Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.8 LAccepted-AOC | L1 | Accepted-AOC L1 Quoted | |
| 2 | L2₹13.4 L+₹74,330 (5.89%)Rejected-AOC | L2 | Rejected-AOC L2 Quoted | |
| 3 | L3₹14.6 L+₹1.9 L (15.3%)Rejected-AOC | L3 | Rejected-AOC L3 Quoted | |
| 4 | L4₹15.8 L+₹3.2 L (25.2%)Rejected-AOC | L4 | Rejected-AOC L4 Quoted | |
| 5 | L5₹16.0 L+₹3.4 L (26.5%)Rejected-AOC DHARAM SALA SINGHAN CHADOORA DISTT BUDGAM J K | CHADOORA | BUDGAM | JAMMU AND KASHMIR | L5 | Rejected-AOC L5 Quoted |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
15 Oct 2020, 6:00 pmClosed
GE AF SRINAGAR
GE AF SRINAGAR 190007
REPAIR MAINT OF GEYSERS, SUMMER APPLIANCES WITH CONNECTED WORKS EARTHING AND LIGHTING ARRESTOR AT AF STATION SRINAGAR
2020_MES_378652_1
GE (AF)-34/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE AF SRINAGAR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE AF SRINAGAR
₹40,000
Yes
7 Dec 2020
18 Sept 2020
17 Oct 2020
18 Sept 2020
15 Oct 2020
1 Oct 2020
Amount
Disconnecting all water and electric connections of geysers and taking down carefully installed storage type electric geysers of any capacity of any make/type/size (horizontal/vertical) lowering and setting aside opening geysers examining and checking thoroughly for requisite repair/ replacement of defective/worn-out/ unserviceable components/parts materials including preparing inventory for each geyser separately in presence of Engineer-in-Charge and removing all scale and dirt de-scaling of deposited in inner copper tank and outer tank and heating elements by HCL or aqua clear pedilite solution, thermostat, indicator lamp, assemble checking electrical connection, stopping of minor leaking by soldering/brazing of the inner copper tank and replacement of defective worn out unserviceable components/parts (new components/parts shall be measured and paid separately as supply only herein after) & re-fixing geyser in its original location including hoisting, connecting to water & electric connection and testing for proper functioning of geysers including earthing to the entire satisfaction of the Engineer-in-Charge.
Note -Employing skilled electrician and helpers per day required with necessary tools, safety equipments for attending geyser and fan complaint complete all as specified and as directed by Engineer-in -charge.
Supply only Heating element 2 KW as per sample suitable geyser of any capacity.
Supply only Heating element 3 KW as per sample suitable geyser of any capacity.
Supply only Heating element 1.5 KW as per sample suitable geyser of any capacity.
Supply only Thermostat switch 230 volts, 50 cycles AC suitable for geysers of any capacity geyser as per existing make
Supply only Fiber reinforced PVC nylon pipe (Flexi connection pipe) heavy duty size 450 mm long 15mm bore with brass coupling chromium plated with rubber washers as both ends as per IS.
Supply only Base assembly (seperator) suitable for 25/50 ltr capacity of geyser as per existing make,size and type with holding clamp with nut bolts,washer and rubber gasket for element and thermostate and other accessories as required at site etc complete all as specified and as directed by Engineer-in -charge.
Supply only heavy duty pin type fastener 4" long (GI nuts & bolts and washers off sizes) suitable for any capacity geyser as required at site.
Supply only stainless steel tank and rated pressure not less than 7kg/sqcm etc as per existing size,shape,make suitable for 50 ltrs geysers.
Supply only stainless steel tankand rated pressure not less than 7kg/sqcm etc as per existing size,shape,make suitable for 25 ltrs geysers.
Supply only indicator lamp as per existing shape and size suitable for 25/50 ltrs capacity of geyser etc complete all as specified and as directed by Engineer-in -charge.
Supply only Metallic fusable plug of existing make/type/size suitable for geyser any capacity.
Supply only Rubber ring gasket superior/made out rubber having holes to suit the hole of base plate suitable for any capacity geysers
Supply only PVC copper cable flexible 3 core round heavy duty size 40/0.0076 suitable for geyser any capacity
Supply only three pin plug top ISI marked of capacity 15/16A, 230 volts
Supply only safety valve ISI marked for any make and any capacity of geyser, complete all as specified and approved by Engineer-in -charge.
Supply only bottom cover made out of MS sheet 20 guage as per existing size & hole incl machine screws suitable for 25/50 ltr geysers of any make and type complete all as specified and as directed by Engineer-in -charge.
Material and Labour for Painting of geyser 25 Ltrs after scraping, cleaning, knotting and stopping including preparation of surface of geyser and rubbing with ammery paper for painting with one coat of duco paint by spray painting machine to achieve glossy finish of approved make first quality and re write MES No. on the body of geyser with black synthetic enamel paint (letters and figures 2cm high ) complete all as specified and as directed by Engineer-in -Charge.
Material and Labour for Painting of geyser 50 Ltrs after scraping, cleaning, knotting and stopping including preparation of surface of geyser and rubbing with ammery paper for painting with one coat of duco paint by spray painting machine to achieve glossy finish of approved make first quality and re write MES No. on the body of geyser with black synthetic enamel paint (letters and figures 2cm high ) complete all as specified and as directed by Engineer-in -charge.
Supply and Fixing Sheet metal enclosure single pole and neutral with 2 pin earth metal plug and socket with one single pole MCB 20 A, 230 volts etc. as in repairs complete all as specified and as directed by Engineer-in -Charge. Make: Legrand/ABB/Siemens/Schneider
Supply and Fixing Steel Metal clad industrial plug & socket 2 pole + earth 250 volts 20 A etc. as in repairs complete all as specified and as directed by Engineer-in -charge. Make: Legrand/ABB/Siemens/Schneider
Supply and Fixing Switch socket combination 5 in 1, 5/16 Amp flush type ISI marked, 250 Volt etc. as in repairs complete all as specified and as directed by Engineer-in -charge. Make: Legrand/ABB/Siemens/Schneider
Supply and Fixing MCB single pole 240 volts ISI marked of capcity 16 Amps `C' series etc. as in repairs complete all as specified and as directed by Engineer-in -charge. Make: Legrand/ABB/Siemens/Schneider
Supply and Fixing MCB single pole 240 volts ISI marked of capcity 6 Amps `C' series etc. as in repairs complete all as specified and as directed by Engineer-in -charge. Make: Legrand/ABB/Siemens/Schneider
Supply and Fixing MCB single pole and neutral 240 volts ISI marked of capcity 40 to 63 Amps C; series etc. as in repairs complete all as specified and as directed by Engineer-in -charge. Make: Legrand/ABB/Siemens/Schneider
Supply and Fixing in replacementStorage type water heater 5 star rated,50 ltrs capacity vertical wall mounting type made out of CRCA outer body, stainless steel storage tank, titanium enamelled heating element, thermostate, thermal cutout, glass wool including fiber reinforced PVC nylon pipe (flexi connection pipe) heavy duty size 450mm long and 15mm bore with brass coupling chromium plated with rubber washer at both ends as per IS complete including making necessary electrical and water connections with 2.5 sqmm 3 core copper (multistranded) cable with top indicator plug top 15 amp from geyser connnection to socket incl hold fast for fixing of new geyser and writing the MES No and taking out unserviceable geyers complete all as specified and as directed by Engineer-in -charge. Make Havells (Monza turbo)/Racold /Jaguar
Supply and Fixing in replacement Storage type water heater 5 star rated,25 ltrs capacity vertical wall mounting type made out of CRCA outer body, stainless steel storage tank, titanium enamelled heating element, thermostate, thermal cutout, glass wool fiber reinforced PVC nylon pipe (flexi connection pipe) heavy duty size 450mm long and 15mm bore with brass coupling chromium plated with rubber washer at both ends as per IS complete including making necessary electrical and water connections with 2.5 sqmm 3 core copper (multistranded) cable with top indicator plug top 15 amp from geyser connnection to socket incl hold fast for fixing of new geyser and writing the MES No and taking out unserviceable geyser complete all as specified and as directed by Engineer-in -charge. Make Havells (Puro Plus)/Racold /Jaguar
Taking down carefully ceiling fan from the existing position from any height and any sweep and make for overhauling including dismantling of blade frame and opening and examining motor cleaning of dust/dirt of fan cleaning and greasing of ball bearing and bushes with fresh oil and best quality of grease respectively and reassembling of complete fan after re-fixing parts in its original location and hanging connecting and testing ceiling fan for smooth functioning incl replacement of rubber real insulator and painting with one coat of synthetic enamel paint with spray painting machine & marking MES No. with black paint complete.Note : Bearing, bush, condenser and insulated cable if required will be measured and paid separately. NOTE: Spare parts shall be measured and paid seprately under respective item of schedule
Supply only fan condeser 2.5/3.15 mfd suitable for 240 volts etc complete all as specified and as directed by Engineer-in -charge.
Supply only ball bearing of ceiling fan (size 48''/56''/60'') of exactly similar as existing in fans complete all as specified and as directed by Engineer-in -charge.Make:NBC/SKF
Supply only gun metal bush of ceiling fan (size 48''/56''/60'') of exactly similar as existing in fan complete all as specified and as directed by Engineer-in -charge. Make:NBC/SKF
Supply only PVC sheathed white colour three core copper flexible cable of size 23/.0076complete all as specified and as directed by Engr-in-Charge.
Material and Labour for Rewinding of Ceiling Fan any make of 1200/1400 mm sweep make with super enameled copper wire (gauge/weight of copper coils shall be same as per existing dismantled fans), including varnishing & heating, testing etc complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing Ceilling fan blade of 1200/1400 mm sweep as per sample complete all as specified and as directed by Engineer-in -charge.
Taking down carefully exhaust fan/wall fan/pedustal fan/table fan any sweep and make for overhauling including dismantling of blade frame and opening and examining motor cleaning of dust/dirt of fan cleaning and greasing of ball bearing and bushes with fresh oil and best quality of grease respectively and reassembling of complete fan after re-fixing parts in its original location and hanging connecting and testing fan for smooth functioning incl replacement of rubber real insulator and painting with one coat of synthetic enamel paint with spray painting machine & marking MES No. with black paint complete.Note : Bearing, bush, condenser and insulated cable if required will be measured and paid separately. NOTE: Spare parts shall be measured and paid seprately under respective item of schedule
Supply only fan condeser 4/6 mfd suitable for 240 volts etc complete all as specified and directed by Engineer-in-charge.
Supply only ball bearing of ceiling fan (size 18''/15''/12'') of exactly similar as existing in fan complete all as specified and as directed by Engineer-in -charge.
Supply only gun metal bush of ceiling fan (size 18''/15''/12'') of exactly similar as existing in fancomplete all as specified and as directed by Engineer-in -charge.
Supply only PVC sheathed white colour three core copper flexible cable of size 23/.0076complete all as specified and as directed by Engineer-in -charge.
Material and Labour for Rewinding of exhaust Fan of 18 inch/ 15 inch sweep any make with super enameled copper wire (gauge/weight of copper coils shall be same as per existing dismantled fans), including varnishing complete all as specified and directed by Engineer-in-Charge.
Material and Labour for Rewinding of exhaust Fan of 9 inch/ 12 inch sweep size of fans of any make with super enameled copper wire (gauge/weight of copper coils shall be same as per existing dismantled fans), including varnishing complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing MS louvers of size 450mm to 300 mm sweep of exhaust fan etc. as in repairs complete all as specified and as directed by Engineer-in -charge.
Supply and Fixing in replacement Non metalic exhuast fan 250/300 mm sweep suitable 240 volts and taking out unserviceable fan complete all as specified and as directed by Engineer-in -charge. Make- Havells/Usha/Khaitan
Supply and Fixing in replacement Heavy duty exhuast fan 450mm, 900 rpm turbo force model single phase incl all accessories as per manufacturer norms and taking out unserviceable fan complete all as specified and as directed by Engineer-in -charge. Make -Havells/Usha/Khaitan
Supply and Fixing in replacement Heavy duty exhuast fan 600mm, 900 rpm turbo force model single phase incl all accessories as per manufacturer norms and taking out unserviceable fan complete all as specified and as directed by Engineer-in -charge. Make -Havells/Usha/Khaitan
Supply and Fixing in replacement Heavy duty exhuast fan 300mm, 900 rpm turbo force model single phase incl all accessories as per manufacturer norms and taking out unserviceable fan complete all as specified and as directed by Engineer-in -charge. Make -Havells/Usha/Khaitan
Supply and Fixing in replacement Wall fan 400 mm sweep with all accessories as per manufacturer norms and unserviceable fan complete all as specified and as directed by Engineer-in -charge. Make:- Havells (Platina HS) /Usha/Khaitan
Supply and Fixing Ceiling fan 1200mm sweep with all accessories as per manufacturer norms and taking out unserviceable fan complete all as specified and as directed by Engineer-in -charge. Make- Havells/Usha/Khaitan
Supply and Fixing Socket outlet 2 in 1, 3 pin 5 Amps flush type 240 volts ISI marked etc. as in repairs complete all as specified and as directed by Engineer-in -charge.
Supply and Fixing Fan regulator stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as in repairs complete all as specified and as directed by Engineer-in -charge.
Supply and Fixing PVC gang box with 6Amp 2 in 1, 3 pin 6 Amps switch socket combination suitable for 240 volts etc. as in repairs complete all as specified and as directed by Engineer-in -charge.
Supply and Fixing PVC gang box 6Amp 2 in 1, 5 pin 16 Amps switch socket combination suitable for 240 volts etc. as in repairs complete all as specified and as directed by Engineer-in -charge.
Renewal of existing earthing (GI plate earthig) with provision of new layers of charcoal and salt all as specified in electrical plate No 3 of SSR Part-I, including cleaning of existing GI earth plate, conductors etc., connecting with new bolts, nuts and washers brazing same material complete including testing on completion all as directed. Note: - Excavation, PCC for earth pit and cover, watering pipe, funnel with wire mesh, earth lead and protection pipe shall be measured and paid separately.
Renewal of existing earthing (Copper plate earthig) with provision of new layers of charcoal and salt all as specified in electrical plate No 3 of SSR Part-I, including cleaning of existing GI earth plate, conductors etc., connecting with new bolts, nuts and washers brazing same material complete including testing on completion all as directed. Note: - Excavation, PCC for earth pit and cover, watering pipe, funnel with wire mesh, earth lead and protection pipe shall be measured and paid separately.
Excavation in trenches, n. exc 1.5 m wide and n. exc 1.5m depth and getting out for foundation of poles, stay,laying of cable and pipe in any type of soil complete all as specified and directed
All as per item No 31 here-in-before but depth exceeding 1.50 m and not exceeding 3.00 m deep complete all as specified and directed.
Returing, filling in including spreading, levelling, watering and well ramming in layers n exc 25cm thick after laying of the cables complete all as specified and directed.
Removing excavated material to a distance not exceeding 50 m & depositing where directed at a level not exceeding 1.50 m above the starting point complete as specified and directed.
supply and Fixing CI funnel with wire mesh made as specified in SSR Part -I electrical plate No 3 fixed with GI watering pipe by welding or threading etc as in repair complete all as specified & directed by Engineer-in-Charge.
supply and Fixing Tubes, light grade, galvanised fixed single length in earthing pit of size 20 mm dia including taking down of old steel tubing complete all as specified & directed by Engineer-in-Charge.
supply and Fixing Tubes, light grade, galvanised with all fittings and fixed complete to walls/earthing pit of size 15 mm dia including taking down of old steel tubing complete all as specified & directed by Engineer-in-Charge.
supply and Fixing Tubes, light grade, galvanised with all fittings and fixed complete to walls/earthing pit of size 50 mm dia including taking down of old steel tubing complete all as specified & directed by Engineer-in-Charge.
supply and Fixing Galvanised iron strip as earth continuity conductor or main earthing lead fixed to walls or burried in ground of size 25x4mm complete all as specified & directed by Engineer-in-Charge.
supply and Fixing Galvanised iron strip as earth continuity conductor or main earthing lead fixed to walls or burried in ground of size 32x6mm complete all as specified & directed by Engineer-in-Charge.
supply and Fixing Aluminium strip 25 x 3 mm with saddles/ceramic spacers and fixing screws for roof conductors and down conductors as existing at site above ground complete all as specified and directed by Engineer-in-Charge
supply and Fixing Copper strip 20 x 3.15 mm with saddles/ceramic spacers and fixing screws including brazing work with brazing equipment etc for roof conductors and down conductors as existing at site above ground complete all as specified and directed by Engineer-in-Charge
supply and Fixing Copper strip 32 x 6 mm with saddles/ceramic spacers and fixing screws including brazing work with brazing equipment etc for roof conductors and down conductors as existing at site above ground complete all as specified and directed by Engineer-in-Charge
Material and Labour for Plain cement concrete type C-2, 1:3:6 using 40mm graded stone aggregate,for earth pit including necessary formwork complete all as specified and directed by Engineer-in-Charge.
supply and Fixing Copper earth plate of size 60x60x3.15mm thick etc complete as specified and directed
supply and Fixing GI earth plate of size 60x60x6mm thick etc complete as specified and directed
Supply & fixing for GI wire 4 mm dia etc complete all as specified & directed by Engineer-in-Charge.
Material and Labour for Watering with salt (5:1) ratio in existing earthing to acheive desired test results and other equipment required at site in AF stn Srinagar etc complete specified and directed by Engr-in-charge . Note- (i) Test result should be prepared on seperate register and signed by mes representative (ii) The test will be carried out in every month or as directed (iii) cleaing the surrounding earth pits approx 1.0 mtr radius (iv) Test result should be less than 1 ohms
Material and Labour for Brazing the GI strip joint of any size and any thickness with two nos GI nut,bolt,washer of each joint etc complete as specified and directed by Engr-in-charge
Material and Labour for Brazing the copper strip joint of any size and thickness with two nos copper nut,bolt,washer of each joint etc complete as specified and directed by Engr-in-charge
Material and Labour for Brazing the aluminium strip joint of any size and thickness with two nos copper nut,bolt,washer of each joint etc complete as specified and directed
Material and Labour for PVC post insulator suitable for mounting of GI/Copper strip of size 32x6mm or 25x3mm including GI/Copper nut and bolts as required etc complete as specified and directed by Engr-in-charge
Refixing only the hanging GI/Copper strip with suitable size nut,bolt washer of same material such as GI/Aluminium/Copper etc complete as specified and directed by Engr-in-charge
supply and Fixing magnisium/ copper sulphate, ISI marked laboratary tested complete all as specified and directed by Engineer-in-Charge
supply and Fixing Air termination, single pointed aluminium rod 12 mm dia and 300 mm long as in repair complete all as specified and directed by Engineer-in-Charge
supply and Fixing Air termination, single pointed copper rod 12 mm dia and 300 mm long as in repair complete all as specified and directed by Engineer-in-Charge
Material and Labour for Preparation of surfaces by removing rust/ dust by sand paper/ wire brush/ hand scrapping to obtain even surfaces of steel tubular pole 9 m long above ground levelincluding brackets, clamps etc and painting the same with one coat of Aluminium paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in -charge. Note:- The existing paint from air terminal, down conductor and test point fixed on the pole shall be removed properly by using sand paper and surface cleaned with thinner/ cleaning material to ensure proper conductivity of the path.
Material and Labour to carry out earth resistance test and neutral voltage for earthing with suitable earth resistance testing after opening the test point and recording the result in presence of user/ MES reppresentative all as per IS-3043: 1996 complete all as specified and as directed by Engineer-in -charge. Note:-1. In case of resistance value exceeds more than 5ohms and earth neutralvoltage more than 3 volts, the earthing shall either removed and replaced and for resistance value between 01 to 05 ohms, renewal of earthing shall be carried out, the renwal and or replacement shall be measured and paid separately. 2. Testing equipment shall be provided by contractor.
Material and Labour to carry out Ohmic resistance test and recording the resistance value of lightening protection system in presence of user/ MES reppresentative complete with Air termination but without earth connections by dividing the system into convenient sections at testing point by suitable joints and flowing continous current of above 10 Amps by using Kelvin Bridge or other suitable portable precision testing set all as per IS-2309: 1969 complete all as specified and as directed by Engineer-in -charge. Note:-1. Before testing, all the joints shall be cleaned by CRC solution, worn out/ missing nuts, bolts, washers, rivets etc shall be replaced and roof/down conductors shall be straightened.. 2. Testing equipment shall be provided by contractor.
S & F 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed for service connections suspended by insulating hangers not more than 1 mtr apart incl 4 mm suspension wire twin core cable circular of size 10 Sq mm complete all as specified.
Earth pit chamber PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) 40mm thick cover, reinforced with 6mm dia bars 3 Nos both way with 12mm dia round bar handle as specified in SSR 2009 Part I Electrical Plate No 3 incl taking out broken pits and deposited as directed place and marker made out of 1.6 mm thick MS plate (30x30 cm size,welded with 12 mm dia round MS bar incl painting with one coat of red oxide primer and two coat of synthetic enameld paint and writing the earth pit no and result as directed hight letter etc as in repair complete as specified and directed by Engr-in-charge
Supply and Fixing switch Socket combination 2 in 1, 3 pin 15 Amps flush type 240 volts ISI marked universal as in repairs complete all as specified and as directed by Engineer-in -charge.
Note for all items :All repair work shall be carried out only by authorised person qualified in the relevant trade (ii) Make of components replacement if not specifically mentioned in the relevant item/List Of Make same shall be of the existing make.
M/S FAROOQ AND SONS
M/S GHULAM HASSAN KUCHAY
M/S NEW FAROOQ TRADERS
M/s Jaipal Associates
M/S GULAM AHMAD ABDUL SAMAD
yattoo contractors
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .