Executive Engineer Sub-Transmission Division Kathu
Office of the Executive Engineer Sub-Transmission Division Kathua
RATE CONTRACT FOR REPAIR AND MAINTENANCE OF 33/11 KV RECEIVING STATIONS AND 33 KV LINES
2020_PDD_98909_1
STD-III/e-NIT/2020-21/06
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
Kathua
As per SBD
5 documents required · 5 mandatory
₹2,000
Executive Engineer STD Kathu
₹50,000
Office of the XEN STD Kathua
16 Oct 2020
25 Jun 2020
21 Sept 2020
25 Jun 2020
19 Sept 2020
25 Jun 2020
25 Jun 2020 - 26 Jun 2020
26 Jun 2020
365 days
Installation, testing and Commissioning of Electronic Relay Overcurrent/Earth Fault of different Make in 11KV VCB Panel
Fabrication, testing and Commissioning of PVC insulated Copper Bus Bar (50 mm x 12 mm) Including nuts and Bolts.
Replacement of Damaged 11 KV Espout Bushing for 11KV VCB Panels of following Make
Vijai
Alind
Beeco Lawrie
Southern
Easun Reyrolle
Alstom
Sudhir
Stelmec
Electric Field
Replacement of 11 KV Vacuum interupters
Vijai
Alind
Southern
Easun Reyrolle
Alstom
Sudhir
Stelmec
Electric Field
Crompton
11KV vacuum Interrupters Housing Assembly (Replacement)
Vijai
Alind
Easun Reyrolle
Alstom
Sudhir
Stelmec
Electric Field
Crompton
Installation, testing and Commissioning of Electronic Relay( Overcurrent/Earth Fault ) C&R TRANSFORMER/LINE PANEL
Tripping Coils 36 V DC (Replacement with Former)
Vijai
Alind
Beeco Lawrie
Alstom
Electric Field
Sudhir
Stelmec
Easun Reyrolle
Crompton
Closing Coils 36 KV DC (Replacement with former)
Vijai
Alind
Beeco Lawrie
Alstom
Sudhir
Stelmec
Easun Reyrolle
Electric Field
Crompton
Replacement of 11 KV CT's Set I/D type cast Resin of various makes Vijai, Alind, BHEL, Beeco Lawrie, ABB, S&S, Alstom, Sudhir, Stelmec, Easun Reyrolle, Crompton
Installation, testing and commissioning of 11 KV CT's I/D type of various types
Installation, testing and commissioning of 11 KV PT's (11 KV/110 V)
33KV OUT DOOR CT Replacement of 33 KV CT's (Installation, testing and Commissioning)
Installation, testing and Commissioning of various 33 KV CT
Checking of oil level, measurment of IR value, filling of oil (if required) and tightning of jumpers etc.
33 KV PT OUT DOOR TYPE
Replacement of 33/110V KV PT ( Installation, testing and Commissioning)
Installation/Testing and Commissioning of 33 KV PT , 20 VA, 3P- 33 KV/110V√3
Checking of oil level, measurment of IR value, filling of oil (if required) and tightning of jumpers etc.
Repairing/Repalcement of 11 KV VCB's
Tripping Mechanism
Modification of mechanism
Re-Setting Links
Replacement of operating shaft
Shower Contact
Isolating Sockets
Closing Mechanism (Replacement)
High Tension Spring
Tripping Shaft
Rollers
Latch Assembly
Overhauling of 11 KV VCB
Deco Spray painting
BMR Mechanism Complete
Alind
Easun Reyrolle
Vijai
Crompton
Jyoti
Stelmec
Sudhir
Electric Field
Setting right of 11 KV VCB (Alind, Easun Reyrolle, Vijai,Crompton,jyoti ,BHEL,S&S,Stelmec,Sudhir,Electric Field)
Installation, Testing and Commissioning of 11 KV Panels equipments/items.
Digital 2 OC & 1 EF Relay (MakeEasun/L&T,Ashida,schnieder,C&S,siemen,micom,ABB)
Voltmeter 11KV/110V
Ampere meter
LED panel Indicators
Push Button
Master Tripping Relay
HRC fuse with Base -16 Amps
Panel Control re-wiring with 2.5 sqmm flexible wire, connecting ribs, bunching wire, ferruling, thimbling etc
Connecting Ribs
Auxilary Switch
Auxilary Relay -30 A
TNC Switch
Trip Circuit Supervision Relay
Electronic Hooter/bell (Replacement)
Annunciator
Antipumping device
33 KV C&R Panel
Repairing of 33 KV C&R Panel
Replacement of Bucholz, Winding Temperature, Oil Temperature, Tripping Relay
Replacement of Bucholz, Winding Temperature, Oil Temperature, Alarm Relay
Replacement of Master Tripping Relay
Replacement of Closing Trip Switch
Panel Control re-wiring with 2.5 sqmm flexible wire, connecting ribs, bunching wire, ferruling, thimbling etc
Deco Spray painting
MW Meter (Replacement)
Energy Meter (Replacement)
Electronic Hooter (Replacement)
Close/ Trip Switch
HRC fuse with Base -1 Amps
HRC fuse with Base -6 Amps
HRC fuse with Base -16 Amps
LED panel Indicators
Push Button
Annunciator
O/C and E/F relay
Restricted E/F relay
Installation, testing and Commissioning of various 33KV C& R Panel(LINE/TRANSFORMER)
Repairing of 33 KV VCB
33 KV Porcelain Insulator (Replacement)
Operating Rods (Replacement)
Closing Coils with Housing (Replacement)
Tripping Coils wih Housing (Replacement)
Motor Charging 240AC
Contactor (Replacement)
Gasket
Operating Shaft
Mechanism Housing
Gear Assembly
Auxillary Switch
Rollers
Charging Rod/Wheels
Replacement of SF6 gas meter
Installation, testing and Commissioning of 66KV SF6 breaker
Setting right of 33 KV VCB breaker (ABB, crompton greaves ,Megawin etc)
33/11 KV Power Tranformer
Topping of oil
Replacement of 33KV Bushing
Replacement of 33KV Bush Rods
Replacement of 11 KV Bushing
Replacement of 11 KV Bush Rods
Installation and fixing of Bi-Metallic Clamps of Bush Rod
Tap Changer Contact Replacement
Tap Changer Contact Repairs
Gasket Set of Bushing
Gasket Set of Tap Changer/Radiators
Male (Replacement)
Female (Replacement)
Dehydration/Filteration of Power Transformer Oil
Buchloz Relay (Replacement)
Winding Temperature Meter with Probe (Replacement)
Repairing of leakage of radiators by way of gas welding
Replacement/Repairing of damaged cooling fans of radiators
Oil Temperature meter With Probe (Replacement)
Transformer neutral Earthing complete with cu Strip
Installation & commissioning of 33/11 kv Power Transformer including assembly fixing of bushes, radiator ,fans(if any), wiring of instrument
1MVA upto and including 2.5 MVA
Above 2.5MVA upto upto and including 6.3 MVA
Above 6.3 MVA upto upto and including 10MVA
Above 10 MVA upto upto and including 20MVA
Above 20MVA
Retrofitted 11KV VCB:-
Modification of Tripping Mechanism with Complete Assembly retrofitted from to new Mechanism of same make duly Modified in Order to Have reliable tripping mechanism as well as smooth operational functionalities.
33KV isolator
Erection of 33 KV isolator without earthing blade including levelling,assembling ,fixing,alignment,testing and making all connections
Erection of 33 KV isolator with earthing blade including levelling,assembling ,fixing,alignment,testing and making all connections
Checking of moving/fixed contacts, cleaning ,greasing of contacts,cleaning of post insulator,auxillary switches contacts ,tightning of clamps
Repair of damaged 33 kvisolator including replacement of mouth, post insulator, damaged blades,isolator pipe etc
33 KV Lightning Arrestor
Erection of 33 KV Lightning Arrestor including levelling,assembling ,fixing,alignment,testing and making all connections
Measurement of IR value, leakage current and tightning of droppers
Eathing Mat
Measurement of earth resistivity, checking of electrical continuity of equipment earthing, tightning of earthing connectors,removal of rust from bolted earth connections and retightning
Installation/Testing and Commissioning of 11 KV Panel
Installation, testing and commissioning of 2' x 10 mm Copper Bus Bar
Installation, testing and commissioning of 100A MCCB with enclosure box
Installation of Enclosure Box for Bus BAr
Battery bank and Battery Charger
Installation, Testing and Commissioning of automatic battery charger with Tickle and Boost Charge
Installation, Testing and Commissioning of DC system 36 V, maintenance free VRLA batteries 200 AH 2 V x 18 no. including its mounting arrangement, wiring and battery terminal holders of required equipment
Repair of Battery Charger
Repair/replacement of Battery cell of 2V 100AH/2V 200AH
11 KV Power cables
Dismantling of damaged cable from the panel and outgoing structure, taking out from cable trench making roll to safer sideoutside and carriage of same to store.Carriage of power cable from store to site of erection laying in the power cable trench, peeling the cable , fixing the earth clamps and fitting the HS cable kit to both ends, fixing to panel and outgoing structure including testing and commissioning.
120mm²(3-core)
185mm²(3-core)
240mm²(3-core)
300mm²(3-core)
400mm²(3-core)
630mm²(single-core)
11 kv Damaged Cable kits
Dismantling of damaged cable from the panel and outgoing structure, taking out from cable trench peeling the cable and removing/cutting damaged cable kit, roving PVC insulation, cleaning of XLPE Insulation, crimping of thimbles, fitting the HS cable kit,laying the power cable in trench ,fixing with nuts and bolts,connecting the earth point of the cable with existing earthing system ,fixing to panel and outgoing structure.complete job testing and commissioning.
120mm²(3-core)
185mm²(3-core)
240mm²(3-core)
300mm²(3-core)
400mm²(3-core)
630mm²(single-core)
Providing , laying and Fixing of 2-core 2.5 sqmm Control Cable Amoured, 1.1 Kv Grade ISI FRLS
Providing , laying and Fixing of 4-core 2.5 sqmm Control Cable Amoured, 1.1 Kv Grade ISI FRLS
Providing laying and Fixing of 8-core 2.5 sqmm Control Cable Amoured, 1.1 Kv Grade ISI FRLS
Providing,laying and Fixing of 12-core 2.5 sqmm Control Cable Amoured, 1.1 Kv Grade ISI FRLS
Replacement of damaged 11 kv Post Insulator or providing additional post insulator
Replacement of 66KV busbar of single condductor with size upto 0.4 sq. inch including replacement of disc insulators, tigtning of clamp, jumpers droppers if required.
Replacement of damaged LED bulbs of control room building and switchyard lighting
11KV Auxillary Transformer
Topping of oil
Replacement of HT/LT bushing
Replacement of HT/LT bush rods
Replacement of HT/LT bushing gaskets
Repair of Auxillary Transformer
Installation of Auxillary Transformer
Augmentation of Auxillary Transformer
Replacement of LT cable 3½ core 120mm² for 11kv auxillary transformer
Installation of new11 KV Outgoing Structure on PCC poles with D.O, set LA and other accessories
Installation of new11 KV Outgoing Structure on ST poles with D.O, set LA and other accessories
Replacement of 11KV D.O set
Replacement of 11KV LA set
Eathing complete with GI pipe & plate
Fencing of Switchyard with Mesh fencing,angle iron post complete along with cement bottoming of angle posts
Providing/installation of damaged/broken windows panes with fibre sheet of control room
Deweeding of vegetation in outer yard
Removing of Stone metal, deweeding of unwanted vegetation, spreading of stone metal collected earlier for removal of vegetation ,levelling of area with existing stone metal
Providing additional stone metal and its carriage and laying in outdoor yard
Repair and maintenance of AC Distribution board,identification of fault in respect of cable and its replacement ,replacement of damaged MCCB,bus bar etc
Repair and maintenance of DC Distribution board,identification of fault in respect of cable and its replacement ,replacement of damaged MCCB,bus bar etc
Painting of internal/external walls and roof with approved brand of distemper , doors and window of control room buiding with paint of approved brand like asian paint,nerolac etc
Fencing of Receiving Station with barbed wire,angle iron post complete along with cement bottoming of angle posts
Repair/Replacement of ceiling fan of control room building
watering of earth pits
cleaning of roof of control room buildings
fixing of window panes
Description of Work / Item(s)
Maintenance of 66 KV lines
Transportation, Erection, testing and commissioning of 16 meter pole including painting one base coat of Red oxide and two coats of alumunium paint of approved brand like asian paint,nerolac
Transportation, Erection, testing and commissioning of 13 meter pole including painting one base coat of Red oxide and two coats of alumunium paint of approved brand like asian paint,nerolac
Transportation, Erection, testing and commissioning of 11 meter pole including painting one base coat of Red oxide and two coats of alumunium paint of approved brand like asian paint,nerolac.
Transportation, Erection, testing and commissioning of 9 meter pole including painting one base coat of Red oxide and two coats of alumunium paint of approved brand like asian paint,nerolac.
Painting of ST poles/Rails including cross arms, clamps with one base coat of Red oxide and two coats of alumunium paint of approved brand like asian paint,nerolac.
Straightening of Tilted 16/13/11/9Mtr ST poles/rail/joist/latice/pcc poles after opening of half pits and refilling after straightening.
Dismentalling and re-Stringing of Loose/snapped conductor.
ACSR Panther
ACSR Dog
Transportation and laying of new conductor in place of old Wornout conductor
ACSR Panther
ACSR Dog
Transportation and laying of new Earth wire in place of old Wornout Earth wire
Re-Fixing of Up-rooted Guys after opening of pits and refilling thereof.
Straightening of Tilted H- Frame after opening of half pits and refilling after straightening.
Erection of guy complete including digging of pit,fixing of guy rod, disposal of excavated soil, collection of stone boulders ,refilling of excavated pits in layers of stone boulder and fine soil , fixing of guy insulator ,guy collar ,adjusting properly turn buckle, stringing screw, tightning after erection
Fixing and transportation of GI wire for earthing of poles complete.
Earthing of Poles with spiral/ MS spikes as per REC standards
Transportation and Erection of Channel Iron Cross arms (100 x 50 x 6 mm) of different lengths duly fabricated
Transportation and erection of Angle Iron Braces,braces (65x 65 x 6mm) of different lengths duly fabricated
Transportation and fixing of Clamps/Collars for X-arms, belts and braces using Flat iron (50 x 6 mm).
Erection of 66 kv disc insulators set of 5 no. with suspension fittings including punching of locking pins complete
Porcelain type
polymer type
Erection of 11 kv disc insulators set of 3 no. with tension fittings including punching of locking pins complete
Porcelain type
polymer type
Restoration of Snapped Earth Wire
Transportation and fixing of 33 KV Isolator with earthing Blade (72.5 KV, 1250 A, Outdoor 3 poles, 25 KA)
Transportation and fixing of 33 KV Isolator without earthing Blade (72.5 KV, 1250 A, Outdoor 3 poles, 25 KA)
Transportation and fixing of 11 KV Isolator with earth switch
Transportation and fixing of 33 kv Lightening Arrestor set
Repair of damaged 66 kvisolator including replacement of mouth, post insulator, damaged blades,isolator pipe etc
Replacement of burnt/damaged jumpers and tightning of jumpers
Transportation and Fixing of 11 KV link Set after dismantling damaged one
Transportation, fixing of Guard netting with 8 SWG GI wire with a minimum of 10 n0. cross pieces per span including to earth on both ends
Clearance of 33 KV Lines by way of cutting down trees, branches etc
Transportation and fixing of Galvanised Nuts and Bolts of various sizes
Transportation and fixing of PG Clamps/Clamps of various Sizes
Cement Bottoming of ST Poles with 1:2:4 Mix (0.45 Cums)
Cement Bottoming of ST Poles with 1:2:4 Mix (0.60 Cums)
Dismentaling of old/Rotten ST/Rail poles complete and Transportation to Divisional store
Dismentaling of old/damaged 11 kv Disc insulators sets of 3 no. with fitting complete Transportation to Divisional store
replacement of damaged 33kv pin insulator
Dismantaling of Worn out conductor and transportation to Divisional Store
ACSR Panther
ACSR Dog
Dismantaling of Worn out Earth Wire and transportation to Divisional Store
Fixing of anticlimbing devices consisting of 12 turns of barbed wire equally spaced over a lengh of 1m above the ground level including clamping at both ends
Route Clearance /Temporary path by way of cleaning bushes and vegetation bushes and vegetation and making temporary path for carriage of line material.
replacement of damaged x-arm 100*50 *50
reerection of uprooted 9mtrs two pole structure
re-erection of uprooted 11 mters two pole structure
re-erection of upropted 9 mtr single pole structure
re-erection of uprooted 11mtrs single pole structure
Description of Work / Item(s)
Maintenance of 66 KV lines
Stage contract for maintenance of 33/11KV Receiving Stations
Stage contract for maintenance of 33KV Lines
VIJAY KUMAR
M/s Wazir Agencies
VIJAY KUMAR
M/s Wazir Agencies
VIJAY KUMAR
M/s Wazir Agencies
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .