Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.2 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹19.1 L+₹1.6 L (9.28%)Rejected-Finance NO 17 5 SOLOMON STREET ADHI NAGAR EAST TAMBARAM CHENNAI 600 059 | CHENNAI | TAMIL NADU | 600001 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹19.8 L+₹2.3 L (13.2%)Rejected-Finance NO 22 KUNNIJI NAGAR 1ST STREET EAST TAMBARAM CHENNAI 600 059 TAMIL NADU | CHENNAI | CHENNAI | TAMIL NADU | 600059 | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹20.1 L+₹2.6 L (15.1%)Rejected-Finance | L4 | Rejected-Finance BEING L4 | |
| 5 | L5₹20.4 L+₹3.0 L (16.9%)Rejected-Finance | L5 | Rejected-Finance BEING L5 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
3 Jun 2021, 6:00 pmClosed
GARRISON ENGINEER (AF)
Garrison Engineer (AF) Air Force Station Tambaram, Chennai - 600 046
REPAIRS TO FENCING DRAINS FOOT PATH RCC JALLI PLINTH PROTECTION PERIMETER WALL AT MADAMBAKKAM NARENDRA PLACE 9 PS UNIT AT AF STATION TAMBARAM
2021_MES_442683_1
GE(AF)/TBM/8447/E8
Open Tender
Civil Works
Item Rate
270 days
Air Force Station Tambaram
All as per Tender document
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER (AF)
₹40,000
Yes
5 Jul 2021
13 May 2021
5 Jun 2021
13 May 2021
3 Jun 2021
27 May 2021
14 May 2021 - 20 May 2021
Amount
Dismantling floor, hearth or wall tilling incl cement mortar bedding (But not backing) and removing serviceable tiles to store and rubbish off the permisses all as specified and as directed.
Demolition of brick work or stone / boulder masonry , built in cement mortar incl all quions orches pillars etc but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and as directed.
Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness below or above ground level all as specified and as directed.
M&L for chequred Cement Concrete Tiles with grey cement and pigments 20cmX20cm or 30cmX30cmX 22-25mm thick in Floors /Foot Path, etc., Set, Jointed and Pointed in Neat Cement Slurry with Grey Cement and Pigments, over and including 15mm thick Screed Bed in Cement Mortar 1:6, complete all as specified and as directed.
M&L for Machine pressed PVC moulded coloured interlocking paver block with grey cement and pigment of any approved shape and size conforming to IS 15658-2006 of 60mm thickness M-35 Grade all as specified and as directed.
M&L for sand filling under floors or in foundations including watering and consolidation all as specified and as directed.
Dismantling of stone slab/tiles of any description or thickness laid dry and pointed in floors or aprons etc.all as specified and as directed.
M&L for plain Cement concrete 1:4:8 type D2 using 40mm graded stone aggregate , 75mm thick , as in Sub-floors, sub-bases, floors and pavings, etc.all as specified and as directed.
M&L for plain Cement Concrete 1:2: type B1 using 20mm graded stone aggregate as in surface channel, all as specified and as directed
M&L for walling of random rubble uncoursed,well bounded,bedded and solidly hearted built in cement mortar 1:4 all as specified and as directed.
All as per item No 10 above but except stone. ( Note : Stones obtained from demolition shall be re used after throughly cleaning as specified and as directed.)
Extra over stone walling for hammer dressing with maximum depression on face from straight edge held against the dressed surfaces not exceeding 20 mm on lime or sand stone to face stones and dressing of face beds and joints as specified, of random rubble walling uncoursed or brought upto courses all as specified and as directed.
M&L for rendering on stone masonry surfaces or surface other than fair face of brick work on wall surfaces of 20 mm thick in cement mortar 1:4 finished fair and even without using extra cement all as specified and as directed.
M&L for brick work with sub class 'B' brick old size brick, straight or curved on plan in any radious built in cement mortar 1:4, complete all as specified and as directed.
All as per item No 14 above but except bricks all as specified and as directed. ( Note : Serviceable bricks obtained from demolition shall be reused after proper cleaning as specified and as directed.)
M&L for brick work with fly ash brick old size brick, straight or curved on plan exceeding 6 m mean radious built in cement mortar 1:4 complete all as specified and as directed.
M&L for form work to rough finished flat surface of concrete faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc. vertical or to batter all as specified and as directed.
M&L for Plain Cement Concrete 1:2:4 type B1 using 20mm graded stone aggregate as in walls or retaining walls, any thickness, size or shape including pilaster, buttresses, columns, pillars, boundary pillars and posts (including caps and bases) all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for, complete all as specified and as directed
M&L for Precast reinforced cement concrete 1:2:4, type B1 using 20 mm graded stone aggregate as in manhole cover slab, set in cement mortar 1:4, including forms, moulds required etc all as specified and as directed.
M&L for TMT bars 10mm dia and over, cut to length bent to shape required including cranking, bending etc., and binding with and including mild steel wire (annealed) not less than 0.9 mm dia all as specified and as directed
M&L for plain cement concrete 1:3:6 type C1 using 20 mm graded stone aggregate as in coping complete all as specified and as directed
Taking down cement plaster on brick wall/stone walls/concrete surfaces in any position such as wall, ceiling, floors, chajjas etc., including taking out joints hacking for key scrubbing down with water and removal of small shrubs grown over roofs, walls etc.all as specified and as directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surface in cement mortar 1:4, finished fair and even without using extra cement all as specified and as directed.
M&L for 40mm thick plain cement concrete in 1:2:4, type B1 using 20mm graded stone aggregate as in flooring finished even and smooth without using extra cement all as specificed and as directed.
Excavation in Post holes (or Similar Holes) each not exceeing 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exceeing 250mm watering and removing surplus Spoil to a distance not exceeding 50.00 Mtr and Making Good Surfaces in Soft/Loose Soil, complete all as specified and as directed.
M&L for plain cement concrete1:3:6 type C2 using 40mm graded stone aggregate as in foundations, filling and mass concrete, etc. for fixing RCC Fencing Posts, complete all as specified and as directed.
Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground all as specified and as directed.
M&L for reinforced cement concrete 1:2 :4 type B1 using 20mm graded stone aggregate as in Pre-cast fencing posts, struts etc. average sectional area exc. 100 Sqcm and not exc. 250 Sqcm with or without chamfe-red angles and flat, splayed, rounded or mitred tops including grouting in natural ground or in cement concrete complete all as specified and as directed. NOTE : Reinforcement shall be Measured and Paid separately under relevant Items.
M&L for TMT Bars 8mm dia cut to length, bent to shape as required including cranking, bending, hooking ends and binding with Mild Steel wire (annealed) not less than 0.9mm dia as in stirrups ,spacers and binders etc complete all as specified and as directed.
All as per item No.30 here-in-before but round bars Grade I, IS-432 (Part I) all as specified and as directed.
S&F mild steel work such as flat iron fillets for securing wire mesh, straps, ties, etc. and similar work, fabrication from steel sections conforming to Fe-410-0 or Fe-310-0 including all necessary welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated, complete all as specified and as directed.
S&F mild steel screw bolts (Machine Made) with hexagonal head at one end and screwed the other ends, each screwed end to be fitted with washers and one hexagonal nut, diameter of shank 5 to 10mm length of bolt exc 100mm but not exc. 150mm, complete all as specified and as directed.
Dismantling barbed wire as in fencing of any descriptions and remove the serviceable barbed wire rolled in drum and keep in safe custody for re-use, complete all as specified and as directed. NOTE : Each Line of Barbed Wire shall be Measured for Payment.
S&F galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing, stringing, tightening and fixing to MS Nibs embedded in Pre-cast RCC fencing posts, struts, etc. securing and tying at crossings with and provision of galvanised Mild Steel wire, complete all as specified and as directed.
Dismantling fencing wire mesh any type all as specified and as directed.
S&F PVC coating chain link MS galvanished fencing with 4 mm dia wire, size of mesh 75mm x 75 mm, made up to mattress or cages, all as specified and as directed.
Preparing new steel and Iron Surfaces of any descriptions, not exceding 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer, complete all as specified and as directed.
M&L for precast Cement concrete 1:2:4 type B0 using 12.50 mm graded stone aggregate as in louvres and jallies ,50 mm thick , set in cement mortar 1:4 complete
M&L for Precast cement concrete solid block masonary using cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate built in cement mortar 1:4 complete all as specified and as directed.
M&L for rendering on fair faces on wall surfaces 15 mm thick in cement mortar 1:4 mixed with water proofing compound at the rate of 2% by weight of cement on roof surfaces, finished fair and even without using extra cement. NOTE : Water proofing compound shall be measured and paid separately
Supply only integral water proofing compound
Preparation of new plastered surfaces and applying two coats of cement based paint any tint over one coat of alkali resistant primer all as specified and as directed.
kcs builders
Sri Sankar Enterprises
SINI PROMPT
Varsa Constructions
vrk constructions
M/s. V. BAKTHAVATSALAM & CO
SB RAJU SONS
M R Govinda Reddy and Sons
RAVI ENTERPRISE
K S MUTHU CONSTRUCTTIONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .