Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Quoted Rate | |
| 2 | L2₹5.7 L+₹96,390 (20.2%)Rejected-AOC | L2 | Rejected-AOC Other than Lowest Quoted Rate | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 5 | Not Admitted-Fee/PreQual/Technical VEENA SADAN PLOT NO 63 VARANGAON ROAD SUNDAR NAGAR BHUSAWAL 425201 | BHUSAWAL | JALGAON | MAHARASHTRA | 425201 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
2 Mar 2021, 6:00 pmClosed
Shri Ravinder Kumar AGE CONTRACTS
GE (S) Ahmednagar, Military Engineer Services, Ahmednagar- 414002
Repair/replacement of cooling appliances and DG sets at Mil Stn Bhusawal under GE (S) Ahmednagar
2021_MES_418022_1
8770/E8
Open Tender
Miscellaneous Works
Item Rate
240 days
Bhusawal
Class E cat c (i)
8 documents required · 8 mandatory
₹500
Garrison Engineer (S) Ahmednagar
₹10,000
Yes
9 Mar 2021
2 Feb 2021
4 Mar 2021
2 Feb 2021
2 Mar 2021
16 Feb 2021
2 Feb 2021 - 8 Feb 2021
Amount
Maintenance and servicing of diesel engine driven generating set of capacitiy 200 KVA, 415 Volt-01 No installed at Pump house No 2 by carrying out first hand repairs, cleaning of engine, cleaning of fuel tank, cleaning of duct, alternator etc from time to time (one time in each month) complete and keeping DG set fully serviceable condition all as spd and directed including replacement of the following parts where required :- (a) Replacement of lubricant oil . (b) Replacement of lubricating oil filter element O ring. (c) Replacing of fuel filter element. (d) Replacing of coolant. (e) Replacing of Governer oil. (f) Replacing of CR Element. Note : Spare part, coolant, lubricant oil and distilled water will be measured and paid separately under relevant items.
Maintenance and servicing of diesel engine driven generating set of capacitiy 25 KVA, 415 Volt-01 No installed at Sub Stn No 1 by carrying out first hand repairs, cleaning of engine, cleaning of fuel tank, alternator etc for time to time (one time in each month) complete and keeping DG set fully serviceable condition all as spd and directed including replacement of the following parts where required :- (a) Replacement of lubricant oil. (b) Replacement of lubricating oil filter element O ring. (c) Replacing of fuel filter element. (d) Replacing of coolant. (e) Replacing of Governer oil. (f) Replacing of CR Element. Note : Spare part, coolant, oil and distilled water will be measured and paid separately under relevant items.
Radiator coolant concentrate for two No DG Sets, filled complete all as specified and directed. Make:- K- COOL SUPER PLUS/ CASTROL
Motor winding of pump for radiator for DG set 200 KVA ,415 volts,with suitable wire as per existing, complete all as specified and directed. Make: Greaves or as existing at site
Motor winding of pump for radiator for DG set 25 KVA ,415 volts with suitable wire as per existing, complete all as specified and directed. Make: Greaves or as existing at site
Cylinder head assembly including liner complete for 200 KVA DG Set, fixed in replacement complete all as specified and directed.
Piston set with rings complete for 200 KVA DG Set, fixed in replacemet complete all as specified and directed.
Rubber hose pipe with clamp complete of suitable sizes for the engine of 200 KVA DG Set, fixed in replacement complete all as directed. Make : Greaves or as existing at site
Rubber hose pipe with clamp complete of suitable sizes for the engine of 25 KVA DG Set, fixed in replacement complete all as directed. Make : Kirloskar or as existing at site
Air filter complete of suitable sizes for the 200 KVA , DG Set, fixed in replacement complete all as directed. Make : Greaves or as existing at site
Air filter complete of suitable sizes for the 25 KVA , DG Set fixed in replacement complete all as specified and directed. Make : Kirloskar
Auto control wiring with PVC insulated copper wire multistranded of 4 Sqmm 2 core cable for 200 KVA DG Set with all accessories,as in replacement complete all as directed.
Insulation of duct tar sheet for 200 KVA DG sets as in replacementcomplete all as specified and directed.
Battery connection copper lead with suitable size of lugs ,fixed in replacement with 200 KVA DG set, 415 Volts complete all as specified and directed.
Battery connection copper lead with suitable size of lugs ,fixed in replacement with 25 KVA DG set, 415 Volts complete all as spd and directed.
Flexible fuel pipe (from feed pump to fuel filter, fuel filter to fuel pump and pre-filter to tank unit) of suitable size with banzo washers for DG Set 200 KVA Make : Greaves, fixed in replacement complete all as directed.
Flexible fuel pipe (from Feed pump to fuel filter, fuel filter to fuel pump and pre-filter to tank unit) of suitable size with banzo washers for DG Set 25 KVA Make : Kirloskar, fixed in replacement complete all as directed.
V' belt for dynamo / alternator of suitable sizes for DG Set 200 KVA Make : Greaves, fixed in replacement complete all as directed.
V' belt for dynamo / alternator of suitable sizes for DG Set 25 KVA Make : Kirloskar, fixed in replacement complete all as directed.
Auto control wiring with PVC insulated copper wire multistranded of 4 Sqmm 2 core cable for 25 KVA with all accessories, as in replacement complete all as directed.
Alternator slip rings with bearings for 200 KVA DG Set, fixed in replacement complete all as directed.
Alternator slip rings with bearings for 25 KVA DG Set, fixed in replacement complete all as directed.
Exhaust manifold cum silencer with clip for 25 KVA DG Set, fixed in replacement complete all as specified and directed.
Normal spare parts i.e washer, spring, O-Ring, bushes, disc plug, piston ring etc for 2 No DG sets as required at the time of maintenance complete all as directed.
AC syncronous motor, 230 Volt with RC network of 25 KVA Voltage stabilizer fixed in replacement complete all as specified and directed .
Auxiliary transformer primary (230 V AC), secondary (15-0-15 Volt ac) of 25 KVA voltage stabilizer fixed in replacement complete all as specified and directed.
Bush assembly of 25 KVA voltage stabilizer fixed in replacement complete all as specified and directed.
Control card of 25 KVA voltage stabilizer fixed in replacement complete all as specified and directed.
Ralay -18V/1 CO of 25 KVA voltage stabilizer in fixed replacement complete all as specidied and directed.
Starting capacitor of capacity 80/100 mfd, 440 volt AC suitable for window type air conditor 1.5 ton capacity,fixed in replacement complete all as specified and directed. Make TESLA EPCOS, siemens, Shriram.
Running capacitor of capacity 36 mfd, 440 volt AC suitable for window type air conditor 1. 5 ton capacity,fixed in replacement complete all as specified and directed. Make TESLA EPCOS, siemens, Shriram.
Controls panels of window type AC, 1.5/2 Ton capacity, fixed in replacement complete all as specified and directed.
Blower motor complete with fan blade, 230 volts, suitable for 1.5 / 2 TR window type AC, any make as per existing, fixed in replacement complete all as directed.
Disconnecting, cutting and taking out unserviceable sealed unit compressor of Window type Air conditioner 1.5 Ton capacity any make & model and supply and fixing new compressor of same make as existing for Window type air conditioner 1.5 Ton capacity soldering, welding, brazing as required including charging of refrigerant gas and oil in the exchanged compressor, making electric & mechanical connections of air conditioner at site and testing on load complete all as specified and directed.
Air inlet and outlet grill for window type AC 1.5/ 2 Ton capacity fixed in replacement complete all as specified and directed.
58 S&F Oscillating motor for indoor unit of Split AC suitable for LG, Samsung, Voltas, B/str /Shriram usha of Cap 1.5 Ton/2 Ton
Disconnecting, cutting and taking out unserviceable sealed unit compressor of split type Air conditioner 1.5 Ton capacity any make & model and supply and fixing new compressor of same make as existing for split type air conditioner 1.5 Ton capacity soldering, welding, brazing as required including charging of refrigerant gas and oil in the exchanged compressor, making electric & mechanical connections of air conditioner at site and testing on load complete all as specified and directed.
Fan motor for indoor unit of Split type AC Cap 1.5 Ton suitable of Make LG, Samsang. Voltas, Shriram Usha, fixed in replacement, complete all as spd and directed.
Fan motor capacitor, compressor capacitor of 1.5 Ton Split type AC of Make LG, Sumsang, Voltas or eqvt , fixed in replacement, complete all specified and directed.
Evaporator coil assembly for indoor unit for 1.5 ton AC, fixed in replacement, complete all as specified and directed. Make: Videocon, Hitachi, Sumsung or equivalent.
Flexible cord PVC insulated and sheathed 650/1100 V wire 3 core 4 sqmm copper conductor, fixed in replacement complete all as specified and directed. Make- Polycab / Finolex or equivalent
Control PCB circuit plate with display PCB for split type AC 1.5 ton capacity, fixed in replacement complete all as specified and directed. Make- LG.Samsung, Videocon or equivalent.
AC blower with fan motor for indoor unit of Split type AC Cap 1.5 Ton of Make Hitachi / Voltas / Micromax, fixed in replacement, complete all as specified and directed.
Disconnecting water cooler any size from main power and taking out for carrying out necessary service / maintanace and checking serviceability of compressors, fan motor, capacitor, thermostate switches, gas leakage, push taps, fan blades, relays, over load protectors, condensor coil and any other spares required to make the water cooler functional and fixing in original /existing position complete all as specified and directed. (Spare parts to be replaced shall be measured and paid for separately under respective item.)
Disconnecting, cutting and taking out unserviceable sealed unit compressor of water cooler storage type 40-80 ltrs capacity any make & model and supply and fixing compressor of same make for water cooler storage type 40-80 ltrs capacity soldering, welding, brazing as required including charging of refrigerant gas and oil in the exchanged compressor,making electric & mechanical connections and water connection, installation of water cooler at site and testing on load complete all as spd and directed.
Repair/maint of water cooler 40/60/80 ltrs capacity, dismantling required parts for general cleaning, scraping with emery / sandpaper, filling of putty wherever required and painting with one coat of redoxide primer and two coats of synthetic enamel paint of approved colour complete all as specified and directed.
Fan blade made out of aluminium, suitable for water cooler 40/60/80/120 ltrs capacity, fixed in replacement, complete all as specified and directed..
Thermostat switch suitable for water cooler including knob plate and screw, fixed in replacement complete all as specified and directed. Make: INDFOS/RANUTROL/ SRIRRAM/USHA/HI TECH.
Fan motor 1/35 HP, 230 Volts single phase, 1440 RPM complete suitable for water cooler, fixed in replacement complete all as specified and directed. Make: AMERICAN UNIVERSAL/USHA/AIR MASTER/COOLER MASTER.
Running capacitor 10 mfd suitable for compressor of water cooler of any capacity,fixed in replacement complete all as specified and directed. Make EPCOS/KEILL/ Seimens
Float valve PVC 15 mm bore with ball ( short rod), fixed in replacement complete all as specified and directed. Make- Prayag or equivalent as approved by GE
Supply and charging gas R22/R-34 for water cooler/refrigerator/AC for filling/topup including testing complete all as specified and directed.
Repairs/servicing of Refrigerator 165/310 lts capacity including taking down of unserviceable parts such as cooling coil, freezer chest and other parts, cleaning internally and externally complete including replacement of unserviceable parts such as capillary, stainer, theromstat, relay, gas charging and other parts etc all complete as specified.(Spares/parts to be replaced shall be measured and paid for separately under respective item).
Repairs to voltage stabilizer 5 KVA of any make including replacement of wornt out parts such as volt meter, auto transformer, circuit plate, step-up, step-down relay etc complete all as specified and directed.
Disconnecting, cutting and taking out unserviceable sealed unit compressor of Refrigerator upto 165 capacity any make & model and supply and fixing company repaired compressor of same make for Refrigerator upto 165 Ltrs capacity soldering, welding, brazing as required including gas charging in the compressor, making electric & mechanical connections at site and testing on load complete all as specified and directed.
All as per serial item No. 55 Here-in-before but for refrigerator of capacity 310 litres
Thermostat switch with defrosting arrangement suitable for Refrigerator any capacity including knob plate and screw, fixed in replacement complete all as specified and directed. Make: INDFOS/ RANUTROL/ HONEY WELL/HI TECH.
Sedimentation filter cartridge for Kent RO capacity of 25 ltrs/hrs, ixed in replacement complete all as specified and directed.
Booster pumps for Kent RO capacity of 25 ltrs/hrs, fixed in replacement complete all as specified and directed.
Adaptors and SMPS for Kent RO capacity of 25/35 ltrs/hrs, fixed in replacement complete all as specified and directed.
Activated carbon block filter membrane for for Kent RO capacity of 25/35 ltrs/hrs, fixed in replacement complete all as specified and directed.
UF & Post carbon filter cartridge for for Kent RO capacity of 25/35 ltrs/hrs, fixed in replacement complete all as specified and directed.
Repairs/maintenance of Deep Freezer 300 lts capacity including taking down of unserviceable parts such as cooling coil, freezer chest and other parts, cleaning internally and externally complete replacement of unserviceable parts such as capillary, stainer, theromstat, relay, gas charging and other parts etc all complete as specified and directed.
Disconnecting, cutting and taking out unserviceable sealed unit compressor of deep freezer 300 litres capacity any make & model and supply and fixing company repaired compressor of same make and model for deep freezer 300 Ltrs capacity soldering, welding, brazing as required including gas charging in the compressor, making electric & mechanical connections at site and testing on load complete all as specified and directed.
Repairs/Maintenance and servicing of Desert cooler, dismantling of Fan motor, pump, diverter, fan blade, water pipe , side panels, scrapping of rusted inside of tank & body, Painting of all dismantled items inside with one coat of redoxide metal primer and one coat of synthetic enamel paint of approved quality, reassembling fixing of woodwool with wiremesh etc complete and testing complete all as specified and directed.(Spares replaced except wood wool shall be measured and paid for separately).
Dismantling of unserviceable cooler fan motor from desert cooler including rewinding of fan motor with super enamelled copper winding wire of correct size and gauge including insulating materials such as insulating paper varnishing and reassembling and testing complete all as specified and directed.
Fan motor for Desert cooler 1400 RPM, 450 mm sweep 1/8 HP, single phase double speed complete with frame and blade, conforming to relevant IS, fixed in replacement, complete all as directed. Make: AUE/Usha/Kaitan
Best quality of wood wool suitable for desert coolers complete all as specified and directed.
PVC pipe 1/2" dia H/D for desert cooler for internal water connections as in replacement complete all as specified and directed.
GI wire mesh 15 mm x 15 mm appreature of suitable gauge for desert cooler for fixing of wood wool complete all as specified and directed.
Condenser 4 Mfd capacitor, 230 V AC, fixed in replacement complete all as specified and directed. Make: EPCOS/Siemens/Usha.
Water circulating pump motor 1/26 HP (Tullu pump) 230 V, single phase 1440 RPM suitable for any type of air cooler/desert cooler fixed complete all as directed. Make :- Khaitan/Usha/Crompton.
Galvanised irin Air Diverter grill 20" size for desert coolers, fixed in replacement complete all as specified and directed.
Flexible cord PVC insulated and sheathed, 3 core flexible with copper conductor of size 2.5 sqmm, fixed in replacement complete all as specified and directed. Make:- Polycab, Anchor, Finolex
Bottom water tray / tank for desert coolers of standard size and 22 gauge as per sample, fixed in replacement complete all as directed.
Repair of mini central AC system with the following parts replacement including cleaning:- (a) Water storage body cleaning. (b) Remove and refixing of woodwool of AC system body. (c) Replacement of submersible motor 1 Phase, 230 V, 35 W capacity and lifting head 2.5 mtr. (d) Replacement of existing water storage body complete including painting with two coats of synthetic enamelled paint over a coat of redoxide primer complete all as directed.
Battery 12 Volt, 180AH for 200 KVA DG Set fixed in replacement complete all as specified and directed. Make- Exide or eqvt as approved by GE
Battery 12 Volt, 88AH for 25 KVA DG Set fixed in replacement complete all as specified and directed. Make- Exide or eqvt as approved by GE
Bhirud Electric Stores
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .