EXECUTIVE ENGINEER (SDW) I
KILOKARI SPS JAL VIHAR LAJPAT NAGAR NEW DELHI-110024
Electrification of different category staff quarters at Jal Vihar Colony.
2022_DJB_227781_1
NOTICE INVITED TENDER_NO_05 (2022-23) EE(SDW) I
Open Tender
Miscellaneous Works
Works
45 days
Jal Vihar Colony.
PLEASE REFER TENDER DOCUMENTS
3 documents required · 3 mandatory
₹500
DJB EMD A/c No. 50448339804 at Indian Bank, Copern
₹15,850
Yes
30 Aug 2022
16 Aug 2022
26 Aug 2022
16 Aug 2022
26 Aug 2022
16 Aug 2022
Electrification of Bunglow No. 1 & 3 Type-V New Duplex type accommodation staff quarters at Jal Vihr Colony as mentioned below:- 1.3.3 Wiring for light point / fan point / exhaust fan point call bell point with 1.5 Sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed conduit, with modular switch, modular plate, suitable size modular box and earthing the point with 1.5 Sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group-C.
1.7/2 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.7.2/2 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire.
1.7.3/2 2 x 4 sq. mm + 1 x 4 sq. mm earth wire
1.7.10/2 4 x 10 sq. mm + 2 x 6 sq. mm earth wire
1.31/7 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A modular type switch, connections, etc. as required.
1.32/7 Supplying and fixing suitable size GI box with modular plate & cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A Modular switch, connections, etc. as required.
1.25/6 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.33/7 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
1.34/7 Supplying and fixing brass batten/ angle holder including connection etc. as required.
1.38/8 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
1.41/8 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
1.44/8 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length upt 30cm with 1.5 Sq. mm FRLS PVC insulated, copper conductor single core etc. as required.
1.50/9 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
2.4/12 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolator). 2.4.1 - 4 way (4+12), double door.
2.10/12 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.1 - Single pole.
2.15.3/13 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.15.3 - 63 A.
Making good the damages required civil work as per requirement.
Complete rewiring work of Jal Vihar Colony Type-II staff quarters Nos. B-30 & C-45 & 33 as per following:- 1.8.1. Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 Sq. mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq. mm FR PVC insulated copper conductor single core cable etc. as required. Group – A.
1.14.1. Wiring for circuit / submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2x1.5 sq. mm + 1x1.5 sq. mm earth wire.
1.14.3. Wiring for circuit / submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2x4 sq. mm + 1x4 sq. mm earth wire.
1.14.4. Wiring for circuit / submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2x6 sq. mm + 1x6 sq. mm earth wire.
1.29. Supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs).
1.30 . Supplying and fixing metal box of 180mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 &15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. required.
1.34. Supplying and fixing brass batten / angle holder including connection etc. as required.
1.25. Supplying and fixing stepped type electronic fan regulator on the existing plate switch box including connections etc. as required.
2.3.1. Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 8 way, Double door.
2.10.1. Supplying and fixing 5 amps to 32 amps rating, 240/415 volts ‘C’ curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole.
2.12.2. Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps.
1.38/8 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
1.41/8 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
1.44/8 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length upt 30cm with 1.5 Sq. mm FRLS PVC insulated, copper conductor single core etc. as required.
1.50/9 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Dismantling the old wiring complete and making good the damage as required in Type-II quarters.
SAI TRADING CORPORATION
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .