Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.6 CrAdmitted-Finance AT ROAD BOKAKHAT ASSAM | ₹8.6 Cr | L1 | Admitted-Finance |
| 2 | L2₹9.0 Cr+₹40.2 L (4.66%)Admitted-Finance | ₹9.0 Cr+₹40.2 L (4.66%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S. M.P. AGARWALLA L1 | Rantu Baruah L2 |
|---|---|---|---|---|---|
| 1.00 | Passenger Terminal Building (Civil + Plumbing Works)
EARTH WORK
Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m.
All kinds of soil. | 492 | Sqm | 40 ₹19,680 Lowest | 40 ₹19,680 Lowest |
| 2.00 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including
getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
All kinds of soil. | 285 | Cum | 220 ₹62,700 | 200 ₹57,000 Lowest |
| 3.00 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | 189 | Cum | 230 ₹43,470 | 220 ₹41,580 Lowest |
| 4.00 | Excavating,spplying,stacking and filling of local earth (including royalty)by meachanical transport upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20cm in foundation trenches,plinth,sides of foundation etc.complete for all lift. | 127.09 | Cum | 750 ₹95,317.5 Lowest | 800 ₹1,01,672 |
| 5.00 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. | 35 | Cum | 2,400 ₹84,000 | 2,200 ₹77,000 Lowest |
| 6.00 | Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20% | 3 | Litre | 260 ₹780 | 250 ₹750 Lowest |
| 7.00 | Diluting and injecting chemical emulsion for post construction anti termite treatment Treatment of soil under floors and apron using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the Plinth level : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration | 226.95 | Sqm | 350 ₹79,432.5 Lowest | 350 ₹79,432.5 Lowest |
| 8.00 | CONCRETE WORK Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. 1:3:6 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) | 68 | Cum | 7,500 ₹5,10,000 Lowest | 7,500 ₹5,10,000 Lowest |
| 9.00 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing :1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). | 3.66 | Cum | 10,500 ₹38,430 Lowest | 10,500 ₹38,430 Lowest |
| 10.00 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast
40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. | 46 | Sqm | 800 ₹36,800 Lowest | 800 ₹36,800 Lowest |
Tender Value
₹7.9 Cr
EMD Value
₹15.7 L
Closing Date
12 Apr 2024, 2:00 pmClosed
Chief Engineer (Roads), PWRD, Assam
O/o the Chief Engineer Roads, PWRD, Assam, Chandmari, Guwahati, 781003
SOPD_G_23_24_74 Development of Heliport at Geleki of Golaghat District, Assam under SOPD (G) for the year 2023-24.
2024_PWD_37463_1
No. CE/DEV/TB/1369/2023-24/03
Open Tender
Civil Works
Item Rate
365 days
Golaghat
Please refer Tender documents.
4 documents required · 4 mandatory
₹15,710
₹15.7 L
Yes
O/o the Chief Engineer Roads, PWRD, Assam,
12 Jul 2024
28 Mar 2024
12 Apr 2024
28 Mar 2024
12 Apr 2024
5 Apr 2024
28 Mar 2024 - 4 Apr 2024
4 Apr 2024
Amount
Passenger Terminal Building (Civil + Plumbing Works) EARTH WORK Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m. All kinds of soil.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Excavating,spplying,stacking and filling of local earth (including royalty)by meachanical transport upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20cm in foundation trenches,plinth,sides of foundation etc.complete for all lift.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for post construction anti termite treatment Treatment of soil under floors and apron using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the Plinth level : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
CONCRETE WORK Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. 1:3:6 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing :1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification work in doses by weight of cement as per manufacturer's specification
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
R.C.C. WORK Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improveworkability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately) All works upto Plinth level concrete of M25 grade with minimum cement content of 330 kg/cum
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately) All works above plinth level upto floor V level concrete of M25 grade with minimum cement content of 330 kg/cum
Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars
Centering and shuttering including strutting, propping etc. and removal of form for : Foundation, footing, bases of columns etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors,roof,landing,balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for : Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like
Centering and shuttering including strutting, propping etc. and removal of form for : Weather shade, Chajjas, corbels etc., including edges
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
BRICK WORK Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth level up to floor V level in all shapes and sizes in : a) Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : a) Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
CLADDING WORK Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab upto 0.50 sqm
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab over 0.50 sum.
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
WOOD WORK Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete. 300x16 mm
FLOORING Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. for flooring Size of Tile 600x600 mm for flooring
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. For Flooring
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacture in all colours and shede in skirting,riser of steps,laid with cement based high polymer modified quick set tile adhesive ( water based )confirming to IS 15477 in average 6mm thickness including grouting of joints ( payment for grouting of joints to be made separately ). Size of Tile 600x600 mm
Kota stone slabs 20mm thick in risers of steps,skirting,dado and pillars laid on 12mm ( average ) thick cement mortor 1:3 ( 1 cement : 3 coarse sand ) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete.
62mm thick cement concrete flooring with concrete hardner topping,under layer 50mm thick cement concrete 1:2:4 ( 1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size ) and top layer 12mm thick cement hardner consisting of mix 1:2 ( 1 cement hardner mix : 2 graded stone aggregate.6mm nominal size ) by volume,hardening compound mixed @ 2 lit per 50 kg of cement or as per manufacture's specification.This includes cost of cement slurry,but excluding the cost of nosing of steps etc.complete
ROOFING Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. GI Metal ceiling Lay in perforated Tegular edge global white color tiles of sie 595x595mm
FINISHING 12 mm cement plaster of mix : 1:6 (1 cement : 6 coarse sand)
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Painting with aluminium paint of approved brand and manufacture to give an even surface. Two or more coats on new work
Paiting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade. Two or more coats on new work over an unde coat of suitable shade with ordinary paint of approved brand and manufacture
ALUMINIUM WORKS Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete.
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With brass cover plate minimum 1.25 mm thickness
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.
Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge. Anodized (AC 15 ) aluminium tubular handle bar
Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 8 mm thickness
STRUCTURAL GLAZING Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings, the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in- Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).
Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part- III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bimetallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured
WATERPROOFING Grading roof for water proofing treatment with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size )
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87- 0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/ 250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3mm thick
Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to thewoven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation.
Chequerred precast cement concrete tiles 22 mm thick in foot path on 20 mm thick bed of cement mortar (1:4). Dark shade using ordinary cement
ROAD WORK Supplying and stacking of hard stone ( for stone ptching ) 22.5cm thick at site
Dry stone pitching 22.5cm thick laid in courses and required proile with hammer dressed stone having no side less than 15 cm with minimum depth of 20cm including preparing the bedding surface etc.all complete.
Steel Work Steel work welded in built up sections / framed work including cutting,hoisting,fixing in position and applyinga priming coat of approved steel primer using structural steel etc.as required In grating,frames,guard bar,ladder,railing,brackets,gates and similar works.
SANITARY INSTALLATIONS Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore
Providing and fixing toilet paper holder : C.P. brass
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
Providing and fixing of CP brass Health faucet with 8mm dia 1mtr. Long PVC tube and wall hook fixed to wall with rawl plug and CP brass screws complete. (Make: Jaquar Cat. No.(ALD-CHR-573) or equivalent make as approved by Engineer-in-Charge)
Prividing and Fixing 1.5 feet long connecting hose with nuts at both ends complete.(Make: Jaquar Cat.No.(ALD-CHR-805B) or equivalent make as approved by Engineer-in-Charge) for health faucet
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm
Providing and fixing J shaped Sink Cock (Make: Jaquar Cat.No.(5347N) or equivalent make as approved by Engineer-in-Charge)
WATER SUPPLY INTERNAL Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 40 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 50 mm nominal dia Pipes
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
SOIL, WASTE, VENT & RAIN WATER PIPES Providing and fixing in position uPVC SWR floor trap conforming to IS:13592 including providing necessary steel support and as per Specification. Making proper connection cutting chase / hole in floors / slabs and bringing the same in proper condition and shape after placing the trap in right position complete as required. The hopper and trap shall be set in cement concrete mix 1:2:4 complete as required. (P/S trap) Make: Astral/Ashirvad/Prince or equivalent as approved by engineer-in-charge. (110X110mm)
Providing and fixing uPVC SWR Pipes class B (IS:13592) with all injection moulded fittings complete including jointing with solvent cement including cutting and making good the walls wherever required. (For Rain water pipes). Nothing extra will be paid for supports.(Inside Toilets, Kitchen).Make: Make: Astral/Ashirvad/Prince or equivalent as approved by engineer-in-charge. 160 mm outer dia
Providing and fixing uPVC SWR Pipes class B (IS:13592) with all injection moulded fittings complete including jointing with solvent cement including cutting and making good the walls wherever required. (For soil & waste pipes). Nothing extra will be paid for supports.(Inside Toilets, Kitchen).Make: Make: Astral/Ashirvad/Prince or equivalent as approved by engineer-in-charge. 110 mm outer dia
Providing and fixing uPVC SWR Pipes class B (IS:13592) with all injection moulded fittings complete including jointing with solvent cement including cutting and making good the walls wherever required. (For soil & waste pipes). Nothing extra will be paid for supports.(Inside Toilets, Kitchen).Make: Astral, Ashirvad & Prince 75 mm outer dia
Providing, laying and fixing P.V.C. pipe of ---- dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Inside Toilets).Make: Astral, Ashirvad & Prince 40 mm outer dia
Providing and Fixing in position UPVC ultra violet stabilized 110mm outer diameter cowl dome confirming to I.S.4985 including making joints with solvent cement etc.complete.Make: Astral, Ashirvad & Prince
Providing and Fixing in position UPVC ultra violet stabilized 75mm outer diameter cowl dome confirming to I.S.4985 including making joints with solvent cement etc.complete. Make: Astral, Ashirvad & Prince
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand) including testing of joints etc.complete : 150 mm dia. R.C.C. pipe
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard sign: Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With Sewer bricks conforming to IS : 4885
Constructing brick masonry manhole in cementmortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design: Extra for depth for manholes : Size 90x80 cm With Sewer bricks conforming to IS : 4885
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design: Extra for depth for manholes : Size 120x90 cm With Sewer bricks conforming to IS : 4885
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 150 x 100 mm size P type
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) :
Fire Station Building EARTH WORK Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m. All kinds of soil.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Excavating,spplying,stacking and filling of local earth (including royalty)by meachanical transport upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20cm in foundation trenches,plinth,sides of foundation etc.complete for all lift.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for post construction anti termite treatment Treatment of soil under floors and apron using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm iameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the Plinth level : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
CONCRETE WORK Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification work in doses by weight of cement as per manufacturer's specification.
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of loth lightly soaked in kerosene oil.
R.C.C. WORK Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from ansit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of ncrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately) All works upto Plinth level concrete of M25 grade with minimum cement content of 330 kg/cum
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately)- All works above plinth level upto floor V level concrete of M25 grade with minimum cement content of 330kg/cum
Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars
Centering and shuttering including strutting, propping etc. and removal of form for : Foundation, footing, bases of columns etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors,roof,landing,balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for : Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like
Centering and shuttering including strutting, propping etc. and removal of form for : Weather shade, Chajjas, corbels etc., including edges
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured
BRICK WORK Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth level up to floor V level in all shapes and sizes in : a) Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : a) Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
CLADDING WORK Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab upto 0.50 sqm
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab over 0.50 sum.
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. ncluding moulding, rubbing and polishing of cut edges etc. complete.
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
FLOORING Kota stone slab flooring over 20mm ( average ) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab- cement mortor 1:4 ( 1 cement : 4 coarse sand ) 25mm thick
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. for flooring Size of Tile 600x600 mm for flooring
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ sqm including grouting the joints with white cement and matching pigments etc.,mplete. For Flooring
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacture in all colours and shede in skirting,riser of steps,laid with cement based high polymer modified quick set tile adhesive ( water based )confirming to IS 15477 in average 6mm thickness including grouting of joints ( payment for grouting of joints to be made separately ). Size of Tile 600x600 mm
Kota stone slabs 20mm thick in risers of steps,skirting,dado and pillars laid on 12mm ( average ) thick cement mortor 1:3 ( 1 cement : 3 coarse sand ) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete.
62mm thick cement concrete flooring with concrete hardner topping,under layer 50mm thick cement concrete 1:2:4 ( 1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size ) and top layer 12mm thick cement hardner consisting of mix 1:2 ( 1 cement hardner mix : 2 graded stone aggregate.6mm nominal size ) by volume,hardening compound mixed @ 2 lit per 50 kg of cement or as per manufacture's specification.This includes cost of cement slurry,but excluding the cost of nosing of steps etc.complete
ROOFING Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. GI Metal ceiling Lay in perforated Tegular edge global white color tiles of sie 595x595mm
FINISHING 12 mm cement plaster of mix : 1:6 (1 cement : 6 coarse sand)
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Painting with aluminium paint of approved brand and manufacture to give an even surface. Two or more coats on new work
ALUMINIUM WORKS For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete.
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With brass cover plate minimum 1.25 mm thickness
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.
Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge. Anodized (AC 15 ) aluminium tubular handle bar
Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
WATERPROOFING Grading roof for water proofing treatment with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size )
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87- 0.89 kg/litre and viscocity 70-160 cps. Over the primer coat the layer ofmembrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3mm thick
Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to thewoven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with ntermittent touch by heating the membrane by Butane Torch as per manufactures recommendation.
Chequerred precast cement concrete tiles 22 mm thick in foot path on 20 mm thick bed of cement mortar (1:4). Dark shade using ordinary cement
ROAD WORK Supplying and stacking of hard stone ( for stone ptching ) 22.5cm thick at site
Dry stone pitching 22.5cm thick laid in courses and required proile with hammer dressed stone having no side less than 15 cm with minimum depth of 20cm including preparing the bedding surface etc.all complete.
SANITARY INSTALLATIONS Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore
Providing and fixing toilet paper holder : C.P. brass
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, eighing not less than 105 gms.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
Providing and fixing of CP brass Health faucet with 8mm dia 1mtr. Long PVC tube and wall hook fixed to wall with rawl plug and CP brass screws complete. (Make: Jaquar Cat. No.(ALD-CHR-573) or equivalent make as approved by Engineer-in-Charge)
Prividing and Fixing 1.5 feet long connecting hose with nuts at both ends complete.(Make: Jaquar Cat.No.(ALD-CHR-805B) or equivalent make as approved by Engineer-in-Charge) for health faucet
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm
Providing and fixing J shaped Sink Cock (Make: Jaquar Cat.No.(5347N) or equivalent make as approved by Engineer-in-Charge)
WATER SUPPLY INTERNAL Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 40 mm nominal dia Pipes
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
SOIL, WASTE, VENT & RAIN WATER PIPES Providing and fixing in position uPVC SWR floor trap conforming to IS:13592 including providing necessary steel support and as per Specification. Making proper connection cutting chase / hole in floors / slabs and bringing the same in proper condition and shape after placing the trap in right position complete as required. The hopper and trap shall be set in cement concrete mix 1:2:4 complete as required. (P/S trap) Make: Astral/Ashirvad/Prince or equivalent as approved by engineer-in-charge. (110X110mm)
Providing and fixing uPVC SWR Pipes class B (IS:13592) with all injection moulded fittings complete including jointing with solvent cement including cutting and making good the walls wherever required. (For Rain water pipes). Nothing extra will be paid for supports.(Inside Toilets, Kitchen).Make: Make: Astral/Ashirvad/Prince or equivalent as approved by engineer-in-charge. 160 mm outer dia
Providing and fixing uPVC SWR Pipes class B (IS:13592) with all injection moulded fittings complete including jointing with solvent cement including cutting and making good the walls wherever required. (For soil & waste pipes). Nothing extra will be paid for supports.(Inside Toilets, Kitchen).Make: Make: Astral/Ashirvad/Prince or equivalent as approved by engineer-in-charge. 110 mm outer dia
Providing and fixing uPVC SWR Pipes class B (IS:13592) with all injection moulded fittings complete including jointing with solvent cement including cutting and making good the walls wherever required. (For soil & waste pipes). Nothing extra will be paid for supports.(Inside Toilets, Kitchen).Make: Astral, Ashirvad & Prince 75 mm outer dia
Providing, laying and fixing P.V.C. pipe of ---- dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Inside Toilets).Make: Astral, Ashirvad & Prince 40 mm outer dia
Providing and Fixing in position UPVC ultra violet stabilized 110mm outer diameter cowl dome confirming to I.S.4985 including making joints with solvent cement etc.complete.Make: Astral, Ashirvad & Prince
Providing and Fixing in position UPVC ultra violet stabilized 75mm outer diameter cowl dome confirming to I.S.4985 including making joints with solvent cement etc.complete. Make: Astral, Ashirvad & Prince
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design: Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With Sewer bricks conforming to IS : 4885
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design: Extra for depth for manholes : Size 90x80 cm With Sewer bricks conforming to IS : 4885
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 150 x 100 mm size P type
Utility Building EARTH WORK Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m. All kinds of soil.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Excavating,spplying,stacking and filling of local earth ( including royalty)by meachanical transport upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20cm in foundation trenches,plinth,sides of foundation etc.complete for all lift.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for post construction anti termite treatment Treatment of soil under floors and apron using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the Plinth level : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
CONCRETE WORK Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. 1:3:6 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing :1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification work in doses by weight of cement as per manufacturer's specification
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
R.C.C. WORK Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately) All works upto Plinth level concrete of M25 grade with minimum cement content of 330 kg/cum
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330kg/cum. Excess/less cement used as per design mix is payable/recoverable separately) All works above plinth level upto floor V level concrete of M25 grade with minimum cement content of 330 kg/cum
Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars
Centering and shuttering including strutting, propping etc. and removal of form for : Foundation, footing, bases of columns etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors,roof,landing,balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for : Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like
Centering and shuttering including strutting, propping etc. and removal of form for : Weather shade, Chajjas, corbels etc., including edges
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
BRICK WORK Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth level up to floor V level in all shapes and sizes in : a) Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : a) Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
CLADDING WORK Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab upto 0.50 sqm
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab over 0.50 sum.
Providing & fixing stone slab with table rubbed,edges rounded and polished of size 75x50 cm deep and 1.8cm thick fixed on parapet top by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 6mm nominal size ) as per direction of Engineer in charge and finished smooth. Granite stone of approved make
FLOORING Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. for flooring Size of Tile 600x600 mm for flooring
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacture in all colours and shede in skirting,riser of steps,laid with cement based high polymer modified quick set tile adhesive ( water based )confirming to IS 15477 in average 6mm thickness including grouting of joints ( payment for grouting of joints to be made separately ). Size of Tile 600x600 mm
Kota stone slab flooring over 20mm ( average ) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab. cement mortor 1:4 ( 1 cement : 4 coarse sand ) 25mm thick
ROOFING Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. GI Metal ceiling Lay in perforated Tegular edge global white color tiles of sie 595x595mm
FINISHING 12 mm cement plaster of mix : 1:6 (1 cement : 6 coarse sand)
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Painting with aluminium paint of approved brand and manufacture to give an even surface. Two or more coats on new work
Paiting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade. Two or more coats on new work over an unde coat of suitable shade with ordinary paint of approved brand and manufacture
ALUMINIUM WORKS For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete.
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With brass cover plate minimum 1.25 mm thickness
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.
Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge. Anodized (AC 15 ) aluminium tubular handle bar
Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
WATERPROOFING Grading roof for water proofing treatment with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size )
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87- 0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/ 250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3mm thick
Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to thewoven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation.
Chequerred precast cement concrete tiles 22 mm thick in foot path on 20 mm thick bed of cement mortar (1:4). Dark shade using ordinary cement
ROAD WORK Supplying and stacking of hard stone ( for stone ptching ) 22.5cm thick at site
Dry stone pitching 22.5cm thick laid in courses and required proile with hammer dressed stone having no side less than 15 cm with minimum depth of 20cm including preparing the bedding surface etc.all complete.
Steel Work Supplying and fixing rolling shutters of approved make ,made of required size M.S.Laths,interlocked together through their entire length and jjointed together at the end by end locks,mounted on specially designed pipe shaft with brackets,side guides and arrangement for inside and outside locking with push and pull operation complete,including the cost of providing and fixing necessary 27.5cm long wire springs manufactured from high tensile steel wire of adeuate strength confirming to IS.4454 PART 1 and m.s.top cover of required thickness for rolling shutters. 80x1.25mm m.s.laths with 1.25mm thick top cover
Providing & fixing ball bearing for rolling shutters
Steel work welded in built up sections / framed work including cutting,hoisting,fixing in position and applyinga priming coat of approved steel primer using structural steel etc.as required In grating,frames,guard bar,ladder,railing,brackets,gates and similar works.
RAIN WATER PIPES Providing and fixing uPVC SWR Pipes class B (IS:13592) with all injection moulded fittings complete including jointing with solvent cement including cutting and making good the walls wherever required. (For soil & waste pipes). Nothing extra will be paid for supports.(Inside Toilets, Kitchen).Make: Make: Astral/Ashirvad/Prince or equivalent as approved by engineer-in-charge. 110 mm outer dia
Pavement EARTH WORK Earth work in excavation by mechanical means ( Hydraulic excavator )/manual means over areas ( exceeding 30 cm in depth,1.5m in width as well as 10 sqm on plan ) including getting out and disposal of excavated earth lead upto 50m and for all lift as directed by Engineer in charge. All kinds of soil.
Excavating,spplying,stacking and filling of local earth ( including royalty)by meachanical transport not exceeding 20cm in foundation trenches, plinth, sides of foundation etc.complete for all lift.
Supplying and filling in plinth with sand under floors,including walering, ramming, consolidating and dressing complete.
CONCRETE WORK Extra tor addition of synthetic Polyester triangular fibte of length 12mm. Bffectivo diameter '10-40 microns and specific gravity of 1.34 to 1.40 in cement oncrele/RCC /Flooring/water retaining structures by using 125gms of synthetic Polyester triangular fibre for 50 Kg cemont used as per directions of Engineer-in. Charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work upto plinth level. 1:4:8 ( 1 cement : 4 coarse sand zone II derived from natural sources,8 graded stone aggregate 40mm nominal size derived from natural sources
R.C.C. WORK Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete
Reinforcement for dowel bars including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars
ROAD WORK Preparation and consolidation of sub grade wilh power road roller of 8 to 12 tonne capacity after excavating earth to an average ol 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and ra-rolling tho sub grade and disposal of surplus earth with lead upto 50 metres.
Extra for compaction of earth work in embankment under optimum moislure conditions to give at least 95% of the maximum dry density (proctor density).
Providing and applying tack coat using bitumen emulsion conforming to lS: 8887, using emulsion pressure distributer including preparing tho surface & cleaning with mechanical broom. With medium setting bitumen emulsion On W.B.M / W.M.M. @ 0.4kg/sqm
Providing and applying tack coat using bitumenEmulsion conforming to lS: 8887, using emulsion pressure distributer including preparing the surfaca & cleaning with mechanical broom. With medium setting bilumen emulsion On biluminous surface @ 0.25kg /sqm
Providing and laying Dense Graded Bituminous Macadam Using Crushed Stone aggregates of specified grading. Premixed with bituminous binder and filler, transporting the hot mix to work site by tippers,laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled vibratory and tandem rollers as per specifications to achive the desired compaction and density.Complete as per specifications and directions of Engineer -In -Chrage. 50-100mm averge compact thickness with bitumen of grade VG-30 @ 5.5 % (percentage by weight of total mix) and lime filler @3% (Percentage by weight by agreegate) prepared in Batch Type hot mix plant of 100-120TPH capacity.
Providing and laying Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler transporting the hot mix fo. wark site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and densily as per specification, complete and as per directions of Engineer-in-Charge. 40/50 mm compacted thickness with bitumen of grade VG-30 @ 5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity.
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver] finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10) tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in Charge.
Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-incharge, ic cleaning the surface of all dirt, scales, oil, grease and other foreign material etc. and lining out complete. New work (Two or more coats)
Painting road surface marking with adequate nos of coals to give uniform finish with ready mixed road marking paint conforming to IS : 164, on bituminous surface in white/yellow shade, including cleaning the surface of all dirt, scales, oil, grease and foreign material etc. complete. New Work (Two or more coats)
providing and laying 60 mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm "thick” compacted bed of coarse sand, filing the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
Granular Sub-Base with Coarse Graded Material (Table:- 400-1 & 400-2) Construction of granular subbase by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface to required gradient, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve at least 98% of maximum dry density (determined using Modified Prcctor Test), to achieve atleast 30% of CBR Value, complete as per Clause 401 of MORTH 5th Revision. For Grading (iii) Material
Dry Lean Cement Concrete Sub-base:- Construction of dry lean cement concrete Sub-base over a prepared sub-grade with coarse and fine aggregate conforming to 1S:383, aggregate gradation after blending to be as per Table 600-1 of MORTH 5th Revision, with minimum cement content of 150 kg/cum or as per mix design (whichever is more), Concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-12 tonnes vibratory roller, finishing and curing. Complete as per direction of Engineer-in-charge.
Providing and laying design mix cement concrete of M-30 grade in road/taxi tracks/runways,using cement concrete as per design mix,using coarse sand and graded stone aggregate of 40mm nominal size in approprite propoertions as per approved & specified design criteria,providing dowel bars with sleevel/tie bars wherever required,laying at site,spreading and compacting mechanically by using needle and surface vibrators,levelling to required slope/camber,finishing with required texture,including steel form with sturdy M.S.Channel sections,curing,making provision for contraction/expansion,construction & longitudinal joints ( 10mm wide x 50mm deep ) by groove cutting machine,providing and filling joints with approved joint filler and sealants,complete all as per direction of Engineer in charge ( Item of joint fillers,dowel bars with sleeve/tie bars to be paid separately ) Cement concrete prepared with batch mixing machine.
Extra for providing and laying in position site batched design mix of cement concrete of M40 grade with minimum cement content of 390 kg/cum.
Providing and fixing pre moulded joint filler in expansion joints of RCC /CC pavements after making the joints dust free with high pressure air jet cleaners,all complete as per direction of the Engineer in charge.( Pre moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having ompresnation more than 35% confirming to IS 1838 for fibre board and IS 1834 for hot sealing bitumen compound grade A )
Supplying and stacking of hard stone (for stone ptching ) 22.5cm thick at site
Dry stone pitching 22.5cm thick laid in courses and required proile with hammer dressed stone having no side less than 15 cm with minimum depth of 20cm including preparing the bedding surface etc.all complete.
Drain EARTH WORK Earth work in excavation by mechanical means ( Hydraulic excavator )/manual means over areas ( exceeding 30 cm in depth,1.5m in width as well as 10 sqm on plan ) including getting out and disposal of excavated earth lead upto 50m and for all lift as directed by Engineer in charge. All kinds of soil.
Filling available excavated earth(excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
CONCRETE WORK Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work upto plinth level. 1:4:8 ( 1 cement : 4 coarse sand zone II derived from natural sources,8 graded stone aggregate 40mm nominal size derived from natural sources
FINISHING WORK of 12 mm cement plaster of mix 1:6 (1 cement : 6 coarse sand)
DRAINAGE Providing and fixing in position precast RCC manhole cover and frame Rectangular shape 600x450 mm internal dimension
BRICK WORK Brick work with F.P.S. bricks of class designation 7.5 in foundation and plinth in cement mortor 1:6 : a) Cement mortar 1:6 (1 cement : 6 coarse sand)
Under Ground Water Tank EARTH WORK Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m. All kinds of soil.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil.
Extra for every additional lift of 1.5m or part thereof in excavation / banking excavated or stacked materials
CONCRETE WORK Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. 1:3:6 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
R.C.C. WORK Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately) All works upto Plinth level concrete of M25 grade with minimum cement content of 330 kg/cum
Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars
Centering and shuttering including strutting, propping etc. and removal of form for : Foundation, footing, bases of columns etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors,roof,landing,balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for : Walls ( any thickness ) including attached pilasters,butteresses,plinth and string courses etc.
FINISHING 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).
WATERPROOFING Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC sructures like retaining walls of the basement,wter tanks,roof slabs,podiums,reservoir,sewage & water treatment plant,tunnels/subway and bridge deck etc. For vertical surface two coats
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC sructures like retaining walls of the basement,wter tanks,roof slabs,podiums,reservoir,sewage & water treatment plant,tunnels/subway and bridge deck etc. For horizontal surface one coats
Grading roof for water proofing treatment with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size )
Providing and placing in position suitablr PVC water stops confirming to IS : 12200 for construction expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc.complete. Dumb bell central bulb ( 180mm wide 8mm thick )
ROAD WORK Supplying and stacking of hard stone ( for stone ptching ) 22.5cm thick at site
Dry stone pitching 22.5cm thick laid in courses and required proile with hammer dressed stone having no side less than 15 cm with minimum depth of 20cm including preparing the bedding surface etc.all complete.
FLOORING WORK Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete
Providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manifacture ) of 1st quality confirming to IS : 15622 of approved make in colours such as white,Ivory,Grey,Fume Red Brown,laid on 20mm thick cement mortor 1:4 ( 1 cement : 4 coarse sand ) jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc.complete.
DRAINAGE Providing and fixing in position pre cast R.C.C.manhole cover and frame of required shape and approved quality. Rectangular shape 600x450 mm integral dimensions
STEEL WORK Structural steel work riveted,bolted or welded in built up sections,trusses and framed work including cutting,hoisting,fixing in position and applying a priming coat of approved steel primer all complete.
Supplying and fixing of Padler flanges of 100mm dia. As per approved design as directed by Engineer in charge
Over Head Water Tank EARTH WORK Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m. All kinds of soil.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m
CONCRETE WORK Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. 1:3:6 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
R.C.C. WORK Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately) All works upto Plinth level concrete of M25 grade with minimum cement content of 330 kg/cum
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately) All works above plinth level upto floor V level concrete of M25 grade with minimum cement content of 330 kg/cum
Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars
Centering and shuttering including strutting, propping etc. and removal of form for : Foundation, footing, bases of columns etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilever
STEEL WORK Structural steel work riveted,bolted or welded in built up sections,trusses and framed work including cutting,hoisting,fixing in position and applying a priming coat of approved steel primer all complete.
WATER SUPPLY Providing and placing on terrace ( at all floor levels)polyethylene water storage tank,IS : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank.
Chain link fencing EARTH WORK Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m. All kinds of soil.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil.
Excavating,spplying,stacking and filling of local earth (including royalty)by meachanical transport upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20cm in foundation trenches,plinth,sides of foundation etc.complete for all lift.
CONCRETE WORK Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. 1:3:6 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
R.C.C. WORK Centering and shuttering including strutting, propping etc. and removal of form for : Foundation, footing, bases of columns etc. for mass concrete
STEEL WORK Steel work welded in built up sections / framed work including cutting,hoisting,fixing in position and applyinga priming coat of approved steel primer using structural steel etc.as required In grating,frames,guard bar,ladder,railing,brackets,gates and similar works
FINISHING Applying priming coats with ready mixed zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even surface Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
ROAD WORK Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10cm length and drilled holes upto 10mm dia. etc.complete.
Providing and fixing G.I.chain link fabric fencing of required width in mesh size 50x50mm including strengthening with2mm dia.wire or nuts,bolts and washers as required complete as per the direction of Engineer in charge made of G.I.wire of dia.4 mm PVC coated to achieve uter dia not less than 5mm in required colour and shade
Main Gate EARTH WORK Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m. All kinds of soil.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m
CONCRETE WORK Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. 1:3:6 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
R.C.C. WORK Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately) All works upto Plinth level concrete of M25 grade with minimum cement content of 330 kg/cum
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately) All works above plinth level upto floor V level concrete of M25 grade with minimum cement content of 330 kg/cum
Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars
Centering and shuttering including strutting, propping etc. and removal of form for : Foundation, footing, bases of columns etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors,roof,landing,balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
BRICK WORK Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : a) Cement mortar 1:6 (1 cement : 6 coarse sand)
STEEL WORK Structural steel work riveted,bolted or welded in built up sections,trusses and framed work including cutting,hoisting,fixing in position and applying a priming coat of approved steel primer all complete.
FINISHING 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Painting with black anti corrosive bitumastic paint of approved brand and manufature ti give an even shade Two or more coats on new work
Operational Gate STEEL WORK Structural steel work riveted,bolted or welded in built up sections,trusses and framed work including cutting,hoisting,fixing in position and applying a priming coat of approved steel primer all complete.
FINISHING Painting with black anti corrosive bitumastic paint of approved brand and manufature ti give an even shade Two or more coats on new work
Painting with synthetic enamel paint of approved brand and manufacture of required colour to gice an even shade. Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufature
Watch Tower EARTH WORK Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m. All kinds of soil.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
CONCRETE WORK Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. 1:3:6 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
R.C.C. WORK Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately) All works upto Plinth level concrete of M25 grade with minimum cement content of 330 kg/cum
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately) All works above plinth level upto floor V level concrete of M25 grade with minimum cement content of 330 kg/cum
Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars
Centering and shuttering including strutting, propping etc. and removal of form for : Foundation, footing, bases of columns etc. for mass concrete
Centering and shuttering including strutting, propping etc and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
BRICK WORK Providing & laying Gypsum panel partition 100mm thick with water proof gypsum panels of size 666x500x100mm made of calcite phosphor gypsum fixed with tongue and groove edges and jointed with bonding plaster as per manufacturer" specification in superstructure above plinth level upto floor V panel.Gypsum blocks will have a minimum compressive strength of 9.3 Kg/cm2 Gypsum panel partitions
CLADDING WORK Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab upto 0.50 sqm
WOOD WORK Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete 300x10 mm
Providing and fixing aluminium handle ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 125 mm
Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete: a) Twin rubber stopper
Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in-charge
STEEL WORK Structural steel work riveted,bolted or welded in built up sections,trusses and framed work including cutting,hoisting,fixing in position and applying a priming coat of approved steel primer all complete
FLOORING 25mm wooden planking,tongued and grooved in flooring,including fixing with iron screws complete with second class teak wood
kota stone slabs 20mm thick in risers of steps,skirting,dado and pillars laid on 12mm (average ) thick cement mortor 1:3 ( 1 cement 3 coarse sand ) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs,including rubbing and polishing complete. for skirting
ROOFING Providing & fixing precoated galvanised iron profile sheets ( size,shape and pitch of corrugation as approved by Engineer in charge ) of total coated thickness 0.50mm ( base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS 277,in 240 mpa steel grade.5-7 microns epoxy primer on both side of the sheet and polyster op coat 15-18 microns,sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12metre or as desired by Engineer in charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm ) with EPDM seal,complete upto any pitch in horizontal/vertical or curved surfaces excluding the cost of purlins,rafters and trusses and including cutting to size and shape wherever required.
FINISHING 12 mm cement plaster of mix : 1:6 (1 cement : 6 coarse sand)
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
ALUMINIUM WORKS For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board confirming to IS ; 12823 Grade I Type II,in panelling fixed in aluminium doors,windows shutters etc.complete Prelaminated particle board with decorative lamination on both sides
Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete.
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.
Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
Security Hut EARTH WORK Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m. All kinds of soil.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Excavating,spplying,stacking and filling of local earth ( including royalty)by meachanical transport upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20cm in foundation trenches,plinth,sides of foundation etc.complete for all lift.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for post construction anti termite treatment Treatment of soil under floors and apron using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the Plinth level : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
CONCRETE WORK Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. 1:3:6 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification work in doses by weight of cement as per manufacturer's specification
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
R.C.C. WORK Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately) All works upto Plinth level concrete of M25 grade with minimum cement content of 330 kg/cum
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately) All works above plinth level upto floor V level concrete of M25 grade with minimum cement content of 330 kg/cum
Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars
Centering and shuttering including strutting, propping etc. and removal of form for : Foundation, footing, bases of columns etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors,roof,landing,balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for : Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like
Centering and shuttering including strutting, propping etc. and removal of form for : Weather shade, Chajjas, corbels etc., including edges
BRICK WORK Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : a) Cement mortar 1:6 (1 cement : 6 coarse sand)
CLADDING WORK Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab upto 0.50 sqm
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab over 0.50 sum.
Providing & fixing stone slab with table rubbed,edges rounded and polished of size 75x50 cm deep and 1.8cm thick fixed on parapet top by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 6mm nominal size ) as per direction of Engineer in charge and finished smooth. Granite stone of approved make.
FLOORING Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc. complete. for flooring Size of Tile 600x600 mm for flooring
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacture in all colours and shede in skirting,riser of steps,laid with cement based high polymer modified quick set tile adhesive ( water based )confirming to IS 15477 in average 6mm thickness including grouting of joints ( payment for grouting of joints to be made separately ). Size of Tile 600x600 mm
Kota stone slab flooring over 20mm ( average ) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab cement mortor 1:4 ( 1 cement : 4 coarse sand ) 25mm thick
FINISHING 12 mm cement plaster of mix : 1:6 (1 cement : 6 coarse sand)
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Painting with aluminium paint of approved brand and manufacture to give an even surface. Two or more coats on new work
ALUMINIUM WORKS For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete.
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With brass cover plate minimum 1.25 mm thickness
Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge Anodized (AC 15 ) aluminium tubular handle bar
Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
WATERPROOFING Grading roof for water proofing treatment with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size )
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87- 0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/ 250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3mm thick
Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to thewoven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation.
Chequerred precast cement concrete tiles 22 mm thick in foot path on 20 mm thick bed of cement mortar (1:4). Dark shade using ordinary cement
ROAD WORK Supplying and stacking of hard stone ( for stone ptching ) 22.5cm thick at site
Dry stone pitching 22.5cm thick laid in courses and required proile with hammer dressed stone having no side less than 15 cm with minimum depth of 20cm including preparing the bedding surface etc.all complete.
INTERNAL ELECTRICAL WORKS (EXTERNAL) WIRING FOR CCTV SYSTEM Supply and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface / recess steel / PVC conduit as required 1 run of cable
Supplying and Fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
SUB HEAD X - CCTV SYSTEM Supply and Installation testing and commissioning 4MP Bullet camera, ONVIF profilr SNG, UL, CE, FCC certified, 1/2 8" Progressive Scan CMOS, 2.8mm to 12mm motorized varifocal lens ,min illuminated : 0.05 Lux @ ( F1 2, ACG ON), 0 Lux with IR, Shutter Speed :1/5s -1/100,000s 90dB WDR , SD card support ,Alaram trigger - 1 input /1 output , Video Compression : H 265,H 264 ,frame rate :30fps @ 3MP ,Edge analytic line crossing , perimeter intrusion , Face delection , cross counting , stationary object , In built IR LED , IR Distance upto 60 meters , IP 66, POE.
Supply, installation, testing and commissioning of 1 Professional DVR with 16 Video Input,H 264 Compression -D 1 Display Resolution with 2.5TB HDD, Expandable up to 8TB , Total recording Irames @ 400 fps, Recording based on Continous, Motion, Scheduled or alarm, Remote backup through TCP/P,HTTP Networkable, backup by USB/DVDWR, Client software include, POS Transcation data recording with image, Supplied with Licensed OS, keyboard & mouse, complete as required and as per specification. The DVR shall be integrated with Access control system ( Along with 2 nos. 4 TB)
40" Full LED Professional Display for Monitoring with mounting accessories
Supply, installation, testing & commissioning of 5 metre hot dipped galvanised octagonal pole with 130 mm bottom A/F and 70 mm top A/F made upto 3 mm thick. HT sheet along with base plate of size 200x200x12 mm thick (without bracket) and including foundation along the provision of cable entry.
SUB HEAD XII - EXTERNAL LIGHTING High Mast Supply, installation, testing & commissioning of 4 metre hot dipped galvanised octagonal pole with 130 mm bottom A/F and 70 mm top A/F made upto 3 mm thick. HT sheet along with base plate of size 200x200x12 mm thick (without bracket) and including foundation along the provision of cable entry.
Supply, installation, testing & commissioning of 4 nos of M16x450 long 'J' type EN8 grade foundation bolts along with templates
Supply, installation, testing & commissioning of 16 mtr hot dip galvanised octagonal pole with 130 mm bottom A/F and 70 mm top A/F made upto 3 mm thick. HT sheet along with base plate of size 200x200x12 mm thick (without bracket)
Supply, installation, testing & commissioning of 4 nos of M20x600 long 'J' type EN8 grade foundation bolts along with templates
Supply, installation, testing & commissioning of 1 mtr long hot dip galvanised Single arm Special bracket (Model : Type 5) cross arm made up of GI pipe suitable to mount on pole having to 70mm A/F. Model : Type 5
Supply, installation, testing & commissioning of Street Light of 30W Light Fixture
11 KV 200 KVA TRANSFORMER DP STRUCTURE WORKS Supplying & erecting end pole D. P. Structure for 11/0.415 KV, 100 KVA Transformer with R.S.J. Pole 2 Nos. of size 100 x 116 mm x 11 Mtr. Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with L.T. Cable, 4 Pole MCCB 300 Amps as incomer & 6 Nos.100 Amps MCCB for outgoing circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps, D.O. fuse Set & L.A. Set. 2 Nos. Top channel of size 100 mm x 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 x mm for erecting Transformer. Channel of size 75 x40 mm for erecting D.O. Fuse Set, L.A., A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box , Transformer Belt etc.as per drawing (min. 124 Kg. iron work ) with necessary clamps, Nut-bolts. vee cross arm, top clip, insulators etc. complete with caution board & barbed wire. Pipe Type & Plate Type Earthing with suitable size Earthing Strips. D.P. Structure shall be erected in c.c. foundation complete
Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 200 kVA, oil immersed and naturally cooled outdoor type, copper wound transformer, delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 40oC by thermometer in oil and 45 Degree C by the resistance in winding at full load rating, with HV tapping (with off load tap changer) off load +5 to -10 in steps of 2.5%, with standard accessories complete with test certificate with losses below ........ Watts at 50% load, ...... Watts at 100% load as per IS:1180 - 2014 energy efficiency level II, with necessary permissions of Electrical Inspector.
Main Panel : ( OUT DOOR Type ) Outgoing Side: Supplying & erecting & marking miniature circuit breaker (As per IS:8828 of 1996) Four pole 40 Amp 10 KA with required wiring connections & lugs ferruling at both the ends of wires etc. in provided panel board complete with terminal block of suitable ampere rating and Din rail channel. Note : - Panel should be manufactured as per approved GA Drawings. Dust proof rubber gasketing. MCCB & MCB compartments should be indipendently easily openable / lockable through SS door lock. Three Panel key provided with each panel. Panel should be mounted on M.S. stand of angle frame of 600 mm height & duly grouted with anchor fastner.
Supply & Erection of 4P MCCB of ratings 200 A with short circuit ratings of 25KA capacity complete erected in provided enclosure & connected with extended busbars, spreader links & phase barriers on incoming & outgoing side with extended rortary handle other mountings accessories duly erected in an approved manners. It includes the rate door lock, hinges, & rubber gasketing necessary hardwares & control wiring complete. - 1 Nos
Supplying & erecting L.T. XLPE armoured cable 1100V. grade with I.S.I. mark stranded / Solid Aluminium with G.I.saddles screwed, with continuous 12 SWG G.I. earth wire complete erected on wall with M.S.clamps / in provided trench / in provided pipe in an approved manner A) ---do --- 31/2C X 70 Sq.mm Aluminium
Supplying & erecting L.T. XLPE armoured cable 1100V. grade with I.S.I. mark stranded / Solid Aluminium with G.I.saddles screwed, with continuous 12 SWG G.I. earth wire complete erected on wall with M.S.clamps / in provided trench / in provided pipe in an approved manner. B) ---do --- 31/2C X 95 Sq.mm Aluminium
Making trench of suitable width and depth in hard murum / tar road for laying provided LT cable of 16 sq. mm & above and covered with half round hume pipe complete as per specification no. CW-EXN-CTR
Erecting of LT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 , 3 X 240V,50 Hz with optical & RS 232 port, backlit LCD, measures & displays trivector energy, load survey, TOD, tamper detection & logging, power ON /OFF events, instantaneous parameters of rating 1/5 A with display in absence of power complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box and connected to CTs.
Liasioning Charges for obtaining approval of the substation drawing & other offical documnetation, No obection certificate from Electrical Inspector & other PWD Officer .
Liasioning Charges for completing all the formalities for sanctioning the load from M.S.E.D.C.L, Testing of metering cubical & other inspection on site to complete charging of the installation
INTERNAL ELECTRICAL WORKS (PTB) SUB HEADING I - INTERNAL WIRING Wiring for Light Point / Fan Point / Exhaust Fan Point / Call Bell Point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch, modular plate, suitable GI Box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2 x 1.5 sq.mm + 1 x 1 sq.mm earth wire
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2 x 4 sq.mm + 1 x 4 sq.mm earth wire
Supplying and Fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and Fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm
Supply and Fixing two module step type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc.
Supplying and fixing suitable size GI Box with modular plate & cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI Box with modular plate & cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 modular socket outlet and 5/6 A modular switch, connections etc. as required
WIRING FOR CCTV SYSTEM Supply and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface / recess steel / PVC conduit as required 1 run of cable
Supplying and Fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and Fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm
SUB HEADING II - TELEPHONE AND LAN SYSTEM Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet
Supplying and fixing following size / modules, GI box along with modular base and cover plate for modular switches in recess etc. as required. 1 or 2 module (75mm x 75mm)
Supplying and fixing following size / modules, GI box along with modular base and cover plate for modular switches in recess etc. as required. 3 module (100mm x 75mm)
Supplying and fixing following size / modules, GI box along with modular base and cover plate for modular switches in recess etc. as required. 4 module (125mm x 75mm)
Supplying and fixing following size / modules, GI box along with modular base and cover plate for modular switches in recess etc. as required. 6 module (200mm x 75mm)
Supplying and fixing following size / modules, GI box along with modular base and cover plate for modular switches in recess etc. as required. 8 module (125mm x 125mm)
Supplying and fixing following Modular base & Cover Plate on existing modular metal boxes etc.as required. 1 or 2 module
Supplying and fixing following Modular base & Cover Plate on existing modular metal boxes etc.as required 3 module
Supplying and fixing following Modular base & Cover Plate on existing modular metal boxes etc.as required 4 module
Supplying and fixing following Modular base & Cover Plate on existing modular metal boxes etc.as required 6 module
Supplying and fixing following Modular base & Cover Plate on existing modular metal boxes etc.as required 8 module
SUB HEADING III - DISTRIBUTION BOARD Supply and Fixing following way horizontal type three pole and neutral, sheet steel, MCB distribution board, 415V, on surface/recess, complete with tinned copper bus bars ,neutral bus bar,earth bar, din bar,interconnection powder coated,as required(with out MCB/RCCB/MCCB) 6WAY (4+18), Double Door
Supplying and Fixing 5A to 32A rating, 240/415V, 10kA, 'C' curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc.as required. Single Pole
Supplying and Fixing rating, double pole, 240V. Isolator in the existing MCB DB complete with connections, testing and commissioning etc.as required. 40A
Supplying and Fixing rating, Four pole, 415V. Isolator in the existing MCB DB complete with connections, testing and commissioning etc.as required. 40A
Supplying and Fixing rating, Four pole, 415V. Isolator in the existing MCB DB complete with connections, testing and commissioning etc.as required. 63 A
Supplying and Fixing rating, Four pole, 415V. Isolator in the existing MCB DB complete with connections, testing and commissioning etc.as required. 100 A
SUB HEADING IV - EARTHING Earthing with GI earth pipe 4.5 metre long, 40mm diameter including accessories, and providing masonry enclosure with cover plate having locking arrangemet and watering pipe etc. with charcoal, coke and salt as required.
Providing and laying earth connection with earth electrode with 6 SWG dia GI wire in 15mm dia GI pipe from earth electrode including connection with GI thimble excavation and re-filling as required.
Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing along with existing surface / recess conduit / submai wiring / cable as required.
SUB HEADING V - L.V. CABLES Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. up to 35 sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC / HUME / METAL Pipe as required. up to 35 sq.mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required up to 35 sq.mm
SUB HEAD VI - TELEPHONE AND LAN SYSTEM Supply, laying connecting and testing of multi-core telephone armoured /unarmoured cable of conductor size 0.6mm dia annealed copper conductor PVC insulated PVC sheathed jelly fitted (as per DOT specification )cable as required. 20 pair telephone armoured cable
Supply and fixing connecting and testing of under noted size of solderless telephone tag block krone make in surface in wall required size of M.S. box with hinged lockable cover duly slove enamel painted. 20 pair tag block
Supplying and fixing M.S. box with modular type (RJ-45) outlet for LAN complete as required.
Supply, installation, testing and commissioning of pure server based IP-PBX with 24 analog extension with CLI facilities System complete as required.
Supply, installation testing and commissioning of Brodband Lan connection complete as requird with 10MBPS Speed
Supply installation testing and commissioning of 24 port L2 Managed switch having port density 24 Nos of 10M/100M/1G RJ45 Port POE /POE + ports, 2 Nos of GbE RJ45/SFP Combo port, 1X console, available POE power 370W, 52 Gbps switching bandwidth, 8K MAC address support, support L2 feature STP, RSTP, MSTP, Support 802, 1Q VLAN, port based VLAN, 4K VLAN entries, MAC based VLAN, IP subnet based VLAN, Support IEEE 802.3ad LACP, L3 features - static routing, DHCP feature, Device Management system - topology view, floor view, map view, dashboard, traffic monitoring, cable diagnostics, CE, FCC certified. (Approved Make - Cisco/Juniper/Axis/Impulse/Mobotix/Avigilon)
SUB HEAD VII - DISTRIBUTION PANEL BUSBAR Electrolytic high conductivity aluminium three phase and neutral busbar rated at 400 amps, 15KA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. Current density of Bus Bar to be 1.2 sq.mm / amp. OUTGOINGS 5 nos 63Amp 10kA 440 volt, FP MCB 1 nos 100Amp 16kA 440 volt, FP MCCB along with 100 FP Contractor 2 nos 160Amp 16kA 440 volt, FP MCCB along with 100 FP Contractor
LT PANEL 63 Amp FP MCCB of 16 KA breaking capacity & Trip setting as required.( MAIN LIGHT PANEL)( MAIN RAWPOER PANEL) ( MAIN EMERGENCY PANEL)
140 Amp FP MCCB of 16 KA breaking capacity & Trip setting as required.( MAIN AC PANEL)(PUMP PANEL)
SUB HEAD VIII - FANS, LIGHT FIXTURES Supplying, Fixing, testing and commissioning of recessed mounted luminaire of 34W LED 600x600 of 5700K suitable for operation on 230 volt 50 Hz, Single phase AC supply with all accessories complete for ceiling, Havells Cat No: LHEWEBP6IN1W034 or equivalent make.
Supplying, Fixing, testing and commissioning of recessed mounted circular 12W LED downlighter with CRCA / pressure diecast aluminium heat sink & white finish polycarbonate diffuser, complete with electronic LED driver, efficacy better than 90 lumens / watt with CRI > 80 including making suitable arrangement for fixing on false ceiling & connection complete as required.
Supplying, Fixing, testing and commissioning of Flood Light 70W LED light suitable for operation on 230 volt 50 Hz, Single Phase AC supply with all accessories complete as required
Supplying, Fixing, testing and commissioning of 8W LED Mirror light complete as required
Supply and Fixing of 6x6 Exhaust Fan for opertaion of 230V olt 50Hz ,Sinlge phase AC Supply with all accessories complete as required.
Supplying, Erection, Connecting, testing and commissioning of 1200mm sweep ceiling fan with GI Fa box, blades, down rod, shackle insulator, canopy etc. including providing of electronic step regulator with faceplate matching the existing modular swithces as required (Similar to Havells-Pacer)
UPS Supply, unloading, installation at Ground Floor, testing & commissioning of micro processor / DSP controlled 5 KVA UPS, IGBT based rectifier to achieve THDI < 5% and input power factor of greater than 0.95 at 50% loading. True Online Double Conversion (VFI as per IEC 62040-3). UPS using PWM IGBT technology, 1 phase input and 1 phase 230 V output UPS system, and each comprising of the following: 125% rated Rectifier cum charger unit + 100% rated invertor, Integrated in UPS module 100% rated External Galvanic isolation transformers of K-13 Delta/Zigzag type for isolation of input neytral with output neutral, to be installed after UPS as shown in drawing enclosed 100% rated inbuilt static switch at the invertor output + 2 Nos 100% rated inbuilt static switches at the static bypass line 100% rated inbuilt maintenance bypass 100% rated moulded case battery circuit breaker having thermal, magnetic and Automatic U/V trip mechanics Web-enabled Monitoring and Management through SNMP protocols for multi-OS environments.
Supply, unloading, installation at Basement, testing & commissioning of Lead Acid Sealed maintenance free batteries for 5KVA UPS system, for providing 15 minutes backup to 5KVA UPS for full load. The bank of batteries shall comprise required Nos of batteries complete as required. Battery sizing calculation are to be submitted for approval.
Supply, unloading, installation at Basement, testing & commissioning of matching cabinet/ open racks to house SMF batteries for 5KVA UPS system along with interconnecting links, MCB, etc. complete as required & as per specifications
Supplying, Laying, testing and commissioning of flexible single core copper cable of finolex / Skyline / Havells / Nyvin make for interconnections between UPS to UPS, UPS to batteries, UPS to Isolation Transformer, complete as required for 5KVA UPS, including providing battery circuit breakers as required.
Supply, installation, testing & commissioning of UPS monitoring software suitable for RJ-45 communication and capable of giving pop up messages for all alarms received from UPS. It shall be capable of following: giving notifications like e-mail, paging notification, broadcast notification, battery replacement notification, run event-based scripts Event logging, data logging and action logging (with date, time, description of fault and event) run the battery diagnostic test Automated unattended shutdown of computers Local notification through audible alarm Software should support Microsoft Windows NT / 2000 / Server, 2003/XP, AIX, HP-UX, Sun Solaris, Linux, Novel Netware UPS described as above complete in all respects
Providing and fixing of self illuminated / auto glow "EXIT" signs printed on photoluminescent sheet containing self illuminated base chemical, of appropriate size not less than 400 x 150 mm, suspended from ceiling or fixed to the walls with accessories as required and as directed at site.
SUB HEAD IX - L.V. CABLES Supply testing of under noted sizes of Aluminium conductor XLPE insulated PVC sheathed & sleeved armoure and overall PVC sleeved 1.1KV grade power distribution cables conforming to relevant IS code. 4 x 10 sq.mm Al Armoured
SUB HEAD IX - L.V. CABLES Supply testing of under noted sizes of Aluminium conductor XLPE insulated PVC sheathed & sleeved armoure and overall PVC sleeved 1.1KV grade power distribution cables conforming to relevant IS code. 4 x 16 sq.mm Al Armoured
SUB HEAD IX - L.V. CABLES Supply testing of under noted sizes of Aluminium conductor XLPE insulated PVC sheathed & sleeved armoure and overall PVC sleeved 1.1KV grade power distribution cables conforming to relevant IS code. 4 x 20 sq.mm Al Armoured
SUB HEAD IX - L.V. CABLES Supply testing of under noted sizes of Aluminium conductor XLPE insulated PVC sheathed & sleeved armoure and overall PVC sleeved 1.1KV grade power distribution cables conforming to relevant IS code. 4 x 25 sq.mm Al Armoured
SUB HEAD IX - L.V. CABLES Supply testing of under noted sizes of Aluminium conductor XLPE insulated PVC sheathed & sleeved armoure and overall PVC sleeved 1.1KV grade power distribution cables conforming to relevant IS code. 3.5 x 50 sq. mm Al Armoured
SUB HEAD IX - L.V. CABLES Supply testing of under noted sizes of Aluminium conductor XLPE insulated PVC sheathed & sleeved armoure and overall PVC sleeved 1.1KV grade power distribution cables conforming to relevant IS code. 3.5 x 70 sq.mm Al Armoured
SUB HEAD IX - L.V. CABLES Supply testing of under noted sizes of Aluminium conductor XLPE insulated PVC sheathed & sleeved armoure and overall PVC sleeved 1.1KV grade power distribution cables conforming to relevant IS code. 3.5 x 95 sq.mm Al Armoured
SUB HEAD X - CCTV SYSTEM Supply, installation, testing & commissioning of colour dome camera with 2MP along with suitable lens, stainless steel brush finish plate etc. complete as required & as per specifications (For Basement Lift Lobby and Entrance Hall & Terrace Lobby)
Supply and Installation testing and commissioning 4MP Bullet camera, ONVIF profilr SNG, UL, CE, FCC certified, 1/2 8" Progressive Scan CMOS, 2.8mm to 12mm motorized varifocal lens ,min illuminated : 0.05 Lux @ ( F1 2, ACG ON), 0 Lux with IR, Shutter Speed :1/5s -1/100,000s 90dB WDR , SD card support ,Alaram trigger - 1 input /1 output , Video Compression : H 265,H 264 ,frame rate :30fps @ 3MP ,Edge analytic line crossing , perimeter intrusion , Face delection , cross counting , stationary object , In built IR LED , IR Distance upto 60 meters , IP 66, POE.
Supply, installation, testing and commissioning of 1 Professional DVR with 16 Video Input,H 264 Compression -D 1 Display Resolution with 2.5TB HDD, Expandable up to 8TB , Total recording Irames @ 400 fps, Recording based on Continous, Motion, Scheduled or alarm, Remote backup through TCP/P,HTTP Networkable, backup by USB/DVDWR, Client software include, POS Transcation data recording with image, Supplied with Licensed OS, keyboard & mouse, complete as required and as per specification. The DVR shall be integrated with Access control system ( Along with 2 nos. 4 TB)
40" Full LED Professional Display for Monitoring with mounting accessories.
Supply, installation, testing & commissioning of 5 metre hot dipped galvanised octagonal pole with 130 mm bottom A/F and 70 mm top A/F made upto 3 mm thick. HT sheet along with base plate of size 200x200x12 mm thick (without bracket) and including foundation along the provision of cable entry.
SUB-HEAD XI DG SETS Supply at site, installation, testing & commissioning of 3- phase,415volt, 1500RPM, 50Hz, Diesel Generator set of 80KVA at 0.8 lagging diesel engine alternator set mounted on common base frame in outdoor type acoustic enclousre with built in fuel tank of required capacity along with additional day tank capacity of 990 litres including fuel piping, level indicator, and valves as required, with AMF Panel, battery, battery charger, return fuel cooler, ani vibration mounting pads including residential silencer, engine alternator,pcc based auto start & synchronization set, safeless with accessories and control cabling for AMF panel up to 50mtr, length as per specfication complete as required. Diesel engine shall conform to IS:10000 and Alternator shall be self excited complete with AVR to IS:4722
Supplying and fixing of undermoted 'B' class MS pipe for DG exhaust complete with bends, elbow flanges etc.as required. 125 mm dia pipe
Supply and fixing of 50mm thick compressed mineral wool insulation ( Rock wool) for D.G. exhaust pipe with 22 gauge aluminium sheet clading etc. as required for the under mentioned dia pipe. 125 mm dia pipe
Fabrication of supports for exhaust pipe, fuel pipe or for any other purpose out of M.S. structural steel including supplying and applying of enamel paint of approved shade after one coat of steel printer of reputed company.
INTERNAL ELECTRICAL WORKS (FSB) SUB HEADING I - INTERNAL WIRING Wiring for Light Point / Fan Point / Exhaust Fan Point / Call Bell Point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch, modular plate, suitable GI Box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2 x 1.5 sq.mm + 1 x 1 sq.mm earth wire
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire
Supplying and Fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and Fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm
Supply and Fixing two module step type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc.
Supplying and fixing suitable size GI Box with modular plate & cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI Box with modular plate & cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 modular socket outlet and 5/6 A modular switch, connections etc. as required
SUB HEADING II - TELEPHONE AND LAN SYSTEM Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet
Supplying and fixing following size / modules, GI box along with modular base and cover plate for modular switches in recess etc. as required. 1 or 2 module (75mm x 75mm)
Supplying and fixing following size / modules, GI box along with modular base and cover plate for modular switches in recess etc. as required. 3 module (100mm x 75mm)
Supplying and fixing following size / modules, GI box along with modular base and cover plate for modular switches in recess etc. as required. 4 module (125mm x 75mm)
Supplying and fixing following size / modules, GI box along with modular base and cover plate for modular switches in recess etc. as required. 6 module (200mm x 75mm)
Supplying and fixing following size / modules, GI box along with modular base and cover plate for modular switches in recess etc. as required. 8 module (125mm x 125mm)
Supplying and fixing following Modular base & Cover Plate on existing modular metal boxes etc.as required. 1 or 2 module
Supplying and fixing following Modular base & Cover Plate on existing modular metal boxes etc.as required 3 module
Supplying and fixing following Modular base & Cover Plate on existing modular metal boxes etc.as required 4 module
Supplying and fixing following Modular base & Cover Plate on existing modular metal boxes etc.as required 6 module
Supplying and fixing following Modular base & Cover Plate on existing modular metal boxes etc.as required 8 module
SUB HEADING III - DISTRIBUTION BOARD Supply and Fixing following way horizontal type three pole and neutral, sheet steel, MCB distribution board, 415V, on surface/recess, complete with tinned copper bus bars ,neutral bus bar,earth bar, din bar,interconnection powder coated,as required(with out MCB/RCCB/MCCB) 6WAY (4+18), Double Door
Supplying and Fixing 5A to 32A rating, 240/415V, 10kA, 'C' curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc.as required. Single Pole
Supplying and Fixing rating, Four pole, 415V. Isolator in the existing MCB DB complete with connections, testing and commissioning etc.as required. 40A
Supplying and Fixing rating, Four pole, 415V. Isolator in the existing MCB DB complete with connections, testing and commissioning etc.as required. 63 A
SUB HEADING V - L.V. CABLES Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. up to 35 sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC / HUME / METAL Pipe as required. up to 35 sq.mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required up to 35 sq.mm
SUB HEAD VI - TELEPHONE AND LAN SYSTEM Supply, laying connecting and testing of multi-core telephone armoured /unarmoured cable of conductor size 0.6mm dia annealed copper conductor PVC insulated PVC sheathed jelly fitted (as per DOT specification )cable as required. 20 pair telephone armoured cable
Supply and fixing connecting and testing of under noted size of solderless telephone tag block krone make in surface in wall required size of M.S. box with hinged lockable cover duly slove enamel painted. 20 pair tag block
Supplying and fixing M.S. box with modular type (RJ-45) outlet for LAN complete as required.
Supply, installation, testing and commissioning of pure server based IP-PBX with 24 analog extension with CLI facilities System complete as required.
Supply, installation testing and commissioning of Brodband Lan connection complete as requird with 10MBPS Speed
Supply installation testing and commissioning of 24 port L2 Managed switch having port density 24 Nos of 10M/100M/1G RJ45 Port POE /POE + ports, 2 Nos of GbE RJ45/SFP Combo port, 1X console, available POE power 370W, 52 Gbps switching bandwidth, 8K MAC address support, support L2 feature STP, RSTP, MSTP, Support 802, 1Q VLAN, port based VLAN, 4K VLAN entries, MAC based VLAN, IP subnet based VLAN, Support IEEE 802.3ad LACP, L3 features - static routing, DHCP feature, Device Management system - topology view, floor view, map view, dashboard, traffic monitoring, cable diagnostics, CE, FCC certified. (Approved Make - Cisco/Juniper/Axis/Impulse/Mobotix/Avigilon)
SUB HEAD VIII - FANS, LIGHT FIXTURES Supplying, Fixing, testing and commissioning of recessed mounted circular 12W LED downlighter with CRCA / pressure diecast aluminium heat sink & white finish polycarbonate diffuser, complete with electronic LED driver, efficacy better than 90 lumens / watt with CRI > 80 including making suitable arrangement for fixing on false ceiling & connection complete as required.
Supplying, Fixing, testing and commissioning of 8W LED Mirror light complete as required
Supplying, Erection, Connecting, testing and commissioning of 1200mm sweep ceiling fan with GI Fa box, blades, down rod, shackle insulator, canopy etc. including providing of electronic step regulator with faceplate matching the existing modular swithces as required (Similar to Havells-Pacer)
Supply and Fixing of 6x6 Exhaust Fan for opertaion of 230V olt 50Hz ,Sinlge phase AC Supply with all accessories complete as required.
Supply, unloading, installation at Ground Floor, testing & commissioning of micro processor / DSP controlled 5 KVA UPS, IGBT based rectifier to achieve THDI < 5% and input power factor of greater than 0.95 at 50% loading. True Online Double Conversion (VFI as per IEC 62040-3). UPS using PWM IGBT technology, 1 phase input and 1 phase 230 V output UPS system, and each comprising of the following: 125% rated Rectifier cum charger unit + 100% rated invertor, Integrated in UPS module 100% rated External Galvanic isolation transformers of K-13 Delta/Zigzag type for isolation of input neytral with output neutral, to be installed after UPS as shown in drawing enclosed 100% rated inbuilt static switch at the invertor output + 2 Nos 100% rated inbuilt static switches at the static bypass line 100% rated inbuilt maintenance bypass 100% rated moulded case battery circuit breaker having thermal, magnetic and Automatic U/V trip mechanics Web-enabled Monitoring and Management through SNMP protocols for multi-OS environments.
UPS Supply, unloading, installation at Basement, testing & commissioning of Lead Acid Sealed maintenance free batteries for 5KVA UPS system, for providing 15 minutes backup to 5KVA UPS for full load. The bank of batteries shall comprise required Nos of batteries complete as required. Battery sizing calculation are to be submitted for approval.
Supply, unloading, installation at Basement, testing & commissioning of matching cabinet/ open racks to house SMF batteries for 5KVA UPS system along with interconnecting links, MCB, etc. complete as required & as per specifications
Supplying, Laying, testing and commissioning of flexible single core copper cable of finolex / Skyline / Havells / Nyvin make for interconnections between UPS to UPS, UPS to batteries, UPS to Isolation Transformer, complete as required for 5KVA UPS, including providing battery circuit breakers as required.
Supply, installation, testing & commissioning of UPS monitoring software suitable for RJ-45 communication and capable of giving pop up messages for all alarms received from UPS. It shall be capable of following: giving notifications like e-mail, paging notification, broadcast notification, battery replacement notification, run event-base scripts Event logging, data logging and action logging (with date, time, description of fault and event) run the battery diagnostic test Automated unattended shutdown of computers Local notification through audible alarm Software should support Microsoft Windows NT / 2000 / Server, 2003/XP, AIX, HP-UX, Sun Solaris, Linux, Novel Netware UPS described as above complete in all respects
Providing and fixing of self illuminated / auto glow "EXIT" signs printed on photoluminescent sheet containing self illuminated base chemical, of appropriate size not less than 400 x 150 mm, suspended from ceiling or fixed to the walls with accessories as required and as directed at site.
SUB HEAD IX - L.V. CABLES Supply testing of under noted sizes of Aluminium conductor XLPE insulated PVC sheathed & sleeved armoure and overall PVC sleeved 1.1KV grade power distribution cables conforming to relevant IS code. 4 x 10 sq.mm Al Armoured
SUB HEAD IX - L.V. CABLES Supply testing of under noted sizes of Aluminium conductor XLPE insulated PVC sheathed & sleeved armoure and overall PVC sleeved 1.1KV grade power distribution cables conforming to relevant IS code. 4 x 16 sq.mm Al Armoured
SUB HEAD IX - L.V. CABLES Supply testing of under noted sizes of Aluminium conductor XLPE insulated PVC sheathed & sleeved armoure and overall PVC sleeved 1.1KV grade power distribution cables conforming to relevant IS code. 4 x 20 sq.mm Al Armoured
SUB HEAD IX - L.V. CABLES Supply testing of under noted sizes of Aluminium conductor XLPE insulated PVC sheathed & sleeved armoure and overall PVC sleeved 1.1KV grade power distribution cables conforming to relevant IS code. 4 x 25 sq.mm Al Armoured
SUB HEAD X - CCTV SYSTEM Supply, installation, testing & commissioning of colour dome camera with 2MP along with suitable lens, stainless steel brush finish plate etc. complete as required & as per specifications (For Basement Lift Lobby and Entrance Hall & Terrace Lobby)
Supply, installation, testing and commissioning of 1 Professional DVR with 16 Video Input,H 264 Compression -D 1 Display Resolution with 2.5TB HDD, Expandable up to 8TB , Total recording Irames @ 400 fps, Recording based on Continous, Motion, Scheduled or alarm, Remote backup through TCP/P,HTTP Networkable, backup by USB/DVDWR, Client software include, POS Transcation data recording with image, Supplied with Licensed OS, keyboard & mouse, complete as required and as per specification. The DVR shall be integrated with Access control system ( Along with 2 nos. 4 TB)
40" Full LED Professional Display for Monitoring with mounting accessories.
INTERNAL ELECTRICAL WORKS (UB ) SUB HEADING I - INTERNAL WIRING Wiring for Light Point / Fan Point / Exhaust Fan Point / Call Bell Point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch, modular plate, suitable GI Box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2 x 1.5 sq.mm + 1 x 1 sq.mm earth wire
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire
Supplying and Fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and Fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm
Supply and Fixing two module step type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc.
Supplying and fixing suitable size GI Box with modular plate & cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI Box with modular plate & cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 modular socket outlet and 5/6 A modular switch, connections etc. as required
SUB HEADING II - TELEPHONE AND LAN SYSTEM Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet
Supplying and fixing following size / modules, GI box along with modular base and cover plate for modular switches in recess etc. as required. 1 or 2 module (75mm x 75mm)
Supplying and fixing following size / modules, GI box along with modular base and cover plate for modular switches in recess etc. as required. 3 module (100mm x 75mm)
Supplying and fixing following size / modules, GI box along with modular base and cover plate for modular switches in recess etc. as required. 4 module (125mm x 75mm)
Supplying and fixing following size / modules, GI box along with modular base and cover plate for modular switches in recess etc. as required. 6 module (200mm x 75mm)
Supplying and fixing following Modular base & Cover Plate on existing modular metal boxes etc.as required. 1 or 2 module
Supplying and fixing following Modular base & Cover Plate on existing modular metal boxes etc.as required 3 module
Supplying and fixing following Modular base & Cover Plate on existing modular metal boxes etc.as required 4 module
Supplying and fixing following Modular base & Cover Plate on existing modular metal boxes etc.as required 6 module
SUB HEADING III - DISTRIBUTION BOARD Supply and Fixing following way horizontal type three pole and neutral, sheet steel, MCB distribution board, 415V, on surface/recess, complete with tinned copper bus bars ,neutral bus bar,earth bar, din bar,interconnection powder coated,as required(with out MCB/RCCB/MCCB) 6WAY (4+18), Double Door
Supplying and Fixing 5A to 32A rating, 240/415V, 10kA, 'C' curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc.as required. Single Pole
Supplying and Fixing rating, Four pole, 415V. Isolator in the existing MCB DB complete with connections, testing and commissioning etc.as required. 40A
SUB HEADING V - L.V. CABLES Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. up to 35 sq.mm
Laying of one number PVC insulated and PVC sheathed / XLP power cable of 1.1 KV grade of following size in the existing RCC / HUME / METAL Pipe as required. up to 35 sq.mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required up to 35 sq.mm
SUB HEAD VI - TELEPHONE AND LAN SYSTEM Supply, laying connecting and testing of multi-core telephone armoured /unarmoured cable of conductor size 0.6mm dia annealed copper conductor PVC insulated PVC sheathed jelly fitted (as per DOT specification )cable as required. 20 pair telephone armoured cable
Supply and fixing connecting and testing of under noted size of solderless telephone tag block krone make in surface in wall required size of M.S. box with hinged lockable cover duly slove enamel painted. 20 pair tag block
Supplying and fixing M.S. box with modular type (RJ-45) outlet for LAN complete as required.
Supply, installation, testing and commissioning of pure server based IP-PBX with 24 analog extension with CLI facilities System complete as required.
Supply, installation testing and commissioning of Brodband Lan connection complete as requird with 10MBPS Speed
Supply installation testing and commissioning of 24 port L2 Managed switch having port density 24 Nos of 10M/100M/1G RJ45 Port POE /POE + ports, 2 Nos of GbE RJ45/SFP Combo port, 1X console, available POE power 370W, 52 Gbps switching bandwidth, 8K MAC address support, support L2 feature STP, RSTP, MSTP, Support 802, 1Q VLAN, port based VLAN, 4K VLAN entries, MAC based VLAN, IP subnet based VLAN, Support IEEE 802.3ad LACP, L3 features - static routing, DHCP feature, Device Management system - topology view, floor view, map view, dashboard, traffic monitoring, cable diagnostics, CE, FCC certified. (Approved Make - Cisco/Juniper/Axis/Impulse/Mobotix/Avigilon)
SUB HEAD VIII - FANS, LIGHT FIXTURES Supplying, Fixing, testing and commissioning of recessed mounted circular 12W LED downlighter with CRCA / pressure diecast aluminium heat sink & white finish polycarbonate diffuser, complete with electronic LED driver, efficacy betterthan 90 lumens / watt with CRI > 80 including making suitable arrangement for fixing on false ceiling & connection complete as required.
Supplying, Erection, Connecting, testing and commissioning of 200mm sweep ceiling fan with GI Fa box, blades, down rod, shackle insulator, canopy etc. including providing of electronic step regulator with faceplate matching the existing modular swithces as required (Similar to Havells-Pacer)
Supply, unloading, installation at Ground Floor, testing & commissioning of micro processor / DSP controlled 5 KVA UPS, IGBT based rectifier to achieve THDI < 5% and input power factor of greater than 0.95 at 50% loading. True Online Double Conversion (VFI as per IEC 62040-3). UPS using PWM IGBT technology, 1 phase input and 1 phase 230 V output UPS system, and each comprising of the following: 125% rated Rectifier cum charger unit + 100% rated invertor, Integrated in UPS module 100% rated External Galvanic isolation transformers of K-13 Delta/Zigzag type for isolation of input neytral with output neutral, to be installed after UPS as shown in drawing enclosed 100% rated inbuilt static switch at the invertor output + 2 Nos 100% rated inbuilt static switches at the static bypass line 100% rated inbuilt maintenance bypass 100% rated moulded case battery circuit breaker having thermal, magnetic and Automatic U/V trip mechanics Web-enabled Monitoring and Management through SNMP protocols for multi-OS environments.
UPS Supply, unloading, installation at Basement, testing & commissioning of Lead Acid Sealed maintenance free batteries for 5KVA UPS system, for providing 15 minutes backup to 5KVA UPS for full load. The bank of batteries shall comprise required Nos of batteries complete as required. Battery sizing calculation are to be submitted for approval.
Supply, unloading, installation at Basement, testing & commissioning of matching cabinet/ open racks to house SMF batteries for 5KVA UPS system along with interconnecting links, MCB, etc. complete as required & as per specifications
Supplying, Laying, testing and commissioning of flexible single core copper cable of finolex / Skyline / Havells / Nyvin make for interconnections between UPS to UPS, UPS to batteries, UPS to Isolation Transformer, complete as required for 5KVA UPS, including providing battery circuit breakers as required.
Supply, installation, testing & commissioning of UPS monitoring software suitable for RJ-45 communication and capable of giving pop up messages for all alarms received from UPS. It shall be capable of following: giving notifications like e-mail, paging notification, broadcast notification, battery replacement notification, run event-based scripts Event logging, data logging and action logging (with date, time, description of fault and event) run the battery diagnostic test Automated unattended shutdown of computers Local notification through audible alarm Software should support Microsoft Windows NT / 2000 / Server, 2003/XP, AIX, HP-UX, Sun Solaris, Linux, Novel Netware UPS described as above complete in all respects
Providing and fixing of self illuminated / auto glow "EXIT" signs printed on photoluminescent sheet containing self illuminated base chemical, of appropriate size not less than 400 x 150 mm, suspended from ceiling or fixed to the walls with accessories as required and as directed at site.
SUB HEAD IX - L.V. CABLES Supply testing of under noted sizes of Aluminium conductor XLPE insulated PVC sheathed & sleeved armoure and overall PVC sleeved 1.1KV grade power distribution cables conforming to relevant IS code. 4 x 10 sq.mm Al Armoured
INTERNAL ELECTRICAL WORKS (SECURITY HUT ) SUB HEADING I - INTERNAL WIRING Wiring for Light Point / Fan Point / Exhaust Fan Point / Call Bell Point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch, modular plate, suitable GI Box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2 x 1.5 sq.mm + 1 x 1 sq.mm earth wire
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire
Supplying and Fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and Fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm
Supply and Fixing two module step type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc.
Supplying and fixing suitable size GI Box with modular plate & cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI Box with modular plate & cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 modular socket outlet and 5/6 A modular switch, connections etc. as required
Supplying and fixing following size / modules, GI box along with modular base and cover plate for modular switches in recess etc. as required. 6 module (200mm x 75mm)
Supplying and fixing following Modular base & Cover Plate on existing modular metal boxes etc.as required. 6 module
SUB HEAD VIII - FANS, LIGHT FIXTURES Supplying, Fixing, testing and commissioning of recessed mounted circular 12W LED downlighter with CRCA / pressure diecast aluminium heat sink & white finish polycarbonate diffuser, complete with electronic LED driver, efficacy better than 90 lumens / watt with CRI > 80 including making suitable arrangement for fixing on false ceiling & connection complete as required.
Supplying, Erection, Connecting, testing and commissioning of 1200mm sweep ceiling fan with GI Fa box, blades, down rod, shackle insulator, canopy etc. including providing of electronic step regulator with faceplate matching the existing modular swithces as required (Similar to Havells-Pacer)
SUB HEAD IX - L.V. CABLES Supply testing of under noted sizes of Aluminium conductor XLPE insulated PVC sheathed & sleeved armoure and overall PVC sleeved 1.1KV grade power distribution cables conforming to relevant IS code. 4 x 10 sq.mm Al Armoured
INTERNAL ELECTRICAL WORKS (WATCH TOWER) SUB HEADING I - INTERNAL WIRING Wiring for Light Point / Fan Point / Exhaust Fan Point / Call Bell Point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch, modular plate, suitable GI Box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2 x 1.5 sq.mm + 1 x 1 sq.mm earth wire
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire
Supplying and Fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and Fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm
Supply and Fixing two module step type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc.
Supplying and fixing suitable size GI Box with modular plate & cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI Box with modular plate & cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 modular socket outlet and 5/6 A modular switch, connections etc. as required
Supplying and fixing following size / modules, GI box along with modular base and cover plate for modular switches in recess etc. as required. 6 module (200mm x 75mm)
Supplying and fixing following Modular base & Cover Plate on existing modular metal boxes etc.as required. 6 module
SUB HEAD VIII - FANS, LIGHT FIXTURES Supplying, Fixing, testing and commissioning of recessed mounted circular 12W LED downlighter with CRCA / pressure diecast aluminium heat sink & white finish polycarbonate diffuser, complete with electronic LED driver, efficacy better than 90 lumens / watt with CRI > 80 including making suitable arrangement for fixing on false ceiling & connection complete as required.
Supplying, Erection, Connecting, testing and commissioning of 1200mm sweep ceiling fan with GI Fa box, blades, down rod, shackle insulator, canopy etc. including providing of electronic step regulator with faceplate matching the existing modular swithces as required (Similar to Havells-Pacer)
SUB HEAD IX - L.V. CABLES Supply testing of under noted sizes of Aluminium conductor XLPE insulated PVC sheathed & sleeved armoure and overall PVC sleeved 1.1KV grade power distribution cables conforming to relevant IS code. 4 x 10 sq.mm Al Armoured
Passenger Termial Building Fire Adressable System Supplying, installing, testing and commissioning of intelligent analog adressable photothermal detector complete with mounting base complete as required
Supplying & laying of 2x1.5 spmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required
Supplying, installing, testing and commissioning of adressable manual call point complete as required.
Supplying, installing, testing and commissioning of adressable horn cum strobe complete as required.
Supplying & fixing of following medium sizes of PVC conduict along with accessories in surface/recess including painting iin case of surface conduict, or cutting the wall and making good the same in case of recessed conduict as required. 25mm
Supply installation testing commisioning of 6Zone, voice alarm controller with USB, MP3 Player with seamless integration facility with main fire alarm panel for voice evacuation complete as required.
Supplying, erecting, testing and commissioning sound column 6Watt complete as required.
Supplying & erecting Water Carbon Dioxide (CO2) fire extinguisher of 9Ltr capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts grouted in wall complete.
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts grouted in wall complete.
Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall.
Supplying and erecting FM 200 (Clean Agent Type) type fire extinguisher as per IS : 13849 /15683 of 4 kg capacity with necessary clamp for erection on wall.
Fire Station Building Fire Adressable System Supplying, installing, testing and commissioning of intelligent analog adressable photothermal detector complete with mounting base complete as required
Supplying & laying of 2x1.5 spmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required
Supplying, installing, testing and commissioning of adressable manual call point complete as required.
Supplying, installing, testing and commissioning of adressable horn cum strobe complete as required.
Supplying & fixing of following medium sizes of PVC conduict along with accessories in surface/recess including painting iin case of surface conduict, or cutting the wall and making good the same in case of recessed conduict as required. 25mm
Supply installation testing commisioning of 6Zone, voice alarm controller with USB, MP3 Player with seamless integration facility with main fire alarm panel for voice evacuation complete as required.
Supplying, erecting, testing and commissioning sound column 6Watt complete as required.
Supplying & erecting Water Carbon Dioxide (CO2) fire extinguisher of 9Ltr capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts grouted in wall complete.
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts grouted in wall complete.
Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall.
Supplying and erecting FM 200 (Clean Agent Type) type fire extinguisher as per IS : 13849 /15683 of 4 kg capacity with necessary clamp for erection on wall.
UTILITY BUILDING Fire Adressable System Supplying, installing, testing and commissioning of intelligent analog adressable photothermal detector complete with mounting base complete as required
Supplying & laying of 2x1.5 spmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required
Supplying, installing, testing and commissioning of adressable manual call point complete as required.
Supplying, installing, testing and commissioning of adressable horn cum strobe complete as required.
Supplying & fixing of following medium sizes of PVC conduict along with accessories in surface/recess including painting iin case of surface conduict, or cutting the wall and making good the same in case of recessed conduict as required. 25mm
Supplying, erecting, testing and commissioning sound column 6Watt complete as required.
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts grouted in wall complete.
HVAC of Passenger Terminal Building Hi wall Split AC Unit ( Heat & cool model ) Supply , Installtion , Testing & Commissoing of Hi wall Split Unit (3 or 5 star Rating , Inverter Technogoly ) With Rotary Compressor & Cordless Control of following capacity with/floor mounted OUD Stand . 1 TR Air - Heat & Cooled Split Unit
Supply , Installtion , Testing & Commissoing of Hi wall Split Unit (3 or 5 star Rating , Inverter Technogoly ) With Rotary Compressor & Cordless Control of following capacity with/floor mounted OUD Stand . 1.5 TR Air - Heat & Cooled Split Unit
Casstte AC Unit ( Heat & cool model ) Supply , Installtion , Testing & Commissoing of Hi wall Split Unit (2 to 5 star Rating , Inverter Technogoly or only Inverter ) With Rotary Compressor & Cordless Control of following capacity with/floor mounted OUD Stand . 3 TR Air Heat & Cooled 4 way Casstte AC Unit
Supply , Installtion , Testing & Commissoing of Hi wall Split Unit (2 to 5 star Rating , Inverter Technogoly or only Inverter ) With Rotary Compressor & Cordless Control of following capacity with/floor mounted OUD Stand . 4 TR Air Heat & cooled 4 way Casstte AC Unit
Refrigerant Piping for Casstte AC Supply, installation, testing & commissioning of the insulated refrigerant piping for all the units of Outdoor Unitsas per specifications with insulation of thick 19 mm Nitrile rubber through out the running length of the refrigerant piping. Nitrile Rubber of Density 50+/-20% ( Class O ) kg/m3 to interconnect Indoor & Outdoor Units for each circuit - Ref. Copper Piping for Casstte AC 4 TR
Supply, installation, testing & commissioning of the insulated refrigerant piping for all the units of Outdoor Unitsas per specifications with insulation of thick 19 mm Nitrile rubber through out the running length of the refrigerant piping. Nitrile Rubber of Density 50+/-20% ( Class O ) kg/m3 to interconnect Indoor & Outdoor Units for each circuit - Ref. Copper Piping for Casstte AC 3 TR
Refrigerant Piping for split AC Supply, installation, testing & commissioning of the insulated refrigerant piping for all the units of Outdoor Unitsas per specifications with insulation of thick 19 mm Nitrile rubber through out the running length of the refrigerant piping. Nitrile Rubber of Density 50+/-20% ( Class O ) kg/m3 to interconnect Indoor & Outdoor Units for each circuit - Ref. Copper Piping for Split AC 1 TR
Supply, installation, testing & commissioning of the insulated refrigerant piping for all the units of Outdoor Unitsas per specifications with insulation of thick 19 mm Nitrile rubber through out the running length of the refrigerant piping. Nitrile Rubber of Density 50+/-20% ( Class O ) kg/m3 to interconnect Indoor & Outdoor Units for each circuit - Ref. Copper Piping for Split AC 1.5 TR
Control Cabling for Casstte AC Supply, Installation, testing & commissioning of Cu/ Communication shielded cabling between ODU & IDU and between ODU & central controller in flexible PVC Conduit. control cabling from indoor to outdoor unit Casstte AC - 4 TR ( 3 C X 1.5 sq.mm )
Supply, Installation, testing & commissioning of Cu/ Communication shielded cabling between ODU & IDU and between ODU & central controller in flexible PVC Conduit. power supply Cable casstte AC -4 TR indoor to Out Door ( 3 C X 2.5 sq.mm)
Control Cabling for Split AC Supply, Installation, testing & commissioning of Cu/Communication shielded cabling between ODU & IDU and between ODU & central controller in flexible PVC Conduit. Control cabling from indoor to outdoor unit Split AC & Casstte AC( 4 C X 2.5 sq.mm )
Drain Piping Supply , Installtion testing & Commissoing of PVC hard drain piiping with fitting , Valves & Insulation with 10 mm for indoor Appllication Closed Cell nitrile rubber 60+/-10 kg/m3. 19 mm Dia.
Timer For CCTV Room
HVAC of Fire Building Hi wall Split AC Unit ( Heat & cool model ) Supply , Installtion , Testing & Commissoing of Hi wall Split Unit (3 or 5 star Rating , Inverter Technogoly ) With Rotary Compressor & Cordless Control of following capacity with/floor mounted OUD Stand . 1 TR Air - Heat & Cooled Split Unit
Supply , Installtion , Testing & Commissoing of Hi wall Split Unit (3 or 5 star Rating , Inverter Technogoly ) With Rotary Compressor & Cordless Control of following capacity with/floor mounted OUD Stand . 1.5 TR Air - Heat & Cooled Split Unit
Refrigerant Piping for split AC Supply, installation, testing & commissioning of the insulated refrigerant piping for all the units of Outdoor Unitsas per specifications with insulation of thick 19 mm Nitrile rubber through out the running length of the refrigerant piping. Nitrile Rubber of Density 50+/-20% ( Class O ) kg/m3 to interconnect Indoor & Outdoor Units for each circuit - Ref. Copper Piping for Split AC 1 TR
Supply, installation, testing & commissioning of the insulated refrigerant piping for all the units of Outdoor Unitsas per specifications with insulation of thick 19 mm Nitrile rubber through out the running length of the refrigerant piping. Nitrile Rubber of Density 50+/-20% ( Class O ) kg/m3 to interconnect Indoor & Outdoor Units for each circuit - Ref. Copper Piping for Split AC 1.5 TR
Control Cabling split AC Supply, Installation, testing & commissioning of Cu/ Communication shielded cabling between ODU & IDU and between ODU & central controller in flexible PVC Conduit. power supply Cable casstte AC -4 TR indoor to Out Door ( 3 C X 2.5 sq.mm)
Drain Piping Supply , Installtion testing & Commissoing of PVC hard drain piiping with fitting , Valves & Insulation with 10 mm for indoor Appllication Closed Cell nitrile rubber 60+/-10 kg/m3. 19 mm Dia.
Timer For CCTV Room
EXTERNAL WATER SUPPLY INTERNAL Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50 mm nominal dia Pipes
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore
DRAINAGE, RAIN WATER AND STROM WATER CHAMBER AND PIPE LINE Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 250 mm dia. R.C.C. pipe
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 450 mm dia. R.C.C. pipe
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With Sewer bricks conforming to IS : 4885
Extra for depth for manholes : Size 90x80 cm. With Sewer bricks conforming to IS : 4885
Extra for depth for manholes : Size 120x90 cm. With Sewer bricks conforming to IS : 4885
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) : With Sewer bricks conforming to IS : 4885
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. All types of soil 300 mm dia
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. Rocky strata including Boulders 300 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-incharge. 150 mm nominal size dia
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer- incharge.
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.
Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M- 25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge.
Septic Tank and Soak Pit EARTH WORK Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m. All kinds of soil.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil.
Extra for every additional lift of 1.5m or part thereof in excavation / banking excavated or stacked materials
CONCRETE WORK Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. 1:3:6 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
R.C.C. WORK Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately) All works upto Plinth level concrete of M25 grade with minimum cement content of 330 kg/cum
Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars
Centering and shuttering including strutting, propping etc. and removal of form for : Foundation, footing, bases of columns etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors,roof,landing,balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for : walls ( any thickness ) including attached pilasters,butteresses,plinth and string courses etc.
FINISHING 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).
Road work Supplying and stacking of hard stone ( for stone ptching ) 22.5cm thick at site
Dry stone pitching 22.5cm thick laid in courses and required proile with hammer dressed stone having no side less than 15 cm with minimum depth of 20cm including preparing the bedding surface etc.all complete
DRAINAGE Making soak pit 2.5m dia.3.0m deep with 45x45 cm dry brick honey comb shaft with bricks and S.W.drain pipe 100mm dia.,1.8m long complete as per standard design with common burnt clay F.P.S.( non modular ) bricks of class designation 7.5
Providing and fixing in position pre cast R.C.C.manhole cover and frame of required shape and approved quality Circular shape 560mm internal dia.
Providing and fixing in position pre cast R.C.C.manhole cover and frame of required shape and approved quality Rectangular shape 600x450 mm internal dimension
Rain Water Harvesting Pit EARTH WORK Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m. All kinds of soil.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil.
Extra for every additional lift of 1.5m or part thereof in excavation / banking excavated or stacked materials
CONCRETE WORK Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. 1:3:6 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
R.C.C. WORK Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately) All works upto Plinth level concrete of M25 grade with minimum cement content of 330 kg/cum
Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars
Centering and shuttering including strutting, propping etc. and removal of form for : Foundation, footing, bases of columns etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors,roof,landing,balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for : walls ( any thickness ) including attached pilasters,butteresses,plinth and string courses etc.
Brick work Brick work with F.P.S. bricks of class designation 7.5 in foundation and plinth in cement mortor 1:6 : a) Cement mortar 1:6 (1 cement : 6 coarse sand)
FINISHING 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).
Road work Supplying and stacking of hard stone ( for stone ptching ) 22.5cm thick at site
Dry stone pitching 22.5cm thick laid in courses and required proile with hammer dressed stone having no side less than 15 cm with minimum depth of 20cm including preparing the bedding surface etc.all complete
DRAINAGE Providing and fixing in position pre cast R.C.C.manhole cover and frame of required shape and approved quality Rectangular shape 600x450 mm internal dimension
Rantu Baruah
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.92 MB
FOB.pdf
Additional Documents • 0.12 MB
BOQ_60971.xls
BOQ • 0.76 MB
SBD_Heliport.pdf
Tender Documents • 4.54 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .