| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-AOC BASUDEBPUR BELKHALI HOWRAH PIN 711 322 | HOWRAH | HOWRAH | WEST BENGAL | 711322 | ₹6.0 L | L1 | Accepted-AOC AOC_Issued |
| 2 | L2₹6.9 LRejected-Finance 7 1B GRANT LANE KOLKATA 700012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | ₹6.9 L | L2 | Rejected-Finance that the bid is not L1 |
| 3 | L3₹7.0 LRejected-Finance 12 1 FERRIGHAT ROAD P O BHATPARA DIST NORTH 24 PGS WEST BENGAL PIN 743123 | BHATPARA | NORTH 24 PARGANAS | WEST BENGAL | 743123 | ₹7.0 L | L3 | Rejected-Finance that the bid is not L1 |
| Sl No | Description | Qty | Unit | Computer Gallery L1 | P R INFOSYS L2 | Creative Projects L3 |
|---|---|---|---|---|---|---|
| 1.00Supply, Installation,Testing & Commisioning of Microprocessor based (2 Loop) addressable fully networkable fire alarm control panel ( VDS / UL approved ) suitable for the devices as stated in the previous items of this BOQ along with 20% spare capacity with each loop loading not exceeding 80% of the full capacity of detectors and devices taken together, conplying to IS 2189:2008 or its latest amendments, and with minimum 600 character alpha - numeric liquid crystal display.The panel shall be soft addressable type and shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches with help monitor module whenever any alarm is triggered. The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards. The panel should have extra loop card slot for expansion of capcity twice. | ||||||
| 1.10The panel shall have in built rectifier, provision for external & internal printer ( if required ), Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, in built Surge protection facility, integral SMF lead acid batteries with sealed cells of 24 V capable of running for 24 hours normal working and then be capable of operating the system for 60 minutes during Emergency condition, with integral battery charger complete in all respect as required. | ||||||
| 1.20 | The FACP shall be capable of being networked ( future expansion ) with other similar FACP located at different part of the premises through single RS 485 modbus. The FACP shall have provision for interfacing with the public address system, remote computer and BMS interface.The system must be preloaded with licenced software.
(Approved Make : (Bosch/Siemens-/ Johnson Controls / Edward /Securiton/Honeywell) | 1 | Nos. | 2,50,000 ₹2.5 L | 2,50,000 ₹2.5 L | 2,50,000 ₹2.5 L |
| 2.00 | Supply, Installation,Testing & Commisioning of Micropresssor controlled IP Addressable multisensor detector IP 54 ( VDS / UL approved ) with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors.
(Approved Make : ( (Bosch/Siemens-/ Johnson Controls / Edward /Securiton/Honeywell) | 30 | Nos. | 2,500 ₹75,000 | 3,500 ₹1.1 L | 3,000 ₹90,000 |
| 3.00 | Supply, Installation,Testing & Commisioning of IP Addressable Manual Call Point ( VDS / UL approved ) with in built short circuit fault isolator as per NFPA style 7 wiring complete as required. (( (Bosch/Siemens/ Johnson Controls / Edward /Securiton/Honeywell) | 4 | Nos. | 4,000 ₹16,000 | 5,620 ₹22,480 | 5,000 ₹20,000 |
| 4.00 | Supply, Installation, Testing & Commissioning of IP Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator. Degree of protection IP65 ( VDS / UL approved) approved. (Approved Make: (Bosch/Siemens/ Johnson Controls / Edward /Securiton/Honeywell ) | 4 | Nos. | 8,000 ₹32,000 | 12,100 ₹48,400 | 9,000 ₹36,000 |
| 5.00 | Supply, Installation,Testing & Commisioning of Micropresssor controlled IP Addressable Heat detector IP 54 ( VDS / ULapproved ) with combination of fixed type & Rate of Rise of Temperature feature. Detector shall have maimum triggering temperature programmable from 60 deg. C to 80 deg. C., having high level of immunity to electromagnetic influances and show alarm signal limit temperature is reached. Detector shall have inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator.
(Approved Make : (Bosch/Siemens-/ Johnson Controls / Edward /Securiton/Honeywell ) | 4 | Nos. | 1,000 ₹4,000 | 3,400 ₹13,600 | 3,400 ₹13,600 |
| 6.00 | Supplying, installation, testing and commissioning of LED type Response Indicator ( VDS / UL approved) having 2 Nos. red coloured LED lamps including connections etc. (Approved Make : ( (Bosch/Siemens/ Johnson Controls / Edward /Securiton/Honeywell ) | 10 | Nos. | 90 ₹900 | 120 ₹1,200 | 120 ₹1,200 |
| 7.00 | Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex/RR Kable/Polycab ) through 19 mm dia PVC 'FR' type Rigid Conduit pipe with necessary arrangement as per G.S. (Make : Precision/ AKG/ Universal/ Polycab) on the surface of the wall. | 400 | Mtrs. | 90 ₹36,000 | 100 ₹40,000 | 120 ₹48,000 |
| 8.00 | Checking & Testing of necessary cable and conduiting work for installed at CCU 3rd Floor G bldg. campus of ID & BG Hospital, Kolkata, as per latest Fire alarm guide line (IS2189/NBC/NFPA72). | 1 | Job. | 20,000 ₹20,000 | 16,700 ₹16,700 | 20,000 ₹20,000 |
Tender Value
₹6 L
EMD Value
₹12,000
Closing Date
13 Mar 2025, 1:00 pmClosed
EEI,KNHED, PW Dte
THE EXECUTIVE ENGINEER, P.W.D /KOLKATA NORTH HEALTH ELECTRICAL DIVISION
Supply, installation, testing and commissioning of conventional Fire Detection Alarm system at CCU 3rd floor G bldg. campus of ID and BG hospital, Kolkata.
2025_WBPWD_821132_1
WBPWD/EE/KNHED/e-NIQ-143/2nd Call/24-25
Open Tender
ELECTRICAL WORKS ORG
45 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹12,000
Office of The EE, KNHED, PW Dte
20 Apr 2026
27 Feb 2025
17 Mar 2025
27 Feb 2025
13 Mar 2025
7 Mar 2025
6 Mar 2025
Amount
Supply, Installation,Testing & Commisioning of Microprocessor based (2 Loop) addressable fully networkable fire alarm control panel ( VDS / UL approved ) suitable for the devices as stated in the previous items of this BOQ along with 20% spare capacity with each loop loading not exceeding 80% of the full capacity of detectors and devices taken together, conplying to IS 2189:2008 or its latest amendments, and with minimum 600 character alpha - numeric liquid crystal display.The panel shall be soft addressable type and shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches with help monitor module whenever any alarm is triggered. The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards. The panel should have extra loop card slot for expansion of capcity twice.
The panel shall have in built rectifier, provision for external & internal printer ( if required ), Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, in built Surge protection facility, integral SMF lead acid batteries with sealed cells of 24 V capable of running for 24 hours normal working and then be capable of operating the system for 60 minutes during Emergency condition, with integral battery charger complete in all respect as required.
The FACP shall be capable of being networked ( future expansion ) with other similar FACP located at different part of the premises through single RS 485 modbus. The FACP shall have provision for interfacing with the public address system, remote computer and BMS interface.The system must be preloaded with licenced software. (Approved Make : (Bosch/Siemens-/ Johnson Controls / Edward /Securiton/Honeywell)
Supply, Installation,Testing & Commisioning of Micropresssor controlled IP Addressable multisensor detector IP 54 ( VDS / UL approved ) with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors. (Approved Make : ( (Bosch/Siemens-/ Johnson Controls / Edward /Securiton/Honeywell)
Supply, Installation,Testing & Commisioning of IP Addressable Manual Call Point ( VDS / UL approved ) with in built short circuit fault isolator as per NFPA style 7 wiring complete as required. (( (Bosch/Siemens/ Johnson Controls / Edward /Securiton/Honeywell)
Supply, Installation, Testing & Commissioning of IP Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator. Degree of protection IP65 ( VDS / UL approved) approved. (Approved Make: (Bosch/Siemens/ Johnson Controls / Edward /Securiton/Honeywell )
Supply, Installation,Testing & Commisioning of Micropresssor controlled IP Addressable Heat detector IP 54 ( VDS / ULapproved ) with combination of fixed type & Rate of Rise of Temperature feature. Detector shall have maimum triggering temperature programmable from 60 deg. C to 80 deg. C., having high level of immunity to electromagnetic influances and show alarm signal limit temperature is reached. Detector shall have inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. (Approved Make : (Bosch/Siemens-/ Johnson Controls / Edward /Securiton/Honeywell )
Supplying, installation, testing and commissioning of LED type Response Indicator ( VDS / UL approved) having 2 Nos. red coloured LED lamps including connections etc. (Approved Make : ( (Bosch/Siemens/ Johnson Controls / Edward /Securiton/Honeywell )
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex/RR Kable/Polycab ) through 19 mm dia PVC 'FR' type Rigid Conduit pipe with necessary arrangement as per G.S. (Make : Precision/ AKG/ Universal/ Polycab) on the surface of the wall.
Checking & Testing of necessary cable and conduiting work for installed at CCU 3rd Floor G bldg. campus of ID & BG Hospital, Kolkata, as per latest Fire alarm guide line (IS2189/NBC/NFPA72).
Dismantling existing FDA sytem Panel, Detector, MCP & Hooter and shifting to sectional store.
Supply, Installation,Testing & Commisioning of Micropresssor controlled IP Addressable multisensor detector Complete with Mounting Base IP 54 ( VDS / UL approved ) with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors. Make :Siemens/ Approved by EIC ( for the existing system)
NOTE :- 1) The Fire Alarm system shall comply with latest requirements of -- (i) National Fire Protection Association (NFPA) Standards, (ii) IS 2189 , (iii) NFPA 70 National Electric Code, (iv) NFPA 72 National Fire Alarm & Signaling Code , (v) Local Statutory Regulations , (vi) Manufacturer Recommendation. vii) System should be integrated with the components like FACP, Detectors, MCP, Hooter, Monitor Module, Relay Module, etc. and all these components should be of same brand.
(Rate should be quotated all taxes and duties, GST)
P R INFOSYS (BID ID -6226070)
Creative Projects (BID ID -6226554)
stage.html
html • 0.05 MB
technical_1826705.pdf
techsummary_1826705.pdf
finance_1826705.pdf
BOQ Comparative Chart
xlsx
finsummary_1826705.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.58 MB
BOQ_1826705.xls
BOQ • 3.12 MB
2911.pdf
Tender Documents • 0.50 MB
suspension.pdf
Additional Documents • 2.91 MB
Download all tender documents and submit your bid