EE/Elect./Auto/EM/CLZ
EE/Elect./Auto/EM/CLZ
Repair of HT Panels / lines and allied accessories along with Maintenance during monsoon season 2026 for various pumping station under Civil line Zone.
2026_MCD_277946_1
EE E/EnM/A/CLZ/TC/2026-27/06.6
Open Tender
Electrical Works
30 days
EE/Elect./Auto/EM/CLZ
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
₹12,500
12 Jun 2026
19 May 2026
22 May 2026
19 May 2026
22 May 2026
19 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.001 | Servicing of 11 KVA HT Panel Ve VCIB Trolly is pulled out mechanically and after servicing/ cleaning same is inserted back to panel including bushing, moving contact and operating mech etc, as required | 4 | Each | 7,961 | ₹31,844 |
| 2.001 | Servicing of VCB cleaning of Inner male and female contact with CRC, repairing of operating mech. for smooth operation of VCB after rectification of wring etc. at required. | 8 | Job | 15,310 | ₹1,22,480 |
| 3.001 | Dismantling of aluminium bus bar suitable for 800 Amp. & 400 Amp. Load of the main panel and re-fixing the same after tapping with heat shrinkable | 4 | Job | 7,961 | ₹31,844 |
| 4.001 | Providing and fixing 2.4/30V, DC relay for tripping system 1 incoming & 2 outgoing. The job indules disconnection of relay from the panel, calibration and testing with primary Injection test. The job includes the replacemerit of defective wiring as required at site. (Over current and earth fault realy) | 2 | Job | 14,160 | ₹28,320 |
| 5.001 | Providing and fixing of Indicating lamp unit with holder. | 6 | Each | 354 | ₹2,124 |
| 6.001 | Testing of PT and replacement of HT funes funes-3 nos | 2 | Job | 8,260 | ₹16,520 |
| 7.001 | Providing and fixing of power pack of rating AC 220/110 Input, output 24/30 VDC for providing the supply to the tripping system | 2 | Job | 5,900 | ₹11,800 |
| 8.001 | Providing and fixing of TNC (Trip Neutral control) Switch | 2 | Job | 2,478 | ₹4,956 |
| 9.001 | Providing and fixing of space heater with thermostat including controlling switch to maintaining the panel moisture free | 2 | Job | 2,950 | ₹5,900 |
| 10.001 | Providing and fixing of HT CT epoxy moulding heavy duty as per sample | 2 | No. | 17,882 | ₹35,764 |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
Eligibility_Criteria.pdf
Tender Documents • 0.43 MB
MCD_GCC_2025Updated2026.pdf
Tender Documents • 16.45 MB
BOQ_324562.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid