| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.0 LAccepted-AOC 840 1B MADHUR VIHAR COLONY CIVIL LINES JHANSI UP 284 001 | JHANSI | JHANSI | UTTAR PRADESH | 284001 | L1 | Accepted-AOC being L1 bidder | |
| 2 | L2₹28.1 L+₹97,770 (3.60%)Rejected-Finance | L2 | Rejected-Finance not become lowest bidder | |
| 3 | L3₹32.2 L+₹5.1 L (18.6%)Rejected-Finance 34 35 ASHOKA ESTATE NEAR S S PUBLIC SCHOOL SEWLA SARAI AGRA 282001 | AGRA | UTTAR PRADESH | 282001 | L3 | Rejected-Finance not become lowest bidder | |
| 4 | L4₹32.6 L+₹5.4 L (19.9%)Rejected-Finance | L4 | Rejected-Finance not become lowest bidder | |
| 5 | L5₹33.8 L+₹6.6 L (24.5%)Rejected-Finance | L5 | Rejected-Finance not become lowest bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
13 Sept 2024, 6:00 pmClosed
Major Sunny Kumar Attri
Garrison Engineer Jhansi
PETTY REPAIRS PERTAINS TO E/M WORKS FOR ZONE C AND D AREA UNDER AGE E/M AT GE JHANSI
2024_MES_667784_1
GE/JHA/TOK/69 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE Jhansi
As per NIT and Tender Documents
9 documents required · 9 mandatory
₹500
Yes
GE Jhansi
₹90,000
Yes
7 Oct 2024
24 Jul 2024
16 Sept 2024
24 Jul 2024
13 Sept 2024
6 Aug 2024
24 Jul 2024 - 5 Aug 2024
Amount
Attending daily complaints of Jhansi Mil area by deputing adequate number of Skilled team of qualified Electrician and helper at any point of time for repair, maintenance and making the continuity of electric supply. After rectifying the defects of the electrical system revoke elecric supply via means of thimbling , tighten loose connection including provisioning of small pieces of electrical cables PVC insulated copper multistranded conductor of sizes 1.5 Sqmm to 6 Sqmm single core and length not increasing 0.50 mtrs complete all as specified and directed by Engr-in-Charge. Note:- (i) Contractor shall be fully responsible for Complaint slip/ Job card prepared and submitted on daily basis ( Format as provided by the Engineer in Charge. Complaint slip shall be part of the RAR/bill (ii) This item pertains to attending complaints of light/fan/power point, MCB DB including other minor items such as insulating tape, screws etc as required to attend the complaint to the entire satisfaction of user/Engr-in-Charge. (iii) Items required for replacement shall be measured and paid seperately under respective item of Sch 'A'
Supply and fix in replacement fan capacitor 2.5 m.f.d for ceiling Fan, incl taking down old unserveable capacitor all as specified and directed.
Supply and fix in replacement fan capacitor 4 m.f.d for Exhaust Fan,incl taking down old unserveable all as specified and directed.
Taking down carefully existing copper/aluminium point wiring (light, fan, socket or power) complete of any description wooden boards, laminated sheets from sunken boxes, boards, shades light fitting etc and making good the disturbed surfaces of walls, floors, ceiling etc with cement plaster, putty and paint to match with the existing surface complete all as specified and directed.
M&L for Point wiring with 1.5 Sqmm FRLSH insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core conforming to IS:694 along with one run of 1.5 Sqmm FRLSH insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of electrogalvanised steel terminal box of thickness not less than 18 SWG / with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated ISI marked sheet fixed with brass/GI screws for mounting switches, sockets, fan regulator, etc. complete all as specified and directed for the following points:-
One light / ceiling fan / exhaust fan / call bell point controlled by one switch
One 6A socket point controlled by one switch on independent board
One 6A socket point controlled by one switch on same board
All as per item No. 5.00 here-in-before but one 16A socket point controlled by one 16A switch on independent board with 2.5 sqmm wires.
All as per srl item No 5 here-in-before but with 4 sq mm FRLSH copper wire with 4 Sqmm FRLSH copper earth wire for one 16 Amp socket point controlled by one 16 Amp switch on independent board.
All as per item No. 5.00 here-in-before but with 2.5 Sqmm one 16A socket point controlled by one 16A switch on independent board but just below / above the existing socket points / DBs up to one meter distance in the same vertical plane.
M&L for point wiring with 1.5 Sqmm PVC insulated FRLSH, unsheathed, copper conductor stranded 1100 volt grade cable in & incl PVC trunking of size not less than 32x12mm ISI marked ivory white with all accessories such as tee, bend, joint cover including electrogalvanised steel sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and PVC laminated ISI marked top cover 3.0 mm thick for mounting of switches/ sockets/ regulator etc and PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green. Make -
One light / ceiling fan / exhaust fan / call bell point controlled by one switch
One 6A socket point controlled by one switch on independent board
One 6A socket point controlled by one switch on same board
All as per item No. 6.00 here-in-before but one 16A socket point controlled by one 16A switch on independent board with 2.5 sqmm wires.
All as per srl item No 6.00 here-in-before but with 4 sq mm FRLSH copper wire with 4 Sqmm FRLSH copper earth wire for one 16 Amp socket point controlled by one 16 Amp switch on independent board.
All as per item No. 6.00 here-in-before but one 16A socket point controlled by one 16A switch on independent board but just below / above the existing socket points / DBs up to one meter distance in the same vertical plane.
M&L for sub main wiring along with earth wire with FRLSH insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for the following sizes:- (Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length)
2 runs X 2.5 Sqmm + 1 run X 2.5 Sqmm. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length
2runs x 4 sqmm(Ph & N) + 1run x 4 sqmm(earth wire) Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length
2runs x 6 sqmm(Ph & N) + 1run x 6 sqmm(earth wire) Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length
2runs x 10 sqmm(Ph & N) + 1run x 10 sqmm(earth wire) Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length
M&L for sub main wiring along with earth wire with FRLSH insulated copper conductor, single core cable drawn through in & incl PVC trunking of size not less than 32x12mm ISI marked ivory white and its all accessories complete including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for the following sizes:- (Note: Three runs of copper cable and one run of PVC trunking shall be measured as one unit length)
2runs x 4 sqmm(Ph & N) + 1run x 4 sqmm(earth wire) (Note: Three runs of copper cable and one run of PVC trunking shall be measured as one unit length)
2runs x 6 sqmm(Ph & N) + 1run x 6 sqmm(earth wire) (Note: Three runs of copper cable and one run of PVC trunking shall be measured as one unit length)
Notes for item No. 5.00 to 8.02 : (i) Quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface. (ii) If any beam / column / Rock wall is encountered while cutting chases, that particular portion may be provided with PVC casing & capping or surface conduit for drawing cables and surface PVC gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) No cutting shall be done on ceiling for laying PVC conduit for ceiling fan point wiring. Surface conduit or PVC casing capping may be used in that portion.
S&F of Switch piano type, single pole, one way, 6 amps, 240 volts, complete all as specified and directed.
S&F of Switch piano type, single pole, one way, 16 amps, 240 volts, complete all as specified and directed.
S&F of electronic fan regulator in 5 steps, 240V, 50Hz complete all as specified and directed.
S&F of Socket 5 pin, 6 Amp, universal type, 240 volts, complete all as specified and directed.
S&F of Socket, 6 pin, 6/16 Amp, multipurpose 240 volts, complete all as specified and directed.
S&F of Modular switch 1 way 6A, 1 module 240V, 50Hz complete all as specified and directed.
S&F of Modular switch 1 way 16A, 1 module 240V, 50Hz complete all as specified and directed.
S&F of Modular fan regulator step type in 5 steps, 240V, 50Hz complete all as specified and directed.
S&F of Modular Socket, 6A - 2/3 pin combined 2 module 240V, 50Hz complete all as specified and directed.
S&F of Modular Socket 6A/16A - 2/3 pin combined 2 module 240V, 50Hz complete all as specified and directed.
S&F of Modular blank plate 1 module complete all as specified and directed.
S&F of Lamp holder, angle type with metal ring, PVC/Polycarbonate body complete all as specified and directed.
S&F of Ceiling rose, three terminals, bakelite body, 240 volts, complete all as specified and directed.
Notes for item No. 10 to 22 : If these items are fixed in replacement the cost of same is deemed to be included in the quoted rates.
S&F in replacement of integrated LED batten 10 watt, 2 feet long, full white in Engineering plastic batten with white acrylic cover with built-in electronic driver, pre-wired and connecting up with twisted twin core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed.
S&F in replacementof integrated LED batten 20 watt, 4 feet long, full white in Engineering plastic batten with white acrylic cover with built-in electronic driver, pre-wired and connecting up with twisted twin core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed.
S&F in replacement of integrated LED batten 20 watt, 4 feet long, Tri light (cool white, warm white & Morning white) combination of these in Engineering plastic batten with white acrylic cover with built-in electronic driver, pre-wired and connecting up with twisted twin core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed.
S&F in replacementof LED bulkhead luminaire 10W in die-cast aluminium alloy/ PVC body heat resistant prismatic glass cover, with specially designed gasket for minimum IP 55 degree of protection complete all as specified and directed by Engineer-in-Charge.
S&F in replacementof LED street/security light fitting 30 watts with high efficiency long life LEDs with In-built electronic driver and surge protection upto 10 Kv complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP66 degree of protection including provision of GI pipe bracket made up of 25mm dia medium grade GI pipe of length 1.50m bent to required shape and fixing on walls with suitable MS clamps(02Nos) made up of 25mmx4mm MS flat, nuts, bolts and washers and provision of 3 core twisted flexible copper cable of size 0.5 sqmm from ceiling rose to connector of fitting complete all as specified and as directed.
S&F in replacement of LED street/security light fitting 45 watts with high efficiency long life LEDs with In-built electronic driver and surge protection upto 10 Kv complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP66 degree of protection including provision of GI pipe bracket made up of 25mm dia medium grade GI pipe of length 1.50m bent to required shape and fixing on walls with suitable MS clamps(02Nos) made up of 25mmx4mm MS flat, nuts, bolts and washers and provision of 3 core twisted flexible copper cable of size 0.5 sqmm from ceiling rose to connector of fitting complete all as specified and as directed.
S&F in replacement of LED post top lantern light fitting 20watts with high efficiency long life LEDs with In-built electronic driver and surge protection upto 10 Kv and complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP65 degree of protection including provision of 25mm dia medium grade GI pipe of length 0.50m bent to required shape and fixing on ground/walls with pcc 1:2:4 using 20 mm size stone aggregate upto 30 cm and provision of 3 core twisted flexible copper cable of size 0.5 sqmm from ceiling rose to connector of fitting complete all as specified and as directed.
S&F in replacement of sleek round recessed cum surface mounting LED down light 12 W with aluminium die-cast body, finish with drop down PC diffuser warm / full white with optimized heat sink for efficient dissipation complete all as specified and directed.
S&F in replacement of Decorative wall light fixture made up of Polycarbonate with and including 7W retrofit LED lamp, full white/ Warm white of approved model complete all as specified and directed.
S&F in replacement LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type (Cool white & warm white) with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling/grid ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type (Cool white & warm white) gypsum ceiling with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of LED Step Bollard light having step profile placed on top ideal for architectural outdoor lighting typically giving off light from the sides suitable to illuminate walkways, steps or pathway with rated power 10 W cat ref LLGBL-10-W or eqivalent complete all as specified and directed.
S&F in replacement of Edge Recess round panel ultra slim recess -mounting round LED downlighter light 6 W with aluminium die-cast body, finish with drop down PC diffuser warm / full white with optimized heat sink for efficient dissipation complete all as specified and directed.
S&F in replacement LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
S&F in replacement of modular MCB protected plug and socket board in sheet steel enclosure with 25A rated mini MCB and 20A rated 3 pin plug, 240 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed.
S&F in replacement sheet metal enclosures SPN 12 Way AC single phase, 240 volt with suitable rated bus bar for double door IP-42 complete all as specified & directed. Note: MCBs shall be measured and paid separately.
All as per item No. 39 here-in-before but SPN, 8 way, 230 V, 1 phase, AC Note: MCBs shall be measured and paid separately.
All as per item No. 39 here-in-before but SPN, 4way, 230 V, 1 phase, AC Note: MCBs shall be measured and paid separately.
S&F of MCB 63A, 10 KA, TPN, 415 V, 50 Hz complete all as specified and directed.
S&F of MCB 40A, 10 KA, SPN, 'C' curve, 240 V, 50 Hz complete all as specified and directed.
S&F of MCB 6 - 32A, 10 KA, single Pole, 'C' curve, 240 V, 50 Hz complete all as specified and directed.
S&F of call bell ding dong, AC, 240V, 50Hz complete all as specified and directed.
S&F of Modular Bell Push , flush type, 6Amp, 1 module 50Hz complete all as specified and directed.
S&F of Bell Push , flush type, 5 Amp 50Hz complete all as specified and directed.
Taking down exhaust fan of any sweep, cleaning the fan completely of dust and dirt and Re- fixing the same back to its original positions including connecting with three core flexible copper wire to ceiling rose etc complete all as specified and directed by Engr-in-Charge.
Supply and fix of ventilating fan with plastic body with louvers, 200mm sweep, single phase, 230 volts, 50 Hz. Complete all as specified and directed.
Supply and fix of ventilating fan with plastic body with louvers, 250mm sweep, single phase, 230 volts, 50 Hz. Complete all as specified and directed.
S&F in replacement of 3mm thick phenolic laminated hylam sheet of size 9" X 11" including necessary cutting, drilling holes for fixing of switches, sockets & fan regulators etc and fixing the hylam sheet on existing metal flush box with brass/GI screws with washers complete all as specified and directed. Note: S&F of switches, sockets & regulators shall be measured and paid separately.
S&F in replacement of 3mm thick phenolic laminated hylam sheet of size 8" X 5" including necessary cutting and drilling holes for fixing of switches, sockets & fan regulators etc as per site requirement and fixing the hylam sheet on existing metal flush box with new brass/GI screws with washers complete all as specified and directed. Note: S&F of switches, sockets & regulators shall be measured and paid separately.
Supply and fix in replacement of 3mm thick phenolic laminated hylam sheet of size 5" X 5" including necessary cutting and drilling holes for fixing of switches, sockets & fan regulators etc as per site requirement and fixing the hylam sheet on existing metal flush box with new brass/GI screws with washers complete all as specified and directed by Engineer-in-Charge. Note: S&F of switches, sockets & regulators shall be measured and paid separately.
Taking down old unserviceable of LT cable of any size complete all as specified and directed by Engr-in-Charge.
Supply and fix of 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor twin core, 10 sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections including connecting on LT OH line / energy meter / DB etc complete all as specified and directed.
Supply and fixing in replacement PVC conduit including fitting such as tee,elbow,bend etc 20mm dia ISI (MMS)grade, incl taking down old unserviceable conduit all as specified and directed.
Supply and fixing in replacement PVC cassing Capping tee,elbow,bend etc 20/25 mm dia ISI ISI (MMS) incl taking down old unservecable cassing capping all as specified and directed.
S&F in replacement of Deep Recess - mounting COB LED downlights nucleus Deep Recess 10W made of extruded aluminium housing and high lumen LED as a light source with clear diffuser and separate electronic driver complete all as specified and directed.
Supply and fixing in replacment electronic adapoter for LED light up to 30 watt including takingdown old unserviceable electronic adaptor of LED as per sample Make CG or equivalent in : Havells/Bajaj/Philips.
Supply and fixing in replacement modular cover plate with frame 4 module type for fixing of modular switch socket, regulators, blank plates etc incl dismentaling old unserviceable cover plate complete all as specified and directed.
Supply and fixing in replacement modular cover plate with frame 8 module type for fixing of modular switch socket, regulators, blank plates etc incl dismentaling old unserviceable cover plate complete all as specified and directed.
Supply and fixing in replacement electronic driver as per sample for LED fitting up to 45 watt incl taking down old unserviceable driver . Make Crompton/Havells/CG/Philips/Osram.
Supply and fix in replacement 2-Watt LED Wall Light (bed light) for reading incl taking down old UNSV light all as specified and directed by Engr-in-charge make Philips 30975 or equivalent in Havells/ crompton etc.
supply and fix in replacement Spot light 6 Watts Black/ white Body LED Spot Light, Focus Light (Warm White) incl taking down old UNSV ligh all as specified and directed by engr-in- charge. Make CG CAT NO 211 - 06 - 40 - SL - NWH or equivalent in Philips/CG/Bajaj
Supply and fixing PVC insulated and unsheathed FRLS H single core multistranded copper conductor for repair, in existing conduit of size 1.5 sqmm as in replacement of any defective/burnt circuit incl taking down old UNSV cable complete all as specified and directed.
Supply and fixing repair PVC insulated and unsheathed FRLS H single core multistranded copper conductor for repair, in existing conduit of size 2.5 sqmm as in replacement of any defective/burnt circuit.incl taking down old UNSV cable complete all as specified and directed.
Supply and fixing repair PVC insulated and unsheathed FRLS H single core multistranded copper conductor for repair, in existing conduit of size 4.0 sqmm as in replacement of any defective/burnt circuit.incl taking down old UNSV cable complete all as specified and directed.
Supply and fixing repair PVC insulated and unsheathed FRLS H single core multistranded copper conductor for repair, in existing conduit of size 6.0 sqmm as in replacement of any defective/burnt circuit.incl taking down old UNSV cablecomplete all as specified and directed.
S & F Street light bracket made out of medium grade GI Pipe, bent to shape including GI Clamps nut,bolts washers,reducer of required size for suitable any type fittings etc complete including necessary painting and taking down old UNSV GI Bracket all as specified and directed by Engr-in Charge.
M & L in replacement GLS Coloured Lamp Red,Green,Milky,0-60 Watt complete all as specified and directed. Make Philps/Havells/WIPRO
S & F in replacement LED Bulb threaded types in holders 0 to 15 Watts as per existing sample given by department complete all as specified and directed. Make Havells/Wipro/Legarnd
S & F in replacement LED Bulb brown in brightness(Warm tpye) 0 to 15 Watts as per existing sample given by department. complete all as specified and directed. Make Havells/Wipro/Legarnd
S & F in replacement LED Bulb 9 Watts as per existing sample given by department.complete all as specified and directed. Make Havells/Wipro/Legarnd
M&L to attend major/ minor fault/ No Light due to any reason like neutral fail or short cicuit complete including petroling or rectfication of complaint etc. and rectifying the fault by tightening the cable connections and making the electric supply functional complete all as specified and directed by Eng-in-Charge.
Taking down fan, sealing cable end,dismantling blades and removing fan and blades to store or repair and refixing in same position including connector from ceiling rose to fan connector complete all as specified and directed.
Taking down exhaust fan and refixing and connecting up including provision of cable from ceiling rose to connector to fan complete all as specified and directed.
M/s Sohanil Construction (BID ID -3077219)
M/S SHARADA ASOCIATE (BID ID -3092907)
JAI BALAJI CONSTRUCTIONS (BID ID -3089663)
M/S AADI TRADERS (BID ID -3090446)
Dhruv Enterprises (BID ID -3090582)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .