| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.2 LAccepted-AOC | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹17.9 L+₹2.7 L (17.8%)Rejected-AOC DAYA BAGH SATTANI DHAR ROAD UDHAMPUR DISTT UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-AOC OK | |
| 3 | L3₹20.6 L+₹5.4 L (35.4%)Rejected-AOC WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-AOC OK |
Tender Value
₹32.1 L
EMD Value
₹64,180
Closing Date
15 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Army Dhar Road
GE Army Dhar Road
REPAIR AND MAINT OF INTERNAL ELECTRIC SUPPLY NETWORK FANS GEYSERS ETC AND OTHER CONNECTED WORK ETC AT OTM/MD ACCN OF VARIOUS UNIT AT JINDRAH UNDER GE ARMY DHAR ROAD
2024_MES_659146_1
8070/NIT-46/2024-25
Open Tender
Civil Works
Item Rate
270 days
GE Army Dhar Road
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE Army Dhar Road
₹64,180
Yes
24 Sept 2024
11 Jun 2024
17 Jul 2024
12 Jun 2024
15 Jul 2024
26 Jun 2024
Amount
Taking down old unserviceable/deteriorated batten/PVC conduit point wiring aluminium/ copper from existing place i.e. light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets,bell push , ceiling rose, pendants, Holders, etc and making good all disturbed surface to wall, floor etc by means of cement mortar (1 : 3) or plaster of Paris and to match / finish new surface as the existing surface either by using same colour distemper, Putti or white / colour wash all as required and directed by Engineer-in-Charge.
Material and labour for Point wiring complete (for simple and modular type ) with 1.5 sqmm single core PVC insulated heavy duty ISI Marked,FRLS unsheathed cable 1100 volts grade with multistranded copper conductor drawn through subsist non metalic PVC conduit heavy duty not less than 20mm dia with all accessories like tee, straight joint, L Bend etc.,concealed on walls, sufrace on ceiling/ floors etc., and including provision of PVC heavy duty Insulated FRLS copper conductor, 1.5 sqmm for earth continuity conductor and connected to common earth dolly, including suitable size of sheet metal modular sunken box 1.2mm thick fixed and flushed inside the walls, with 3mm thick laminated sheet top cover/modular cover plate for housing the switches, socket outlets, fan regulators etc., for the following:-
One light /Fan/Bell point controlled by one switch 6/5 Amp one way single pole.
One light point controlled by one switch 6/5 Amp two way switch.
One 3 pin socket outlet 6/5 Amps controlled by one switch on the same board with other switches.
One 3 pin 6/5 Amp socket outlet controlled by one switch independent board.
All as per item No 2 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
S&F switch piano flush type (ISI marked), single pole, one way 6 Amp, 240 Volts complete all as specified and as directed.
S&F switch piano flush type (ISI marked), single pole, Two way 6 Amp, 240 Volts complete all as specified and as directed.
S&F switch piano flush type (ISI marked), single pole, one way 16/15 Amps, 240 Volts including complete all as specified and as directed.
S&F socket outlet 3 pin, 6 Amp piano flush type including complete all as specified and as directed.
S&F socket outlet, 2 in 1, 3/5 pin 6 / 16 Amp, piano flush type complete all as specified and as directed.
S&F Switch socket combination outlet 3 pin, 5 Amp piano flush type including taking down complete all as specified and as directed.
S&F Switch socket combination outlet, 2 in 1, 3/5 pin 6 / 16 Amp, piano flush type including taking down complete all as specified and as directed.
S&F bell push 5/6 Amps SP flush type complete all as specified and as directed.
S&F ceiling rose, surface bakelite, 65mm x 50mm, two to three terminals complete all as specified and as directed.
S&F for batten angle lamp holder insulated body with back plate suitable for batten fittings including complete all as specified and as directed.
S&F Ding dong sound door call bell electric AC 240 volt, 50 Hz ding dong type including taking down unserviceable complete all as specified and as directed.
Supply & Fixing medium step type fan regulator , 240 Volt AC, socket size, medium step" ISI marked complete all as specified and directed.
S&F Modular switch piano type (ISI marked), single pole, one way 6 Amp, 240 Volts complete all as specified and as directed.including taking down.
S&F Modular switch piano type (ISI marked), single pole, one way 16/15 Amps, 240 Volts including complete all as specified and as directed.including taking down.
S&F Modular socket outlet 3 pin, 6 Amp, 2 Module including complete all as specified and as directed.including taking down.
S&F Modular socket outlet, 2 in 1, 3/5 pin 6 / 16 Amp,2 Module complete all as specified and as directed.including taking down.
Supply & Fixing Modular step type fan regulator , 240 Volt AC, socket size, medium step" ISI marked complete all as specified and directed.including taking down.
S&F Modular bell push 5/6 Amps complete all as specified and as directed.including taking down.
M & L for sub main wiring in replacement of worn out aluminium conductor wire with two run of FR PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 6.0 Sqmm, 1100 Volts grade and one run of 4.00 Sqmm FR PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments and including drawing in PVC rigid conduit not less than 20 mm dia ISI marked medium grade incl fitting like bends, elbow, junstion box, reducer, junction boxes, tee bell mouth all fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete including Cutting & Chasing required on brick wall not exceeding 10 CM girth for concealed conduit wiring and making good to disturbed surface with cement mortar 1:3 and distemper / colour wash etc to match with existing surfaces including facing / finishing complete , connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good the disturbed surface to match with existing complete in all respect all as specified and directed. Note :- 1. Two run of single core cable with one run of contineous earth wire of copper conductor wire Flexible Multistrand) of FR PVC insulated and PVC Conduit of Size 25mm shall be measured and paid as one unit length
M & L for sub main wiring in replacement of worn out aluminium conductor wire with two run of FR PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 4.0 Sqmm, 1100 Volts grade and one run of 2.5 Sqmm FR PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments and including drawing in PVC rigid conduit not less than 20 mm dia ISI marked medium grade incl fitting like bends, elbow, junstion box, reducer, junction boxes, tee bell mouth all fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete including Cutting & Chasing required on brick wall not exceeding 10 CM girth for concealed conduit wiring and making good to disturbed surface with cement mortar 1:3 and distemper / colour wash etc to match with existing surfaces including facing / finishing complete , connecting incoming / outgoing electric connections by using required size copper lugs/thimbles and making good the disturbed surface to match with existing complete in all respect all as specified and directed. Note :- 1. Two run of single core cable with one run of contineous earth wire of copper conductor wire Flexible Multistrand) of FR PVC insulated and PVC Conduit of Size 25mm shall be measured and paid as one unit length
S & F service connection with twin core 10 Sqmm 240 volt heavy duty un armured PVC insulated multi stranded aluminium conductor cable in replacement of old unseriveable conductor cable complete.
S & F service connection with twin core 6 Sqmm 240 volt heavy duty un armured PVC insulated stranded aluminium conductor cable in replacement of old unseriveable conductor cable complete.
S & F service connection with twin core 4 Sqmm 240 volt heavy duty un armured PVC insulated stranded aluminium conductor cable in replacement of old unseriveable conductor cable complete.
Supply & Fixing in replacement of old unserviceavle DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 2 way, confirming to IS 13032 & 8623 complete all as specified and directed.
Supply & Fixing in replacement of old unserviceavle DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 4 way, confirming to IS 13032 & 8623 complete all as specified and directed.
Supply & Fixing in replacement of old unserviceable DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 8 way, confirming to IS 13032 & 8623 complete all as specified and directed.
Supply & Fixing in replacement of old unserviceable DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 12 way, confirming to IS 13032 & 8623 complete all as specified and directed.
Supply & Fixing in replacement of DB by TPN Distribution Box vertical 4 way, double door of protection grade IP 43 including provn for 4 Pole MCCB frame upto 200 Amps as incomer in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of way, confirming to IS 13032 & 8623 including chasing/cutting of wall and concealed and making good as existing surface complete all as specified and directed.
Supply & Fixing in replacement of DB by TPN Distribution Box 4 way, double door of protection grade IP 43 fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of way, confirming to IS 13032 & 8623 including chasing/cutting of wall and concealed and making good as existing surface complete all as specified and directed.
Supply and fixing of MCCB 125 Amps 16 KA with fixed thermal magnetic release frame 4pole all as specified and directed
Supply and fixing of MCCB 100 Amps 16 KA with fixed thermal magnetic release frame F2 optim 1.0 , 4pole all as specified and directed.
Supply & Fixing in repalcement MCB SPN, 32 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed.
Supply & Fixing in repalcement MCB SPN, 40 to 63 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed.
Supply & Fixing in repalcement MCB SP, 06 to 32 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed.
Supply & Fixing in repalcement MCB TPN, 63 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed.
Supply & Fixing in repalcement MCB TP, 100 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed.
S&F Wall mounted LED batten 18/20 Watt with 01 No LED tube rod, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver including dismantling taking down unsv LED/FTL fitting T8 type any type complete all as specified and directed.
S&F Wall mounted Mirror light LED fitting, 10 Watt, 1 Feet long incl integrated electronic driver including dismantling taking down unsv sketch fitting any type complete all as specified and directed.
S&F LED building security light 15 watt, 230V complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable.
S&F Bulk head fitting 10 watt LED incl water proof , weather proof all as specified and directed in replacement of old unserviceable filling .
Supply and fixing LED lamp 15 watt, CDL, B-22 cap, (Pin type), 230V, PF-0.95 (min) incl dismentling taking out unsv CFL/LED Bulb.
Supply and fixing LED lamp 12 watt, CDL, B-22 cap, (Pin type), 230V, PF-0.95 (min) incl dismentling taking out unsv CFL/LED Bulb.
Supply and fixing LED lamp 9 watt, CDL, B-22 cap, (Pin type), 230V, PF-0.95 (min) incl dismentling taking out unsv CFL/LED Bulb.
Supply and fixing wall mounted fancy decorative light fitting with 12 watt LED lamp clear white/warm white with acrylic/glass cover with holder, bracket and connected with ceiling rose /junction box wire 230 volt AC all as specified and directed.
Supply and fixing in replacement bakellite hylum sheet 3 mm thick complete with cutting and making size for fixing Serviceable switches and sockets (06 No's each) of size 8'' X 5'' complete all as specified and as directed.Note Unsv Switch and socket to be paid seperately
Supply and fixing in replacement bakellite hylum sheet 3 mm thick complete with cutting and making size for fixing Serviceable switches and sockets (12 No's each) of size 12'' X 10'' complete all as specified and as directed.Note Unsv Switch and socket to be paid seperately
Supply and fixing in replacement bakellite hylum sheet 3 mm thick complete with cutting and making size for fixing Serviceable switches and sockets (02 No's each) of size 5'' X 5'' complete all as specified and as directed.Note Unsv Switch and socket to be paid seperately
Supply and fixing in replacement plug top 15 Amps complete all as specified and as directed.
Supply and fixing in replacement plug top 5 Amps complete all as specified and as directed.
Supply and fixing in replacement of Mirror optic fitting by recess mounted mirror optic LED luminaire fitting not less than 100 lumen/watt , 36 watt, dimention 600mm x 600mm fitting for grid type ceiling including control driver and other accessories complete all as specified and directed.
M&L for earthing as per IS:3043 with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4 mm dia (8 SWG) as earthing lead protected by GI pipe medium grade 15 mm bore for protection of GI earth wire and 20 mm dia GI pipe medium grade for watering with alternate layers of charcoal /coke and salt including all accessories like nut, bolts, reducer, nipple, wire meshed/screened funnel and making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with PCC cover which shall be embedded in the block masonry including excavation works, refilling, connected to main switch/MCB DB for feeding the electric supply to domestic quarters compete all as specified as shown in electricall plateNo. 3 of SSR Part-I and testing of earth resistance as required. Note : Earthing lead/G.I.Earth wire upto 7.5 metre length shall be deemed to be included in quoted unit rate.
Taking out old unsv electric metre and deposit to E/M store and S&F for energy metre electronic type temper proof LCD Display with poly carbonate cover 230V, 10-60Amps accuracy class- I 50Hz confirming to IS 13779, IP-54 With parametres to show data, current reading,load ,PF, voltage and Kwh single phase a;; as specified and directed by Engg-in-Charge.
Taking out old unsv electric metre and deposit to E/M store and S&F for 3-Phase energy metre electronic type temper proof LCD Display with poly carbonate cover 440V,10-60 Amp accuracy class- I 50Hz confirming to IS 13779, IP-54 With parametres to show data, current reading,load ,PF, voltage and Kwh three phase all as specified and directed by Engg-in-Charge.
Supply and fix PVC Flexible pipe Grey/white colour complete all as specified and directed by E-in-Charge.
Supply and fixing Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps
Supply and fix as louver for size 300 mm dia exhaust fan of shape (round/square) incl dismantling old unsv as directed by EIC.
Taking down carefully storage type electric water heater (geysers) of any capacity including labour for repair/renewal/replacement of defective parts with new parts. Desconnecting of electric and water supply connection and descaling of geysers vesswel and reassembling of geysers, and installing the same in position and making necessary mounting/electric/water supply connection and testing complete all as specified and directed by Engr-In-Charge. Note :- New parts shall be measured and paid separately.
(a) Supply and fixing heating element of capacity 2 KW geysers of any make ISI marked complete as approved by Engr-In-Charge.
(b) Supply and fixing heating element of capacity 1.5 KW geyser of any make ISI marked complete as approved by Engr-In-Charge.
(c) Supply and fixing inlet/ outlet pipe assembly with rubber gasket inbcluding nuits, bolts, washers for geysers of 50/35/25 ltrs capacity complete as approved by Engr-In-Charge.
(d) Supply and fixing inner tank vessel made out of copper sheet 22 gauge for geysers of capacity 50ltrs complete as approved by Engr-In-Charge.
(e) Description all as per here in before but inner tank vessel capacity 25 litre complete.
(f) Supply and fixing indicator lamp 240 volts suitable for geyser as per site requirement complete all as specified & directed.
(g) Supply and fixing outer tank vessel capacity 25 litre complete.
(h) Supply and fixing glass wool suitable for geyser of capacity 50/35/25 ltrs complete all as directed and approved by Engr-In-Charge.
(j) Supply and fixing thermostate switch for geysers of capacity 50/25 Ltr ISI marked as per existing make as approved by Engr-In-Charge
(k) Supply and fixing NRV suitable for 15mm GI pipe ISI marked as per existing as approved by Engr-In-Charge
(l) Supply and fixing safety valve suitable for electric geyser complete of make as approved by Engr-In-Charge
(m) Supply and fixing flexi PVC connection 15 mm size with PTMT nuts of length 450 mm long for geyser
(n) Supply and fixing GI anchor bolts and Nuts with rowel plug for mounting the geyser.
M&L for tubes medium grade galvanised with all fitting and fixed of size 15 mm bore complete with walls and ceiling or laid in floors with iron spacers grouting in cement mortars, including taking out old unserviceable pipe and making good to disturbed surface with cement mortars and white washing to wall surface to matching existing surface complete all as specified and directed.
Disconnecting and taking down the ceiling fan of size 1200/1400 mm sweep carefully dismantling complete for servicing by cleaning the bearing/bush by cleaining solution and replacing the split pin and unserviceable items like bearing, bushes, rubber real, condenser, flexible cable, canopy, etc., assembling Ceiling fan and refixing in the original place connection and testing complete all well as specified and as directed Note;- Replacement of unserviceable items will be measured and paid underrespective items
(a) Supply and fixing of ball bearing for 1200/1400 mm sweep
(b) Supply and fixing of gun metal bushes for 1200/1400 mm sweep ceiling fan as per sample
(c) Supply and fixing condenser 2.5 Mfd for ceiling fan
(d) Supply and fixing condenser 4 Mfd
(e) Supply and fixing rubber reel suitable for 1200/1400mmsweep ceiling fan with nuts, bolts and wahsers etc.,
(f) Supply and fixing PVC 3 core Cord Flexible copper insulated cable 24/0.2mm size Black/Grey colour
(g) Supply and fixing down rod 400mm long with holes for nuts & bolts suitable size dia for housing ceiling fan complete all as specified and directed.
(h) Supply and fixing hanging clamps suitable for ceiling fan with rubber, nuts and bolts complete all as specified and directed.
Disconnecting and taking down the Exhaust fan/Wall fan with frame and louvers from wall of size 300/380/450 mm sweep carefully dismantling complete for servicing by cleaning the bearing/bush by cleaining solution and replacing the unserviceable items like bearing, condenser, flexible cable, etc., assembling Exhaust fan and refixing in the original place connection and realacement of nuts bolts and testing complete all well as specified and as directed Note;- Replacement of unserviceable items will be measured and paid under relevant items Supply and fixing. Labour charge for replacement of unserviceable parts will be deemed in quoted rate.
Supply and Fixing ball bearing and Bush for Exhaust fan 300 /380/450 mm sweep
Collecting the burnt ceiling fans of any make from AGE E/M store yard/ site taking out to reputed work shop dismantling removing the burnt winding, rewinding of ceiling fan with super enameled copper conduct winding wire of same gauge, insulating, varnishing, baking, including wornout bearing/bush greasing assembling and transporting the same and fixing and testing of following size at site all as specified and as directed by Engr-in-charge,
(a) 1200 mm Sweep
(b) 1400 mm Sweep
Collecting the burnt exhaust fans/wall fan of any make from AGE E/M store yard/ site taking out to reputed work shop dismantling removing the burnt winding, rewinding of Exhaust fan with super enameled copper conduct winding wire of same gauge, insulating, varnishing, baking, including wornout bearing/bush greasing assembling and transporting the same and fixing and testing of following size at site all as specified and as directed by Engr-in-charge,
(a) 450mm sweep
(b) 300 to 380 mm Sweep
Repair/replacement of electric pump motor of desert cooler including electric connection and testing for better performance all as directed by Engineer - in - charge
Repair / replacement of fan motor of desert cooler including electric connection and testing for better performace all as directed by Engr-in-charge
Replacement of 'T' junction for desert cooler for watering the three side of the desert cooler with nozzels
Replacement of Khas khas set for the doors of desert coolers all as directed by engineer-in-charge
Deduct Schedule of Credit of Rs. (-) 78485.00 (Minus) as listed in Schedule 'A' Part-II. Contract Sum shall be arrived after deducting the credit amount Note: Tenderers will not quote against this item being a firm amount.
M/SHansrajbuilder
DAVINDER SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .