| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-AOC RABINDRA NAGAR SILIGURI 734 006 | SILIGURI | DARJEELING | WEST BENGAL | 734006 | ₹6.0 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹6.0 LRejected-Finance NETAJI COLONY WARD NO 36 SILIGURI 734 006 | SILIGURI | DARJEELING | WEST BENGAL | 734006 | ₹6.0 L | L2 | Rejected-Finance Being L2 |
| 3 | L3₹6.1 LRejected-Finance EAST MILAN PALLY SILIGURI 734005 | SILIGURI | DARJEELING | WEST BENGAL | 734005 | ₹6.1 L | L3 | Rejected-Finance Being L3 |
Tender Value
₹6.0 L
EMD Value
₹12,036
Closing Date
19 Jan 2026, 12:00 pmClosed
EE/DED
Opposite of PWD Inspection Bungalow Kachari Road, Siliguri 734001, District Darjeeling
Electrical Installation and allied works for proposed LT Bulk service connection at the premises of Matigara Sericulture Complex, Matigara in the District of Darjeeling.
2025_WBPWD_981317_1
WBPWD/EE/DED/e-NIT-74 of 2025-26
Open Tender
ELECTRICAL WORKS ORG
28 days
SILIGURI
Please refer Tender documents.
4 documents required · 4 mandatory
₹12,036
11 May 2026
31 Dec 2025
21 Jan 2026
31 Dec 2025
19 Jan 2026
31 Dec 2025
SUB-HEAD 1-- SITC of LT Panels
SITC of floor mounting cubical compartmentalized 415 volt, 50 Hz dust & moisture proof for power distribution.The panel should have adequte strength & space fabricated with 14 SWG CRCA sheet with M.S angle iron frame (main frame with 50 x 50 x 6 mm angle and each vertical compartment with 40 x 40x6 mm MS angle iron). The base of panel should be made with 75mm x 40mm x 4.4 mm M.S. channel. [Manufacturer/Fabricator having Test Certificates from CPRI] to accommodate the incoming switchs bus bars with all interconnection in between switchs and busbars with solid cu rods /felxible wire for suitable capacity.
INCOMING- (i) a) 415 Volts, 315 A, TPN SFU with proper HRC fuse (open execution type) (Make: L&T/Legrand/Schenider/ABB/Siemens)- 1No.
BUSBAR- 415 V, 415 Amp capacity 99.9% – 99.5% electrolytic tinned 4 x 50x5mm bar copper bus bar mounted on non-hygroscopic porcelain insulator / hylam sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red, yellow, blue & black) for phases & neutral identification- 1 set.
OUTGOING- (i) 415V 200 Amps TPN SFU units with HRC fuses (Make:- L&T/SIEMENS/ABB/SCHNEIDER) in open execution. 1 no (ii) 415V 160 Amps TPN SFU units with HRC fuses (Make:- L&T/SIEMENS/ABB/ SCHNEIDER) in open execution.---- 3 Nos.
ACCESSORIES
B) 0-500V digital voltmeter-----------------------------1 set
C) LED indication lamp with fuse base &HRC fuse ---3nos
D) Danger Notice Board….01 No
SUB-HEAD 2 -- EARTHING INSTALLATION :-
Earthing with 50 mm dia GI pipe (TATA-Medium) 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc as required.
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size No. 8 SWG on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
Excavation of soil for installation of Earth Electrode and filling & ramming as to GS. (For soft soil) .
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
SUB-HEAD 3--Supplying & Laying of Cable
Supply of 2/4 Core XLPE Insulated & Sheathed Armoured stranded Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Polycab / RR /KEI/ Havells as approved by E.I.C]
4CORE 150 SQMM ( Meter to LT Panel)
4CORE 70 SQMM (from LT Panel to pole )
4 CORE 50 SQMM (From LT panel to Cold Storage Panel)
4 CORE 6 SQMM (From starter to pump)
2 CORE 16 SQMM (For compound light)
Laying of cable above 3½ core 90 sqmm and upto 3½ core 150 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting
Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting
Laying of cable above 3½ core 50 sqmm and upto 3½ core 90 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip)Wire, making holes etc. as necy. mending good damages andpainting
Laying of one No. cable above 35sqmm and upto 185 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings as per GS
32mm dia
50mm dia
65mm dia
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
4CORE 150 SQMM
4CORE 70 SQMM
4CORE 50 SQMM
4CORE 6 SQMM
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
4CORE 150 SQMM
4CORE 70 SQMM
4CORE 50 SQMM
4CORE 6 SQMM
SUB-HEAD 4-DISTRIBUTION WIRING OF PANEL ROOM
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (approved make) in 20mm size PVC rigid conduit 'FR' (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar with holes fixed on bakelite/hard rubber insulation over the welded chairs incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65 inspection box, making earthling attachment, painting the MS box and mending good the damages to original finish a) avg. run 8 mtr
LED Industrial Batten light (System lumen efficacy ≥110 lm/Watt) Supplying, installation, Testing & Commissioning of LED Industrial Batten light made of CRCA Sheet Body (Thickness ≥ 0.50 mm) and construction as per relevant IS, along with LED lamp (Opal finish polycarbonate housing with Aluminium end-cap), Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range 0o to 40o C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5%), life time (LED, Driver & electrical circuitary), of minimum 40000 Burning Hours, with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FR/FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 3 year OEM warranty. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Fixing arrangement shall be as below:
Fixing single/twin LED light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener, as below:
Single fittings along with S/F of 1 no. 18-20 W LED lamp as per specification
S & F of 240 V , 2+4way, 6-10A per way, double-door SPN MCB Distribution Boardwith with IP-42/43 protection with 40A DP MCB as incomer and 4 Nos. 6-10A SPMCBS ('C' curve, 10 kA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [Make:L&T/seimens/ ABB/ Havells]
Distribution wiring in 1.1 kV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required.
2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC (for 2x6A Board)
Supply & Fixing 240 V, 2 nos 6A, 5 pin Modular type plug socket with 2nos 6A modular type switch (Brand approved by EIC), without plug top, on 6 module GI Modular type switch board with top cover plate and makin gnecy.connections with PVC Cu wire and earth continuity wire etc.
Supplying, installation, Testing & Commissioning of 230V, 1-phase AC ceiling fans incl. all accssories, the capacitor of fan must be P-2 type brust proof & must have safety wire directly linked from fan hook to stator of fan, complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. [Make: Crompton/Usha/Havells/Orient]
Sweep Size- 1200 mm (48"), Wattage ≤ 55 Watt, R.PM ≤ 350, Air Delivery ≥ 220 C.M.M
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991)
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.
SUB-HEAD 5 --MISCELLANEOUS
LED Street Light fixture, powder coated pressure die cast aluminum body Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range 0o to 45o C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66, IK-As specified below, CRI >70, under voltage and over voltage protection, EMI- EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FR/FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90o C). System lumen efficacy shall be as below:
70 Watt System lumen efficacy ≥110 <135 lm/Watt (IK-8)
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive pain.
Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe(ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required andmending good damages to wall incl. painting etc
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Supply & Drawing 1.1 KV grade 3 Core 1.5 sqmm PVC/ XLPE insulated Cu Cable. [Make: HAVELES/ POLYCAB/ RR KABLE /Gloster/KEI] for connection from loop box to fittings through the Pole including making connections as necessary.
Supplying and fixing 415V, 315 A porcelain Kit Kat fuse for three phases and link for neutral. (Make: Seimens/L&T/Havells/ABB)[NS]
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.67 MB
WBF2911.pdf
Tender Documents • 0.50 MB
BOQ_2393148.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid