Executive Engineer
Office of the Executive Engineer, Project Division, Public Works Department, 102, Vallam Road, ArulanandaNagar, Ground Water Circle Campus, Near Sangam Hotel, Thanjavur-613 007.
Providing AC Arrangements to the Principal Room in Newly Constructed Government Arts and Science College at Vadalur in Cuddalore District.
2026_HE_718549_1
5M-1/PWD/PD-TNJ/2026-2027
Open Tender
Electrical Works
Lump-sum
GASC at Vadalur in Cuddalore District
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
28 Oct 2026
28 Oct 2026
12 Nov 2026
28 Oct 2026
12 Nov 2026
28 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, erection, testing and commissioning of 2 TR (4500 K. cal/ hr) split type Air conditioner conforming to IS: 1391 (Part-2) 1992 with Amdt No.1 to 2 fitted with compressor operating on non CFC refrigerant suitable for wall mounting for operation on 230V, 50 HZ single phase AC supply with 3 star rating as per BEE specification and capable of performing the functions of
1)Cooling, 2)Dehumidifying, 3)Air circulating, 4)Filtering.
The installation works for the above split type A.C units includes the following.
1. Mounting or Fitting indoor and outdoor units at their respective locations.
2. Laying refrigerant copper pipe lines of (5/8" & 3/8") 3 meters length including drilling holes in the wall if required. Thickness of the copper tubing shall not be less than 0.7mm.
3. Insulating the suction pipe with expanded polyurethelene foam 5mm thick tubing.
4.Laying 25mm PVC drain pipe of 6 mts. Length to drain out the condensate water being formed in the indoor unit.
5.Leak testing the entire gas unit.
6.Charging refrigerant gas in the unit.
7.Suitable electric wiring to be provided with 3 core 2.5sq.mm PVC insulated copper wire between indoor and outdoor units up to 3 meters length and up to switch within 3 meters of location of indoor unit. Carrier or Voltas or Daikin or equivalent. | 1 | Each | - | - |
| 2 | Supply and fixing of 5 kVA electronic automatic voltage stabilizer with input range of 170-270V and output range 200-240 V with high and low voltage cut off and 3 minutes time delay relay suitable for operation on 230V/50Hz single phase AC supply | 1 | Each | - | - |
| 3 | Supply and fixing of water drain pipe line (1” PVC Pipe) | 10 | Rm | - | - |
| 4 | Supply and fixing of MS stand for fixing outdoor unit | 1 | Each | - | - |
| 5 | Supply and fixing of 5/8” and 3/8” copper pipes (Extra beyond 3metres supplied with AC unit) with insulation foam of 6mm thickness suitable for split type AC unit | 3 | Each | - | - |
| 6 | GST 18% | 1 | No | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.14 MB
5-1-Tenderdocument.pdf
Tender Documents • 0.40 MB
BOQ_862983.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .