| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.7 LAccepted-Finance CHARHI HAZARIBAGH JHARKHAND 825336 | CHARHI | HAZARIBAGH | JHARKHAND | 825336 | L1 | Accepted-Finance The bid is techno-commercially suitable and acceptable. | |
| 2 | Rejected-Technical | - | Rejected-Technical In view of the L4 position, the bid is not considered acceptable commercially. | |
| 3 | Rejected-Technical 4TH FLOOR 417 VIPUL BUSINESS PARK ROAD NO 02 SECTOR 48 GURUGRAM HARYANA PIN 122018 | GURUGRAM | GURUGRAM | HARYANA | 122018 | - | Rejected-Technical In view of the L3 position, the bid is not considered acceptable commercially. | |
| 4 | Rejected-Technical EAR CSC CENTRE FAKODIH KUJJU BANJI MANDU RAMGARH JHARKHAND 825314 | RAMGARH | RAMGARH | JHARKHAND | 825314 | - | Rejected-Technical In view of the L6 position, the bid is not considered acceptable commercially. | |
| 5 | Rejected-Technical TEACHERS COLONY RANIBAG DIST RAMGARH JHARKHAND 829 122 | RAMGARH | RAMGARH | JHARKHAND | 829122 | - | Rejected-Technical In view of the L2 position, the bid is not considered acceptable commercially. |
| Sl No | Description | Qty | Unit | Maa Enterprises L1 | Nehru Electricals L5 | M/S SURENDRA PRASAD AND SONS L2 | M/s Construct Ability L3 | JAI MAHADEV ENTERPRISES L4 | M/S JAANVI SHARMA L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A | 224 | point | 605 ₹1,35,520 | 872 ₹1,95,328 | 600 ₹1,34,400 | 584.93 ₹1,31,024.32 | 275 ₹61,600 Lowest | 1,040 ₹2,32,960 |
| 2.00 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B | 172 | point | 732 ₹1,25,904 | 1,055 ₹1,81,460 | 650 ₹1,11,800 | 584.93 ₹1,00,607.96 | 230 ₹39,560 Lowest | 1,250 ₹2,15,000 |
| 3.00 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C | 78 | point | 906 ₹70,668 | 1,305 ₹1,01,790 | 675 ₹52,650 | 584.93 ₹45,624.54 | 230 ₹17,940 Lowest | 1,600 ₹1,24,800 |
| 4.00 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. | 32 | Nos. | 809 ₹25,888 | 1,166 ₹37,312 | 900 ₹28,800 | 1,041.19 ₹33,318.08 | 500 ₹16,000 Lowest | 1,400 ₹44,800 |
| 5.00 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 3 Module | 102 | Nos. | 73 ₹7,446 | 106 ₹10,812 | 100 ₹10,200 | 69.2 ₹7,058.4 Lowest | 150 ₹15,300 | 135 ₹13,770 |
| 6.00 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 6 Module | 32 | Nos. | 89 ₹2,848 Lowest | 129 ₹4,128 | 110 ₹3,520 | 94.3 ₹3,017.6 | 200 ₹6,400 | 160 ₹5,120 |
| 7.00 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 8 Module | 16 | Nos. | 104 ₹1,664 Lowest | 150 ₹2,400 | 140 ₹2,240 | 113.7 ₹1,819.2 | 200 ₹3,200 | 180 ₹2,880 |
| 8.00 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 12 Module | 32 | Nos. | 136 ₹4,352 Lowest | 196 ₹6,272 | 175 ₹5,600 | 158.21 ₹5,062.72 | 250 ₹8,000 | 230 ₹7,360 |
| 9.00 | providing and fixing 3 Module PVC surface box | 98 | Nos. | 71 ₹6,958 | 102 ₹9,996 | 60 ₹5,880 | 56.5 ₹5,537 Lowest | 200 ₹19,600 | 120 ₹11,760 |
| 10.00 | providing and fixing 6 Module PVC surface box | 30 | Nos. | 103 ₹3,090 | 149 ₹4,470 | 100 ₹3,000 | 72 ₹2,160 Lowest | 250 ₹7,500 | 180 ₹5,400 |
Tender Value
₹18.2 L
EMD Value
₹22,800
Closing Date
11 Aug 2026, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SO EnM
GM Office Charhi Hazaribagh Area
1. Fresh electrical modular wiring of executive hostel under GM unit Charhi Hazaribagh area 2. Fresh electrical modular wiring of newly constructed ICCC room under GM unit Charhi Hazaribagh area 3. Supply and laying of service wire from Pani Tanki to
2026_CCL_362595_1
GM(H)/EnM/Tender/26-27/09
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
GM Unit Charhi
Please refer Tender documents.
2 documents required · 2 mandatory
₹22,800
20 Nov 2026
27 Jul 2026
12 Aug 2026
28 Jul 2026
11 Aug 2026
28 Jul 2026
28 Jul 2026 - 3 Aug 2026
120 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A | 224 | point | - | - |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B | 172 | point | - | - |
| 3 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C | 78 | point | - | - |
| 4 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. | 32 | Nos. | - | - |
| 5 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 3 Module | 102 | Nos. | - | - |
| 6 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 6 Module | 32 | Nos. | - | - |
| 7 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 8 Module | 16 | Nos. | - | - |
| 8 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 12 Module | 32 | Nos. | - | - |
| 9 | providing and fixing 3 Module PVC surface box | 98 | Nos. | - | - |
| 10 | providing and fixing 6 Module PVC surface box | 30 | Nos. | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.31 MB
BOQ_375504.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .