Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.6 LAdmitted-Fee/PreQual/Technical/Finance 5 32 PANNA LAL ROAD INDIAN PRESS CROSSING ALLAHABAD UTTAR PRADESH 211011 | PRAYAGRAJ | UTTAR PRADESH | 211011 | L1 | Admitted-Fee/PreQual/Technical/Finance | |
| 2 | L2₹8.8 L+₹21,234 (2.47%)Admitted-Fee/PreQual/Technical/Finance 249 LIG PREETAM NAGAR ALLAHABAD UTTAR PRADESH PIN 211011 | ALLAHABAD | ALLAHABAD | UTTAR PRADESH | 211011 | L2 | Admitted-Fee/PreQual/Technical/Finance | |
| 3 | L3₹8.9 L+₹26,773 (3.12%)Admitted-Fee/PreQual/Technical/Finance | L3 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | Sai Enterprises L2 | Allied Refrigeration and Electrical Works L1 | M/S RAJ ELECTRICALS L3 |
|---|---|---|---|---|---|---|
| 1.00Supply, Installation of VRF Air Conditioner in Signature Lab (ECED) | ||||||
| 1.01 | VRV Outdoor Unit - 10 HP
Model-RXMQ10
MAKE- Daikin/ Blue Star/ Voltas | 1 | Nos. | 2,99,696 ₹2,99,696 | 2,93,500 ₹2,93,500 Lowest | 3,00,298 ₹3,00,298 |
| 1.02 | Split type Indoor Unit-AQ32(1.06 Tr)
MAKE- Daikin/ Blue Star/ Voltas | 1 | Nos. | 39,719 ₹39,719 | 38,500 ₹38,500 Lowest | 40,922 ₹40,922 |
| 1.03 | Split type Indoor Unit-AQ50(1.65 Tr)
MAKE- Daikin/ Blue Star/ Voltas | 2 | Nos. | 95,084 ₹95,084 | 92,000 ₹92,000 Lowest | 96,288 ₹96,288 |
| 1.04 | Split type Indoor Unit-AQ63(2.06 Tr)
MAKE- Daikin/ Blue Star/ Voltas | 3 | Nos. | 1,73,679 ₹1,73,679 | 1,70,100 ₹1,70,100 Lowest | 1,75,125 ₹1,75,125 |
| 1.05 | Variable Refrigerant Volume System
Positioning, installation, testing of 6 indoor units, 1 nos. of outdoor units and fittings (Imported Y-joints & header etc.) remote controls of indoor units. | 1 | Lot | 72,818 ₹72,818 | 70,900 ₹70,900 Lowest | 73,059 ₹73,059 |
| 1.06 | Commission of VRV system including topping R410 A gas per site requirements. | 1 | Lot | 31,655 ₹31,655 | 31,000 ₹31,000 Lowest | 31,667 ₹31,667 |
| 1.07 | Refrigerant Piping
Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. | 1 | Lot | 1,09,528 ₹1,09,528 | 1,06,400 ₹1,06,400 Lowest | 1,10,129 ₹1,10,129 |
| 1.08 | Drain Piping
Providing and fixing rigid PVC piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation.
A)32 mm dia | 30 | Rm | 8,340 ₹8,340 | 8,160 ₹8,160 Lowest | 8,460 ₹8,460 |
| 1.09 | Control & Transmission
Wiring Providing & fixing control cum transmission wiring of 2 core x 1.5 sq mm copper in suitable conduits between indoor and outdoor unit. | 130 | Rm | 31,590 ₹31,590 | 30,810 ₹30,810 Lowest | 31,460 ₹31,460 |
Tender Value
Refer Docs
Closing Date
27 Aug 2026, 3:00 pmClosed
DIRECTOR
MNNIT Allahabad, Prayagraj-211004
Supply, Installation of VRF Air Conditioner in Signature Lab (ECED)
2026_MNNIT_922529_1
10/ESWM/2026-27
Limited
Electrical Works
Item Rate
60 days
Academic Campus MNNIT Allahabad
Please refer Tender documents
2 documents required · 2 mandatory
₹0
Exempted
28 Aug 2026
18 Aug 2026
28 Aug 2026
18 Aug 2026
27 Aug 2026
18 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply, Installation of VRF Air Conditioner in Signature Lab (ECED) | |||||
| 1.01 | VRV Outdoor Unit - 10 HP
Model-RXMQ10
MAKE- Daikin/ Blue Star/ Voltas | 1 | Nos. | - | - |
| 1.02 | Split type Indoor Unit-AQ32(1.06 Tr)
MAKE- Daikin/ Blue Star/ Voltas | 1 | Nos. | - | - |
| 1.03 | Split type Indoor Unit-AQ50(1.65 Tr)
MAKE- Daikin/ Blue Star/ Voltas | 2 | Nos. | - | - |
| 1.04 | Split type Indoor Unit-AQ63(2.06 Tr)
MAKE- Daikin/ Blue Star/ Voltas | 3 | Nos. | - | - |
| 1.05 | Variable Refrigerant Volume System
Positioning, installation, testing of 6 indoor units, 1 nos. of outdoor units and fittings (Imported Y-joints & header etc.) remote controls of indoor units. | 1 | Lot | - | - |
| 1.06 | Commission of VRV system including topping R410 A gas per site requirements. | 1 | Lot | - | - |
| 1.07 | Refrigerant Piping
Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. | 1 | Lot | - | - |
| 1.08 | Drain Piping
Providing and fixing rigid PVC piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation.
A)32 mm dia | 30 | Rm | - | - |
| 1.09 | Control & Transmission
Wiring Providing & fixing control cum transmission wiring of 2 core x 1.5 sq mm copper in suitable conduits between indoor and outdoor unit. | 130 | Rm | - | - |
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
TenderFormEN10.pdf
Tender Documents • 0.44 MB
BOQ_969435.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .