| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.3 LAccepted-AOC | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹22.4 L+₹1.1 L (4.93%)Rejected-Finance 37 PUNJABI COLONY NEAR RAILWAY CROOSING ARYA SAMAJ ROAD MATHURA U P | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹23.7 L+₹2.4 L (11.1%)Rejected-Finance | L3 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 4 | L4₹24.8 L+₹3.4 L (16.0%)Rejected-Finance NADUA GAON POST NADUA DIKOM DIST DIBRUGARH ASSAM 786 101 | DIBRUGARH | DIBRUGARH | ASSAM | 786101 | L4 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 5 | L5₹26.3 L+₹5.0 L (23.3%)Rejected-Finance | L5 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
16 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE EAST MATHURA
Garrison Engineer East Military Engineer Services Mathura Cantt Mathura 281001
PERIODICAL SERVICES AND REPAIR TO RCC CHAJJAS FACIA COLUMNS BEAMS AND CONNECTED ITEMS TO INTERNAL AND EXTERNAL SURFACES OF BLDGS IN NHL OHL AREA UNDER GE EAST MATHURA
2022_MES_540886_1
8200-1292/E8
Open Tender
Civil Works
Item Rate
180 days
GE EAST MATHURA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE EAST MATHURA
₹90,000
Yes
20 Sept 2022
26 Jul 2022
18 Aug 2022
26 Jul 2022
16 Aug 2022
10 Aug 2022
26 Jul 2022 - 16 Aug 2022
Amount
M&L for preparation of old plastered surface of walls and applying one coats of cement base paint complete all as specified and as directed.
M&L for complete removal of existing treatment from old plastered surfaces of walls and applying two coats of cement base paint complete all as specified and as directed.
M&L for preparation of old plastered surface of walls and applying one coats of exterior emulsion paint complete all as specified and as directed.
M&L for preparation of old painted wooden surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for preparation of old painted steel surface of any description not otherwise described over 10 cm in width or girth and applying one coat of synthetic enamel paint all as specified and as directed
M&L for complete removal of existing treatment and preparation of old surface by brooming down of steel wire brushing, scrapping down smoke soot, mould,moss and efforescent salts and trading oil and grease spouts and applying two coats of oil bound distemper complete all as specified and as directed.
M&L for preparation of old plastered surface of walls and applying one coats of oil bound distemper complete all as specified and as directed.
M&l for preparation of old plastered surfaces of walls and applying one coat of white wash complete all as specified and as directed.
M&L for preparation of old plastered surface of ceiling and applying one coats of white wash all as specified and as directed.
M&L for Providing 1 mm thick wall care putty on plastered surfaces of walls complete all as specified and as directed.
Taking down Cement plaster from brick walls or concrete surface etc including raking out joints, hacking for key and scrubbing down with water etc complete all as specified and as directed.
M&L for rendering 15mm thick on fair face of brick work/concrete surface in cement mortar 1:6 and finished surface even and fair without using extra cement complete all as specified and as directed.
M&L for preperation of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and as directed.
M&L for rendering 10 mm thick on fair faces of bricks or concrete surfaces as in ceiling surfaces in cement mortar 1:3 finish the surface even and fair without using extra cement complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and as directed.
M&L for providing damp proof layer in two coats of acrylic polymer coating consisting of 1 part of acrylic polymer liquid mixed with 2 parts of cementious powder applying at the rate of 1.40 Kg /Sqm of mix per coat. Second coat should be applied after 4-6 hrs of first coat, 5 days curing is to be carried out to the surface before providing plastering. Note : Make of the material 'Smart Care damp block 2K' of Asian paints or equivalent from Dr Fixit/STP/CICA as approved by GE.
M&L rendering 15mm thick (10mm + 5mm) on other than fair face of brick work or concrete surface in CM 1:4 by mixing liquid water proofing compound as per manufacturers instructions and finish the surface even and fair complete all as specified and as directed. Note :- Liquid WPC shall be measured & paid seprately under relevant item of this BOQ.
Supply only liquid water proofing compound complete all as specified and as directed.
M&L preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed.
M&L Obliterating old writing of any description n.exc 0.10 sqm with paint to match the existing work complete all as specified and as directed.
M&L for Writing letters or figures (Block, Roman, Italic or Indian) n.exc 30 Cm high complete all as specified and as directed.
S&F in repair PVC (SWR) pipes 110 mm bore single socketed in any length with rubber ring joints fixed to walls with and including MS clamps of size 25x3mm at 2.0 M interval complete all as specified and as directed.
S&F in repair PVC (SWR) pipes 75 mm bore single socketed in any length with rubber ring joints fixed to walls with and including MS clamps of size 25x3mm at 2.0 M interval complete all as specified and as directed.
Demolition of reinforcement cement concrete of any description and position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and as directed.
M&L for 50mm thick sand stone slab as in chajja /cover slab set and jointed over supports in cement mortar 1:4 complete all as specified and as directed.
S&F rolled mild steel in joist, channel, angle or Tee section fixed independently without connecting plate etc cut to ordinary length i.e. within 20 mm of length indicated) of Fe 410 Gde E-250 quality including preparation of steel surface and applying two coat of synthetic enamel paint over a coat of primer complete all as specified and as directed.
M&L for Providing, cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in coping, kerbs, roof padding etc as directed mixed with liquid water proofing compound as per manufacturer's instructions complete all as specified and as directed.
M&L for Cutting grooves in brick wall, 75mm wide and 65mm deep for fixing joist,angle, channel section and sandstone slab in chajjas upto G+2 floors and finishing face of groove with cement mortar 1:3 complete all as specified and as directed.
Demolition of brick work or stone boulder masonary built in cement mortar including all quoins arches, pillars etc. but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and as directed.
M&L for Brickwork using fly ash old size bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed.
M&L for chipping of unsound/deteriorated cement concrete up to 50mm average thickness from slabs, beams, columns, chhajjas etc with manual chisel including tempering of all edges including cleaning of exposed concrete surfaces and reinforcement with wire brushes etc and disposal of debris complete all as specified and as directed.
M&L for Identifying and marking carefully the damaged reinforced concrete by tapping with light hammer and chipping of unsound weak concrete and plaster material from slabs/beams/columns etc. with power/hand driven chisel as directed by the engineer-in-charge upto 40 mm average depth including saw-cutting of all edges making square shoulders of the cavities all as specified and as directed. Note :- (i) Debris obtained from chipping of loose/unsound and cracked concrete shall be removed out side of MD land. (ii) Thickness will be measured excluding plaster
M&L for Identifying and marking carefully the damaged reinforced concrete by tapping with light hammer and chipping of unsound weak concrete and plaster material from slabs/beams/columns etc. with power/hand driven chisel as directed by the engineer-in-charge upto 60 mm average depth including saw-cutting of all edges making square shoulders of the cavities all as specified and as directed. Note :- (i) All loose unsound and cracked concrete shall be removed out side MD land. (ii) Thickness will be measured excluding plaster
M&L for cleaning loose concrete if any all around reinforcement including from behind the reinforcing bars to give an average 10 mm thick (but not less than 10 mm clear air gap) and cleaning reinforcement of total rust using alkaline rust remover with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washed with water and allowing it to dry complete all as specified and as directed. Note : - (i)Length of reinforcement bars any dia cleaned of rust all around will be measured for payment. (ii) Thickness will be measured excluding plaster.
M&L applying two coats of epoxy based passivating, protecting & bonding coat of zinc rich system (Nitozinc (R) primer of Fosroc and equivalent of SIKA/Dr Fixit Pidilite/ Krishna Conchem) as approved by the Engineer-in-Charge for old and new reinforcement any dia complete all as specified and as directed. Note :- Epoxy based passivating, protecting & bonding coat of zinc rich system will be paid for separately.
Supply only epoxy based passivating, protecting & bonding coat of zinc rich system (Nitozinc (R) primer of Fosroc and equivalent of SIKA/Dr Fixit Pidilite/ BASF) as approved by the Engineer-in-Charge. Note :- Payment will be made for the total weight of resin and hardener in manufactured specified proportion.
Mixing and applying SBR latex modified cementitious bond coat using cement 2.2 kg per square metre on prepared concrete surfaces of parent material complete all as specified and as directed. Note :- SBR latex will be paid for separately.
Mixing and applying SBR latex modified cement mortar 25 mm thick in cement sand mortar in proportions of 1:3 (1 cement and 2 graded quartz aggregate) with polymer admixed in proportions as approved, including trowelling with wooden tools on prepared concrete surfaces of parent material complete all as specified and as directed. Note :- Acrylic polymer will be paid for separately.
Supply only approved SBR latex from FOSROC/BASF/DR FIXIT/ SIKA for bonding coat/Polymer modified cement mortor complete all as specified and as directed. Note: Rate shall be in terms of solid contents of polymer.
M&L for prepration of new plastered surface of walls and applying two coats of exterior emulsion paint (Apex) over a coat of primer complete all as specified and as directed.
M&L for in repairs150 mmx150mm salt glazed stone ware gully traps square or round mouthed, type 'P' and setting and joining in cement mortar 1:1 complete all as specified and as directed.
S&F in repair 110 mm bore PVC (SWR) vent cowl omplete all as specified and as directed.
S&F in repair 110 mm dia PVC (SWR) bends any radius with oval access door complete all as specified and as directed.
S&F in repair 75 mm dia PVC (SWR) bends any radius complete all as specified and as directed.
S&F in repair 110 mm bore PVC (SWR) branch piece single (single 'Y') equal or unequal complete all as specified and as directed.
S&F in repair 75 mm bore PVC (SWR) junction single (single 'T') complete all as specified and as directed.
M&L for providing and placing in position micro concrete, grade M-40, which shall be cement based prepacked single component, chloride free, non shrink, free from flowing , self compacting ready to use after mixing in water proportion, obtained from Fosroc/SIKA/BASF/Dr Fixit. Thickness of section upto 75 mm complete all as directed. Note: Payment under this item shall be made only after proper wet curig has been done and surface has been satisfactorily evaluated by sounding/tapping with a plunt metal instrument.
shyam construction
B S ENTERPRISES
M/S United Builders
B R ENTERPRISES
M/s M S CONSTRUCTION
Ms Kamal Kant Agarwal
M/S ANIL KUMAR
VASUNDHARA AND COMPANY
ASHUTOSH BUILDERS
ARCHI ENGINEERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .