Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.0 LAccepted-AOC | L1 | Accepted-AOC Lowest Tenderer | |
| 2 | L2₹34.6 L+₹39,221 (1.15%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L2 | Rejected-Finance GREATER THAN L1 | |
| 3 | L3₹35.0 L+₹81,387 (2.38%)Rejected-Finance | L3 | Rejected-Finance GREATER THAN L1 | |
| 4 | L4₹37.0 L+₹2.9 L (8.41%)Rejected-Finance SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L4 | Rejected-Finance GREATER THAN L1 | |
| 5 | L5₹38.6 L+₹4.5 L (13.1%)Rejected-Finance FLAT NO 401 TULSANI HEIGHTS 4TH FLOOR GREEN PARK SOCIETY AKURDI GURUDWARA TO WALHEKAR WADI ROAD CHINCHWAD PUNE 411033 | PUNE | MAHARASHTRA | 411033 | L5 | Rejected-Finance GREATER THAN L1 |
Tender Value
₹45.5 L
EMD Value
₹91,000
Closing Date
14 Jun 2023, 6:55 pmClosed
P Bangar Raju,IDSE
GE (I) (NAVY), INS SHIVAJI - POST, LONAVLA -410402
SPL REPAIRS/ REPLACEMENT OF ELECTRICAL WIRING AND ASSOCIATED FITTING AT CERTAIN OTM BLDG, SPL REPAIRS / REPLACEMENT OF OLD HIGH BAY LIGHTS AND FIXTURES AT BLDG NO P-149 AND SPL REPAIR TO BER TO EXHAUST FAN AND AIR CIRCULATOR AT INS SHIVAJI LONAVLA
2023_MES_596568_1
GE/LONAVLA/8141/E8
Open Tender
Civil Works
Item Rate
180 days
GE (I) (NAVY) LONAVLA
As per NIT /Tender documents
6 documents required · 6 mandatory
₹500
Yes
GE (I) (N) Lonavla
₹91,000
Yes
12 Oct 2023
18 May 2023
16 Jun 2023
18 May 2023
14 Jun 2023
1 Jun 2023
18 May 2023 - 31 May 2023
Amount
Taking down carefully unserviceable aluminium/copper point wiring (light, fan, socket or power) including unserviceable light fittings, switch board complete, switch sockets, ceiling roses, pendants, regulators, sockets, etc and removing materials from site and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
M & L for Point wiring with 1.5 Sqmm (nominal area), FRLS PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including providing PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FRLS PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including PVC terminal box fixed with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and directed. One light point or one fan point or bell point controlled by one switch
One 3 pin socket outlet, 5 Amp independent
One 3 pin socket outlet, 5 Amp on the same board with other switches
All as per item No.4 here in before but wiring with cables of size 2.5 sqmm for wiring & cables of size 2.5 sqmm both (FRLS) as continuous earth wire for one 15 Amps, 3 pin Switch/Socket outlet on Independent board complete all as specified and directed. (Note : cutting chases & making good of disturbed surfaces shall be measured and paid separately).
S & F switch piano, 5 Amp, single pole, flush type one way 230 volts complete all as specified and as directed.
S & F socket out let, 2 in 1, 3 pin, 5 Amps, 240 volts complete all as specified and directed.
S & F Switch socket combination, 2 in 1, 5 Amps, flush type, 240 volts complete all as specified and directed.
S & F Switch socket combination, 5 in 1, 5/15 Amps, 240 volts, flush type complete all as specified and directed.
S & F Ceiling rose, 3 way PVC insulated body complete all as specified and directed by engineer in charge.
Labour only for taking down and fixing repairs to Ceiling Fan with Fan regulator, any Make & any Sweep Oiling, Greasing , removing all dust with painting and Rewinding of fan by super ennameled copper insulated wire as per existing gauge, varnishing, heating assembling and testing for serviceable condition complete all as directed by Engineer-in-Charge.
Supply & fix fans ceiling complete with accessories 230 V,1200 mm sweep. BEE 5 star rated complete all as specified and as directed.
Supply & fix exhaust fans metal body complete with and accessories 230 V,300 mm sweep including taking down old u/s exhaust fan and deposited to MES store complete all as specified and as directed. Make : Havells
Supply and fixing Batten 1x18W(single side supply)for LED TUBE LIGHT pre -coated CRCAA sheett, end caps made up with engineering plastic all as specified and directed.Make : Bajaj (BLRB - DB 118) or equivlent PhilipsHavells.
Supply and fixing ROD 1x18W (single side supply)for LED TUBE LIGHT T8 tube with polycarbonate body all as specified and directed.Make : Bajaj (BLRB - 20W LED) or equivlent PhilipsHavells.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. Make: Crompton or equivlent Bajaj/Philips/Havells
Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.Make: Crompton or equivlent Bajaj/Philips/Havells
Taking down of Old MCB DB / control box any type any size including MCBs and separating the serviceable MCB DBs and MCBs for reuse at site
S&F in replacement Triple pole and neutral (8 Way) Double door, (VTPN) suitable for and including MCCB 4 pole, 160 amps, 16 KA as incoming (compact) Earth and neutral bus bar of capacity upto 200 amp 8 ways,IP 43 protection , shrouded neutral bar & pan assembly with flexible connecting link in the wall with suitable nut and bolt including matching the existing surface all as specified and directed , Make Havells (DHDLVDOBGSFE08)HSN CODE 8537 or equivalent indoasian/Standered.
S&F in replacemen MCB DB SPN 12 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface all as specified and directed
S&F in replacemen MCB DB SPN 8 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface all as specified and directed
S&F in repairs MCB SPN 40 to 63 AMP, 240 Volts 10KA ''C''&''B'' curve , as per site requirment,Complete all as specified and directed.
S&F in repairs MCB SP 5 To 32 AMP, single pole 240 Volts 10KA ''C''&''B'' curve , as per site requirment,Complete all as specified and directed.
S&F in repairs MCB SP 32 to 63 ,single pole 240 Volts 10KA ''C''&''B'' curve , as per site requirment,Complete all as specified and directed.
Taking down sub main wiring of any size from the ceiling, walls etc and incl making good to disturb surface of wall and match with the existing surface.
M&L for sub main wiring drawing through PVC casing and capping with two single core 4 sq mm and one run of 4 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts grade all as directed. Note:- Three run of 4 sqmm wire and One run of PVC casing caping will be measured as one running meter.
M&L for sub main wiring drawing through PVC casing and capping with four runs of single core 10 sq mm and two runs of 10.0 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts grade all as directed.Note:- four run of 10 sqmm wire and One run of 10 sqmm earth wire and One run of PVC casing caping will be measured as one running meter.
Taking down electric meter of any type and any make single/three phase by dismantling of all electrical connection checked the meter ,and refixed same Nos of meter on wooden board of suitable size in same Nos of qtr after repair works completed
M&L for earthling complete with galvanized GI earth plate electrode of size 600x600x6.00 mm, buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4.0 mm dia by means of volts, nuts, check nut and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate as shown in electrical plate No 3 of SSR part1991,20 mm dia watering pipe medium grade 1.50 mtr long GI protection pipe light grade 15 mm dia from earth pit to main board (NOTE:- maximum length of GI protection pipe with each earth shall not be less than 7.5 mtrs) including necessary pit with cover , including testing on complition.
Supply ,laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core complete all as specified and as directed.
Excavation in trenches n. exc. 1.5 M in width and 1.5 M in deep for laying of pipes and getting out in Soft / loose Soil complete as specified & directed
Cutting bituminus road as per direction of Engr in Charge for laying of UG cable and match the existing road to the existing system.
Returning, filling including spreading, leveling, watering and well ramming in layers not exc 25cm in soft/soil complete all as specified and directed
Removing excavated material n. exc. 50 M away and depositing where directed at a level n. exc. 1.5 M above the starting point complete all as specified and as directed.
M&L Sand cushioning for UG cable protection/ducts, consolidated sand compacted with clean dry sand all as directed and specified.
Supplying laying, brick sub class 'B' common burnt laid in trenches for cable protection complete all specified and directed.
Supply and lay in trenches / along the wall / floor pipes GI light grade of size 50 mm dia with and including all fittings and accessories including taking down old U/S pipe complete all as specified and and directed for cable protection
Supply and fixing energy saving, envroment friendly & robust mediumby/Hiighbay LED luminaire with high efficacy (100 im/W) with toughened glass. Make : havells cat no- GAZELLAHBP100WLED857PBOTG or equivlent Philips/Bajaj. Note: All Highbay light hanging with truss ,all wiring done in casing caping or in condute as per site required,additional accesories price including in this rate.
Supply and fixing Higher wattage flood light luminaire with ultra sleek, light weight and secondary optics,made of pressure die cast housings with IP66 ingress protection and impact resistance of IK07.4kv inbult and 10kv external surge protection .Make : Bajaj (BJFL 150W LED I ) or equivalent philips/Havells.
Supply and fixing Higher wattage warm white flood light luminaire with ultra sleek, light weight and secondary optics,made of pressure die cast housings with IP66 ingress protection and impact resistance of IK07.4kv inbult and 10kv external surge protection .Make : Bajaj (BJFL 150WW LED I ) or equivalent philips/Havells...
Supply & fix Air Circulator fans 230 volts single phase oscillating upto 450 mm sweep suitable for wall mounting complete all as specified and as directed.
Repair and refixing Air Circulator fans 230 volts single phase oscillating upto 450 mm sweep suitable for wall mounting complete all as specified and as directed.
S&F in replacement MCB DB TPN 4 ways double door with 440 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface all as specified and directed
S&F in repairs MCB 415V 10KA 'C' Curve TPN 40 To 100 AMP , complete all as specified and directed.
Supply and fix in repairs Triple pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of rating upto 32 Apms
S&F in replacement Triple pole and neutral (6 Way) Double door, (VTPN) suitable for and including MCCB 4 pole, 250 amps, 16 KA as incoming (compact) Earth and neutral bus bar of capacity upto 200 amp 8 ways,IP 43 protection , shrouded neutral bar & pan assembly with flexible connecting link in the wall with suitable nut and bolt including matching the existing surface all as specified and directed , Make Havells (DHDLVDOBGSFE08)HSN CODE 8537 or equivalent indoasian/Standered.
M&L for sub main wiring drawing through PVC casing and capping with four runs of single core 6 sq mm and two runs of 6.0 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts grade all as directed.Note:- Four run of 6 sqmm wire and Two run of 6 sqmm wire and One run of PVC casing caping will be measured as one running meter.
M&L for concelled point wiring in stove enamelled steel conduits exclusive of boxes (Junction /terminal ) but incusive of all tees , bends elbow , reducer bell mouth tube and fixing all accessories such as couplers , lock nut , saddle , pipe hooks etc ( from meter box on each floor to DB in individual dwelling unit with PVC FRLS multi strandard copper conductor unsheathed cable of size 2.5 sqmm by using PVC FRLS copper conductor unsheathed cable of size 1.5 sqmm(for earthing connections to common earth dolly/earth lugs in MS sunken box/switch board) drawning in concelled conduits 20/25mm dia with all arrangements & PVC accessories as required to site requirement inlcuding fixing of switch board with new machine brass screw & washers complete all as specified & directed. Note :- 1. Colour code of Phase cable is Red,Yellow and Blue . (2) colour code of Neutral is BLACK. (3) Colour code of Earth wire is GREEN.
Supply and fixing LED light fitting 1x40 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
Supply and fixing Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V
Supply ,laying and testing cable XLPE insulated,screened,PVC bedded,galvanized steel strip or wire armoured,electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core complete all as specified and as directed.
S & F Exhaust fans AC single phase 230/ 240 V of size 450 mm sweep with blades, and frame , louver steel body all as specified and directed by Engineer-in-charge. Make : Havells - Turbo Force Heavy duty or Bajaj/crompton.
S & F Exhaust fans AC single phase 230/ 240 V of size 300mm sweep with blades, and frame , louver steel body all as specified and directed by Engineer-in-charge. Make : Havells - Turbo Force Heavy duty or Bajaj/crompton.
S & F Exhaust fans AC single phase 230/ 240 V of size 225/230mm sweep with blades, and frame , louver steel body all as specified and directed by Engineer-in-charge. Make : Bajaj - Heavy duty or Havells/crompton.
S & F Wall Air circultor fan AC single phase 230/ 240 V of size 600 mm sweep with blades, and frame , steel body complete with all accessories all as specified and directed by Engineer-in charge. Make : Havells - Turbo force heavy deuty or Bajaj/Crompton.
Shree Ayyappa Engineering
Suchit constructions
cooltech engineering services
SHAILENDRA B TULSANI
M/s S.D Construction Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .