| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹21.7 LAccepted-Finance | L-1 | Accepted-Finance qualified | |
| 2 | L-2₹22.1 L+₹36,795 (1.70%)Accepted-Finance | L-2 | Accepted-Finance qualified | |
| 3 | L-3₹23.6 L+₹1.9 L (8.95%)Accepted-Finance TEHSIL TRINTHA DISTRICT REASI 182311 JAMMU AND KASHMIR | REASI | JAMMU AND KASHMIR | 182311 | L-3 | Accepted-Finance qualified | |
| 4 | L-4₹23.8 L+₹2.1 L (9.68%)Accepted-Finance NH 1A DOMAIL UDHAMPUR BUILDERS INDIA NH 1A DOMAIL UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L-4 | Accepted-Finance qualified | |
| 5 | L-5₹26.3 L+₹4.6 L (21.4%)Accepted-Finance VILLAGE KARTHOLI NATIONAL HIGHWAY BARI BRAHAMANA JAMMU JAMMU KASHMIR 181133 | SAMBA | JAMMU AND KASHMIR | 181133 | L-5 | Accepted-Finance qualified |
Tender Value
Refer Docs
EMD Value
₹46,000
Closing Date
15 Jun 2021, 4:00 pmClosed
Executive Engineer
Electric Division JPDCL Udhampur
creation of 1 no 250kva sub station along with ht line
2021_PDD_123414_1
ED/UDH/02 of 2021-22, dt 22-05-2021
Open Tender
Electrical Works
Turn-key
90 days
district udhampur
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Executive Engineer Electric Division JPDCL
₹46,000
9 Jul 2021
24 May 2021
17 Jun 2021
24 May 2021
15 Jun 2021
24 May 2021
24 May 2021 - 29 May 2021
Survey, Supply, Transportation, carriage, erection, testing and commissioning for laying HT line for Govt. Polytechnic Udhampur at Chakhar with Tapping Points
9 mtr long ST Pole (ST-410SP33) for HT Line
GI V cross-arm with top Bracket including clamp
GI Channel X-arm including clamps and braces
GI Angle Braces (50X50X6) including clamps
0.03 ACSR Weasel conductor
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
11KV Pin Insulator (Polymeric) with Pins (12kv, 5KN) Creepage Distance 320mm
11KV Disc Insulators (Polymeric 45KN ) creepage distance 320 mm with tension fittings
Earthing complete by GI Rod 20 mm 2.5 mtr long through G.I Strip 25X3 mm in HT Lines
Painting of 9 mtr ST poles including crossarms/clamps with 1 coat of Red oxide Paint (Asian/Nerolac Make )
Painting of 9 mtr ST poles including crossarms/clamps with 2 coat of Aluminium Paint (Asian/Nerolac Make )
Cement bottoming 1:2:4 mix as per REC standards 0.45Cum/Pole
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
11 KV GO set, AB switch,3 phase,3 pole 200 Amps vertical type
Survey, Supply, Transportation, carriage, erection, testing and commissioning for creation of 1 no 250KVA for Govt. Polytechnic Udhampur at Chakhar
11/0.433kV, 3-phase 250KVA Distribution Transformers with Bimetallic Terminal Connectors Energy Level- 2, Copper wound for 250kVA rating and with LV Cable Box having detachable Aluminium Gland plate
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
300 mm² (2 ckt), 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
9 mtr. Long ST Pole (ST-410 SP33)
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
LT Distribution Box with MCCB for incomer & SFU's for Outgoing Circuits ( For 250 KVA Substation)
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Wedge Connectors / PG Clamps
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
3-Ø, 4-Wire Trivector Meter with CT
Cement bottoming 1:2:4 mix as per REC standards 0.45Cum/Pole
Painting of ST Poles 9mtr of substation including cross arm, clamps with1 coat of Red Oxide (Asian/Nerolac Make )
Painting of ST Poles 9 mtr of substation including cross arm, clamps with 2 coats of Aluminium Paint (Asian/Nerolac Make )
AJAY KAPOOR
M/S SURAJ PARTAP SINGH
M/S Builders India
HI-TECH TRANSFORMERS
vijay builders
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .