150 mm thick PCC 1:2:4 type B1 as in road will be measured and paid separately
Rotational moulded polythene water storage tank of 500 Ltrs capacity (three layer white colour) cylinderical vertical with closed top including 3 Nos GI check nuts and tank nipple of 25mm bore for inlet and outlet, 25mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball hoisted and fixed in position all as specified in SSR part -I including taking down of old unserviceable tank complete all as specified and directed.
Sluice Valve, Cast Iron body, Stainless Steel Spindle, Gun Metal Rings including Wheel for operation, Flanged and Drilled, suitable for 150 mm dia pipes, confirming to IS - 14846, Class PN -1.6, Long Body type including all Joints with Rubber Gasket and Jointing Materials, Bolts, Nuts, Washer complete including taking down existing UNSV sluice Valve all as specified and as directed.
Drain out existing contaminated water from open well/ dug shallow well of size 7 mtr x 3 mtr depth upto 20 to 35 mtr by pumping with the help of diesel driven pump set of not less than 20 HP and pipe complete, taking out of waste materials/ sludge, loose soil from bottom surface of well upto 2 to 3 mtr depth with the help of lifting trolley and further digging and getting out soil upto 1 mtr depth of bottom surface of well, removing grass and vegetation from inner walls of well including disinfection with high power sodium hypo chlorite liquid of not less than 60% chlorine concentration to disinfect all pathogens and coliform organisms from the wall surfaces of well to make a safe and clean spring in the well complete all as specified and directed by the Engineer-in-Charge.
Drain out existing contaminated water from open well/ dug shallow well of size 11 mtr x 11 mtr depth upto 20 to 35 mtr by pumping with the help of diesel driven pump set of not less than 20 HP and pipe complete, taking out of waste materials/ sludge, loose soil from bottom surface of well upto 2 to 3 mtr depth with the help of lifting trolley and further digging and getting out soil upto 1 mtr depth of bottom surface of well, removing grass and vegetation from inner walls of well including disinfection with high power sodium hypo chlorite liquid of not less than 60% chlorine concentration to disinfect all pathogens and coliform organisms from the wall surfaces of well to make a safe and clean spring in the well complete all as specified and directed by the Engineer-in-Charge.
Drain out existing contaminated water from open well/ dug shallow well of size 20 mtr x 10 mtr depth upto 20 to 35 mtr by pumping with the help of diesel driven pump set of not less than 20 HP and pipe complete, taking out of waste materials/ sludge, loose soil from bottom surface of well upto 2 to 3 mtr depth with the help of lifting trolley and further digging and getting out soil upto 1 mtr depth of bottom surface of well, removing grass and vegetation from inner walls of well including disinfection with high power sodium hypo chlorite liquid of not less than 60% chlorine concentration to disinfect all pathogens and coliform organisms from the wall surfaces and bottom surface of well to make a safe and clean spring in the well complete all as specified and directed by the Engineer-in-Charge.
Drain out existing contaminated water from open well/ dug shallow well of size 4 mtr x 3 mtr depth upto 20 to 35 mtr by pumping with the help of diesel driven pump set of not less than 20 HP and pipe complete, taking out of waste materials/ sludge, loose soil from bottom surface of well upto 2 to 3 mtr depth with the help of lifting trolley and further digging and getting out soil upto 1 mtr depth of bottom surface of well, removing grass and vegetation from inner walls of well including disinfection with high power sodium hypo chlorite liquid of not less than 60% chlorine concentration to disinfect all pathogens and coliform organisms from the wall surfaces of well to make a safe and clean spring in the well complete all as specified and directed by the Engineer-in-Charge.
Drain out existing contaminated water from open well/ dug shallow well of size 9 mtr x 4 mtr depth upto 20 to 35 mtr by pumping with the help of diesel driven pump set of not less than 20 HP and pipe complete, taking out of waste materials/ sludge, loose soil from bottom surface of well upto 2 to 3 mtr depth with the help of lifting trolley and further digging and getting out soil upto 1 mtr depth of bottom surface of well, removing grass and vegetation from inner walls of well including disinfection with high power sodium hypo chlorite liquid of not less than 60% chlorine concentration to disinfect all pathogens and coliform organisms from the wall surfaces of well to make a safe and clean spring in the well complete all as specified and directed by the Engineer-in-Charge.
Note for item No 51 to 55 :- The tenderer shall take into consideration following points while quoting his rate for these items and the unit is rate deemed to be included for :-
(i) The above mentioned job to be done in restricted technical area of Air Force Stn Sulur. The tenderer are advised to visit the site before quoting the tender. On account of security reason no compensation or extra shall be admissible due to any misunderstanding or loss of man-hours.
(ii) Due to acute shortage of water, open wells will be handed over to carry out the job in phase manner by Engineer-in-Charge throughout the currency of the contract.
(iii) The contractor shall be provide dewatering pump of suitable capacity and mobile generator for operation of dewatering by high pressure submersible pump (or) Diesel driven high pressure pump and the rate quoted rate is inclusive of rent/hiring charge complete.
(iv) An necessary T&P to ensure safely of labours like safety jackets, ropes, nets, helmets, gumboots etc required will be the responsibility of the contractor.
(v) The potability of water is to be checked after filling fresh yield after cleaning and if the result is found not within the stipulated range, the cleaning and disinfection of well is to be repeated by the contractor without claiming any extra cost from the deptt.
(vi) Charges for water testing will be measured and paid seperately under respective item.
(vii) Material removed from the tank shall be disposed off at out side MD land.
(viii) Open well/ Dug Shallow well shall be made available for cleaning for a period of 2 days only and contractor has to arrange sufficient labour/ T&P to complete the job with the given period only. or otherwise penality shall be imposed @ Rs 2000/- per day.
(ix) Please note that this penalty is exclusively other than the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract.
(x) The decision of the Accepting Officer in this regard shall be final and binding.
(xi) The unit rate is deemed to be included the cost of removing vegetaion/ grass/ trimming of tree branches etc from atleast 5 mtr surrounding of well and pumping room.
Arrangement of Chemical and bacteriological analysis of drinking water by collecting samples from different sources like UG sumps/ user end taps/ bore wells/ open wells/ etc located in 12 km periphery, collection of samples in sterrilized laboratory bottles/ cans, transportation to authorised Govt laboratory to deposit the samples in stippulated time, including payment of fees, collection and submit of reports to the Engineer-in-Charge complete all as directed.
Note :- (a) Cost of transportations for collection of sterrilized bottles from laboratory, deposition of collected samples in stipulated time, report collectiion after completion of tests, payment of fees to the laboratory for each sample, etc are deemed to be included in the quoted rate. (b) The rate quoted is considered to be for each sample. (c) Sample from different sources to be taken as per time schedule directed by Engineer-in-Charge throughout the currency of the contract. (d) Payment will be made after submission of report from authorised Govt laboratroy only.
Taking down defective centrifugal pump set 25 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing capacity at least for 8 hrs on load, complete all as specified and as directed. (Supply of spare parts shall be measured and paid for separately under respective items here-in-after). Make of Pump : M/s BE Pvt Ltd/ Kirloskar Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 1000 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other then the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only Ball bearing suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC
Supply only coupling bolt with nuts suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling Rubber Bush suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only split casing gaskets suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only shaft sleeves suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only Air cock grease nipple suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable for 25HP motor pump as per manufacturer's design complete all as specified and as directed.
Construction of Valve Chamber of size 900 X 900 X 900 mm internal size suitable for Sluice Valve, with PCC 1:4:8, Type D2, using 40mm graded aggregate for foundation, 230 mm thick Brick work with Fly Ash Bricks in Cement Mortar 1:6, 40 mm thick PCC, 1:2:4, Type B1, using 20mm graded aggregate Coping, rendering in CM 1:4, 15 mm thick including provision of Mild Steel Sheet Cover 3 mm thick with 40 X 40 X 6 mm size Angle Iron frame work embedded in concrete with suitable hinges and locking arrangements including two coat of synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and including necessary earth work excavation in any type of soil etc., removal of surplus soil off the premises complete all as specified.
3-layer PP-R (Polypropylene random copolymer) pipes of 32 mm outer dia of pipes, concealed SDR 7.4 (PN-16 @ 20°C) UV stablised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings, including taking down existing pipe of any description and bore of pipe complete to walls, ceilings or in floors or in trenches etc. of following size all as specified and directed. Make : SFMC, Reliance Industries, KPT
Note :- (a) The unit rate shall be include for taking down existing GI pipe and connections and all fittings as directed.
(b) The unit rate shall be include the cost of short lengths, with all pipe fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc and fixing accssories such as pipe hooks, screws clamps etc
(c ) Wall thickness of pipes shall be all as per IS : 15801
Supply and fixing 32 mm outer dia PP-R Gate Valves (Brass insert) with iron wheel head screwed both ends for iron pipes and including taking out unserviceable Gate valves complete all as specified and directed.
Servicing/ cleaning of water fountain consisting of submersible/ hollow well pump set up to 1 HP and connected accessories like pipe rings/ jets/ nozles/ suction and delivery pipes/ cable and electrical controlls, and any other efforts to make smooth flow of water through the pipes and nozles complete all as directed. Note :- (a) Replacement of unserviceable nozles upto 5 Nos, clamps, welding upto 12 stiches are deemed to be incl in the quoted rate. (b) Repair to the pumpset and replacement of cables will be measured and paid seperately under relevant items.
Removing of acumulated earth of any width and depth up to 30 cm. cleaning/cutting the grass and removing the grass waste to outside MD land. Note :- The unit rate is deemed to be included :- (a) Cutting and filling shall be cleared of shrubs, vegetation, grass bush, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground level. Useful material shall be stacked. (b) Cutting the grass/feilling of trees shall include digging out roots up to 60 cm below the ground level or 14 cm below the formation level, whichever is lower. All holes and hollows formed in the ground digging out of roots shalll be carefully filled up with moorum/red bajri well rammed and levelled.
Disconnecting the delivery pipe line of submersible pump sets of any capacity from water mains to take out by lifting column pipe of 50mm dia alongwith submersible cable and pump set from shallow well of any depth for servicing of submersible pump sets of any capacity at site, re-assembling the column pipe and re-connection of submersible cable with pump set and lowering in the shallow/open well, testing and commissioning all as specified and directed. Note:- (a) The cost of tools and equipments reqd for lifting/ lowering of pipes and pumps are deemed to be incl in the quoted rate.
Flat Three Core PVC Insulated & PVC Sheathed Industrial Cable for Submersible Pump Motors 1100 Volt, conforming to IS 694, 6 sq mm nominal area complete including taking out old unserviceable cable complete all as specified and directed. Make : Havells/ KEI/ Polycab
Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and pipe and fixed for 25 mm dia bore and including taking out unserviceable ball valves complete all as specified and directed.
Supply only 32 mm outer diameter of pipes in cutting road portion 3 Layer PP-R Polyproplyne random copolymer concealed SDR 7.4 (PN 16 @ 20°C) UV stabilized and antimicrobial fusion welded havIng thermal stability for hot and cold water supply including all PP-R plain & brass threaded polypropyelene random fittings complete Note : The unit rate is included for supply only and cutting existing road , excavation, Laying of any type/any bore of pipe in trenches including taking down any description and 150 mm thick PCC 1:2:4 type B1 as in road will be measured and paid separately
Rotational moulded polythene water storage tank of 1000 Ltrs capacity (three layer white colour) cylinderical vertical with closed top including 3 Nos GI check nuts and tank nipple of 25mm bore for inlet and outlet, 25mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball hoisted and fixed in position all as specified in SSR part -I including taking down of old unserviceable tank complete all as specified and directed.
Supply, installation, commissioning and testing of Factory assembled, Floor mounted, free standing, type tested LT Feeder Pillar Panels, with canopy, as per electrical specifications for outdoor installation, to be made of IP65 Polycarbonate modular enclosures. The Enclosures made of Polycarbonate, should be weather/ vermin proof, anti-acid, anti-corrosive, UV resistance in accordance with IEC 61439-1, Fire retardant and Self-extinguishing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960° in accordance with 60695-2-11. Degree of protection against mechanical load should be IK 08 (5 Joule) in accordance with IEC 62262, IP 65 in accordance with IEC 60529 & IEC60439-1, should have Dielectric Properties, RoHS compliant & Halogen free. The manufacturer of boards/panel shall submit a copy of type test reports as per above-mentioned norms from UL/ERDA/CPRI/NABL labs in India. The panels should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosures should be above 200mm for air circulation & to minimize temp rise. 3 phase and neutral 350 amps current carrying capacity copper bus bar insulated with colour coded heat shinkable sleeves with SMC/ DMC insulators, complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 60 cm above ground level, including dismantling and taking out old u/s LT Panel Board and remove from site reconnecting existing LT Cables with new panel board complete all as directed :- (a) MCCB, with thermal magnetic release , 4 Pole, 250 Amps, 36 KA , 415 Volt, 50 Hz - 1 No (incoming) (Make of switch gear :- L&T, Schnieder, ABB). Make of LT Panel/ FPB shall be as mentioned in list of makes (PS)
Dismantling pump and motor of submersible pump set for capacity upto 7.5 HP to carry out repairs and replacements at local workshop, duly replacing worn out parts, applying one coat of spray painting with synthetic enamel paint of existing colour and testing complete all as specified and directed. Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 500 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other then the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only GM Bush.
Supply only sleeve MS key for impeller
Supply only SS coupling bearing.
Supply only oil seal thrust bearing.
Supply only Sand Guard.
3-layer PP-R (Polypropylene random copolymer) pipes of 25 mm outer dia of pipes, concealed SDR 7.4 (PN-16 @ 20°C) UV stablised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings, including taking down existing pipe of any description and bore of pipe complete to walls, ceilings or in floors or in trenches etc. of following size all as specified and directed. Make : SFMC, Reliance Industries, KPT
Note :- (a) The unit rate shall be include for taking down existing GI pipe and connections and all fittings as directed.
(b) The unit rate shall be include the cost of short lengths, with all pipe fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc and fixing accssories such as pipe hooks, screws clamps etc
(c ) Wall thickness of pipes shall be all as per IS : 15801
Supply and fixing 25 mm outer dia PP-R Gate Valves (Brass insert) with iron wheel head screwed both ends for iron pipes and including taking out unserviceable Gate valves complete all as specified and directed.
PVC water storage tank cover suitable for 500 to 1000 ltrs capacity tank with locking arrangement complete including taking down of existing one all as specified and directed
Sluice Valve, Cast Iron body, Stainless Steel Spindle, Gun Metal Rings including Wheel for operation, Flanged and Drilled, suitable for 100 mm dia pipes, confirming to IS - 14846, Class PN -1.6, Long Body type including all Joints with Rubber Gasket and Jointing Materials, Bolts, Nuts, Washer complete including taking down existing UNSV sluice Valve all as specified and as directed.
Integrated solar street light of less than 18W with 3000 lumen and system lumen efficiency of more than 170 lumen per watt. The luminaire shall use highly efficient microcontroller based integrated MPPT charge controller, both charger and driver to be on same board with more than 90% efficiency of both charger and driver. High grade aluminium die-cast housing to ensure good heat dissipation. The luminaire shall have flexi mount of 0 to 15 degree to adapt to certain geography diversity. The luminaire shall be with smart self-diagnosis feature with LED indicators alongwith battery charging and deep discharging out off indications. The system shall use long time maintenance free lithium Ferro Phosphate (Li Fe PO 4) battery with BIS certification. Battery capacity of minimum 170 wh for autonomy of 24 hrs with fully charged battery. The luminaire shall be with hybrid feature (integrated/ seperated) ON-OFF switch, Outer mounting diameter of 48-60 mm. Operating temp range for light engine is 0 to +35 Dep C. operating humidity shall be upto 95%. System lumen output should be atleast 12V DC, 2000 lm. Solar panel module capacity of 12V, 35W Peak Mono-crystalline. Solar cell efficiency with min 12%. LED burning hrs to be 50,000 hrs at L70. Rating of IP 65 and IK 08 to comply with UV stabilized poly carbonate front cover. Colour temp of 5700K and CRI > 70 including taking down existing one all as directed. Make : Philips Cat No BRP 710 LED 30 CW MR HY FDIM 50 Solar or equivalent in Wipro/ Bajaj.
Notes:- (a) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report including BIS certification. (b) The contractor shall submit warranty certificate from manufacturer for minimum 5 years. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract. (d) The contractor shall also submit safety and performance standard compliance of IEC 60598-2-3 for road and street lights, IEC 62109-1 for power converters used in Solar Panel, EN 50530 for MPPT performance evaluation, IEC 61607 for EMC immunity, CISPR 15 for Radio disturbance characteristics, IEC 62133, IEC 61960 and UL 1642 for safety of lithium Ferro Phosphate battery and IEC 61730-1, 2 & IEC 61215 for safety of solar panel module. (e) The rates quoted deemed to be included 6 mtr long MS/ GI pipe of 50mm dia medium grade including necessary excavation, PCC foundation, coping, base plate and bend to shape and size suitable for fixing of above fitting all as specified and directed by Engineer-in-Charge.
Dismantling pump and motor of submersible pump set for capacity upto 10 HP to carry out repairs and replacements at local workshop, duly replacing worn out parts, applying one coat of spray painting with synthetic enamel paint of existing colour and testing complete all as specified and directed. Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 500 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other then the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only GM Bush.
Supply only sleeve MS key for impeller
Supply only SS coupling bearing.
Supply only oil seal thrust bearing.
Supply only Sand Guard.
Supply only 50 mm outer diameter of pipes in cutting road portion 3 Layer PP-R Polyproplyne random copolymer concealed SDR 7.4 (PN 16 @ 20°C) UV stabilized and antimicrobial fusion welded havIng thermal stability for hot and cold water supply including all PP-R plain & brass threaded polypropyelene random fittings complete Note : The unit rate is included for supply only and cutting existing road , excavation, Laying of any type/any bore of pipe in trenches including taking down any description and 150 mm thick PCC 1:2:4 type B1 as in road will be measured and paid separately
Dismantling pump and motor of submersible pump set for capacity 3 HP to 5 HP to carry out repairs and replacements at local workshop, duly replacing worn out parts, applying one coat of spray painting with synthetic enamel paint of existing colour and testing complete all as specified and directed. Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 200 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other then the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only GM Bush.
Supply only sleeve MS key for impeller
Supply only SS coupling bearing.
Supply only oil seal thrust bearing.
Supply only Sand Guard.
50 mm outer dia of pipes 3-layer PP-R (Polypropylene random copolymer) pipes concealed pipes SDR 7.4 (PN-16 @ 20°C) UV stablised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings, including taking down existing pipe of any description complete to walls, ceilings or in floors etc. all as specified and directed. Make : SFMC, Reliance Industries, KPT
Note :- (a) The unit rate shall be include for taking down existing GI pipe and connections and all fittings as directed.
(b) The unit rate shall be include the cost of short lengths, with all pipe fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc and fixing accssories such as pipe hooks, screws clamps etc
(c ) Wall thickness of pipes shall be all as per IS : 15801
Supply and fixing 50 mm outer dia PP-R Gate Valves (Brass insert) with iron wheel head screwed both ends for iron pipes and including taking out unserviceable Gate valves complete all as specified and directed.
Supply, installation, commissioning and testing of Factory assembled, Floor mounted, free standing, type tested LT Feeder Pillar Panels, with canopy, as per electrical specifications for outdoor installation, to be made of IP65 Polycarbonate modular enclosures. The Enclosures made of Polycarbonate, should be weather/ vermin proof, anti-acid, anti-corrosive, UV resistance in accordance with IEC 61439-1, Fire retardant and Self-extinguishing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960° in accordance with 60695-2-11. Degree of protection against mechanical load should be IK 08 (5 Joule) in accordance with IEC 62262, IP 65 in accordance with IEC 60529 & IEC60439-1, should have Dielectric Properties, RoHS compliant & Halogen free. The manufacturer of boards/panel shall submit a copy of type test reports as per above-mentioned norms either from UL/ERDA/CPRI/NABL labs in India. The panels should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosures should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with 01 No polycarbonate IP 65, 9W LED translucent bulk head luminaire, 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with 01 No of 16A 3P IP 65 industrial socket and 01 No of 32A 5P IP 65 industrial socket. 3 phase and neutral 250 amps current carrying capacity copper bus bar insulated with colour coded heat shinkable sleeves with SMC/DMC insulators, complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 45 cm above ground level, including dismantling and taking out old u/s LT Panel Board and remove from site reconnecting existing LT Cables with new panel board complete all as directed :-
M&L Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 25x6mm by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as per specified and as directed.
(a) All Joints should be joined by Exothermic Welding or Brazing. (b) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned. (c) Earth resistance tester shall be provided by the contractor. It should be caliberated from authorised company/ lab. (d) After testing if desired earth vesistance of less than 5 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained. (e) The length of the earth strip upto and including 7.5m is included in quoted rate.
Disconnecting from suction & delivery pipes and electrical connections to carry out repairs and servicing of centrifugal monoblock pumpsets 12.5 HP (Make Kirloskar ), driven by squirrel cage induction motor, 3 ph, 415 volts, AC 50 Hz, cleaning inside motor stator winding, varnishing and drying, duly replacing worn out parts, applying one coat of spray painting with synthetic enamel paint of existing colour, reinstalling on the mounting plinth, reconnceting to suction & delivery lines and electricity source, testing on load and re-commissioning complete all as specified and directed. Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 500 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other then the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only Ball bearing . Make : Tata/SKF/NBC
Supply only coupling bolt with nuts.
Supply only coupling Rubber Bush.
Supply only split casing gaskets.
Supply only shaft sleeves.
Supply only Air cock grease nipple.
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 12.5HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable for 12.5HP motor pump as per manufacturer's design complete all as specified and as directed.
Rectification of existing defective flanged joints with rubber or fibre gasket complete with necessary nuts, bolts and washers for 80 mm dia GI/DI/MS pipes complete all as directed. Note:- a) quoted rates are inclusive of cutting of GI/DI/MS Pipes, jointing materials and preparation of new flanged sockets and refixing the same at existing place. (b) Necessary excavation shall be measured and paid separately under respective items of BOQ
Neptune Engineers and Builders
T C KARUNANITHI
KSR AND COMPANY
kaarthic builders
p.chinnasamy
SUPER COOL
KUMAR AGENCIES
A.GOVINDARAJ
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .