| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.5 LAccepted-AOC 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹15.6 L+₹3.1 L (24.7%)Rejected-Finance 28 SAMBHU BABU LANE KOLKATA 700014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L2 | Rejected-Finance 2nd lowest bidder | |
| 3 | L3₹15.8 L+₹3.3 L (26.1%)Rejected-Finance 31 1 6 SEBADAL ROAD UDAYPUR NIMTA KOLKATA 49 | 24 PARAGANAS NORTH | WEST BENGAL | 700049 | L3 | Rejected-Finance 3rd lowest bidder | |
| 4 | L4₹16.6 L+₹4.1 L (32.6%)Rejected-Finance VILL P O NARIT P S AMTA DIST HOWRAH PIN 711413 | HOWRAH | WEST BENGAL | 711413 | L4 | Rejected-Finance 4th lowest bidder |
Tender Value
Refer Docs
EMD Value
₹28,000
Closing Date
18 Sept 2024, 12:00 pmClosed
EE_I, Kol. South Health El. Divn.,P.W.Dte.
75 D H Road Kidderpore Kol_23
EI work for partitioning of different Doctors Sisters Staff duty rooms, rest rooms, wash rooms, drinking water points incl Air Conditioning at dift bldgs and improvement of compound illumination level for stregthening of Security in the premises.....
2024_WBPWD_741912_1
WBPWD/EE-I/KSHED/Q44/24-25
Open Tender
A/C ORG
Item Rate
60 days
Kolkata
Please refer Tender documents.
3 documents required · 3 mandatory
₹28,000
O/o Exe. Engr., Kol. South Health El. Divn., PWDte
4 Apr 2025
30 Aug 2024
20 Sept 2024
30 Aug 2024
18 Sept 2024
6 Sept 2024
5 Sept 2024
Amount
S&D of minimum 1.5 Tr Capacity ceiling suspended [concealed] Split Air Conditioner with R410A / R407C / R-32 Refrigerant, with Rotary / Twin Rotary Compressor with minimum Cooling Capacity not less than 5.4 KW, Air Flow not less than 560 CFM, Moisture Removal should be 1.6 I/hr, EER not less than 2.8 KW/KW, Minimum cu. pipe Length from ODU to IDU not less than 20 MTR & suitable for operation on 230V,+_ 5% , 50Hz, 1Ph AC Supply. with precharged refrigerant, Wired/ Wireless remote & all other accessories complete with refrigerent gas and other necy. items. as per direction by EIC (Make : Mitsubishi heavy industries / O General / Daikin ).
Installation, testing & Commissioning 1.5 Tr Concealed Split type AC Machine with all accessories i.e., fastner, nut bolt, wall cutting, all glass window/grill cutting where needed with S&F heavy gauge ODU iron brecket, IDU tie rod, MS C Channel etc. incl. mending good damages as per direction of EIC.
Supply & fixing of HVAC grade copper pipe with minimum thickness 9 mm Nitril Rubber insulation of following sizes for liquid and gas line between ODU and IDU (Make - Ryoku/Nippon):-
(a) 5/8" (gas line).
(b) 1/4" (liquid line).
Supply & Laying of following PVC insulated Copper Cable ("FRLSH") on wall incl. making connections as per direction of EIC.(As Control Cable from ODU to IDU ) ( Make : KEI/ Finolex/ Pollycab/Gloster)
(a) 3 core 2.5 sqmm
(b) 3 core 1.5 sqmm
Supply, design, fabrication, installation of MS structural work for supports IDU/ODU both where needed i.e., 25x6 mm MS flat bar/ 50x50x6 mm MS Angle/ 50x6 MS C channel/ 25x25x6 mm MS Angle etc with 2 coat painting (Approved by EIC) and vibration pad, stainless steel (SS-304) nut bolts as per site requirement.incl scraffolding and carring charges .(ODU/IDU Support) (As per direction of E.I.C)
Supply & Fixing of perforated GI cable tray for covering of regfrigerent pipe line of Split/Concealed type AC Machine incl. S&F GI connector, 6 mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. (As per direction of E.I.C)
150x50x1.25mm (18SWG)
Supply & laying PVC Drain Pipe (25mm dia) for drainage water including all accessories i.e., elbow, socket, tee, saddeling etc. as per direction by EIC. (make - Oriplast/Supreme)
TERMS & CONDITIONS :- The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/ submission of bill. If any refurbished material is supplied and installed, penal action will be taken as per existing rules
Defect Liabibility Period 1 (One) year
Make & model of each and every material to be approved by EIC
M/s Singh Electrical Works (BID ID -5587789)
FAME ENGINEERING (BID ID -5591643)
ELEGANT POWER (BID ID -5589955)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .