Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.9 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹39.8 L+₹88,618 (2.28%)Rejected-Finance BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹41.5 L+₹2.7 L (6.83%)Rejected-Finance COLABA MUMBAI | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹43.3 L+₹4.4 L (11.4%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹49.3 L+₹10.5 L (26.9%)Rejected-Finance 67 A HAFIZALI BAHADUR KHAN MARG SURAJI COMPOUND BEHIND KHATAU MILL BYCULLA W MUMBAI 400011 BRITE INDUSTRIES 67 A HAFIZALI BAHADUR KHAN MARG SURYAJI COMPOUND BEHIND KHATAU MILL MUMBAI | MUMBAI | MAHARASHTRA | 400011 | L5 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹82,800
Closing Date
21 Jun 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NW) Navy Nagar, Colaba, Mumbai
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
PROVN OF DEFICIENT STANDBY POWER SUPPLY FOR LIFT TO CERTAIN BLDGS AT RS COLABA UNDER GE NW NAVY NAGAR COLABA MUMBAI
2021_MES_441402_2
8491/E8
Open Tender
Civil Works
Item Rate
180 days
GE (NW) Navy Nagar, Colaba
Class D and category b(i)
7 documents required · 7 mandatory
₹500
GE NW NAVY NAGAR COLABA MUMBAI
₹82,800
21 Aug 2021
1 Jun 2021
22 Jun 2021
1 Jun 2021
21 Jun 2021
8 Jun 2021
1 Jun 2021 - 14 Jun 2021
60 days
Amount
Supply and installation, testing and commissioning of diesel engine driven generating set of capacity 200 KVA output at NTP with AMF control panel, 415 Volts, 50 C/S AC, 3 phase 4 wire at power factor of 0.8 lagging all as per IS- 4272/2001, DG set mounted on common base plate and directly coupled through flexible coupling of diesel engine with cushy foot mountings (anti vibration) pad in and including acoustic insulated encloser/canopy with noise level less 75 db at 01 metre distance from DG set, complete with self starting system including accssories, equipment control panel etc complete with following features. (a) Alternator (bush less) shall be design for an output of 200 KVA at full load for continuos rating at 0.80 PF AC 3 phase 4 wire 415 Volts 50 C/S with 1500 RPM speed, self excited, self regulated, screen protected, drip proof construction with insulation class 'H' with two end shield ball/roller bearing with damper winding in each pole faces as per IS-4722 or BS 2613-1970 complete all as specified and direcetd. (b)Diesel Engine :- Diesel Engine water cooled of BHP not less than 310 HP and with electric start suitable to drive above alternator independently, coupled directly through flexible coupling, multi cylinder four stroke, cold starting, 1500 RPM industrial type as per BS-649 or IS-1601 with A1 electronic governor suitable to regulate speed of DG set from No load complete with fuel tank of capacity as per manufacturer recommendations, fuel lines, exhaust pipe duly insulated with asbestos rope and with support and silencer mufflers etc for continuous operation and standard accessories, sump pre heaters etc all as specified and direcetd.
Alternator (bush less) shall be design for an output of 200 KVA at full load for continuos rating at 0.80 PF AC 3 phase 4 wire 415 Volts 50 C/S with 1500 RPM speed, self excited, self regulated, screen protected, drip proof construction with insulation class 'H' with two end shield ball/roller bearing with damper winding in each pole faces as per IS-4722 or BS 2613-1970 complete all as specified and directed.
Diesel Engine :- Diesel Engine water cooled of suitable BHP for 200 KVA DG set and with electric start suitable to drive above alternator independently, coupled directly through flexible coupling, multi cylinder four stroke, cold starting, 1500 RPM industrial type as per BS-649 or IS-1601 with A1 electronic governor suitable to regulate speed of DG set from No load complete with fuel tank of capacity as per manufacturer recommendations, fuel lines, exhaust pipe duly insulated with asbestos rope and with support and silencer mufflers etc for continuous operation and standard accessories, sump pre heaters etc all as specified and directed.
Control Panel : - Control panel of DG set shall comprising of indicator lamps LED type, hours meter/RPM indicator, lub oil pressure gauge, water temperature gauge, oil temp gauge & fuel level indicator safety control for engine shut off (trip with visual indication) for low lube oil pressure, safety control for engine shut off (trip with visual indication) for high water temperature, safety control (trip with visual indication) for low fuel level with protection of short circuit/over load and auto shut down.
Electric starter equipment :- The equipment will comprise the followings : (i) Maintenance free sealed lead acid battery 12 V and suitable AH & Battery lead of adequate size and capacity (ii) Starter Motor (iii) Starter gearing (iv) Start/Stop push button. (v) Invertor cum battery charger 500 VA capacity suitable to work on 230 Volts 50 Hz AC supply system for charging of DG Set batteries externally when DG set is in off position (vi) Alternator/Dynamo of suitable capacity to charge the batteries while DG sets running complete with cut out all as per manufacturer recommendation os required at site or directed by Engr-in-Charge Note:- (a) Pre dispatch inspection of the DG set will be carried out by Rep of Accepting Officer. The expenditure involved shall be deemed to be included in qoted rates. (b) Submitting power and control wire diagram of each DG set separately.
Supplying and laying with commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of size 185 sqmm 3.5 core laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles/lugs complete all as specified and directed.
All as per Item No 2.00 above but of size 95 sqmm, 3.5 core.
All as per Item No 2.00 above but of size 70 sqmm, 3.5 core.
All as per Item No 2.00 above but of size 25 sqmm, 4.0 core.
Exavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out for laying of cables, in any type of soil. Note : Rate includes removing of paver blocks carefully and stack properly for refixing after laying of cables .
Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm with excavated soil all as specified and directed.
Removing excavated material from the site of work and transporting out of Station/site of work suitable to the contractor all as specified.
Supplying, filling, spreading, leveling in layers and well ramming dry river sand around cable in trenches for cable cushioning all as specified and directed.
Cutting existing road surface or hard standing, bituminous topping 15 cm but n exc 30cm girth for laying of pipes/ cables and making good distrubed surface to match with existing complete.
Supply and laying un-reinforced pecast concete cable covers LV type 1, flat size 250mm x 150mm x 40 mm .
M & L for fixing of old interlocking paver tiles/blocks of any sizes recovered form item SI. No. 6 including laying over 25 mm thick sand bed compacted complete as specified and directed.
M & L for 60 mm thick coloured interlocking paver tiles/ blocks, lacquer finish of size 250 X 250 mm, having compressive strength of 35N/Sqmm, zig-zag (uni-paver) shape in flooring tested as per IS : 15658-2006, with and including laying over 50 mm thick sand bed compacted complete as specified and directed.
M&L for High density poly-ethylene pipes (HDPE) of pressure 4 kgf/cm2 pipe, 90 mm dia for road crossing of cable or for cable protection of cable above/under ground surface all as specified and directed.
M&L for High density poly-ethylene pipes (HDPE) of pressure 4 kgf/cm2 pipe, 75 mm dia for road crossing of cable or for cable protection of cable above/under ground surface all as specified and directed.
M&L for fabrication of Panel, double door made out of 2mm thick CRCA sheet, CPRI approved, indoor type suitable for 3 phase, 4 wire, 415 volts, with Copper busbar strip of 1200 amps capacity with necessary clamps, nuts, bolts and washers, internally prewired with all connecting accessories, floor mounted type made with angle iron legs 40x40x4 mm thick, powder coated painting incl foundation 60 cms above the ground level in PCC 1:3:6 type C2 all as specified & directed consisting of following :-
Incoming DPX3 630, MCCB 400 Amps, 4 Pole, 36 kA, thermal magnetic release, Ics=100% Icu - 01 Nos, Cat No- 422007 of Make- Legrand or equivalent in Siemens/ABB/Schneider.
Outgoing DPX3 250, Thermal magnetic release MCCB 200A, 36KA, 4P. Make : Legrand : Cat ref : 420248 -01 Nos or equivalent in Siemens/Schneider/ABB
DPX3 160, MCCB 100 Amps, 4 Pole, 25 kA, thermal magnetic release, Ics=100% Icu - 02 Nos, Cat No- 420055 of Make- Legrand or equivalent in Siemens/ABB/Schneider.
Digital Ammeter Make-HPL/L&T/AE - 01 Nos
Digital Voltmeter Make-HPL/L&T/AE - 01 Nos
Phase indicator lamp R,Y & B - Set of 3
Copper Bus bar 1200 Amps rated of suitable size - Set of 04
M&L for LT FPB, weather proof, vermin proof, double door made out of 3mm thick CRCA sheet, CPRI approved, out-door type (IP-54) suitable for 3 phase, 4 wire, 415 volts, with Copper busbar strip of 600 amps capacity with necessary clamps, nuts, bolts and washers, internally prewired with all connecting accessories, floor mounted type made with angle iron legs 40x40x4 mm thick, powder coated painting incl foundation 60 cms above the ground level in PCC 1:3:6 type C2. all as specified & Directed consisting of following :-
Incoming DPX3 160, Thermal magnetic release MCCB 160A, 25KA, 4P. Make : Legrand : Cat ref : 420057 -01 Nos or equivalent in Siemens/Schneider/ABB
Outgoing DPX3 160, MCCB 63 Amps, 4 Pole, 16 kA, thermal magnetic release, Ics=100% Icu - 04 Nos, Cat No- 420013 of Make- Legrand or equivalent in Siemens/ABB/Schneider
Digital Ammeter Make-HPL/L&T/AE - 01 No
Digital Voltmeter Make-HPL/L&T/AE - 01 No
Phase indicator lamp R,Y & B - Set of 3
Copper Bus bar 600 Amps rated of suitable size - Set of 04
M&L for LT FPB, weather proof, vermin proof, double door made out of 3mm thick CRCA sheet, CPRI approved, out-door type (IP-54) suitable for 3 phase, 4 wire, 415 volts, with Copper busbar strip of 600 amps capacity with necessary clamps, nuts, bolts and washers, internally prewired with all connecting accessories, floor mounted type made with angle iron legs 40x40x4 mm thick, powder coated painting incl foundation 60 cms above the ground level in PCC 1:3:6 type C2. all as specified & Directed consisting of following :-
Incoming DPX3 250, Thermal magnetic release MCCB 200A, 36KA, 4P. Make : Legrand : Cat ref : 420248 -01 Nos or equivalent in Siemens/Schneider/ABB
Outgoing DPX3 160, Thermal magnetic release MCCB 160A, 25KA, 4P. Make : Legrand : Cat ref : 420057 -01 Nos or equivalent in Siemens/Schneider/ABB
DPX3 160, MCCB 63 Amps, 4 Pole, 16 kA, thermal magnetic release, Ics=100% Icu - 04 Nos, Cat No- 420013 of Make- Legrand or equivalent in Siemens/ABB/Schneider
Digital Ammeter Make-HPL/L&T/AE - 01 No
Digital Voltmeter Make-HPL/L&T/AE - 01 No
Phase indicator lamp R,Y & B - Set of 3
Copper Bus bar 600 Amps rated of suitable size - Set of 04
M & L for earthing with copper earth plate electrode 600mm x 600mm x 3 mm burried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate vertically to a depth not less than 1.5 mtr below ground level connected to the connecting copper strip 20 x 3 mm and including GI pipe 40 mm dia light grade for protection to the extend of 7.5 mtr as earthing lead by means of copper nuts, bolts as per connecting to equipment with provn charcol and salt complete all as per electric plate No 5 of SSR Part-1 including PCC chamber with RCC cover watering arrangement with GI pipe 20 mm dia medium grade and MS funnel, including excavation and earth work and returning, filling in including ramming and removal of surplus soil and testing on completion complete.
Test point terminal block made of gunmetal /phosphorus bronze of size 75x75x25mm drilled and screwed including 3 Nos, 8mm dia 25mm long hex head screw fixed complete all as specified and as directed.
AGRAWAL ASSOCIATES
Veer High Tech Solution
NOEL ENGINEERS
BRITE INDUSTRIES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .