GE(AF) JORHAT
REPAIR/MAINT OF UNDERGROUND CABLE, JOINT KIT, LT FEEDER PILLAR BOX AND ALLIED ACCESSORIES IN DOMESTIC AREA, COMPREHENSIVE REPAIR/ MAINT OF STANDBY POWER SUPPLY SYSTEM AT CERTAIN INSTALLATIONS AT 5 AFH UNDER GE (AF) JORHAT
2023_MES_617878_1
8562/E8
Open Tender
Civil Works
Item Rate
180 days
JORHAT AIRFORCE STATION
AS PER NIT
9 documents required · 9 mandatory
₹500
GE(AF) JORHAT
₹80,000
Yes
7 Nov 2023
8 Sept 2023
12 Oct 2023
8 Sept 2023
10 Oct 2023
23 Sept 2023
Amount
Taking down / out unserviceable or serviceable UG cables of any cross sectional area and connections including bricks, etc. of any descriptions, laid in trenches and /or fixing with walls /poles including segregating of serviceable materials viz bricks, cables, etc. and kept in safe custody for re-use complete all as specified and as directed. NOTE : Earth Work shall be measured and paid separately under relevant Items here-in-after.
Excavation in trenches not exc. 1.50m wide and not exc. 1.50m in depth and getting out in soft / loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25cm thick in soft/loose soil complete all as specified and as directed.
Removing excavated materials not exc. 50m and depositing where directed at a level not exc.1.50m above the starting point complete all as specified and as directed.
M&L for cable in trenches or passing through pipe/ on wall, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade, cross sectional area 6sq.mm, 4 core complete all as specified and directed. Note: Rate of the saddle and clamp for fixing of cable on wall is included in this rate.
All as per Serial item No. 5 here-in-before but of size 10Sq.mm 4 Core.
All as per Serial item No. 5 here-in-before but of size 16Sq.mm 4 Core.
All as per Serial item No. 5 here-in-before but of size 120Sq.mm 3.5 Core.
All as per Serial item No. 5 here-in-before but of size 240Sq.mm 3.5 Core.
All as per Serial item No. 5 here-in-before but of size 300Sq.mm 3.5 Core.
All as per Serial item No. 5 here-in-before but of size 400Sq.mm 3.5 Core.
M&L for re-laying and re-routing of serviceable XLPE LT UG cable, insulated, armoured with aluminium conductor, 1100 Volt grade, nominal cross-sectional area 16Sq.mm to 50Sq.mm of any core including brass compression cable gland, terminal lug, etc. complete all as specified and as directed. Note : Excavation, sand, bricks and connected items shall measured and paid separately.
All as per serial Item No. 12 here-in-before but of size 70Sq.mm to 95Sq.mm of any core.
All as per serial Item No.12 here-in-before but of size 120Sq.mm to 185Sq.mm of any core.
All as per serial Item No.12 here-in-before but of size 240Sq.mm to 500Sq.mm of any core HT/LT cable.
M&L for sand cushioning (dry) in trenches for protection of UG cables (below, above and around the UG cable laid in trenches) of 230mm spread thickness and consolidated (punned) upto 180mm thickness complete all as specified and as directed. NOTE : For the purpose of payment, punning thickness of Sand cushioning shall only be measured and paid.
S&F sub-class 'B' brick, well burnt, laid breadth-wise along the length of cable laid in trenches over sand cushion laid for UG cable protection complete all as specified and as directed.
Re-laying only old brick in trenches for under ground cable over the sand cushioning for cable protection (serviceable bricks obtained from Item here-in-before) complete all as specified and as directed. Note : Old bricks retrieved shall be re-used.
Taking down/ out unserviceable GI / HDPE pipes of any size and descriptions, laid in trenches and /or fixing to wall / poles complete all as specified and as directed.
S&F 50mm bore high density polyethylene pipe (HDPE) of pressure rating 6 kgf/cm2 fixed to walls, ceilings or in floors, etc. complete all as specified and as directed .
S&F galvanised iron pipe of size 80mm bore, ‘light grade’ for protection of UG cable, laid in floors/ road crossing, fixing to pole with mild steel clamps, nuts, bolts, etc. complete all as specified and as directed.
All as per Serial item No. 21 here-in-before but 50mm bore of pipe.
Labour only for horizontal boring for passing protection pipe up to 80mm bore under road / foot path not exc. 10m in a single length complete all as specified and directed. Note : Pipe to be measured and paid separately.
M&L for straight through cable jointing kit including jointing materials for making joints of UG electric cable 1100 volts grade, heavy duty with PVC/XLPE insulated aluminium stranded conductor, nominal cross-sectional area 25Sq.mm to 50Sq.mm, 3.5/4 Core and testing complete all as specified and as directed.
All as per Serial item No. 24 here-in-before but for nominal cross-sectional area exc. 70Sq.mm, 3.5 Core.
All as per Serial item No. 24 here-in-before but for nominal cross-sectional area exc. 95Sq.mm, 3.5 Core.
All as per Serial item No. 24 here-in-before but for nominal cross-sectional area exc. 120Sq.mm to 185Sq.mm, 3.5/4 Core
All as per serial item No 24 here-in-before but for nominal cross-sectional area exc. 240Sq.mm to 300Sq.mm, 3.5/4 Core
All as per serial item No 24 here-in-before but for nominal cross-sectional area exc. 400Sq.mm, 3.5/4 Core.
M&L for cable jointing kit for 11KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sq.mm to 95 sq.mm and testing complete all as specified and as directed.
M&L for cable jointing kit for 11KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sq.mm to 95 sq.mm and testing complete all as specified and as directed.
M&L for cable jointing kit for 11KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120sq.mm to 185sq.mm and testing complete all as specified and as directed.
Supply and passing through steel tubular pole / service connection, 1100 volts grade heavy duty 4sq.mm size weather proof flat cable PVC insulated stranded aluminium conductor, twin core cable (BTC) complete all as specified and directed.
All as per Serial item No. 33 here-in-before but for size 2 core 6Sq.mm.
S&F as in repairs GI strip of size 32 x 6.0mm with saddles and fixing screws on porcelain insulator/ spacer fixed at every 1 mtr length for extension of earthing strip on roof/wall and joining the same with existing/new earth test point including taking down old unserviceable one complete all as specified and as directed.
M&L for repairing of LT existing panel doors welding, cutting, nuts, bolts, including doors hinges material, cleaning/ dressing of inner and outer part, crimping, replacement of gland, lugs, terminal nuts and bolts, Bus bar, MCCB, etc. complete all as required at site complete all as specified and as directed. NOTE : (i) Cost of replacement locking arrangement, hinges, T&P, welding materials, etc. are inclusive in above quoted rate. (ii) Rate are included for minor excavation around the LT panel for connection of incoming and outgoing cables. (iii) Item such as gland, lugs, terminal nuts and bolts, bus bar, MCCB, etc. shall be measured and paid separately.
M&L for painting of LT panel / feeder pillar any size after cleaning the body surface of transformer by rubbing with emery paper to remove rust, dust etc and applying two coats of synthetic enamel paint complete all as specified and as directed.
S&F aluminium bus bar 800 Amps TPN (each 3m long) with PVC sleeves (R,Y,B) complete all as specified and as directed.
S&F aluminium bus bar 600 Amps TPN (each 3m long) with PVC sleeves (R,Y,B) complete all as specified and as directed.
S&F HT 11 KV bus bar insulator with nut, bolts etc complete all as specified and as directed.
S&F cable route marker of 350mm hight including grounting and radium painting HT/LT cast iron complete all as specified and directed.
M&L for mild steel nuts, bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc. 5cm long and diameter of neck 5 to 10 mm complete all as specified and as directed.
S&F aluminium lugs complete all as specified and as directed of the following sizes : -
S&F MCCB 4 Pole 63 Amps with breaking capacity 25 KA, thermal & magnetic adjustable type 415volts, with extended copper terminals including taking out existing unserviceable / burnt MCCB from site complete all as specified and as directed.
All as per Serial item No. 44 here-in-before but 125 amps MCCB.
All as per Serial item No. 44 here-in-before but of 160 Amps MCCB, breaking capacity 36 KA.
All as per Serial item No 44 here-in-before but of 250 Amps MCCB, breaking capacity 36 KA.
All as per Serial item No. 44 here-in-before but of 400 Amps MCCB, breaking capacity 36 KA.
All as per Serial item No. 44 here-in-before but of 630 Amps MCCB, breaking capacity 36 KA.
S&F MCB DB SPN of 240 volts, 10 KA 'C' curve miniature circuit breaker 32 Amps and current carrying capacity with connection, testing and commissioning including taking out old existing unserviceable / burnt MCB from site complete all as specified and as directed.
All as per Serial item No. 50 here-in-before but MCB DB SPN 40 to 63 Amps.
S&F MCB DB of 415 volts, 10 KA 'C' curve Miniature circuit breaker of TP, 25 to 63 Amps and current carrying capacity with connection, testing and commissioning including taking out existing unserviceable / burnt MCB from site complete all as specified and as directed.
S&F MCB DB of 415 volts, 10 KA 'C' curve Miniature circuit breaker of TPN, 40 to 100 Amps and current carrying capacity with connection testing and commissioning including taking out existing unserviceable / burnt MCB from site complete all as specified and as directed.
S&F as in repairs change over switch (SS Enclosure) 4 pole, 415 volts, 50Hz, 200 Amps complete all as specified and as directed. Make : Havells, Cat No. IHCNFE0200 or its equivalent model from make as specified in particular specifications.
S&F as in repairs change over switch (SS Enclosure) 4 pole, 415 volts, 50Hz, 400 Amps complete all as specified and as directed. Make : Havells, Cat No. IHCNFE0400 or its equivalent model from make as specified in particular specifications.
S&F as in repairs copper strip 20 x 3.15mm with saddles and fixing screws on porcelain insulator/ spacer fixed at every 1 mtr length on roof/wall of building and joining the same with existing/new earth test point including taking down old unserviceable one complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete for road complete all as specified and as directed.
M&L for plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in coping and footing for poles, etc. including necessary form work complete all as specified and as directed.
S&F LED street light fitting 35 Watts 230 volts AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. Make : Crompton, Cat No. TRP-400-35-57-SL-LM-NSR or equivalent model make as specified in Particular Specifications.
S&F LED street light fitting 60 Watts 230 Volts AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. Make : Crompton, Cat No. TRP-409-60-57-GL-NSG or equivalent model make as specified in Particular Specifications.
S&F LED flood light 120 watt 230 Volts AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed. Make : Crompton, Cat No. TFS-504-120-57-60D-SL-GL-NSG or equivalent model make as specified in Particular Specifications.
S&F notice board pin up type, soft board core, framed in doublesided carved aluminium section and silver anodized with plastic corners and with necessary hanging arrangement on the wall complete all as specified and as directed.
Dismantling of ACSR or AAC conductorscomplete all as specified and directed. NOTE : The old existing unserviceable service line remain un-used/not further required are to be dismantled.
Dismantling concrete poles/ struts, any size including demolition of cement concrete (as/if required) and made good disturbed ground, and the pole is deposited to MES Store Yard complete all as specified and as directed. Note : (i) Unserviceable poles will be dismantled at ground level and disturbed ground will made good as directed for which earthwork, demolition of cement concrete, etc. will not be measured and paid separately. (ii) All the T&P, vehicle for transportation from site to MES Store Yard to be arrange by contractor and the rate is included in this schedule. No extra shall be paid to the contractor for transportation complete. (iii) The old existing unserviceable service line remain un-used/not further required are to be dismantled.
M&L for dismantling cross-arms of M.S. channel or angle sections etc. complete and setting a side for re-use with in 50m complete all as specified and as directed. NOTE : The old existing unserviceable service line remain un-used/not further required are to be dismantled.
M&L for painting of LT electric pole, steel tubular swaged pole (8.5m to 9m) of any size, any pattern with one coat of aluminium paint over a coat of red oxide primer in full length of the pole and marking the pole with black and yellow strip (up to 1m length, 1m height of PCC coping) alternatively including numbering the pole serially complete all as specified and as directed
M&L for painting of steel tubular trident/dwarf light pole of 2.5m to 5m long with two coats of synthetic enamel paint including numbering of pole No by stencils, cleaning the surface of pole by rubbing with emery paper to remove rust, dust, etc complete all as specified and as directed.
Supply and laying synthetic rubber insulated mats 2.0mm thick for voltage upto 11 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed.
S&F LED Indicator size 16mm, Red, Blue and Yellow colour suitable for LT feeder panel complete all as accessories complete all as specified and directed.
S&F cam operated rotary On/Off switch, 4 pole, 16 amp capacity suitable for LT feeder panel complete all as accessories complete all as specified and as directed.
Labour only for servicing, maintenance, checking and inspection complete including replacement of unserviceable parts of DG set comprising of (Engine/Alternator/Control Panel / AMF panel). Attending breakdown of DG Set complete i.e, Engine/Alternator/Control Panel / AMF etc for efficient functioning of under mentioned DG sets complete all as specified and directed. Note: (i) Spare parts and lubricant to be measured and paid separately under respective items here-in-after. (II) Labour charges for dismantling / taking down and replacement /refixing of new spare parts as when required as deemed to be included in unit rate quoted. (iii) Servicing to be carried out after every 250 Hrs run of DG Set.
320 KVA DG Set, MAKE : CUMMINS (MES No. NYA & Location : Main Power House at 5AFH)
320 KVA DG Set , MAKE : KIRLOSKAR (MES No.- 280/6106/DG/08, Location :- OT Sub-Stn at 5AFH)
100 KVA DG Set, . MAKE : KIRLOSKAR (MES No.- 280/6018-DG/AL/03 & Location :- Main Power House at 5AFH)
125 KVA DG Set , MAKE : KIRLOSKAR (MES No.- engine-280/6104/DG/06, alternator- 280/6105/AL/06, Location :- Surgical Sub-Stn at 5AFH & MES No.- engine-280/6126/DG/10, alternator-280/6127/AL/10, Location:- Mechanized Laundry at 5AFH)
250 KVA DG Set, MAKE : CUMMINS (MES No.- 280/6143/DG/13 & Location :- Surgical Sub-Stn at 5AFH & 250 KVA DG Set, MAKE : Greaves cotton.
200 KVA DG Set, MAKE : CUMMINS (MES No.- NYA & Location :- Surgical Sub-Stn at 5AFH
40 KVA DG Set, MAKE : KIRLOSKAR (MES No.- engine-3H.8509/1620183, alternator- DS351163P100530, & Location :- 11AFDC Sub-Stn at 5AFH
Supply only new spare parts confirming to the existing respective Cat parts Nos for DG set of 320 KVA capacity. Make - Cummins as under :-
Fuel filter Element inner with gasket and washer
Fuel filter Element outer with gasket and washer
Air Filter Element inner with gasket and washer
Air Filter Element outer with gasket and washer
Oil Filter Element inner with gasket and washer
Oil Filter Element outer with gasket and washer
Shell fuel filter, Cat No.- 251091
Fuel Water Separator, Cat No.- 3231787
Hose flexible, Cat No. - AK8052MS
Hose Plain, Cat No.- 3071160
Tube, water bypass, Cat No.- 213485
Tube fuel supply, Cat No.- 4085720
Belt, V- Ribbed - Cat No.- 3098359
Seal, O-Ring, Cat No. - 3330202
Sensor Temperature, Cat No.- 4954905
Coupling plain hose, Cat No.- 3069174
V-Belt, Cat part No.- 3040349
Supply only new spare parts confirming to the existing respective cat parts Nos for DG set of 320 KVA capacity. Make : Kirlosker as under :-
Fuel filter Element inner with gasket and washer, KV2.506.20.0.00
Fuel filter Element outer with gasket and washer
Air Filter Element inner with gasket and washer
Air Filter Element outer with gasket and washer
Oil Filter Element inner & outer with gasket and washer
Cartrige lub Oil Filter. KV0.043.03.0.02
Ring : Seal 24 x 29- KL6.041.06.0.00
Gasket Oil Pipe- KL6.043.13.0.00
Gasket Water Pipe- KL6.055.04.0.00
Hose Rubber Ring Joint- KL6.102.01.0.00
Clamp Hose Ring Type- KL6.102.01.0.00
Air cleaner Bracket for air cleaner- KL6.505.01.0.00
V-Belt, Type AX 58- KL6.140.11.0.00
Fuel pipe of existing size as specified
Supply only new spare parts confirming to the existing respective cat parts Nos for DG set of 100 KVA & 125 KVA capacity. Make : Kirloskar as under :-
Fuel filter Element inner with gasket and washer, 48117.10.0.00
Fuel filter Element outer with gasket and washer
Air Filter Element inner with gasket and washer, F6-50408.0.00
Air Filter Element outer with gasket and washer
Oil Filter Element inner with gasket and washer
Oil Filter Element outer with gasket and washer
Spin on filter -06.436.01.0.00
Fuel filter kit 1.1 ltr-48.999.20.0.00
Rubber hose -4H.168.030.00
V-Belt -4H.069.01.0.00
Hose thermostat to radiator
Supply only new spare parts confirming to the existing respective cat parts Nos for DG set of 250 KVA capacity Make : Cummins as under :-
Fuel filter Element inner with gasket and washer, 4962810
Fuel filter Element outer with gasket and washer
Air Filter Element inner with gasket and washer, F6-50408.0.00
Air Filter Element outer with gasket and washer
Oil Filter Element inner with gasket and washer, 3401544
Oil Filter Element outer with gasket and washer
Hose Pump. 3030762
Hose Plain. 215964
Belt V Ribbed. 3289235
Relay Assembly. 0307-3086
Calibration of fuel injection pump including minor repair and servicing of injector nozzles complete all as specified and directed.
Supply only new spare parts confirming to the existing respective cat parts Nos for DG set of 200 KVA & 250 KVA capacity, Make : Greaves Cotton as under :-
Fuel filter Element inner with gasket and washer, 4962810
Fuel filter Element outer with gasket and washer
Air Filter Element inner with gasket and washer, F6-50408.0.00
Air Filter Element outer with gasket and washer
Oil Filter Element inner with gasket and washer, 3401544
Oil Filter Element outer with gasket and washer
Sensor Temperature. 0193052902
V-Belt ribbed. 3289224
Element Lubricating Oil Filter. 3401544
Temperature thermostate.
Calibration of fuel injection pump including minor repair and servicing of injector nozzeles complete all as specified and directed.
Supply only new spare parts confirming to the existing respective cat parts Nos for DG set of 40 KVA capacity. Make - Kirloskar as under :-
L.O. filter element
Fuel filter element
Air filter element
Dismantling of radiator assembly from generating set and re-fixing the same after proper cleaning /repair with caustic soda and brazing the tube if any leakage is found complete all as specified and directed for following capacities of DG Sets:-
60/100 KVA DG Set. Make : Kirloskar
125 KVA DG Set, Mechanical Laundry. Make : Kirloskar
200 KVA DG Set, Surgical Sub Stn. Make : Cummins
250 KVA DG Set, Surgical Sub Stn. Make : Cummins
320 KVA DG Set, Main Power House. Make : Cummins
320 KVA DG Set, OT. Make : Kirloskar
Supply and filling of engine oil 20W/40 multi grade for top up / refilling of all DG set of various capacity, model & locations here-in-before as per the direction of engr-in-charge. Make: Gulf/Castrol/Servo/HP
Supply and pouring of anti corrosive / antifreeze coolant suitable for radiator of Kirloskar/Cummins make engine as per the requirement as directed by Engr-in-charge for various capacities of DG Set. Make: SERVO KOOL/CASTROL/PUROKOOL/K-KOOL
Supply and pouring distilled water / acid mixure for battary and radiator complete all as specified and directed.
Disconnecting the self starter (24V) from the engine body, dismantling the same, checking for identification of faulty spares and reassemblig the same after replacement / renewal of the following spares, if required, including refixing to its original position complete all as specified and directed. Note: Spares, required to be replaced, shall be measured and paid separately
Supply only following spares against the faulty ones for the self starter (24V) suitable for engine of 320 /250/200KVA Make : Kirloskar Engine.
Clutch assembly (Make : LUCAS TVS)
Bendex pinion (Make : LUCAS TVS)
Solenoid switch (Make : LUCAS TVS)
Carbon Brush (Make : LUCAS TVS)
Armature Field Coil (Make : LUCAS TVS)
Bush (Make : LUCAS TVS)
Self armature coil (Make : LUCAS TVS)
Disconnecting the self starter (12V) from the engine body, dismantling the same, checking for identification of faulty spares and reassemblig the same after replacement/renewal of the following spares, if required, including refixing to its original position all as specified and directed , Note :- spares, required to be replaced, shall be measured and paid under respective items mentioned here in under.
Supply only following spares against the faulty ones for the self starter(12V) suitable for engine of 100/125 KVA Make : Kirloskar Engine.
Clutch assembly (Make : LUCAS TVS)
Bendex pinion (Make : LUCAS TVS)
Solenoid switch (Make : LUCAS TVS)
Carbon Brush (Make : LUCAS TVS)
Armature Field Coil (Make : LUCAS TVS)
Bush (Make : LUCAS TVS)
Self armature coil (Make : LUCAS TVS)
Supply and fixing automatic voltage regulator (24 volt) of the following DG capacity including taking down old unserviceable one, complete all as specified and directed. Make : Stamford/Kirloskar/MRI/Crompton Greaves
24 Volt, Suitable for 320 KVA DG Set, 3 Phase,415 Volts
24 Volt, Suitable for 200/250 KVA DG Set, 3 Phase,415 Volts
Supply and fixing moulded case rectifier suitable for 125 KVA DG Set including taking down old unserviceable one complete all as specified and directed. Make :- Kirloskar / MRI / Johnson / Crompton Greaves or as existing make at site.
Supply and fixing Power contactor of following capacity including taking out old unserviceable one complete all as specified and directed.
500 Amps, 4 Pole with 2 NO & 2 NC and auxilary contact block of coil rating 415 Volt, 50 Hz. Make : L&T, Cat No. : CS97026; Type : MCX44 and/or equivelant model from make BCH/HAVELLS/Legrand/Siemens
315/325 Amps, 4 Pole with 2 NO & 2 NC, auxilary contact block of coil rating 415 Volt, 50 Hz, Make : L&T, Cat No : CS97023; Type : MCX41 and/or equivelant model from make BCH/HAVELLS/Legrand/Siemens
250 / 255 Amps, 4 Pole with 2 NO & 2 NC auxilary contacts of coil rating 415 Volt, 50 Hz. Make : L&T, Cat No.: CS97022; Type : MCX34 and/or equivelant model from make BCH/HAVELLS/Legrand/Siemens
100 Amps, 4 Pole with 2 NO & 2 NC auxilary contacts of coil rating 415 Volt, 50 Hz. Make : L&T, Cat No.: CS97017; Type : MCX12 and/or equivelant model from make BCH/HAVELLS/Legrand/Siemens
Supply and fixing current transformer tap wound, ring type rated burden 5 VA, for ammeter, of ratio 50/5, complete all as specified and directed. Make : Kappa/AE/L&T/Rishabh
S&F capacitor heavy duty contactor of upto 30 KVAR, 3 Pole with 1 NO & 1 NC of coil rating 415/440 Volt, 50/60 Hz, Including taking out old unserviceable one complete all as specified and directed. Make : Havells, Cat No. IHPAE030511(Type : CC53011)/L&T, Cat No.CS96148 or equivalent model from make BCH/T&C/ Legrand/Siemens.
S&F MCB TP 63 Amps of breaking capacity of 10 KA,'B' curve including taking out old unserviceable one complete all as specified and directed. Make : Havells, Cat No. DHMCCTPF063/L&T, Cat No.BB30630B or equivalent model from make Indo Asian/Legrand/Siemens
S&F 8 Step APFC Relay, 3 phase, 415V, 50 Hz including taking out old unserviceable one complete all as specified and directed. Make : Havells, Cat No. QHOTRB5N0012/L&T, Cat No. ETACONM008R or equivalent model from make BCH/Legrand/Siemens
S&F control relay with AC coil 10 Amps with 2 No and 2 NC contact arrangement, including taking down old unserviceable one complete all as specified and directed. Make : Havells, Cat No. IHACR22K or equivalent model from make L&T/ABB/BHEL/Siemens
S&F indicator lamp LED type, 220 volt AC (RED/GREEN) for each capacitor showing ON/OFF, including taking down old unserviceable one complete all as specefied and as directed. Make: L&T/RAAS/SIEMENS/LEGRAND
S&F push button actuator Red / Green and as approved including contact element, including taking down old unserviceable one, suitable as existing at site complete all as specefied and directed, complete with contact element (NO/NC). Make : L&T/RAAS/SIEMENS/HAVELLS
S&F OFF LOAD change over switch in sheet enclosure of current rating 400 Amps, 4 pole, 415 Volts including taking down old unserviceable one, complete all as specified and directed. Make : Havells/L&T/ABB/GE/LEGRAND/SIEMENS
S&F OFF LOAD change over switch in sheet enclosure of current rating 630 Amps, 4 pole, 415 Voltsincluding taking down old unserviceable one, complete all as specified and directed. Make : Havells/L&T/ABB/GE/LEGRAND/SIEMENS
S&F as in repairs battery,12 volt,180 AH of size XP 1800 complete all as specefied and directed. Make: Exide/Amaron/Amco
S&F in repairs battery,12 volt,150 AH,of size XP 1500, complete all as specefied and as directed. Make: Exide/Amaron/Amco
S&F in repairs battery charger, input voltage AC,single phase 230 volt, output voltage 24Volt, current rating 25 Amps, made for lead acid generator batteries upto 180 AH including battery lead copper with terminals for positive & negative not less than 2mtr long each and installing testing complete all as specefied and directed.
S&F as in repairs wiring harness for the following DG set complete all as specified and directed:-
320 KVA DG set
250 KVA DG set
125 KVA DG set
S&F as in repairs controller for the following DG set complete all as specified and directed:-
320 KVA DG set
250 KVA DG set
200 KVA DG set
S&F in repairs base card for the following DG set complete all as specified and directed:-
320 KVA DG set
250 KVA DG set
200 KVA DG set
S&F in repairs etectronic governor for the following DG set complete all as specified and directed:-
320 KVA DG set
250 KVA DG set
200 KVA DG set
M&L for Earthing complete with GI earth plate electrode of size 600x600x6mm thick buried directly in ground with earth pit not less than 2.25m deep below ground level with top edge of plate not less than 1.5m below normal ground level connected to GI earth strip of size 32 x 6mm earth lead by means of nuts, bolts, check nuts, washers of galvanized iron as steel, protected by galvanized iron pipe 40mm bore (medium grade) including cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 45x45x5cm thick reinforced with 8mm dia TMT bars @ 15cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20mm bore galvanized iron pipe (medium grade) for watering, charcoal or coke and salt in alternate layers including necessary excavation & earth work in soft/loose soil complete all as shown in Electrical Plate No 3 of SSR Part-I including testing on completion complete all complete as specified and directed after taking down old earthing NOTE : GI strip upto 7.5m including testing is deemed included in the item.
M&L for Earthing complete with copper earth plate electrode of size 600x600x3.15mm thick buried directly in ground with earth pit not less than 2.25m deep below ground level with top edge of plate not less than 1.5m below normal ground level connected to 20×3mm copper strip as earth lead by means of nuts, bolts, check nuts, washers of galvanized iron as steel, protected by galvanized iron pipe 40mm bore (Medium grade) including cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42x42x10cm thick reinforced with 8mm dia TMT bars @ 15cm c/c both ways with 10mm dia mild steel round bar of 30cm long, bent to shape as lifting handle, funnel, wire mesh, 20mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers including necessary excavation & earth work in soft/loose soil complete all as shown in Electrical Plate No. 3 of SSR Part-I including testing on completion all complete as specified and directed. NOTE : GI wire upto 7.5m including testing consider in this item. Note:- The contract sum shall be calculated by deducting the amount shown in schedule of credit attached to this tender, from total amount of Schedule 'A'/BOQ.
M/S BARUAH ELECTRICALS
Bidder Name
ANIL RAI AND COMPANY
M/S BARUAH ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .