Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹20,500
Closing Date
17 Aug 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
S.E EUDC Office sec-18 Noida
Systems Strengthening Works
2023_PVVNL_826412_1
Systems Strengthening Works
Open Tender
Electrical Works
Item Rate
45 days
S.E EUDC Office sec-18 Noida
Attached in DOC
2 documents required · 2 mandatory
₹3,540
S.E., EUDC-II Noida
₹20,500
23 Aug 2023
3 Aug 2023
17 Aug 2023
3 Aug 2023
17 Aug 2023
3 Aug 2023
Amount
Safe carriage of following stock material, from any of the Store Center of PVVNL to work site including Loading from Store and safe unloading at site for Item No. 1 to 6
ST POLE 11 Mtr. Long SP - 55
LT Cable 3.5x240sqmm
LT XLPE Cable Alu. 1x400sqmm
ACSR Dog Conductor
Line Accessories ( 11 KV Pin Insulator with Pin -60 Nos., X-Arms for 11KV Line - 16Kg., LT Cable Box ST Through for 3.5x240sqmm - 10 Nos., 11 KV Disc Insulator with fittings - 25 Nos., MS Channel 100x50mm - 450Kg., Stay Set Complete - 10 Nos., Guarding wire 10SWG - 50Kg., Guarding Wire 8 SWG - 15Kg., Angle for Guarding - 130Kg. or any other material releated to work etc.)
Errection of Following material as per RESPO.
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 65x8mm, G.I.Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, 'E' bracket 75x10mm, and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I.Angle 65x65x6mm. The work includes cutting holes and providing G.I.Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule. Double Pole Structures (a) 11M Long STP, SP-55 Round Pole
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 'F' bracket 75x10mm, G.I.Nut bolt & washer, Stone Pad Al. Binding wire and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as an fabrication work if required. Single Pole (a) 11M Long STP, SP-55 Round Pole
Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming. Single Pole and Double Pole (a) 11M Long STP, SP-55 Round Pole
Grouting of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:3:6 cement, sand, 20mm Stone grift) as per drg. Including back filling of soil and proper ramming etc.
Fixing, tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing, including providing & fixing of Stay Insulators of 11KV and Stay Clamps.
Laying, spreading, lifting and final sagging of 3 phases ACSR Dog conductor in accordance with Line chart includidng binding and fixing of all accessories in 03Nos. Conductor in parallel as per site requirement.
Making Jumpers on Sectional Pole, by providing & fixing of P.G.Clamps of proper sizes, suitable for Dog Conductor as per site requirement.
Guarding between two poles like single poles, double poles, four poles, etc. to guard L.T., 11KV Line, telephone line and river crossing, road crossing etc. with G.I.wire No.10SWG - 50Kg, G.I.wire No.8SWG-15Kg. including cutting with fabrication and fixing of G.I.Guarding angle 75x75x6mm with Providing & fixing G.I.clamps size 75x10mm, G.I.Turn buckle, G.I.Eye bolt, nut bolts & washer etc, as per drawing and site requirement.
Providing and Driving of MS earth rod of size 20x2500 mm in earth and jointing through G.I. wire of 6 SWG between support and earth electrode by providing proper size of bolts and nuts for pole earthing. Supply Erection, fixing, grouting of stay rod in cement, sand and brick ballast in ration 1:4:8 in Block 600*600*300 mm with binding & nuzzling including providing & fixing of stay insulator complete in all respect with grouting. (All Work and Material in the scope of Contractor)
Excavation of earth of size (0.5x0.75x260)m for T/F for laying of 32 mm dia M.S. Round and 50x6mm size G.I. strip and refilling & ramming of the same earth into the trenches after completion of work.
Providing & Erection of Chemical pipe earthing including electrode, chemical with 3mtr. Long, 80mm dia and 3mm thick G.I. Pipe & G.I. strip of 25x3mm must be used for T/F ACB (All required matrials provided/Supply by the contractor own his cost).
Fixing and Comissioning of 33KV Straight Through Box suitable for LT 3.5x240sqmm XLPE Cable with the help of Jointer with digging and refill of kacha/pakka hot mix road and complete connections in all respect. (Straight Through Box shall be provided by the deptt. and work, material related to work in the scope of contractor).
Fixing of 11KV Pin Insulator with Pin at different locations as per RESPO.
Fixing of X-Arm for 11 KV Line at different locations as per RESPO.
Laying of LT 3.5x240 sqmm cable after digging trench for laying cable and refilling of trench including connections at both ends after providing and crimping of lugs of proper size for completion of work and laying brick over & both sides of L.T. cable after digging trench of 0.3 m wide & 0.5 m depth and providing and wearing 75 mm dia G.I. pipe of 2.5 M length over L.T. Cable complete in all respect.
Laying of LT XLPE Alu. 1x400 sqmm cable after digging trench for laying cable and refilling of trench including connections at both ends after providing and crimping of lugs of proper size for completion of work and laying brick over & both sides of L.T. cable after digging trench of 0.3 m wide & 0.5 m depth and providing and wearing 75 mm dia G.I. pipe of 2.5 M length over L.T. Cable complete in all respect.
Fixing of 11KV Disc Insulator with fittings at different locations as per RESPO.
Fixing of MS Channel 100x50mm at different locations as per RESPO.
Fixing for Angle at Pole for Guarding at different locations.
making of plinth of Air Curcuit Breaker as per RESPO Drawing, as per PVVNL guidline and site requirements as per following Excavation of earth, Grouting of structure in C.C.ratio1:4:8, Erection of ACB structure in proper alighment., Making plinth by C.C.ratio1:3:6 and 12mm thick plastering on plinth in ratio 1:4
Supply and Fixing of Alu. Crimping Lug 240sqmm at different locations as per RESPO.
Supply and Fixing of MS Holding Clamp at different locations as per RESPO.
Supply and fixing of LT ACB (800Amp.) with complete structure. PVVNL Approved.
REPLACEMENT OF DAMAGED L.T. FEEDER PILLAR (MAIN PANNEL) ON TURN-KEY BASIS IN VARIOUS PLACES UNDER SDO - 6, NOIDA AS PER FOLLOWING :-
Supply of new L.T. Feeder Pillar (Main Pannel) as per following specification with all relevant certificate:- 1) LT Feeder Pillar Box (Main Pannel) shall be of 14 SWG HR sheet, having (4) doors, two in front and 2 doors on back side of 14 SWG HR sheet. Doors should have proper locking arrangements with providing crome locks of standard make. It should have a canopy on top in order to prevent it from water ingress in rains. The doors of box should be welded with robust quality hinges and PVC Gasket with provision of 3 hinges on each door and handle on each door with PVC Gasket. The periphery of door of the LT Feeder Pillar Box (Main Pannel) shall be provided with lining of rubber/ PVC to prevent entry of rain, insects, lizards, rats etc. so as to make it vermin proof. 2) The dimension of Feeder Pillar Box (Main Pannel) 5(Height) X 3.5(Width) X 2.5(Depth) Feet (With Canopy). 3) 04 Nos. Bus Bar insulation coated made of aluminum for red, yellow, blue & neutral phases suitable for 400 Amp. 4) 01 No. ISOLATOR SWITCH of 400 Amp. of L&T / Havell’s / ABB make for disconnecting of Supply. 5) 24 Nos. KIT KAT Fuse of 415V, 200 Amp. each capacity tested as per IS shall be provided with 8 Nos. on each phase so as to cater to 8 Nos. 3 Phase connections of branch pannel. 6) Aluminum crimping lugs of size 400 / 240 Sq.mm. and proper size thimbles shall be provided for safe termination of incomer as well as individual service cable as per qty. requirement. 7) Bakelite sheet shall be provided on the base of channel meant for mounting the Kit Kats. 8) All nuts, bolts & washers used shall be electro galvanized. 9) The height of erected feeder pillar box (Main Pannel) approx. 01 feet from the earth on powder coating base of angle iron size 40x40x5mm frame with 04 nos. legs of 1.6 feet each (06 inch grount of angle on earth bottam, 6 inch grout in plinth and 6 inch gap in pannel base and plinth) 10) Grouting & Plinth of Feeder Pillar Box (Main Pannel) as per site requirement complete in all respects. 11) The panel case consisting of door and roof (canopy) shall be powder coated with chemical process (weather proof) of light green color both inside and outside. Before painting, the sun faces shall be thoroughly cleaned from dust, grease and rust. Identification no. shall be written as per direction. 12) Sundry item. Disconncetion AND RECONNECTION of all incoming & outging connection from pannel as per requirement.
Making of plinth with Ist class brick work in the size of 1100(length)x700(width) , 150 mm below the earth and 300 mm above the earth in 1::4 (Cement,Sand) mortar with plaster outer suface of Plinth, all material and work for using in plinth will be provided by the contractor.
Providing & fixing of 3.5c x 240 sq mm aluminium armoured XLPE L.T PVC cable or as per site requirement and as per approved PVVNL technical specification for installation above Meter Pannels as per requirement.
Providing of chemical earthing for above new L.T. Feeder Pillar (Main Pannel) and installation as per following :-
Providing of chemical earthing with earth elctrode strip in pipe terminal type chemical earthing proper hot deep galvanization dia 50 mm length 3 mtr down conductor size - 32mm x 6mm terminal connection hole dia 8mm The cavity between the strip & pipes is filled with condutive mixture - for hermetically filling inside the cavity i.e. between secondary conductor & primary conductor, crystline compound is to be injected in the electrode assembly. It is a combination of high conductivity metal alloys, copper & aluminum power, conductive carbon / cement and bonding material etc the electrode should be sealed from both the ends. The outer pipe of the elctrode should be zinc coated the characteristics of this compound is highly cnductive, non magnetic & non corrosive in G.I. Including providing of Pgs backfill compound each elctrode should be supplied with bags of 25 k.g. x 2 bfc compound (ground resistance enhancement powder 50 kgs each CPRI tested to connect the above chemical earthing with the GI strip of size 32mmx6mm.
Shiv Electricals
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .