Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.6 LAccepted-AOC 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹37.8 L+₹2.2 L (6.13%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹38.4 L+₹2.8 L (7.75%)Rejected-Finance 40 6 UKHARA PO PRATAP PURA AGRA UP 282001 | AGRA | AGRA | UP | 282001 | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹38.5 L+₹2.8 L (7.90%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 |
Tender Value
₹36.8 L
EMD Value
₹73,600
Closing Date
29 May 2023, 6:00 pmClosed
GE (East) Agra
Garrison Engineer (East) Agra, Military Engineer Services, Gwalior House, 62 Taj Road Agra Cantt-282001
PROVN OF OVERHEAD CONDUCTOR WITH UNDERGROUND ELECTRIC CABLE AT AATS SPL REP TO 500 KVA DG SET AT 509 ABW AND PROVN OF 05 X BATHING POINT WITH 01X WATER TANK AND SHOWER NEAR BLDG NO 322 CADET LINE AT PHW AATS UNDER GE (EAST) AGRA
2023_MES_591330_1
9545/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
AGRA (UP)
Please refer tender documents
9 documents required · 9 mandatory
₹500
Yes
GE (East) Agra
₹73,600
Yes
30 Jun 2023
26 Apr 2023
5 Jun 2023
26 Apr 2023
29 May 2023
10 May 2023
Amount
Surface excavation n.exc. (not exceeding) 30 cm deep and averaging 15cm deep and getting out complete in soft/loose soil all as specified and directed.
M&L Hardcore of borken bricks of gauge n.exc 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete, all as specified and directed.
M&L for 100mm thick cement concrete type D-2, 1:4:8 mix (using 40mm graded stone aggregate) as in subbase of hardstanding including from work etc complete, all as specified and directed.
M&L for Plain Cement Concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) cast in situ in lintels upto 1.5M span, cills and other similar bands, plinth courses, parapets, copings, bed plates, hold fast and the like including weathering, slightly rounded or chamfered angles and throating including use and waste of form work etc.complete all as specified and directed.
M & L Brick work with sub class 'B' bricks old size straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and as directed.
M&L for 15mm thick rendering in CM 1:4 on brick or concrete surfaces with water proffing compound @ 2% by weight of cement finished fair complete all as specified and directed. Note : Water proofing compound will be measured and paid seperately under respctive tiem of Sch 'A'.
M&L for 15mm thick rendering in CM 1:6 on other than fair faces of brick or concrete surfaces with approved quality of admixture chemically manufactured for hardened, roughly finished surfaces complete all as specified and directed.
Supply only Integral waterproofing compound liquid complete all as specified and directed.
M&L non skid joint free coloured ceramic tiles (1st quality/premium quality) 7 to 8 mm thick (squre/ rectangular) area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed or bedding layer of CM (1:6) complete all as specified and directed.
M&L for Coloured Glazed ceramic tiles (Digital & designer pattern) in vertical surface 350X 250X 7mm /450 x 350 x 7mm thick/300x450x7mm, set and jointed in neat cement slurry and pointed in white or Coloured cement to match tiles including 10mm thick rendering in CM 1:3 on brick wall complete all as specified and as directed.
S&F 15mm bore steel water tubing medium grade, galvanised including fittings and fixed to walls, ceilings, floors or laid in floors complete all as specified and directed.
S&F 20 mm bore steel water tubing medium grade, galvanised including fittings and fixed to walls, ceilings, floors or laid in floors complete all as specified and directed.
S&F Swivel shower of PTMT any colour for fixing with 15mm pipe (minimum weight 40gms) including fixing to steel pipe or union complete all as specified and directed.
S&F 75mm dia of outlet PVC (SWR) floor trap, plain with grating encl. Jointing with solvent cement to waste pipe complete all as specified and directed.
S&F 150mm square PTMT grating with openable flap (Min weight 100 gms) complete all as specified and directed.
S&F 1000 liters capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified in SSR Part -I and directed.
S&F 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe 20mm dia (minimum weight-210 gm) complete all as specified and directed.
S&F bid taps cast copper alloy with crutch of butterfly haandle, screwed down, screwed for iron pipe or for brass ferrule and fixed but fancy type chromium type complete all as specified and directed.
S&F stop valves, cast copper alloy screwed down, high pressure, with crutch or butter fly handle, screwed both end for iron pipe or for unions and fixed but fancy type chromium plated with long shank and cup (concealed type) complete all as specified and directed.
S&F towel rail 600mm long of PTMT with and including chromium plated brass screws and wooden / plastic cleats (minimum weight 190gms) complete all as specified and directed.
Dismantling of old unserviceable ACSR conductor any size and any type complete all as specified and directed.
Dismantling of insulators any type and any size complete all as specified & directed.
Dismantling of cross-arms of M.S. channel or angle sections, GI Wire, nuts and bolts of any size/type retrieved from Overhead lines complete all as specified & directed.
Dismantling of Service wire of any size or type complete all as specified & directed.
Dismantling of LT cable of any size and any type complete all as specified & directed.
Excavating in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in soft soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as specified and directed.
Removing exeavated material n. exc 50 m and depositing where directed at a level n. exc 1.5 m above starting point complete all as specified and directed.
Material and labour for sand cushioning with dry river sand unwashed in trenches for cushioning of underground cable line including spreading, leveling, gently pushing around cable completed all as specified and directed. Note :- Punned thickness only shall be maeasured and paid.
Supply and laying well burnt sub class ‘B’ bricks. ( designated 75) locally available best quality laid dry in trenches for protection of underground cable all as specified and directed.
Supply and lay HDPE pipe medium class, ISI Marked double wall corrugated as in cable protection pipe of outer dia 40mm including all fittings complete all as specified and directed.
Supply and lay HDPE pipe double wall medium class, ISI Marked corrugated as in cable protection pipe of outer dia 50 mm including all fittings complete all as specified and directed.
Supply and lay HDPE pipe double wall medium class, ISI Marked corrugated as in cable protection pipe of outer dia 63 mm including all fittings complete all as specified and directed.
Supply and lay HDPE pipe double wall medium class, ISI Marked corrugated as in cable protection pipe of outer dia 90 mm including all fittings complete all as specified and directed.
M&L for drilling suitable dia horizontal bore holes for insertion/ laying of 40 mm to 90 mm bore HDPE pipe of any description below/under existing road surfaces / floors at a level not less than 0.60 metre etc with using mechanical / or manual devices as required at site including making good the disturbed surfaces to match with the existing after laying pipes complete all as specified and directed by Engineer-in-Charge. Note : (i) Cost of equipment tools and plant material (horizontal boring rig machine) required for boring shall be arranged by contractor at no extra cost to the Govt.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor ISI marked confirming to IS 7098 Part-I of size 10 sq mm 2 core in trench/floor/on pole/wall, complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor ISI marked confirming to IS 7098 Part-I of size 16 sq mm 4 core in trench/floor/on pole/wall, complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor ISI marked confirming to IS 7098 Part-I of size 35 sq mm 3.5 core in trench/floor/on pole/wall, complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor ISI marked confirming to IS 7098 Part-I of size 70 sq mm 3.5 core in trench/floor/on pole/wall, complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor ISI marked confirming to IS 7098 Part-I of size 120 sq mm 3.5 core in trench/floor/on pole/wall, complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor ISI marked confirming to IS 7098 Part-I of size 240 sq mm 3.5 core in trench/floor/on pole/wall, complete all as specified and directed.
Supply & fixing , Rigid non-metallic PVC conduit of size 20 mm dia ISI marked heavy duty (fixing from junction box to street light on pole) for passing cable of size 2.5 Sqmm 2 Core, including clamps made out of MS flat 25x6 mm and necessary nut, bolts and washers, complete all as specified and directed.
Supply and fix junction/looping box polycarbonate alongwith clamps complete, pole mounted right hinged looping box of size 300mm x200mm x105mm with MCB SP 6 Amp capacity, aluminum bus bar-4 Nos fixed on ebonite insulator suitable capacity for 3 phase and neutral complete with necessary MS clamp made of 25 x3 mm MS flat, bolts, Nuts, washers etc for fixing to steel tubular /rail pole including all accessories. complete all as specified and directed.
Supply and fixing Outdoor type cubicle Bus Bar aluminium Chamber 400 Amps for three phases, 4 wire IP-65 protection rupturing capacity at 415 volts , factory made having powder coating including necessary angle iron and PCC foundation of size as directed and earth work, complete all as specified and directed
Supply and fixing CRCA Sheet, MCCB Enclosure 2mm thick for MCCB of capacity 250/200/160/100 Amp, rupturing capacity at 415 volts , factory made having powder coating including necessary grouting on walls and make good to disturbed surfaces, completed all as specified and directed.
Supply and fixing in repair MCCB 4 pole, 160 Amps, 50 Hz, Icu=16 KA at 415 volts with thermal magnetic alongwith adjustable magnetic protection for current setting Icu=Ics = 100% with adjustable over load setting (minimum 70% to 100%) value from 10 to 15 times of related capacity as per IEC-60947-1 and 60947-2 standard complete all as specified and directed.
Supply and fixing in repair MCCB 4 pole, 100 Amps, 50 Hz, Icu=16 KA at 415 volts with thermal magnetic alongwith adjustable magnetic protection for current setting Icu=Ics = 100% with adjustable over load setting (minimum 70% to 100%) value from 10 to 15 times of related capacity as per IEC-60947-1 and 60947-2 standard complete all as specified and directed.
Supply & fixing LED security light compact & trendy of 35 watt with aluminium pressure diecast housing, IP 65 protection, luminaire lumens > 3000 lumens/W and in built electronic driver prewire upto terminal block with driver efficiency > 85 %, power factor > 0.95, colour temp 6500 K Surge protection 3.5 KV, 50000 burning hrs (min) as per L70 Criteria, fixed to pole or wall of building with and including suitable Bracket made out of 40 mm dia GI light grade pipe, 1.20 m long bent to shape by cutting & welding as required & directed and fixed with two Nos of FI clamps 50x6 mm to be tightened with suitabe size of bolts, nut and washers and including painted with two coat of aluminium paint over a coat of red oxide primer, and including connecting the fitting to electric source with & including twin twisted copper flexible wire of size 0.75 Sqmm including all accessories and fixing arrangements for fixing the light fitting complete all as specified & directed.
Supply & fixing LED security light compact & trendy of 60 watt with aluminium pressure diecast housing, IP 65 protection, luminaire lumens > 3000 lumens/W and in built electronic driver prewire upto terminal block with driver efficiency > 85 %, power factor > 0.95, as per IEC 61000-3-2, colour temp 6500 K Surge protection 3.5 KV, 50000 burning hrs (min) as per L70 Criteria, fixed to pole or wall of building with and including suitable Bracket made out of 40 mm dia GI light grade pipe, 1.20 m long bent to shape by cutting & welding as required & directed and fixed with two Nos of FI clamps 50x6 mm to be tightened with suitabe size of bolts, nut and washers and including painted with two coat of aluminium paint over a coat of red oxide primer, and including connecting the fitting to electric source with & including twin twisted copper flexible wire of size 0.75 Sqmm including all accessories and fixing arrangements for fixing the light fitting complete all as specified & directed.
Supply & fixing Bracket for security lights made out of 40 mm dia GI light grade pipe, 1.20 m long bent to shape by cutting & welding as required & directed and fixed with two Nos of FI clamps 50x6 mm to be tightened with suitabe size of bolts, nut and washers and including painted with two coat of aluminium paint over a coat of red oxide primer, and including connecting the fitting to electric source with & including twin twisted copper flexible wire of size 0.75 Sqmm including all accessories and fixing arrangements for fixing the light fitting complete all as specified & directed.
Material and labour Cable Route indicator showing "MES HT/LT U/G 11/1.1KV" size 60cm height X 30cm wide X 50mm thick tapered on top) and route of cable with arrow (Embossed or engraved) made of RCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) 50 mm thick reinforced with 8 mm dia TMT bar at the rate of 100 mm centre to centre in suitable shape and size 60 cm x 30 cm x 50 mm thick fixed in PCC block 1:2:4 type B-2 (using 40mm graded aggregate)(size of block 30cmx 30x15cm) of 30 cm below ground level and 30cm above ground to show clear indication of cable including painting the complete slab with red paint and marking the engraved/embosed letters/arrow with white paint complete all as directed. Note :- Quoted rate shall be deemed to included the cost of excavation, returning, filling and removal of excavated earth upto a distance of not exceeding 30 mtr complete.
M&L for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanised iron strip 25x4mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 32mm GI light grade pipe for earth strip protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
Supply, installation , Testing and Commissiong Outdoor type cubicle panel board inner cell made of 2 mm thick and outer cell made of 3.15mm CRCA sheet for three phases, 4 wire, 415 Volts , 50 Hz with IP-54 protection rupturing capacity at 415 volts , factory made in an approved factory having seven tank treatment process for powder coating with thickness not less than 60 microns with paint shade RAL -7035 provided with suitable gasket to make it dust/vermin proof and mounted on PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 Type C-2 , using 40 mm graded crushed stone aggregate as recommended by manufacturer or directed including earth work complete & general construction comprising of the following :-
(a) INNER SHELL :- Inner shell made out of 2 mm thick CRCA sheet duly compartmentalised and separation form 3 (b) for each control gear, front & back openable double door system lockable /openable by key from both sides fancy locks , having louvers & air vent gasket fro natural flow of air, "U" type gasket shall be used to make the inner shell completely vermin proof & to accommodate incomer / outgoing MCCBs and electrical grade busbar with stand with heat shrinkable sleeves alonwith shrouds for joints & eath duly colour coded shall be mounted on suitable size "F" class insulator made of nonhygroscopic , noncumbustile , track resistance , high strength FRP/SMC/DMC material at an interval not less than 500 mm through out the length of the TPN busbar . The cubical incomer MCCB as well as out going shall have copper TPN extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeder, the extension links shall not be less than 300 mm long supported on suitable size "F" class insulator made of non hygroscopic , noncumbustile, track resistance , high strength FRP/SMC/DMC material having provision for termination of incomer and outgoing cables. All inter connections between the main busbar as well as outgoing feeder shall be arried out with TPN copper busbar of rating not less than 1.5 times rated capacity of individual outgoing feeder and should be insulated with heat shrinkable PVC sleeves.
All control wires shall be with 2.5 sqmm multistranded copper conductor and shall be properly bunched , tied, ferruled for proper identification and crimped with adequate size of copper lugs. The cubical shall have a bottom channel of size 75 x 40 mm duly coated with zinc metal coating having thickness not not less than 100 microns. A detachable predrilled gland plate of thickness 3.15 mm powder coated should be used at the bottom . The inner shell shall be of powder coated Siemens grey structtural RAL -7032 shade. An inspection lamp LED 5 watt with movable non ferrous chromium plated arm fitted on top side of inner shell shall be provided . The degree of protection for inner shell shall be IP-42 and carry the following controlls :-
Incoming: (a) Bus bar chamber comprising 4 Nos copper strip bus bars PVC insulated made of copper strip with current capacity 500 Amp with stand heat shrinkable sleeking alongwith shrouds for joints , PVC sheathed with colour coding . (b) Incommer MCCB, 4 pole having current ratings 320 Amps, AC 415 Volts, with Icu= 25 KA , Ics = 100% of Icu, with thermal magnetic release, complete with spreader links- Qty - 01 No (c) Multifunctional digital panel meter with LCD display flush mounting type of size 96X96 mm, accuracy class 1, suitable for CTs with secondary current 5A, (d) MCCB, 4 pole having current ratings 100 Amps, AC 415 Volts, with Icu= 16 KA, Ics = 100% of Icu, with thermal magnetic release, complete with spreader links- Qty - 04 Nos (e) MCB TPN 32 Amps, C Curve, 415 Volts, Qty - 02 Nos (f) MCB, DP 16 Amp, C Curve, 240 volts, 10 KA - Qty - 01 No
All as per Item No 53.00, 53.01 & 53.02 here in before but Incoming: (a) Bus bar chamber comprising 4 Nos copper strip bus bars PVC insulated made of copper strip with current capacity 500 Amp with stand heat shrinkable sleeking alongwith shrouds for joints , PVC sheathed with colour coding . (b) Incommer MCCB, 4 pole having current ratings 320 Amps, AC 415 Volts, with Icu= 25 KA , Ics = 100% of Icu, with thermal magnetic release, complete with spreader links- Qty - 01 No (c) Multifunctional digital panel meter with LCD display flush mounting type of size 96X96 mm, accuracy class 1, suitable for CTs with secondary current 5A, (d) MCCB, 4 pole having current ratings 100 Amps, AC 415 Volts, with Icu= 16 KA, Ics = 100% of Icu, with thermal magnetic release, complete with spreader links- Qty - 05 Nos (e) MCB, DP 16 Amp, C Curve, 240 volts, 10 KA- Qty - 01 No
All as per Item No 53.00, 53.01 & 53.02 here in before but Incoming: (a) Bus bar chamber comprising 4 Nos copper strip bus bars PVC insulated made of copper strip with current capacity 600 Amp with stand heat shrinkable sleeking alongwith shrouds for joints , PVC sheathed with colour coding. (b) Incommer MCCB, 4 pole having current ratings 400 Amps, AC 415 Volts, with Icu= 25 KA, Ics = 100% of Icu, with thermal magnetic release, complete with spreader links- Qty - 01 No (c ) Multifunctional digital panel meter with LCD display flush mounting type of size 96X96 mm, accuracy class 1, suitable for CTs with secondary current 5A, (d) MCCB, 4 pole having current ratings 200 Amps, AC 415 Volts, with Icu= 25 KA , Ics = 100% of Icu-01 No (e) MCCB, 4 pole having current ratings 160 Amps, AC 415 Volts, with Icu= 25 KA , Ics = 100% of Icu, with thermal magnetic release, complete with spreader links- Qty - 02 Nos (f) MCCB, 4 pole having current ratings 125 Amps, AC 415 Volts, with Icu= 16 KA, Ics = 100% of Icu, with thermal magnetic release, complete with spreader links- Qty - 06 Nos (g) MCB TPN 32 Amps, C Curve, 415 Volts, Qty - 02 Nos (h) MCB, DP 16 Amp, C Curve, 240 volts, 10 KA - Qty - 01 No
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, 4 Sqmm one twin core cable flat or circular. Complete all as specified and directed.
Removing of old paint by removers scrubing from LT steel poles 9 meter long, cross arms clamps etc for painting and M &L for painting with one coat of superior quality aluminum paint on exposed surface of poles and street light bracket mounted on the poles,junction box etc and paste reflective vinyl Radium Yellow and Red of size 10 cm (which reflect from the lights) upto1.5 Mtr height from ground level and writing pole Nos etc. written on it with black synthetic enamel paint compete all as specified and directed. Make of paint : Asian Paint(Apcolite), Shalimar(Superlac Hi Gloss), Nerolac Paint (Nerolac full Gloss).
Supply and fix street light timer switch with voltage mounting device enclcosed in SMC Enclosure for automatic and manual switching of street light based on LUX level of natural light , The sensor along with suitable power contactor MCB support terminal shell be housed in enclosure complete made out of anti rust/ shock proof/ termite proof/ confirming to IP 54 suitable for 5-8 KW (40 Amp) load compete all as specified and directed Make of switch: Timer Nature switchmodel No Swadeep-02EC-k5w1P-VMS/ or equivalent of Legrand
M&L for dismantling/taking out of Engine from 500 KVA DG set (SM No-580/6166/DG/12) of any make & type by strip opening and repairing of DG set engine with following repairs/replacement of worn out spares parts and refixing of the same after repair/replacement of spare parts including painting of the complete DG set including canopy with one coat of red oxide primer over one coat of synthetic enamel paint and comprehensive servicing of the DG set including testing & commissioning on full load & entire satisfaction of Engineer-in-Charge complete all as specified and as directed. Note:- (i) Spare parts shall be measured and paid as supply only under appropriate items of Sch "A". (ii) Servicing of the 500 KVA DG set and labour charges for replacement of all items will be included in this item rate. (iii) Testing shall be carried for 08 hrs continuous and diesel for testing shall be supplied by the department free for testing. (iv) All repair items has been considered in above work. However repair of any job item of DG set costing not more than Rs 500.00 are deemed to be included in the rate quoted by contractor. No extra amount shall be paid to the contractor on this account. (v) Contractor is advised to visit site (With Engineer-in-charge/JE incharge) for check the condition of DG set before quoting the rate. (vi) Spare parts shall be purchased from OEM or authorised dealers only.
Cylinder liner
Supply only Piston assly
Supply only Ring Set
Supply only Gudgeon pin
Supply only Seat insert for inlet & exhaust
Supply only Inlet valve & exhaust valve
Supply only Packing set
Supply only Turbo charger
Supply only Injector
Supply only Water line hose set and clamp complete
M&L for repair of radiator cleaning with jet pressure, soldering/brazing of damage copper tube complete and refixing of the same after repair/servicing in original condition
Repair of head & facing with lathe machine in workshop complete and refixing of the same after repair in original condition.
Supply only B check kit for 500 KVA DG set (Oil filter-2, Diesel filter-2, bypass filiter-1 and air filter 01 No) complete all as specified.
Supply and filling of engine oil 15W/40 complete all as specified and directed. Make- Bharat petroluem/Valvoline/Servo
Supply and filling of coolant for radiator of DG sets complete all as specified and directed Make-Castrol/TVS
Supply & fixing in renewal of maintaince free Battery-12 Volts,180 Amps for 500 KVA DG set. Make : EXIDE/AMARON/AMCO/SF
M&L for repairing of canopy doors complete with repair/replacement of door lock, door handle, hinges including denting of doors including painting with match the existing surface complete all as specified and directed
M&L for disconnecting & calibrating of fuel pump of 500 KVA DG Set and repair/replacement of element, delivery valve, Rack & tappet, tappet roller & u/s minor parts including overhauling calibration and refixing of the same after repair/replacement/calibrating and testing complete all as specified and directed. Note- The fuel pump must be repaired by the OEM or authorised workshop and test certificate submit by contractor.
M&L for replacement of AVR (Automatic voltage regulator) suitable for 500 KVA DG set complete all as specified and directed by Engineer-in-Charge.
M/S J J ENTERPRISES
Attar Singh and Sons
Balaji Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .