Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.6 LAccepted-AOC | ₹44.6 L Quoted ₹49.1 L | L1 | Accepted-AOC Accepted due to lowest rate quoted |
| 2 | L2₹49.5 LRejected-Finance H NO 90 VILLAGE REWLA KHANPUR PO NAJAFGARH NEW DELHI 110043 | NEW DELHI | WEST DELHI | DELHI | 110043 | ₹49.5 L | L2 | Rejected-Finance Rejected due to highest rate quoted |
| 3 | L3₹49.9 LRejected-Finance N A | NEW DELHI | DELHI | 110001 | ₹49.9 L | L3 | Rejected-Finance Rejected due to highest rate quoted |
| 4 | L4₹50.4 LRejected-Finance | ₹50.4 L | L4 | Rejected-Finance Rejected due to highest rate quoted |
| 5 | L5₹51.4 LRejected-Finance | ₹51.4 L | L5 | Rejected-Finance Rejected due to highest rate quoted |
| Sl No | Description | Qty | Unit | M/S GEETANJALI ENTERPRISES L4 | Ish Engineers and Contractors L2 | M/s.sagar enterprises L5 | M/S Rohit Enterprises L3 | ARE ESS ENGINEERING SERVICES L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of Concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level), cement concrete ( un reinforced), etc complete all as spd and directed. | 2.5 | Cum | 200 ₹500 | 100 ₹250 | 500 ₹1,250 | 100 ₹250 | 100 ₹250 |
| 2.00 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc completed all as specified. | 580 | Sqm | 10 ₹5,800 | 29 ₹16,820 | 10 ₹5,800 | 100 ₹58,000 | 5 ₹2,900 |
| 3.00 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, etc completed all as specified. | 308 | Sqm | 15 ₹4,620 | 29 ₹8,932 | 20 ₹6,160 | 100 ₹30,800 | 10 ₹3,080 |
| 4.00 | Demolition of stone slabs and tiles of any description or thickness in floors , aprons etc , laid bedded and pointed in any mortar , et complete all as spd and directed | 4.4 | Xsqm | 50 ₹220 | 299 ₹1,315.60 | 500 ₹2,200 | 100 ₹440 | 100 ₹440 |
| 5.00 | Demolition of brickwork built in cement mortar including all quoins, arches, pillars etc complete all as directed by EIC. | 2 | Cum | 300 ₹600 | 299 ₹598 | 500 ₹1,000 | 100 ₹200 | 100 ₹200 |
| 6.00 | Demolition of reinforced cement concrete as in chimney, Roofs, floors (other than ground floors), beams staircases, landing, chajjas, and similar suspended work complete. | 1 | Cum | 400 ₹400 | 299 ₹299 | 1,000 ₹1,000 | 100 ₹100 | 100 ₹100 |
| 7.00 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.50 Sqm each complete all as specified and as directed by the Engineer-in-Charge | 32 | Each | 100 ₹3,200 | 99 ₹3,168 | 100 ₹3,200 | 150 ₹4,800 | 50 ₹1,600 |
| 8.00 | Taking down, Chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m each but with shutters (without taking off shutters from the frame),etc complete all as spd and directed. | 48 | Each | 100 ₹4,800 | 99 ₹4,752 | 100 ₹4,800 | 150 ₹7,200 | 50 ₹2,400 |
| 9.00 | M&L Roughning surfaces of old concrete floor by picking ,sweeping clean and washing down with water to remove dust etc including brushing neat cement slurry with 3 kg of cement per sqm | 330 | Sqm | 20 ₹6,600 | 159 ₹52,470 | 200 ₹66,000 | 10 ₹3,300 | 10 ₹3,300 |
| 10.00 | M & L for 25mm thick PCC 1:2:4 type BO (using 12.5mm graded stone aggregate) as in sub base floor complete all as specified and directed. | 330 | Sqm | 150 ₹49,500 | 199 ₹65,670 | 200 ₹66,000 | 200 ₹66,000 | 100 ₹33,000 |
Updated dates
Tender Value
₹45.8 L
EMD Value
₹92,000
Closing Date
21 Jan 2026, 6:00 pmClosed
GE (AF) GURGAON
GE (AF) GURGAON
ADDN/ALTN TO CERTAIN MD ACCN AT 503 SU UNDER GE (AF) GURGAON
2025_MES_745942_1
GE/GUR-/NIT-113/2025-26
Open Tender
Civil Works
240 days
GE (AF) GURGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) GURGAON
₹92,000
18 Mar 2026
24 Dec 2025
23 Jan 2026
24 Dec 2025
21 Jan 2026
7 Jan 2026
Demolition of Concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level), cement concrete ( un reinforced), etc complete all as spd and directed.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc completed all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, etc completed all as specified.
Demolition of stone slabs and tiles of any description or thickness in floors , aprons etc , laid bedded and pointed in any mortar , et complete all as spd and directed
Demolition of brickwork built in cement mortar including all quoins, arches, pillars etc complete all as directed by EIC.
Demolition of reinforced cement concrete as in chimney, Roofs, floors (other than ground floors), beams staircases, landing, chajjas, and similar suspended work complete.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.50 Sqm each complete all as specified and as directed by the Engineer-in-Charge
Taking down, Chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m each but with shutters (without taking off shutters from the frame),etc complete all as spd and directed.
M&L Roughning surfaces of old concrete floor by picking ,sweeping clean and washing down with water to remove dust etc including brushing neat cement slurry with 3 kg of cement per sqm
M & L for 25mm thick PCC 1:2:4 type BO (using 12.5mm graded stone aggregate) as in sub base floor complete all as specified and directed.
M & L first quality coloured glazed ceramic, joint free tiles fixed in pattern of different colour including border of Size aera exc 0.15 Sqm but n.exc 0.20 Sqm & 7-8 mm thick as in vertical surfaces such as dado/skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match with colour of tiles laid on and including 10 mm thick rendering in cement mortar (1:3), including pointing in white cement with pigment to match the shade of tiles, complete all as specified and directed. Note :- Pattern of the tiles will be decided by GE at the time of execution.
M&L Coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick Screed bed or bedding layer of mortar for laying floor finishes in CM 1:6
M&L 7 mm to 8 mm thick Joint less light ceramic tiles Ditto but in Dado/Skirting including Rendering 10mm thick in CM 1:4 on fair faces of brick work or concrete surfaces as backing coat. & including taking down plaster & 10 mm thick cement rendering in CM 1: 4 complete all as specified and directed by Engineer-in-Charge.
M&L, Non-skid ceramic coloured tiles, joint free tiles 7 to 8 mm thick (square/rectangular) of area exc 0.11 Sqm but n.exc 0.18 Sqm , in floors etc. set & jointed in neat cement slurry & pointed in white or coloured cement over 15mm thick screed bed in CM (1:6) complete all as specified.
M&L 18-20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including 20mm thick screed bed in CM (1:6) for laying of Granite slab& pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including half moulding of granite edges complete all as specified and directed.
M&L for 75mm thick cement concrete1:3:6 type C1 using 20mm graded stone aggregate as in plinth protection joint filled with bitumen sand mixer 50mm thick finished even and smooth without using extra cement.
M & L for rendering 15 mm thick on other than fair faces of brick wall finished fair & even in CM 1:6 complete all as specified and directed.
M & L for rendering 15 mm thick on fair faces of brick wall with mixing WPC @ 3% by wt of cement finished fair & even in CM 1:4 complete all as specified and directed.
M & L for rendering 10 mm thick on brick or concrete surface of ceiling finished fair & even in CM 1:3 complete all as specified and directed.
M&L for preparation of newly plastered or unplastered/undecorated surface of ceiling and applying two or more coat distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified.
M & L preparation of newly plastered surfaces of wall and applying two coats of OBD over a coat of putty filling including preparation of surfaces on walls as specified and directed .
M&L for preparation(complete removal of existing treatment) of old decorated external wall/ceiling surface of existing treatment by scrapping with Trucare Wall Sander : L-01/H-01 (having mechanical vaccum mechanism) having RPM not less than 1500, sand pad of 80 grit having dia of 7"/9" to make the surface free from dust, loose paint etc or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and applying Two coats of wheather proofing exterior acrylic emulsion paint over priming coat premium quality on wall/ceiling surface including applying 2mm thick wall care putty over disturbed surface during preparation of any reason, sand papering thus make surface smooth upto 4th storey buildings complete all as specified and directed. Note : (a) Stage for Preparation of surfaces shall be got approved from Engg-In-Charge before applying the finishes. (b) Material shall be procured from manufacturer and work shall be got executed through authorised applicator.
M&L Preparing of new surface of wall and applying two coats of exterior emulsion paint over a coat primer on walls complete all as specified and directed by Engineer-in-charge. complete all as specified and as directed by Engineer-in-Charge .
M&L for preparation of plastered or unplastered old decorated surfaces by complete removal of existing treatment by mechanised sander of berger paints or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and filling of holes and cracks with with suitable material like cement or plaster of paris etc and thereafter applying two coat of oil bound distemper on walls. Note : (a) Stage for Preparation of surfaces shall be got approved from Engg-In-Charge before applying the finishes. (b) Material shall be procured from manufacturer and work shall be got executed through authorised applicator.
All as per item No.24 here-in-before but on surfaces of ceiling.
M&L Preparing of old surface of wall and applying two coats of white wash including preparation of surfaces.
M&L for brick work with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6
Taking up or down steel tubing & connections incl cleaning for refixing or removal from site 15mm bore pipe.complete all as specified and directed.
Taking down 20 mm dia GI steel tubing and connection, including cleaning for refixing or removal, completed all as specified and directed.
S&F GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid in floors 15mm bore complete all as specified and directed.
M & L tubes 20 mm bore dia, medium grade, galvanised, with all fitting and fixed complete to walls and ceilings or laid in floos, complete all as specified and directed.
S&F grating doom 100mm dia size with PTMT complete all as specified and directed.
Cutting chases pinning in making good to facing where required and pointing in cement mortar (1:3) for concealed water tubing in brick walls cutting n.exc 10 cm girth. complete all as specified and directed.
M&L for RCC 1:2:4 type B0 (Using 12.5 mm graded stone aggregate)as in chajjas / cooking shelves/ Tank staging platform etc. and the like including 5mm thick rendering in cm 1:3 finished even and smooth without using extra cement to the surface in contact with form surface complete all as specified and as directed by Engineer-in-Charge (The rate quoted by the contractor shall included forform work.)
S & F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape reqd, incl cranking, bending spirally for hooping for columns, hooling ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
S&F in repairs WC squatting pan “Orissa Pattern” of size 580 x 440mm white with integral foot rest (excluding flushing cistern & flush pipe) including connection to trap and to flush pipes etc and cement concrete bedding complete all as specified in SSR and including S&F trap set complete all as specified and directed.
M & L Vitreous china wash down water closet pan, pedestal pattern (EWC) white, including seat cover , fixing bolts connection to trap & to flush pipe fixed in repairs complete all as directed by the Engineer-in-charge.
S&F in repairs PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and incl ball valve float & handle, waste pipe & brackets complete set complete all as specified and directed.
S&F in repair vitreous china pedestal pattern wash hand basin (flat back) white of size 550x400mm including one number chromium plated waste fittings, 32 mm dia, brass with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed, with & including 32 mm dia PVC waste pipe with connector, including cutting for and pinning in ends of brackets complete all as specified.
S&F in repair Stainless steel sink made out of 1.00mm thick sheet for kitchen or laboratory with plug , waste pipe ,washers including cantilever cast iron brackets, connecting union etc overall size 495mm x 420 mm with bowl size 410mm x 330mm x 160 mm complete all as specified
S&F in repairs concealed stop cock type CP with long shank cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends of size 15mm bore. complete all as specified and directed.
S&F in repairs stop cock/angle cock with long shank cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends of size 15mm bore. complete all as specified and directed.
S&F in repairs bib tap, cast copper alloy with capstan head, CP fancy type with long body shank, screwed down with high pressure screwed for iron pipe & fixed 15mm bore, complete all as specified and directed.
S&F in repairs fancy type CP pillar tap single leaver basin mixer without popup waste system with 450 mm long braided hoses cat No DRC-37011B make Jaquar or equivalent out of makes spd in list of makes of any colour for basin 15 mm dia screwed down high pressure with long screwed shank sand fly nuts screwed for iron pipe fixed as in repairs complete all as specified and as directed.
Shelf of PTMT fixed with and including chromium plated brass screws and wooden/ plastic cleates.
S & F for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches, bore of pipe in 75 mm, etc complete all as specifed and directed.
S & F for PVC (SWR) bends any radius, bore of pipe in 75 mm, etc complete all as specifed and directed.
S&F in repair brass chromium plated shower roses with swivel joints, 125 mm size in square with CP long shank arm including fixing to steel pipe or union, complete all as specified and as directed.
S&F PVC connections 15mm size with PTMT nuts of length 450 mm, complete all as specified and as directed.
S & F Brass chromium plated, tubular towel rails 20 mm dia, D- type, 60 cm long between flanges, completed all as specified and directed.
S&F in repair kitchen plate rack stainless steel 1 mm thick of size 60cmx75cm complete fixed to brick/concrete wall, with screw including rawl plug complete all as specified and as directed
S&F powder coated anodized aluminum frame for partition, doors, windows, ventilations with one or more rebates including joining cleat for fixing etc. complete all as specified.
S&F powder coated Anodised aluminium window and ventilator shutters, fixed/side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified.
S&F powder coated aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge.
S & F stainless steel wire cloth 0.56mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tacks or galvanised wire staple.
S & F IN REPAIR Galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tacks or galvanised wire staple.
M&L for 3 mm thick,Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane, etc completed all as specified.
S&F for 4.8/5.0 mm thick sheet glass ordinary quality and glazing each pane n exc 0.50 Sqm fixed with neoprene rubber gasket in aluminium frame work complete all as specified.
Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 100 x 50 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). → Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.c complete all as specified and as directed .
S & F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge),minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.(Note: stainless steel butt hinges and necessary S S screws shall be paid separately)
Pressed steel frames made out mild steel sheet 1.25 mm thick, with size of frame 125 mm x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates etc and applying a shop coat of red oxide primer including providing PCC 1:3 :6 type C-0 using 12.5 mm graded crush stone aggregate for filling back of chowkhats complete all as specified and as directed by the Engineer-in-Charge
Pressed steel frames made out mild steel sheet 1.25 mm thick, with size of frame 105 mm x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates etc and applying a shop coat of red oxide primer including providing PCC 1:3 :6 type C-0 using 12.5 mm graded crush stone aggregate for filling back of chowkhats complete all as specified and as directed by the Engineer-in-Charge
S & F for flush shutters with both sides Matt finish laminate incl leeping on the edges, solid core construction , with block board core and plywood face panels , commercial type on both sides , thickness 30 mm , etc complete all as spd and directed
S & F 35 mm,2nd class hard wood factory made, Glazed and skeleton shutters, open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a);,etc complete all as spd and directed.
S&F 100 mm size butt hinges, medium weight, cold rolled, Stainless steel complete all as specified and as directed by Engineer-in-Charge.
150 mm long Stainless steeel anodized barrel tower bolts of extruded section complete .
125 mm size, Stainless steel anodized handles, cast type complete all as specified and directed by Engineer-In-Charge.
300 mm long Stainless steel sliding door bolt, plate type with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete
S & F 300 mm long Stainless steel ordinary rat tail rod pattern door spring including roller and roller plate complete all as specified and directed by engineer incharge
S & F floor door stopper of aluminium alloy body 140 mm cover plate and tounge , anodized with hard drawn steel spring fixed in repairs
Taking down, easing, adjusting of old wooden shutters of any description exc. 1 Sq,m and not exc. 2 Sq.m each and refixing in same opening after tiling work complete all as directed by EIC.
M&L Preparation of new steel surfaces of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamelled paint over one coat of red oxide primer.
Preparation of new wooden surface and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-In-Charge.
Dismantling water tanks exc 250 & n exc 500 and removing to store,etc completed all as spd and directed.
S&F 500 ltrs rotational moulded polyethylene water storage tanks (cylindrical verical with closed top) hoisted and fixed in position including ball valve of 20 mm dia complete all as specifed and directed.
S & F for Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed, Bore dia of pipe in 20 mm, etc complete all as specifed and directed.
Dismantling Brick tiles or terracing tiles, single layer on roofs, etc complete all as spd and directed.
Demolation of mud in roof any thickness incl plastering & leeping removed complete all as specified and directed by Engineer-in-Charge.
M&L Plain cement concrete (1:2:4) type B-1, using 20 mm graded mechanically crushed stone aggregates as in padding to roof to maintain the required slope and finished the surface even and smooth without using extra cement, complete all as specified
Material and labour 15 mm thick cement plaster in CM (1:4) mixed with WPC as per manufacturer’s instructions @ 150 ml by per bag of cement on concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. Note : WPC shall be measured and paid separately.
Cleaning the surface and made free of dirt, foreign particles, laitance followed by grinding all protrusions to make surface modulated. Thereafter, inspection for cracks on the surface caused by thermal expantion contraction. Cutting the grooves with suitable cutter machine in "v" groove filled with Repair mortar/Microconcrete/General purpose grout as recommended proportionaly as per recommendation of manufacturer.Making of Gollas at all the corners with Polymer modified mortar(1:4 Cement:sand with 3.5% Acylic of cement weigth) and " Supplying and applying High build elastomeric waterproofing coating based on pure, hydrophobic polyurethane, cold applied of spray / brush applied, membrane with an elongation of 280% and tensile strength of 2.7 N/mm2 as per ASTM D 2370, crack bridging ability of 3mm, no leakage upto 5 bars of water pressure as per DIN 1048, min 88 % solid content. The system includes final base preparation, epoxy primer 1:1(Resin:hardner) application with 100 % water dilution and Pure polyurethane application in 2 coats with a total min consumption of 1.25 Kg per SQM .Application should be done with Graco sprayer by a company authorised applicator.
M&L cement 1:2:4, type B0, using 12.5 mm aggregate providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges etc complete all as spd and directed.
S&F mild steel Godrej pattern cupboard with back, sides, top, bottom, 02 shelves & mild steel shutter two leaves with frame , incl necessary fittings of 18 gauge MS sheet with locking arrangement and handle etc all as per Godrej pattern with duplicate keys including necessary fittings & 19mm stainless steel rod for hanging cloths & two coats of spray painting over a coat of red oxide zinc chromate primer complete. The frame of cupboard to be fixed to wall with 6 Nos fastners.The cost of fastners & grouting them is deemed to be included in unit rates complete all as specified and as directed. Note:- Superficial area shall be measured, Approx Size (1150x1920x600mm) .
Supply & Fixing of 18 mm thick Rajshri WPC celluka ply of one side Prelam/Rigidlam and other side balancing laminate colour to make kitchen cabinet shutter/drawer front shutters as per specifications complete all as specified and as directed.
Supply & Fixing of 18 mm thick Rajshri WPC celluka ply of plain colour fixed with screws, solvent cement/adhesive to make kitchen cabinet sides top and bottom and shelves inside the cabinets as per specifications complete all as specified and as directed.
Supply & Fixing of 12 mm thick Rajshri WPC celluka ply of plain white colour fixed with screws, solvent cement/adhesive to make wall mount kitchen cabinet back and pull out drawer sides as per specifications complete all as specified and as directed.
Supply & Fixing of 6 mm thick Rajshri WPC celluka ply of plain white colour fixed with screws, solvent cement/adhesive to make wall mount kitchen cabinet back and pull out drawer sides as per specifications complete all as specified and as directed.
Supply & Fixing of Ball bearing runners 45 mm telescopic channel (20 inch) full extension load capacity 50 kgs complete all as specified and as directed. (Make: Hettich,Ebco,Prime)
S&F 100 mm size Stainless Steel handle complete all as specified and as directed.
S&F 50 mm magnetic catches with brass body and striking plate including letting in and fixed complete all as specified and as directed.
S&F 38mm size Stainless Steel Piano hinges complete all as specified and as directed.
M&L Mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing quality B complete all as specified.
S&F mild steel plain black sheet 0.80 mm thick as in hearths,covering to door shutters , covering to door chowkat etc cut to size edges beaded if directed, holes punched, etc complete all specified and as directed.
S&F repairs stainless steel 100 mm dia with or without hole jointing with solvent
S&F toughened glass 46X13cm make ESS ESS or equivalent chrome finish equivalent complete all as specified.
S&F in repair corner shelf with CP railing 300mm x 300mm complete all as specified
Material and labour 1st quality meteor endure homogeneous vitrified square tiles in approved shade in minimum 12 mm thickness from meteor series, area of each tile exceeding 0.08 sqm but not exceeding 0.10 sqm in floors etc , set & jointed in neat cement slurry & pointed in matching coloured polymer cement based grout to match complete all as specified and directed by Engineer-in-Charge.. Make :Johnson Endura meteor (Korneto Biege) or equivalent.
Demolition of Concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level), cement concrete ( un reinforced), etc complete all as spd and directed.
Providing and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved , design & pattern as in footpath , parks , lawns,drive ways or light traffic parking etc. of required strength , thickness & size/shape, made by table vibratory method using PU mould , laid in required colour & pattern over and including 25 mm thick compacted bed of fine sand , compacting and proper embedding/laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator,filling joints with sand andcutting of paver block as per required size and pattern,finishing and sweeping extra sand.
M & L for 75 mm thick, Cement concrete type D-2, 1:4:8 (40mm graded aggregate), etc completed all as specified.
Cement concrete (1:2:4) type B-0 using 12.5mm graded stone aggregate as in coping including necessary formwork complete all as specified.
Taking down old point wiring complete for light/fan/socket(5/15 Amps) bell point etc complete with all light fittings accessories, such as switch sockets 5/15 Amps ceiling rose etc including making good to the disturbed surface to match with the existing complete all as specified and directed by Engineer-in-Charge.
Taking down existing ceiling fans any size in position and re-fixing the same after B/R work including painting of the same with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. and writing MES Number in black paint with skilled painter, with and including providing three core flexible copper cable for connection from ceiling rose/connector complete all as specified and directed by Engr-in-Charge.
Taking down existing Gysers 25 ltr in position and re-fixing the same after B/R work including painting of the same with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. and writing MES Number in black paint with skilled painter, with and including providing three core flexible copper cable for connection from Metal clad to Gyser complete all as specified and directed by Engr-in-Charge.
Taking down existing single /three phase electric energy meter of any capacity after disconnecting all necessary electrical connections and re fixing the same with elecrical connection, near to SPN DB complete all as specified and as directed.
Taking down carefully exsiting ceiling fan /Exhaust fan of any size, sealing cable end, dismantling blades and removing fan and blades and kept aside and deposited to MES yard.
Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed.
Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :-
One light point control by one switch
One ceiling fan/exhaust fan control by one switch
One 3 pin socket outlet, 5 Amps independent
One 3 pin 5 amps socket outlet on the same board with other switches
One bell/buzzer point contolled by one push button independent
ditto as per item No. 111 above but wire 2.5 sq mm cable for switch socket outlet 3 pin 15 Amps with 2.5 sq mm as earth continuity conductor complete all as specified and directed. (FOR 15 Amps socket point)
ditto as per item No. 111 above but wire 4.0 sq mm cable for switch socket outlet 3 pin 15 Amps with 2.5. sq mm as earth continuity conductor complete all as specified and directed. (FOR geyser/AC point)
S & F Modular switch one way 6 Amps, single pole 240 volts, ISI marked complete all as specified and directed.
Supply and fix ceiling rose three terminal surface bakelite 65/25 mm dia complete all as specified and directed.
S & F Modular socket outlet 2 in 1, 3 pin, 6 Amps complete all as specified and directed.
S&F Modular socket outlet 2 in 1, 3 pin, 6 and 16 Amps flush type, 240 Volts, ISI marked complete all as specified and directed.
S&F Modular switch, flush type single pole 16 Amps
S&F call bell multi music type, AC 230 Volts, single pole complete all as specified and directed.
Supply and fixing Modular bell push flush type 6 Amps, single pole, ISI marked complete all as specified and directed.
S & F for Highly efficient LED Bulbs, 10 watts in B-22 cap complete all as specified and directed. Make Bajaj, Havells, HPL
Supply and fixing Inverter LED batten with squre profile 20 Watt and polycarbonate channel . Lithium lon battery with bcharging time 8 hourse -10 hourse and back up time upto 4 hours. with extruded environmental friendly, energy efficient with three core flexible copper conductor cable of suitable size from ceiling rose complete with all connected accessories all as specified and directed. Make :Havells LHEXACP7FN1W020 or equivalent make of Bajaj / Philips / syska/Crompton/ Shakti as approved by GE.
Supply and fixing in repair lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Supply and fixing LED tube light fitting mirror type with high output diffuser 2 feet, 10 watts 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. Make : Havells/Philips/Crompton/Wipro
S & F for Decorative wall mounting, brushed nickel finish fixture with Opal Glass diffuser suitable with 7 W LED lamp B22 base and including fixing of LED bulb 7 watts complete all as specified and as directed. Make Havells Cat No LHFOAJE1TZ1I060 or its equivalent in Philips, Wipro, Havells,Shakti.
S & F LED light fitting 1 x 9 W/ 1 x 10 W bulkhead luminaired including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. Make : Havells/Philips/Crompton/Wipro
S & F for ceiling fan, 230 Volts, 50Hz, 1200 mm sweep with down road 15mm/12mm upto two mtr or as per site requirement canopy, blades, BLDC motor etc and service value of the fan shall be greater than 6.1 as per BIS with necessary accessories and electrical connections with remote and battery , from ceiling rose to fan teriminal including writting the MES Number with synthetic enamel paint complete all as specified and as directed.Make Havells Cat Part No FHCNF5SWHT48,Cropmton, Usha
Supply and fixing modular stepped type electronic fan regulator flush type
Supply and fix in repair single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed.
Supply and Fix in repairs flush mounting factory made Vertical FP DB, IP-43 Protection -IK 09 with metal double door with 200 Amps rated copper busbar with 2 neutral bar, earth bar and cables ties for cable management fully insulated bus bar with set of wires and door earthing with provision of sapce for 100-125 amps MCCB as incomer and SPN/TP MCBs as out going, 4 way (Optium 1+12 Module) including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour complete all as specified and directed by Engr-in-Charge.
S & F for sheet metal enclosure MCB DB SPN 12 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S&F MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA
Supply and fixing 240V 10KA 'B' SP 6 to 32 Amps curve miniature circuit breake (MCB) and current carrying capacity in the DB complete with connection testing and commissioning
Supply and fixing 32 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of two poles and current carrying capacity in the MCB DB complete with connection testing and commissioning
Supply and fix heavy duty single phase, steel body exhaust fan 300 mm sweep, 900 RPM complete with shutter and louvers and exhaust fan shall be fixed with suitable size of buzzer bolt/hold fastener as approved by Engr-in-charge complete all as specified and directed.
Supply & fix plastic body exhaust fan, AC single phase 230/ 240 V of size 250/200 mm sweep with louver ,white in colour including cutting of wall and duly connection with copper wire from ceiling rose etc complete all as specified and directed. Make: Havells Model Ventil Air-DX White or equivalent in Crompton/Almonard/Havells
S & F in repair sub main wiring for circuit of size 6 sq mm 2 core (FRLS) alongwith earth wire of 6 sq mm single core of FRLS PVC insulated unsheathed cable, 1100 volts grade with multistranded copper conductor including PVC conduit (conealed wiring) of suitable size complete all as specified and directed by Engr-in-Charge. (FOR SPN DB's & energy meter)
S & F in repair sub main wiring for circuit of size 4 sq mm 2 core (FRLS) alongwith earth wire of 2.5 sq mm single core of FRLS PVC insulated unsheathed cable, 1100 volts grade with multistranded copper conductor including PVC conduit (conealed wiring) of suitable size complete all as specified and directed by Engr-in-Charge. (FOR SPN DB's & energy meter)
Supply and fixing in repair LED bldg security light fitting 35 watts 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including suitable size of GI bracket for mounting of security light to be bend as required shape, pipe bracket shall be made as per direction and site requirement and suitable size 02 Nos MS clamps and nuts and bolts. Make : Havells/Philips/Wirpo
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc
S & F for Modular type TV Socket out let complete all as specified and as directed.
S & F for Modular type telephone RJ 11 socket outlet complete all as specified and direced.
S & F for PVC non-metallic rigid conduit ISI marked heavy duty white/ Ivory colour and its accessories heavy duty ISI marked of size 20 mm dia for telephone and TV connections including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed.
Supply and fix and testing for anti suicide fan road 12 inch if the load on fan exceeds 22 kg , than the smartm rod / pice opens from its centere and spring in the pipe expands. Thus any one trying to hang from fan comes down safely complete all as specified and directed.
M&L for earthing to LT panel board/TPN DB with mild steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) connected to galvanised earth lead wire 4.0 mm dia by means of galvanised iron nuts, bolts and washer, earth lead connected to eqpt as directed, earth plate surrounded with adequate quantity of charcoal dust mixed with common salt to a packed thickness of 15 cm all around the plate including necessary earth work, PCC chamber and reinforced PCC cover made by PCC 1:3:6 type C-1 as in pit chamber and RCC pit cover 50 mm thick precast RCC 1:2:4 type B-1 duly reinforced with 6mm dia MS bar at 150mm c/c both ways with 10 mm dia MS round bar as handle, 20 mm bore GI pipe medium grade for watering and 15 mm dia GI pipe light grade for protection of earth lead up to 7.5 mtr with funnel, wire mesh etc with and including testing complete all as specified and as shown in electrical plate No 3 of MES sch Part I.
Supply and laying in repair and testing cable XLPE insulated, screned, PVC bedded galvanized steel strip or wire amoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core
Excavation in trenches in hard/dense soil not exc. 1.5 metre wide and n'exc. 1.50m deep for laying cables/pipes/poles and getting out complete all as specified and directed.
Returning filling including spreading leveling watering and well ramming in layers not exc 25Cm in soft/ loose soil, complete all as specified and directed.
Removing excavated material in hard/dense soil n'exc 50M and depositing where directed at a level n'exc1.5M above the starting point, complete all as specified and directed.
M&L for sand cushning to U/G cable in layers of 23cm thick( 8 Cm before laying the cable and 15Cm thick after laying the cable) in trenches including watering and consolidation, complete all as specified and directed.
Supply and lay well burnt brick class B of size 250 x 110 x 75 mm as protection to cable in cable trenches all as specified and directed
Taking down old u/s LT UG cable of size 10 sq mm 2 core complete all as specified and directed.
Supply laying and jointing GI pipe 'light grade' 40 mm bore in trenches/under floors or roads/ along poles/ on wall incl clamps for protection of cables incl fittings complete all as specified and directed.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
TenderDocuments113.pdf
Tender Documents • 0.62 MB
BOQ_835250.xls
BOQ • 0.67 MB
Download all tender documents and submit your bid