Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.0 LAccepted-AOC ROOM NO 145 MASJID WALI GALLI GANESH MURTI NAGAR PART NO 2 COLABA MUMBAI 05 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹26.5 L+₹2.5 L (10.4%)Rejected-Finance ROOM NO 3 GROUND FLOOR NO 3 C BLOCK AMBERNATH | AMBERNATH | THANE | MAHARASHTRA | 421502 | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹31.3 L+₹7.2 L (30.2%)Rejected-Finance ROOM NO 680 GANESH MURTY NAGAR PART NO 03 CAPT PRAKASH PETHE MARG COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹33.5 L+₹9.5 L (39.4%)Rejected-Finance | L4 | Rejected-Finance Being not lowest | |
| 5 | L5₹34.5 L+₹10.5 L (43.6%)Rejected-Finance | L5 | Rejected-Finance Being not lowest |
| Sl No | Description | Qty | Unit | SHRI SAI ENTERPRISES L6 | SHREE SHIV SHANKER ENTERPRISE L4 | Sri Krishna Construction L7 | N.S.ENTERPRISES L5 | CHOUDHARY ELECTRICAL L1 | A.B.CONSTRUCTION L2 | B P ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down electric motor of cap 100 HP by disconnecting elect connection and removing from star/tyre coupler, nuts, bolts, washers for repairing /replacement of unserviceable parts including transportation to workshop and re-installing the same after repair work, complete all as specified and directed by Engineer-in-Charge. | 2 | Each Job | 8,500 ₹17,000 | 4,000 ₹8,000 | 9,000 ₹18,000 | 2,000 ₹4,000 Lowest | 6,500 ₹13,000 | 4,000 ₹8,000 | 3,450 ₹6,900 |
| 2.00 | All as specified in item No. 1 above but motor of cap 40-75 HP. | 6 | Each Job | 7,000 ₹42,000 | 3,200 ₹19,200 | 750 ₹4,500 Lowest | 1,000 ₹6,000 | 4,000 ₹24,000 | 3,500 ₹21,000 | 2,400 ₹14,400 |
| 3.00 | All as specified in item No/ 1 above but motor of cap 15-30 HP. | 10 | Each Job | 5,000 ₹50,000 | 2,500 ₹25,000 | 5,500 ₹55,000 | 800 ₹8,000 Lowest | 2,800 ₹28,000 | 3,000 ₹30,000 | 1,750 ₹17,500 |
| 4.00 | All as specified in item No. 1 above but motor of cap 3 to 12.50 HP. | 12 | Each Job | 4,000 ₹48,000 | 1,600 ₹19,200 | 4,000 ₹48,000 | 500 ₹6,000 Lowest | 2,200 ₹26,400 | 2,000 ₹24,000 | 800 ₹9,600 |
| 5.00 | All as specified in item No. 1 above but motor of cap 0.50 to 3 HP | 12 | Each Job | 2,000 ₹24,000 | 750 ₹9,000 | 2,500 ₹30,000 | 200 ₹2,400 Lowest | 1,200 ₹14,400 | 1,500 ₹18,000 | 500 ₹6,000 |
| 6.00 | Taking down split casing pumping set of cap 100 HP cast iron body by disconnecting from star/tyre coupler, suction/delivery lines, nuts, bolts, washer etc for repair/replacement of unserviceable spare parts including transportation to the workshop and re-installing the same after repair work & testing, complete all as specified and directed by Engineer-in-Charge. | 2 | Each Job | 9,000 ₹18,000 | 3,200 ₹6,400 Lowest | 9,000 ₹18,000 | 4,000 ₹8,000 | 5,000 ₹10,000 | 4,500 ₹9,000 | 3,500 ₹7,000 |
| 7.00 | All as specified in item No. 6 above but pump of cap 40-75 HP. | 6 | Each Job | 7,000 ₹42,000 | 2,500 ₹15,000 | 7,500 ₹45,000 | 3,000 ₹18,000 | 3,500 ₹21,000 | 3,500 ₹21,000 | 2,450 ₹14,700 Lowest |
| 8.00 | All as specified in item No. 6 above but pump of cap 15-30 HP. | 10 | Each Job | 5,000 ₹50,000 | 1,600 ₹16,000 Lowest | 5,500 ₹55,000 | 2,100 ₹21,000 | 2,500 ₹25,000 | 2,800 ₹28,000 | 1,720 ₹17,200 |
| 9.00 | All as specified in item No. 6 above but pump of cap 3 to 12.50 HP. | 12 | Each Job | 4,000 ₹48,000 | 1,600 ₹19,200 | 4,000 ₹48,000 | 1,400 ₹16,800 | 2,200 ₹26,400 | 2,200 ₹26,400 | 700 ₹8,400 Lowest |
| 10.00 | All as specified in item No. 6 above but motor of cap 0.50 to 3 HP. | 12 | Each Job | 2,000 ₹24,000 | 750 ₹9,000 | 2,500 ₹30,000 | 900 ₹10,800 | 1,200 ₹14,400 | 1,500 ₹18,000 | 450 ₹5,400 Lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
27 Dec 2025, 6:00 pmClosed
Kameshwar Prasad, IDSE, EE
GE(West), Colaba, Mumbai - 400 005
REPAIRS TO ELECTRIC DRIVEN PUMP SETS, MOTORS OF WATER SUPPLY SYSTEM INCLUDING CONNECTED ITEMS OF PUMP HOUSE UNDER GE (WEST) COLABA, MUMBAI
2025_MES_743352_1
8165/E8
Open Tender
Civil Works
Item Rate
180 days
GE(West), Colaba
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (W) Colaba, Mumbai
₹80,000
Yes
5 Feb 2026
5 Dec 2025
29 Dec 2025
5 Dec 2025
27 Dec 2025
20 Dec 2025
Amount
Taking down electric motor of cap 100 HP by disconnecting elect connection and removing from star/tyre coupler, nuts, bolts, washers for repairing /replacement of unserviceable parts including transportation to workshop and re-installing the same after repair work, complete all as specified and directed by Engineer-in-Charge.
All as specified in item No. 1 above but motor of cap 40-75 HP.
All as specified in item No/ 1 above but motor of cap 15-30 HP.
All as specified in item No. 1 above but motor of cap 3 to 12.50 HP.
All as specified in item No. 1 above but motor of cap 0.50 to 3 HP
Taking down split casing pumping set of cap 100 HP cast iron body by disconnecting from star/tyre coupler, suction/delivery lines, nuts, bolts, washer etc for repair/replacement of unserviceable spare parts including transportation to the workshop and re-installing the same after repair work & testing, complete all as specified and directed by Engineer-in-Charge.
All as specified in item No. 6 above but pump of cap 40-75 HP.
All as specified in item No. 6 above but pump of cap 15-30 HP.
All as specified in item No. 6 above but pump of cap 3 to 12.50 HP.
All as specified in item No. 6 above but motor of cap 0.50 to 3 HP.
Opening the electric induction motor and taking out the unsv winding wire complete and cleaning the slots, rewinding the motor with super enamalled copper winding wire of existing gauge including all other insulating material of cap 100 HP, complete all as specified and directed by Engineer-in-Charge.
All as specified in item No. 11 above but motor of cap 40-75 HP.
All as specified in item No. 11 above but motor of cap 15-30 HP.
All as specified in item No. 11 above but motor of cap 3 to 12.50 HP.
All as specified in item No. 11 above but motor of cap 0.50 to 3 HP. Note for Ser item No 11 to 15:- Rates deemed to be included for decoupled and coupling pump with motor.
Supply and fixing bearing No 3309 of make SKF.
All as per item No.16 but bearing No 6207.
All as per item No.16 but bearing No 6208.
All as per item No.16 but bearing No 6306.
All as per item No.16 but bearing No 6309.
All as per item No.16 but bearing No 6308.
All as per item No.16 but bearing No 6305.
All as per item No.16 but bearing No NU 314 ECM.
All as per item No. 16 but bearing No 6312.
All as per item No. 16 but bearing No 6313.
All as per item No. 16 but bearing No 6310.
M & L in repair replacement of CI / rubber coupling Make : FENNER FINOLEX of size L-226 to L-300 including testing.
All as per item No. 27 above but for L-150.
All as per item No. 27 above but for L-225.
S&F in repair pressure gauge 150 mm dia range 0-10 kg/Sqcm, Make : FIEBIG or equivalent Note:- Rate quoted deemed to be included for providing adopter/Ferrule/check nut, pipe etc required for fixing of pressure guage.
S&F in repair MS Star coupling suitable for 100 HP pumps at various installations.
All as per item No. 31 above but suitable for 40 to 75 HP.
All as per item No. 31 above but suitable for 30/10HP.
S&F in repair main contactor ML 4, 3 Pole of Make L&T or equivalent.
All as per items No. 34 but ML 3, 3 Pole of Make L&T or equivalent.
All as per items No. 34 but MNX 70, 3 Pole .
S&F in repair Thermal over load relay ML type 14-32 A.
S&F in repair Thermal over load relay MN type 30-50 A.
S&F in repair Thermal over load relay MN type 50-100A.
S&F in repair MCCB's 3 Phase (TP) 400A 50Hz, 50 KA fixed in existing panel board as per site required.
S&F in repair MCCB's 3 Phase (TP) 200A 50Hz, 36 KA fixed in existing panel board as per site required.
S&F in repair MCCB's 3 Phase (TP) 100A 50Hz, 30 KA fixed in existing panel board as per site required.
S&F in repair MCCB's 3 Phase (TP) 63A 50Hz, 30 KA fixed in existing panel board as per site required.
Scrapping old paint from motor pump of capacity 75/100 HP, coupling guard MS common base frame and painting two coats of synthetic enamel paint of approved quality and colour all as follows, complete all as specified and directed by Engineer-in-charge. (a) Motor pump - Grey colour (b) Coupling guard and motor air grill red colour (c) Common base frame - black (d) Suction line & delivery line - blue colour with arrow marks (in side pump house) (e) fixing and making name plate of each pump set and writing SM/MES No 25mm, capacity etcin white colour on plate
All as per item No. 44 but of capacity 40 to 60 HP.
All as per item No. 44 but of capacity 20/10/5/3 HP.
M & L for replacement of unserviceable shaft sleeves of MS for 70 HP cap pump sets
All as per item No. 47 but of capacity Suitable for 40 HP pump set.
Supply and fixing Battery 12 V 180 AH model No XP 1800 of exide or equivalent.
Supply and fixing in repair electronic timer ST 100 3 -30 Sec.
Supply and fixing in repair single phase preventer VSP 2 of make Minilec or equivalent.
Supply and fixing in repair phase failure relay VMR 2 of make Minilec or equivalent.
M & L for replacement of unserviceable CI impeller as per existing suitable for 60/75 HP capacity pump sets :-
All as per item No. 53 but of Suitable for 30 HP capcity pump set.
All as per item No. 53 but of Suitable for 20 HP capacity pump set.
All as per item No. 53 but of Suitable for 15 HP capacity pump set.
All as per item No. 53 but of Suitable for 10 HP capacity pump set.
Demolition of cement concrete (un-reinforced) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) and debris out side MD land, complete all as specified and directed.
M&L cement concrete 1:2:4, type B-0 (using 20mm graded stone aggregate) as in support of, foundation and hard standing finishing even and fair without using extra cement, complete all as specified and directed.
M & L for rendering 10 mm thick cement plaster 1:4 on fair faces of bricks work or concrete surface for tiles, complete all as specified and directed.
M & L fixed in repair for rolled mild steel Fe 410-W (Gde E 250 type B) Joist, channel, angle or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) including welding, making holes for fixing bolts, painting etc, complete all as directed by Engineer-in-Charge.
S&F New MS ERW pipe 'C' class 150 mm dia confirming to IS 1239 with necessary fittings conforming to IS 1239 such as flanges, nuts bolts, gaskets, X Ray quality welding, testing including painting complete & testing hydraulic pressure 10.50 Kg/Sqcm complete including Dismantling/taking out old unserviceable pipe, complete all as specified and directed.
All as per item No. 62 above but 100 mm dia.
All as per item No. 62 above but 80 mm dia.
Supply and fix in repair foot valve, flanged ends, swing type operation with rubber seat of size 80mm dia including necessary fittings such as nuts, bolts, washers, complete all as specified and as directed by Engineer-in-Charge.
All as specified in item No. 65 above but 100 mm dia.
All as specified in item No. 65 above but 150 mm dia.
All as specified in item No. 65 above but 300 mm dia.
M & L, testing Compact Motor Protection MM 10 relay for Medium & Large Size Motors Relay a microprocessor based Motor Protection Relay with 4 digits LED Display, Protections for Thermal Overload with Warning , Short Circuit, Under Current, Unbalance, Phase Loss, Phase Sequence Reversal ,Earth Fault , Prolong Starting, Locked Rotor and Features of 4 Digit LED display, Measurement of RYB, Zero Sequence current and Thermal capacity, Separate LED’s for indication of Motor operational, Trip & Thermal OL/ pre-alarm, 2 nos ,1 no. Programmable Binary input for remote operation. of C/O output contacts. status,Programmable thermal OL time constant right from 1 sec to 40 sec,configured for operations of Trip Reset, Instant Tripping, Relay testing facility, Trip data recording Fault current or cause of last trip is displayed including suitable size current transformer for functioning motor pump, complete all as specified and directed by Engineer in charge.
Earthing complete with galvanized steel earth plate electrode 600 x 600 mm, thickness not less than 6mm buried directly in ground (earth pit not less than 2.25 mtr deep Below ground level) with top edge of the plate n.less than 1.5 mtr below ground level, connected to galvanized earth lead 25 x 3.15 mm dia by means of bolts, nuts, check nuts and washers of GI including PCC pit in PCC 1:2:4 type B-1 angle iron 40x40x3mm frame with pre-cast RCC 1:2:4 type B-1 cover with XPM weight n.less than 4kg/sqm and 6mm dia bar handle, excavation and earth work in any type of soil, charcoal, dust and common salt light grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 15mm bore 05 mtr long and earth wire up to main earthing of pole complete all as shown in Electric Plate No 3 of SSR 2009 Part-I, all as specified and testing on completion.
Supply and fixing in repair monoblock 1 HP 240 Volts single phase suitable for shower and lifting of water, complete all as specified and directed.
supply and fixing in repair automatic pump controller sensor switch 240 Volts single phase suitable for shower and lifting of water, complete all as specified and directed.
Supply and fix Mechanical butterfly valve confirming to IS 13095:1991, CI body, PN 1.6 ISI mark, with suitable size flanged end, socket, elbow etc of functioning of valve for 80 mm bore pipe fixed with GI nut, bolts, washers, rubber gasket etc including dismantling/taking out old, unserviceable valve complete all as specified and directed.
All as per item No. 73 but 150mm size.
All as per item No. 73 but 300mm size.
S&F in repair shed water proof 2.5 fit x 2.5 fit x 2.5 fit to protect motor from water including 2 fit PCC from ground, 2mm sheet and 50x50x5mm angle iron frame, wooden frame for fixing monoblock pump 0.5 HP and sensor with suitable size locking arrangement with lock and key, nuts bolts, union, pipe for fixing connecting pump with PVC copper flexible cable and necessary fixing arrangement, complete all as specified and directed.
M & L carrying out maintenance of pump/motor 0.5 HP to 100 HP set with connections/ disconnections fittings like as elbow, socket, union, pipe by tightening and minor repair / water leakage by pump , attending fault of pump/motor , as required at site to cater the satisfaction of Engr-in-Charge as assigned, with providing suitable size all minor spare parts i.e. washer, bush, pump gland, gland cover, gland stone, gasket, packing sheet, water seal, pump set cover plate, electric connection box, oil seal nut bolt, etc., complete all as specified and directed.
Supply and fixing in repair auxiliary relay, complete all as specified and directed.
Supply and fixing in repair NO NC switch, complete all as specified and directed.
Taking down and reconnection, testing of electric motor / pump of cap 10 to 100 HP by disconnecting elect / water connection and removing from star/tyre coupler, nuts, bolts, washers for re-foundation of pump and motor as directed, including re-installing the same after foundation and demolition of foundation with suitable size elbow, socket, union, pipe, washer, bush, pump gland, gasket, packing sheet, pump set cover plate, nut bolt of any shape and size etc for Woking of pump and motor, complete all as specified and directed by Engineer-in-Charge. Note:- (a) The PCC and cross arms will be measured separately again above items. (b) The rates quoted shall be deemed for any type T & P.
Fixing and testing only APS dosing system including PVC pipe, tab, socket, elbow, stop valve 15mm, electric connection and branch connection, PCC foundation etc as required for fixing dosing system, complete all as specified and directed.
M & L in repair of Cooling fan cover suitable for 3 to 100 HP, complete all as specified and directed.
M & L in repair of Cooling fan aluminium fan /Plastic fan suitable for 3 to 100 HP, complete all as specified and directed.
Supply and fixing First Aid box kit including 10 item of first aid, complete all as specified and directed.
Supply and fix water meter (multijet meter, domestic type) nominal size 50 mm class B magnetic drive as per IS 779: 1994 including cutting threading fixture and fitting and tested and approved by BMC department etc including taking down old one, complete all as specified and directed.
M & L for DG set name plate and writing SM/MES No 25mm, capacity, date of installation etc in white colour on plate and fixing on DG /Room including taking down old one, complete all as specified and directed.
M & L for layout diagram of water supply distribution system of Pump House in white colour on plate and fixing in Pump Room including taking down old one, complete all as specified and directed. Note : draft diagram provided by MES.
Supply and laying insulated Electrical matting class 2 proof voltage tested upto 20KV, 10mm thickness of size 1.00 metre (wide) 2 metre length with one side fabric and other side plane finish as per IEC 61111 including taking out old unserviceable rubber matting and removing from site of work, complete all as specified and directed.
Supply and install in repairs AFO (Auto fire off) fire extinguisher ball 150 mm dia (standard orange) with stand, complete all as specified and directed.
S&F Transciever automation for the water level Detector and controller with the feature mentioned here under comprising of following: (a) S& F Transciever must communicate at a distance of 3km -5kms range with each module must have the LORA/GSM or suitable communication module ( long range antenna) must work above 500 mhz and each module shall have a processor module connecting to the sensor, with the facility that the processor module to sense the low level (10-20%) and high level of the water level (90-100%) so as to raise the hooter and communicate with the other hardware modules with antennas (b) S&F transducer module wiring through the D sub connectors (MIL industrial grade are to be used). All the wiring must be shielded optical co-axial cable for connection to flasher and hooter. Rates quoted are deemed to be included for suitable flasher and hooter. (c) S&F Hooter 12V/5 Amp with suitable converter or hooter suitable for 230V AC Supply must be provided standard suspended rust proof stand Note: All the NPT cable glands must be used for the sensor interface and MCB controller board. (d) S&F 12V flasher with suitable converter or flasher suitable for 230V AC Supply connected with suitable 3 Core Co axial cable suitably crimped nicomatic connector. Note: All the cables to be drawn through suitable medium grade conduit suirtably fixed with clamps. (e) S &F of LED display board with superior night vision display to be provided at the receiver station. (f) S&F controller Board confirming to IP 65 protection 3D printed with EMI/EMC compatible FE 32 material for the enclosure. Note: (a) One transmitter for over Head Tank and one receiver for Pump House . (b) Contractor has to visit the site before execution. Any cable required deemed to be included in quoted rate. No extra payment will be made on this account.
S&F in repairs 2000 ltr capacity rotational moulded polyethelene water storage tank cynlindrical vertical with closed top triple layered, white colour (inside & outside of tank), hoisted and fixed in position including float valve of suitable size, complete all as specified and directed.
S&F in repairs 1000 ltr capacity rotational moulded polyethelene water storage tank cynlindrical vertical with closed top triple layered, white colour (inside & outside of tank), hoisted and fixed in position including float valve of suitable size, complete all as specified and directed.
S&F in repairs 500 ltr capacity rotational moulded polyethelene water storage tank cynlindrical vertical with closed top tripled layered, white colour (inside & outside of tank), hoisted and fixed in position including float valve of suitable size, complete all as specified and directed.
S & F in repair sprinkler nozzle 15mm dia suitable water fountain, complete all as specified and directed.
S&F in repairs 4000 ltr capacity rotational moulded polyethelene water storage tank cynlindrical vertical with closed top triple layered, white colour (inside & outside of tank), hoisted and fixed in position including float valve of suitable size, complete all as specified and directed.
Supply and fix Air release valve ISI mark, flanged end for 80/100 mm bore pipe fixed with GI nut, bolts, washers, rubber gasket etc including dismantling/taking out old, unserviceable valve, complete all as specified and directed.
S & F UPVC pipe 20mm dia, complete all as specified and directed.
A.B.CONSTRUCTION (BID ID -3509514)
B P ENTERPRISES (BID ID -3509643)
SHREE SHIV SHANKER ENTERPRISE (BID ID -3509898)
N.S.ENTERPRISES (BID ID -3504333)
SHRI SAI ENTERPRISES (BID ID -3509366)
Sri Krishna Construction (BID ID -3509905)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
8165TenderPages.pdf
Tender Documents • 1.35 MB
BOQ_832367.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .